Q CELLS Data Sheet Q.PEAK DUO XL-G10.2 470-495 2022-01 Rev03 NA
Q CELLS Data Sheet Q.PEAK DUO XL-G10.2 470-495 2022-01 Rev03 NA
Q CELLS Data Sheet Q.PEAK DUO XL-G10.2 470-495 2022-01 Rev03 NA
2
470-495
ENDURING HIGH
PERFORMANCE
A RELIABLE INVESTMENT
Inclusive 12-year product warranty and 25-year
linear performance warranty2.
1
APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h)
2
See data sheet on rear for further information.
6 BUSBAR 12 BUSBAR
CELL TECHNOLOGY CELL TECHNOLOGY
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with 4 × Grounding holes, Ø 0.18" (4.5 mm) 4 × Drainage holes
anti-reflection technology 4 × Mounting slots system Tracker (DETAIL B)
Frame
Back Cover Composite film 39.4" ≥ 27.6" (700 mm)
39.5"
(1001 mm) (1003 mm)
Frame Anodized aluminum
41.1"
(1045 mm)
Cell 6 × 26 monocrystalline Q.ANTUM solar half cells
Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in
≥ 13.8" (350 mm)
(53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes Label
Cable 4 mm² Solar cable; (+) ≥ 27.6 in (700 mm), (−) ≥ 13.8 in (350 mm)* 4 × Mounting slots (DETAIL A)
8 × Drainage holes
0.12 × 0.24" (3 × 6 mm)
Connector Stäubli MC4, Stäubli MC4-Evo2, Hanwha Q CELLS HQC4; IP68 0.63" (16 mm) 0.39" (10 mm)
1.38" (35 mm) DETAIL A DETAIL B
*Long cables (+) ≥ 57.1 in (1450 mm), (−) ≥ 57.1 in (1450 mm) for 0.83" (21 mm)
0.33" (8.5 mm)
0.87" (22 mm)
0.28" (7 mm)
ELECTRICAL CHARACTERISTICS
POWER CLASS 470 475 480 485 490 495
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)
Power at MPP1 PMPP [W] 470 475 480 485 490 495
Short Circuit Current1 I SC [A] 11.21 11.24 11.26 11.29 11.31 11.34
Minimum
Open Circuit Voltage1 VOC [V] 53.54 53.58 53.61 53.64 53.68 53.71
Current at MPP I MPP [A] 10.62 10.66 10.71 10.76 10.81 10.86
Voltage at MPP VMPP [V] 44.27 44.54 44.81 45.07 45.33 45.59
Efficiency1 η [%] ≥ 20.3 ≥ 20.5 ≥ 20.7 ≥ 20.9 ≥ 21.2 ≥ 21.4
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2
Power at MPP PMPP [W] 352.6 356.4 360.1 363.9 367.6 371.4
Short Circuit Current I SC [A] 9.03 9.05 9.07 9.09 9.12 9.14
Minimum
Open Circuit Voltage VOC [V] 50.49 50.53 50.56 50.59 50.62 50.65
Current at MPP I MPP [A] 8.34 8.39 8.43 8.47 8.52 8.56
Voltage at MPP VMPP [V] 42.26 42.49 42.72 42.94 43.17 43.39
1
Measurement tolerances PMPP ± 3 %; I SC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
100 110
RELATIVE EFFICIENCY [%]
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]
98
Q CELLS
Industry standard for linear warranties*
At least 98 % of nominal power during
first year. Thereafter max. 0.5 %
95 degradation per year. At least 93.5 % 100
of nominal power up to 10 years. At
least 86 % of nominal power up to
90
25 years. 90
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I SC α [% / K] +0.04 Temperature Coefficient of VOC β [% / K] −0.27
Temperature Coefficient of PMPP γ [% / K] −0.34 Nominal Module Operating Temperature NMOT [°F] 109 ± 5.4 (43 ± 3 °C)
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use
of this product.