Operating Instructions: Terminal Connections: Specifications

This document provides operating instructions for the RC2108 device, including: 1) Specifications such as a 4 digit LED display, AC/DC power supply, programmable rate modes, and input/output terminal connections. 2) Instructions for setting numerical values like the scale factor using the CONFIG and +/- keys, with the blinking digit indicating the selected value. 3) A configuration scheme for programming parameters like the scale factor mantissa from 0.001 to 9.999 and exponent from 0 to -3.

Uploaded by

gillang1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views2 pages

Operating Instructions: Terminal Connections: Specifications

This document provides operating instructions for the RC2108 device, including: 1) Specifications such as a 4 digit LED display, AC/DC power supply, programmable rate modes, and input/output terminal connections. 2) Instructions for setting numerical values like the scale factor using the CONFIG and +/- keys, with the blinking digit indicating the selected value. 3) A configuration scheme for programming parameters like the scale factor mantissa from 0.001 to 9.999 and exponent from 0 to -3.

Uploaded by

gillang1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

OPERATING INSTRUCTIONS Specifications: Terminal Connections: Setting numerical values:

'*' indicates blinking digit. The blinking digit,


RC2108 Short for Config
increments by 1 for every press of the key and
DISPLAY
4 digits, 0.5'' height, red 7 segment LED. rolls over from 9 to 0. The blinking shifts to the
1 2 3 4 5 6
next digit (right) for every press of key. Using
SUPPLY VOLTAGE +12V CNT GND CONFIG these keys user can set the required value.
90 to 270V AC/DC
24V AC/DC 13 + L
RATE MODE CONFIGURATION SCHEME (parameter setting)
14 - N
RPS, RPM, RPH (programmable). To enter configuration scheme:
RANGE NO1 COM1 NC1 NO2 COM2 NC2 1) Short terminal no 4 & 5
4 to 9999 RPM. 7 8 9 10 11 12 2) Turn power ON.
INPUTS
3) Program configuration setting as per
3-30 VDC from Proximity switches (PNP), RELAY1 RELAY2
Encoders, Potential free contacts, Limit instructions below:
switches etc.. 1. To select scale factor mantissa
Please maintain these instructions and
SETPOINTS Description Default : 1.000
review them before using the unit: Terminal
2 (Low alarm and High alarm).
SCALE FACTOR 1 +12VDC sensor supply Key press Display Description
! Warning:
Programmable from 0.001 to 9.999 x 10n
n = 0, 1, 2, -3, -2, -1. 2 Count input Scale factor Set between
1. This unit is panel mounted type with its mantissa 0.001 to 9.999 as
MAXIMUM INPUT SPEED
output terminals getting connected to the
3.5kHz.
4 GND * described above.
host equipment. Such equipment shall also
LED INDICATION 4-5 Short to enter configuration
comply with basic EMI/EMC and safety 2. Press key to select scale factor
Low alarm status, exponent
requirements like BSEN 61326-1 and BSEN 7-8-9 NO - COM - NC of relay1- low alarm Default : 0
High alarm status.
61010 respectively.
ACCURACY 10 - 11 - 12 NO - COM - NC of relay2- high alarm
2. To avoid electric shock, power supply of the Scale factor 0
±0.05 %. 10 = 1
unit should be kept off while wiring. Wiring exponent
SENSOR SUPPLY L-N Live (+) - Neutral (-)
should be done strictly as per the terminal
12 VDC(±10%) , 30 mA. Short circuit
*
layout, given in the manual.
protected. Press 10 1 = 10
3. Use lugged terminals to meet M3 screws.
CONFIGURATION LOCK *
4. The unit does not have a built-in fuse.
via rear terminals.
External fuse with a rating of 275VAC/1A is Input connection for proximity sensor: Press 102 = 100
recommended. OUTPUT
1 C/O each for high and low alarm.
With PNP sensor:
*
HOUSING
Caution: Press 10-3 = 0.001
! Flame retardant plastic.
OPERATING TEMP. 1 2 3 4 5 6 *
1. This unit is not intended for outdoor use. Operating: 0 to 50OC. +12V CNT GND Press 10 -2 = 0.01
2. The power connection cable must have a Storage: -20 to 75OC.
cross-section of atleast 1mm2 and insulation HUMIDITY PNP *
capacity of atleast 1.5kV. 95% RH Press 10-1 = 0.1
3. The output connections must not be loaded WEIGHT
NOTE: dp indicates -ve*sign.
beyond the specified values/range. With NPN sensor:
approx 200 gms
4. Avoid inflow of dust and contact of conductive
1 2 3 4 5 6 3. Press key to select Power ON delay
material with the internal circuitry of the unit. Overall Dimensions:
5. The unit must not operate in presence of Panel Cutout +12V 1k CNT GND Default : 000
heating sources, caustic vapors, oil, steam, Power
vibration or impact etc. 000 to 999 sec
68 69
NPN ON Delay
72
6. Clean the equipment with a clean soft cloth, *
do not use any organic cleaning agent. Care Note: Sensor color codes- Power ON delay: If alarm condition is present
must be taken to avoid entry of water into the 72 115 69 Red --> +12V, Green --> CNT, Black --> GND at power ON, the alarm output will be activated
10
circuitry through the ventilation holes. Brown --> +12V, Black --> CNT, Blue --> GND only after the time set as, Power ON delay.
Document name: Operating/1007/RC2108/version 3 OP-114-V03 Pg. 1 of 2.
8. Press key to select Reset all TO SET ALARMS Data available:
Key press Display Description
Example 1:
4. Press key to select Alarm delay Press for 3sec to set Low Alarm value Diameter of the measuring wheel = 10cm.
Default : 000 No Action Default : 0000 The proximity switch generates 1 pulse / rev. of
Reset all
the measuring wheel.
Press
*
key to complete configuration.
000 to 999 sec Low Alarm value
Alarm Delay
* Press No Action *
dp indicates Alarm delay. The blinking digit increments by 1 for every press
Power ON delay: When alarm condition
* of the key & rolls over from 9 to 0. The blinking
Press No Action selec RC2108
occurs, the alarm output will be activated only shifts to next digit (right) for every press of key. LO
Proximity
Measuring
after the time set as alarm delay. Switch

