0% found this document useful (0 votes)
198 views17 pages

Topic 3 - Strength Analysis of Beams According To ACI Code PDF

The document discusses the design of reinforced concrete beams according to ACI code. It covers topics such as strength analysis, design principles, derivation of beam expressions, strength reduction factors, and balanced, tension-controlled, and compression-controlled beam sections. Formulas are presented for calculating the percentage of steel, concrete beam design ratio, balanced steel area, and minimum steel percentages. A sample problem demonstrates calculating the design strength of a beam using different numbers of tension bars.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
198 views17 pages

Topic 3 - Strength Analysis of Beams According To ACI Code PDF

The document discusses the design of reinforced concrete beams according to ACI code. It covers topics such as strength analysis, design principles, derivation of beam expressions, strength reduction factors, and balanced, tension-controlled, and compression-controlled beam sections. Formulas are presented for calculating the percentage of steel, concrete beam design ratio, balanced steel area, and minimum steel percentages. A sample problem demonstrates calculating the design strength of a beam using different numbers of tension bars.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

CERCDS56D:

REINFORCED
CONCRETE DESIGN
W E E K 2 , TO P I C 3
STRENGTH ANALYSIS
OF BEAMS
ACCORDING TO ACI
CODE
W E E K 2 : TO P I C 3
STRENGTH DESIGN
VS.
WORKING STRESS
DESIGN
W E E K 2 : TO P I C 3
DERIVATION OF BEAM EXPRESSIONS

Design Principle:
Actual Loads ≤ Allowable Loads

𝑴𝒖 ≤ 𝝓𝑴𝒏
where:
𝑀𝑢 = 𝐹𝑎𝑐𝑡𝑜𝑟𝑒𝑑 𝑀𝑜𝑚𝑒𝑛𝑡
𝑀𝑛 = 𝑁𝑜𝑚𝑖𝑛𝑎𝑙 𝑀𝑜𝑚𝑒𝑛𝑡
DERIVATION OF BEAM EXPRESSIONS
DERIVATION OF BEAM EXPRESSIONS
DERIVATION OF BEAM EXPRESSIONS
FORMULAS FOR 𝜷
English Units SI Units

STRENGTH REDUCTION OR 𝝓 FACTORS


STRENGTH REDUCTION FACTORS
BALANCED SECTIONS, TENSION-CONTROLLED
SECTIONS, AND COMPRESSION-CONTROLLED
SECTIONS
BALANCED SECTIONS, TENSION-CONTROLLED
SECTIONS, AND COMPRESSION-CONTROLLED
SECTIONS
𝑓𝑠 = 𝑡𝑒𝑛𝑠𝑖𝑜𝑛 𝑠𝑡𝑟𝑒𝑠𝑠 𝑜𝑓 𝑡ℎ𝑒 𝑏𝑒𝑎𝑚 @strain = 0.005
𝑓𝑠 = 𝑠𝑡𝑟𝑎𝑖𝑛 𝐸 𝑓𝑠 = 0.005 (29 𝑥 106 ) = 145000 psi
𝑓𝑠 = 0.005 200000 = 𝟏𝟎𝟎𝟎 𝑴𝑷𝒂
𝐸𝑠 = 29 𝑥 106 𝑝𝑠𝑖
𝐸𝑠 = 200,000 𝑀𝑃𝑎

@strain = 0.003 (yield)


𝑓𝑠 = 0.003 (29 𝑥 106 ) = 87000 psi
𝑓𝑠 = 0.003 200000 = 𝟔𝟎𝟎 𝑴𝑷𝒂
BALANCED SECTIONS, TENSION-CONTROLLED
SECTIONS, AND COMPRESSION-CONTROLLED
SECTIONS
𝑪𝑶𝑴𝑷𝑹𝑬𝑺𝑺𝑰𝑶𝑵 𝑪𝑶𝑵𝑻𝑹𝑶𝑳𝑳𝑬𝑫 𝑻𝑹𝑨𝑵𝑺𝑰𝑻𝑰𝑶𝑵 𝑻𝑬𝑵𝑺𝑰𝑶𝑵 𝑪𝑶𝑵𝑻𝑹𝑶𝑳𝑳𝑬𝑫
𝒇𝒔 ≤ 𝟖𝟕𝟎𝟎𝟎 𝒑𝒔𝒊 𝟖𝟕𝟎𝟎𝟎 < 𝒇𝒔 < 𝟏𝟒𝟓𝟎𝟎𝟎 𝒑𝒔𝒊 𝒔𝒕𝒓𝒂𝒊𝒏 ≥ 𝟎. 𝟎𝟎𝟓
𝒇𝒔 ≤ 𝟔𝟎𝟎 𝑴𝑷𝒂 𝟔𝟎𝟎 < 𝒇𝒔 < 𝟏𝟎𝟎𝟎 𝑴𝑷𝒂

