Change Bearing
Change Bearing
Change Bearing
The purpose of this procedue is to inform and explain in details the bearings change for blower On site for a
preventive maintenance plan or for a corrective maintenance action.
This is a general procedure, in case of special operation please refer to Factory instruction.
1
5
1 - Sledgehammer.
2 - Depth gauge
3 - Mechanical screwdrivers.
4
4 - Socket wrench: 24 mm.
5 - Allen keys: 5 to 16 mm.
6 - Flat spanners: 10, 13, 24 mm.
6
AR Nº: DATE:
PROJECT: ...........................................................................................................................................................................................................
...............................................................................................................................................................................................................................
1 - Machine environment
Hydraulic Jack.
Hub extractor.
Introduction: Locate on the blower section drawing, the fixed bearing side (generally the inlet side).
We will call him side A and the bearing, which have the outer ring free, side B.
For work in the state of art, we will always change the free bearing (side B) first. The blocked bearing,
which will be changed later on, will guarantee the food position of the rotor for the assembly of the
two bearing, and will absorb the schocks due to the assembly of the new bearing.
B
A
B A
B
A
15 14 9 7 6 1
8
10 2 1 - HOUSING, BEARING
11 3 2 - RETAINER, CARBON RING
3 - ADAPTER, CARBON RING
4
4 - CARBON RING
5 - FAN COOLING
6 - BEARING, BALL 6320 C3 THT
7 - SPACER, LONG
8 - SPACER, SHORT
9 - OIL SLINGER
10 - WASHER, MB20
11 - NUT, KM20
12 - BILL RESERVOIR
13 - CAP, OIL RESERVOIR
14 - GASKET, BEARING CAP
5
12 15 - CAP, BEARING-INLET END
13
SAMPLE DRAWING.
REFER TO OIL LUBRICATED MOD 600.A
INLET BEARINGS HOUSING DETAIL WITH CARBON RING SEAL (MODEL 600.A).
Using 4 jack bolts HM16-100, to extract the housing with the bearing. To drive out the bearing of the housing
using a jet.
4 Extaction holes
To deposit the ventilator (not to forget to loosen the 2 screws in compression AHCM 8 - 20 Pl) to slightly warm
it in order to dilate it to facilitate it´s demounting.
3 - Sealing packing
Introduction: for work in the state of art, its important to well clean the internals parts of the housing with a
cleaning product, which will guarantee the life of the bearing.
Measure the disctance X: from the beginning of the shaft until the shoulder.
With a bearing heater, warm the inner ring of the new bearing to 90ºC.
With a hand anvil (tools item 7) and a little sledgehammer, install the bearing on taping on the hand anvil
until it rebounds on the bearing.
Check the location of the bearing with the distance X minus the bearing thickness.
Same operating mode that side B bearing´s housing B until the assembly of the bearing.
Block the position of the shaft with a hub extractor on the side B bearing housing.
The extractor is useful here to fix the position of the shaft to prevent it from moving back during
the assembly of bearing side A and has to absorb the shocks during the assembly of the new bearing.
+ 1 - 2 mm
Extractor
Measure the distance X: from the beginning of the shaft until the shoulder.
With a bearing heater, hear the inner ring of the new bearing until 90ºC.
With a hand anvil (tools item) and a little sledgehammer, install the bearing on taping on the hand
anvil until it rebounds on the bearing.
Check the location of the bearing with the distance X minus the bearing thickness.
(Very important for the location of the rotor)
Remove the hub extractor from the side B and close the housing.
7 - Oil levelling
The housing can be correctly filled by introducing the oil via the opening made by removing the plug 1
(see figure A) until a few drops emerge from the opening made by removing the plug 2.
Once this level have been reached, plugs 1 and 2 can be replaced and oil can continue to be added via
the transparent bulb in the oil feeder (as show in figure B) until the level in the bulb itself stabilizes.
1. FILLING PLUG
2. LEVEL PLUG
3. DRAIN PLUG
1. CORRECT
2. INCORRECT