Note: At Power ON, the higher of the two delay


* Using these keys user can set the required value. HI
Wheel

Press key to enter the Low Alarm value &


values is considered. Press No Action
come out of programming for Low Alarm. LOW HIGH

5. Press key to select Hysteresis *


Default : 05 Press No Action Press for 3sec to set High Alarm value

00 to 99 least
* Default : 9999 Calculations:
Hysteresis Circumference of the wheel =
counts. Press No Action High Alarm value 3.142857 x 0.1 = 0.3142857m.
* * Therefore, the length of the rope delivered /
By pressing key now, all parameters will *
The blinking digit increments by 1 for every press revolution is 0.3142857m. Since the proximity
Low Alarm is activated when Rate < = LA value.
It turns off when, Rate > (LA value + Hysteresis). reset to factory settings and display will go to of the key & rolls over from 9 to 0. switch gives 1 pulse / revolution, the display
High Alarm is activated when Rate >= HA value. step 1 (scale factor mantissa setting). should increment by 0.3142857 for every pulse.
It turns off when, Rate < (HA value - Hysteresis). The blinking shifts to next digit (right) for every Therefore, scale factor = 3.142857 x 10-1.
Press All parameter values Set scale factor mantissa = 3.14285
set to factory setting press of key. Using these keys user can set
Exponent = 10-1
6. Press key to select Resolution * the required value. The RC2106 will show rate in meters / minute.
Press key to enter the Low Alarm value &
Default : 1 To quit configuration:
come out of programming for Low Alarm. Example 2:
1) Turn power off
Resolution 2) Remove link between terminal no 4 & 5 In the same application, if 60 PPR encoder is
* 3) Turn power on
NOTE: High Alarm value should always be fitted instead of proximity switch then:
greater than the Low Alarm value. If high a) The length of rope delivered per revolution is
Press
alarm value is set lower than the low alarm 0.3142857m.
* If terminal no 4 & 5 are shorted at
value or vice versa, the unit will not come out b) The number of pulses / revolution = 60.
power on, rate indicator will go in to the
Press of alarm programming, till the values are c) Length of rope delivered / count pulse =
configuration mode. To quit configuration setting
corrected. 0.3142857 / 60 = 0.005238m.
* mode, turn power off, remove link between 4 &
The display should increment by 0.005238 for
5 & switch power on.
Press TO READ ALARMS every pulse.
* Note: Key press Display Name / Therefore, scale factor = 5.23800 x 10-3.
7. Press key to select Mode 1. If input speed is above the indication range, (MOMENTARY) Description Set scale factor mantissa = 5.23800
display indicates 1 in the MSD position. Exponent = 10-3 for required display.
Default : 1 (RPM) 2. If input speed is below the indication range, Press Low Alarm value
display indicates 0.
Selec Controls Pvt. Ltd.
Mode RPM Press High Alarm value Specifications are subject to change, since development is a
* continuous process
NOTE: Maximum display time is 3 sec. Telephone: +91-22-40394200 / 40394202
Press RPH Fax: +91-22-28471733
* TYPICAL APPLICATION: Toll free: 1800 227 353
Website: www.selec.com
Press Objective: To display the delivery rate of the cord Email: [email protected]
RPS
(meters / minute). Operating/1010/RC2108/OP114-V03 (Page 2 of 2)
*