𝒇𝒔 − 𝟖𝟕𝟎𝟎𝟎 𝒇𝒔 ≥ 𝟏𝟒𝟓𝟎𝟎𝟎 𝒑𝒔𝒊


𝒔𝒕𝒓𝒂𝒊𝒏 ≤ 𝟎. 𝟎𝟎𝟑 𝝓 = 𝟎. 𝟔𝟓 + 𝟎. 𝟐𝟓 𝒇𝒔 ≥ 𝟏𝟎𝟎𝟎 𝑴𝑷𝒂
𝟏𝟒𝟓𝟎𝟎𝟎 − 𝟖𝟕𝟎𝟎𝟎
𝒇𝒔 − 𝟔𝟎𝟎
𝝓 = 𝟎. 𝟔𝟓 𝝓 = 𝟎. 𝟔𝟓 + 𝟎. 𝟐𝟓
𝟏𝟎𝟎𝟎 − 𝟔𝟎𝟎
𝝓 = 𝟎. 𝟗𝟎
DERIVATION OF BEAMS EXPRESSIONS
𝑷𝒆𝒓𝒄𝒆𝒏𝒕𝒂𝒈𝒆 𝒐𝒇 𝒕𝒉𝒆 𝒔𝒕𝒆𝒆𝒍, 𝝆 𝑪𝒐𝒏𝒄𝒓𝒆𝒕𝒆 𝑩𝒆𝒂𝒎 𝑫𝒆𝒔𝒊𝒈𝒏 𝑹𝒂𝒕𝒊𝒐, 𝑹𝒏
𝑨𝒔 𝑴𝒏
𝝆= 𝑹𝒏 =
𝒃𝒅 𝒃𝒅𝟐

𝑎
𝑀𝑛 = 𝐴𝑠 𝑓𝑦 𝑑 −
𝐶=𝑇 2
0.85𝑓 ′ 𝑐 𝑎𝑏 = 𝐴𝑠𝑓𝑦 𝑓𝑦 𝜌 𝑑
𝑀𝑛 = 𝐴𝑠 𝑓𝑦 𝑑 −
0.85 𝑓 ′ 𝑐 2
𝐴𝑠 𝑓𝑦 𝑓𝑦 𝜌
𝑎= 𝑀𝑛 = 𝐴𝑠 𝑓𝑦 𝑑 1 − 𝟎. 𝟖𝟓𝒇′ 𝒄 𝟐𝑹𝒏
0.85 𝑓 ′ 𝑐 𝑏 1.7 𝑓 ′ 𝑐 𝝆= 𝟏− 𝟏−
𝒇𝒚 𝟎. 𝟖𝟓𝒇′ 𝒄
𝒇𝒚 𝝆 𝒅 𝜌 𝑓𝑦
𝒂= 𝑀𝑛 = 𝑓𝑦 𝜌 𝑏 𝑑 2 1 −
𝟎. 𝟖𝟓 𝒇′ 𝒄 1.7 𝑓 ′ 𝑐

𝝆 𝒇𝒚
𝝓𝑴𝒏 = 𝝓 𝒇𝒚 𝝆 𝒃 𝒅𝟐 𝟏 −
𝟏. 𝟕 𝒇′ 𝒄
BALANCED STEEL AREA, 𝜌 𝑏
𝑐 𝑑 𝑓𝑦 𝜌𝑏 𝑑
= 𝑎=
0.003 𝜖𝑦 + 0.003 0.85 𝑓 ′ 𝑐
0.003 𝑑 𝑓𝑦 𝜌𝑏 𝑑
𝑐= 𝑎 = 𝑐𝛽 =
𝑓𝑦/𝐸𝑠 + 0.003 0.85 𝑓 ′ 𝑐
87000𝑑 𝑓𝑦 𝜌𝑏 𝑑
𝑐 = 𝑓𝑦+87000 𝑒𝑞. 1 𝑐 = 0.85 𝑓′ 𝑐 𝛽 𝑒𝑞. 2

