Q.PEAK DUO XL-G10.

2
470-495
ENDURING HIGH
PERFORMANCE

BREAKING THE 21 % EFFICIENCY BARRIER


Q.ANTUM DUO Z Technology with zero gap cell layout boosts
module efficiency up to 21.6 %.

LOW ELECTRICITY GENERATION COSTS


Higher yield per surface area, lower BOS costs and up to 80 watts
more module power than standard 144 half-cell modules.

ENDURING HIGH PERFORMANCE


Long-term yield security with Anti LID Technology, Anti PID
Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™.

EXTREME WEATHER RATING


High-tech aluminum alloy frame, certified for
high snow (5400 Pa) and wind loads (3000 Pa).

A RELIABLE INVESTMENT
Inclusive 12-year product warranty and 25-year
linear performance warranty2.

STATE OF THE ART MODULE TECHNOLOGY


Q.ANTUM DUO combines cutting edge cell separation
and innovative 12-busbar design with Q.ANTUM Technology.

1
APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h)
2
See data sheet on rear for further information.
6 BUSBAR 12 BUSBAR
CELL TECHNOLOGY CELL TECHNOLOGY

THE IDEAL SOLUTION FOR:


Ground-mounted
solar power plants
ASYMMETRIC Q.PEAK DUO L-G10.1/L-G10.2
MECHANICAL SPECIFICATION
MIDRAIL
Format
NA
87.2 in × 41.1 in × 1.38 in (including frame)
(2216 mm × 1045 mm × 35 mm) 87.2" (2216 mm)
51.5" (1308 mm)
Weight 58.4 lbs (26.5 kg) 31.1" (790 mm)
15.7" (400 mm) 17.9" (454 mm)

Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with 4 × Grounding holes, Ø 0.18" (4.5 mm) 4 × Drainage holes
anti-reflection technology 4 × Mounting slots system Tracker (DETAIL B)
Frame
Back Cover Composite film 39.4" ≥ 27.6" (700 mm)
39.5"
(1001 mm) (1003 mm)
Frame Anodized aluminum
41.1"
(1045 mm)
Cell 6 × 26 monocrystalline Q.ANTUM solar half cells
Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in
≥ 13.8" (350 mm)
(53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes Label

Cable 4 mm² Solar cable; (+) ≥ 27.6 in (700 mm), (−) ≥ 13.8 in (350 mm)* 4 × Mounting slots (DETAIL A)
8 × Drainage holes
0.12 × 0.24" (3 × 6 mm)

Connector Stäubli MC4, Stäubli MC4-Evo2, Hanwha Q CELLS HQC4; IP68 0.63" (16 mm) 0.39" (10 mm)
1.38" (35 mm) DETAIL A DETAIL B

*Long cables (+) ≥ 57.1 in (1450 mm), (−) ≥ 57.1 in (1450 mm) for 0.83" (21 mm)
0.33" (8.5 mm)
0.87" (22 mm)
0.28" (7 mm)

landscape installation are available upon request. Drawing not to scale

ELECTRICAL CHARACTERISTICS
POWER CLASS 470 475 480 485 490 495
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)
Power at MPP1 PMPP [W] 470 475 480 485 490 495
Short Circuit Current1 I SC [A] 11.21 11.24 11.26 11.29 11.31 11.34
Minimum

Open Circuit Voltage1 VOC [V] 53.54 53.58 53.61 53.64 53.68 53.71
Current at MPP I MPP [A] 10.62 10.66 10.71 10.76 10.81 10.86
Voltage at MPP VMPP [V] 44.27 44.54 44.81 45.07 45.33 45.59
Efficiency1 η [%] ≥ 20.3 ≥ 20.5 ≥ 20.7 ≥ 20.9 ≥ 21.2 ≥ 21.4
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2
Power at MPP PMPP [W] 352.6 356.4 360.1 363.9 367.6 371.4
Short Circuit Current I SC [A] 9.03 9.05 9.07 9.09 9.12 9.14
Minimum

Open Circuit Voltage VOC [V] 50.49 50.53 50.56 50.59 50.62 50.65
Current at MPP I MPP [A] 8.34 8.39 8.43 8.47 8.52 8.56
Voltage at MPP VMPP [V] 42.26 42.49 42.72 42.94 43.17 43.39
1
Measurement tolerances PMPP ± 3 %; I SC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE

100 110
RELATIVE EFFICIENCY [%]
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]

98
Q CELLS
Industry standard for linear warranties*
At least 98 % of nominal power during
first year. Thereafter max. 0.5 %
95 degradation per year. At least 93.5 % 100
of nominal power up to 10 years. At
least 86 % of nominal power up to
90
25 years. 90

Specifications subject to technical changes © Q CELLS Q.PEAK DUO XL-G10.2_470-495_2022-01_Rev03_NA


EN 86
85
All data within measurement toleranc-
80
es. Full warranties in accordance with 200 400 600 800 1000
the warranty terms of the Q CELLS IRRADIANCE [W/m²]
80
sales organisation of your respective
0 5 10 15 20 25 country.
*
Standard terms of guarantee for the 10 PV companies YEARS Typical module performance under low irradiance conditions in
with the highest production capacity in 2014 (as at: September 2014)
comparison to STC conditions (25 °C, 1000 W/m²)

TEMPERATURE COEFFICIENTS
Temperature Coefficient of I SC α [% / K] +0.04 Temperature Coefficient of VOC β [% / K] −0.27
Temperature Coefficient of PMPP γ [% / K] −0.34 Nominal Module Operating Temperature NMOT [°F] 109 ± 5.4 (43 ± 3 °C)

PROPERTIES FOR SYSTEM DESIGN


Maximum System Voltage VSYS [V] 1500 (IEC) / 1500 (UL) PV module classification Class II
Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI / UL 61730 TYPE 1
Max. Design Load, Push / Pull3 [lbs/ft2] 75 (3600 Pa) / 42 (2000 Pa) Permitted Module Temperature −40 °F up to +185 °F
on Continuous Duty (−40 °C up to +85 °C)
Max. Test Load, Push / Pull3 [lbs/ft2] 113 (5400 Pa) / 63 (3000 Pa) 
3
See Installation Manual

QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION

UL 61730, CE-compliant, 53'


IEC 61215:2016, 40' HC
IEC 61730:2016,
U.S. Patent No. 9,893,215 Horizontal 89.4 in 43.3 in 47.6 in 1809 lbs 22 20 29
(solar cells); Certified
packaging 2270 mm 1100 mm 1210 mm 821 kg pallets pallets modules
UL 61730

Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use