87000𝑑 𝑓𝑦 𝜌𝑏 𝑑
=
𝑓𝑦 + 87000 0.85 𝑓 ′ 𝑐 𝛽
87000 𝑑 0.85 𝑓 ′ 𝑐 𝛽
𝜌𝑏 = 𝐸𝑛𝑔𝑙𝑖𝑠ℎ 𝑈𝑛𝑖𝑡
𝑓𝑦 + 87000 𝑓𝑦 𝑑

600𝑑 𝑓𝑦 𝜌𝑏 𝑑
=
𝑓𝑦 + 600 0.85 𝑓 ′ 𝑐 𝛽
600 𝑑 0.85 𝑓 ′ 𝑐 𝛽
𝜌𝑏 = 𝑆𝐼 𝑈𝑛𝑖𝑡
𝑓𝑦 + 600 𝑓𝑦 𝑑
MINIMUM STEEL PERCENTAGES
ENGLISH UNITS SI UNITS
SAMPLE PROBLEM 1:
Given the following data of a singly reinforced
rectangular beam: a. ) 4 tension bars
Beam width, b = 330 mm 𝐴𝑠 = 4 𝐴𝑏 = 4 (490.87) = 1963.48 mm^2
Effective depth, d = 450 mm
𝐴𝑠 1963.48
Tension Bar diameter = 25 mm 𝜌= = = 0.0132 < 𝜌𝑏
𝑏𝑑 330(450)
Concrete strength, f’c = 27.5 Mpa Required: ∴ 𝑡𝑒𝑛𝑠𝑖𝑜𝑛 𝑠𝑡𝑒𝑒𝑙 𝑦𝑖𝑒𝑙𝑑𝑠
Steel strength, fy = 414 MPa 𝑀𝑢 𝑜𝑟 𝜙𝑀𝑛 𝑓𝑠 = 𝑓𝑦
Solution:
Compute the design strength of the beam 𝛽 = 0.85 f ′ c < 30MPa 𝐶=𝑇
under the following conditions:
0.85𝑓 ′ 𝑐
𝑎 𝑏 = 𝐴𝑠 𝑓𝑦
a.) Using four tension bars 2
𝜋 25 𝐴𝑠 𝑓𝑦 1963.48 (414)
b.) Using six tension bars 𝐴𝑏 = = 490.87 𝑚𝑚2 𝑎= =
4 0.85 𝑓 ′𝑐 𝑏 0.85 27.5 (330)
c.) Using nine tension bars 𝑎 = 105.38 𝑚𝑚
600 𝑑 0.85 𝑓 ′ 𝑐 𝛽
𝜌𝑏 = a
Given: 𝑓𝑦 + 600 𝑓𝑦 𝑑
𝑀𝑛 = 0.85 f ′ c a b d −
Beam width, b = 330 mm 2
Effective depth, d = 450 mm 600 450 0.85 27.5 0.85 105.38
𝑀𝑛 = 0.85 27.5 105.38 330 450 −
Tension Bar diameter = 25 mm 𝜌𝑏 = 2
414 + 600 414 450
Concrete strength, f’c = 27.5 MPa 𝑀𝑛 = 322963356.3 N – mm
𝑀𝑛 = 322.963 𝑘𝑁 − 𝑚
Steel strength, fy = 414 MPa 𝜌𝑏 = 0.028 𝜙 = 0.9
𝑀𝑢 = 𝜙𝑀𝑛 = 0.9 322.963 = 𝟐𝟗𝟎. 𝟔𝟕 𝒌𝑵 − 𝒎
SAMPLE PROBLEM 1
b.) Use 6 tension bars
𝛽 = 0.85 𝑓𝑠 600
𝐴𝑏 = 490.87 𝑚𝑚2 =
𝑑−𝑐 𝑐
𝜌𝑏 = 0.028 𝒅 −𝒄
𝒇𝒔 = 𝟔𝟎𝟎
𝒄
𝐴𝑠 = 6 𝐴𝑏 = 6 490.87 = 2945.22 𝑚𝑚2
𝐴𝑠 2945.22 a 158.07
𝜌= =
𝑏𝑑 (330)(450)
= 0.0198 < 0.028 𝑐= = = 185.96 𝑚𝑚
𝛽 0.85

∴ 𝑡ℎ𝑒 𝑡𝑒𝑛𝑠𝑖𝑜𝑛 𝑠𝑡𝑒𝑒𝑙 𝑦𝑖𝑒𝑙𝑑𝑠 450 − 185.96


𝑓𝑠 = (600) = 851.93 𝑀𝑃𝑎
𝑓𝑠 = 𝑓𝑦 185.96
𝐶=𝑇 < 1000𝑀𝑃𝑎
0.85 𝑓 ′ 𝑐 𝑎 𝑏 = 𝐴𝑠 𝑓𝑦 ∴ 𝑡𝑟𝑎𝑛𝑠𝑖𝑡𝑖𝑜𝑛 𝑟𝑒𝑔𝑖𝑜𝑛
(2945.22)(414)
𝑎= = 158.07 𝑚𝑚
0.85 (27.5)(330) 𝑓𝑠 − 600
𝜙 = 0.65 + 0.25
1000 − 600
𝑎
𝑀𝑛 = 𝐴𝑠 𝑓𝑦 𝑑 − 851.93 − 600
2 𝜙 = 0.65 + 0.25
158.07 1000 − 600
𝑀𝑛 = 2945.22 414 450 − = 452.33 kN − m
2 𝜙 = 0.81
𝜙𝑀𝑛 = 0.81 452.33 = 𝟑𝟔𝟔. 𝟑𝟖 𝒌𝑵 − 𝒎
SAMPLE PROBLEM 1 𝑑−𝑐 450 − 269.86
c.) Use 9 rebars 𝑓𝑠 = 600 = 600
𝛽 = 0.85 𝑐 269.86
𝐴𝑏 = 490.87 𝑚𝑚2 𝑓𝑠 = 400.52 𝑀𝑃𝑎 < 𝑓𝑦
𝜌𝑏 = 0.028 ∴ 𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑖𝑜𝑛 𝑐𝑜𝑛𝑡𝑟𝑜𝑙𝑙𝑒𝑑

𝑎 = 𝛽𝑐 = 0.85 269.86 = 229.381 𝑚𝑚


𝐴𝑠 = 9 490.87 = 4417.83 𝑚𝑚2
𝑎
𝑀𝑛 = 𝐴𝑠 𝑓𝑠 𝑑 −
𝐴𝑠 4417.83 2
𝜌= = = 0.0297 > 𝜌𝑏 229.381
𝑏𝑑 (330)(450) 𝑀𝑛 = 4417.93 400.52 450 −
∴ 𝑡ℎ𝑒 𝑡𝑒𝑛𝑠𝑖𝑜𝑛 𝑠𝑡𝑒𝑒𝑙 𝑑𝑜𝑒𝑠 𝑛𝑜𝑡 𝑦𝑖𝑒𝑙𝑑 2
𝑓𝑠 ≠ 𝑓𝑦 𝑀𝑛 = 593.306 𝑘𝑁 − 𝑚
𝜙 = 0.65
𝑀𝑢 = 𝜙𝑀𝑛 = 0.65 593.306 = 𝟑𝟖𝟓. 𝟔𝟓 𝒌𝑵 − 𝒎
𝐶=𝑇
0.85 𝑓 ′ 𝑐 𝑎 𝑏 = 𝐴𝑠 𝑓𝑠
𝑑 −𝑐
𝑓𝑠 = 600 𝑎=𝛽𝑐
𝑐
𝑑−𝑐
0.85 𝑓 ′ 𝑐 𝛽 𝑐 𝑏 = 𝐴𝑠 600
𝑐
450 − 𝑐
0.85 27.5 0.85 𝑐 330 = 4417.83 600
𝑐
𝒄 = 𝟐𝟔𝟗. 𝟖𝟔 𝒎𝒎

You might also like