0% found this document useful (0 votes)
112 views3 pages

IEEE Template 1col

This document provides guidelines for preparing camera-ready papers for IEEE conference proceedings in one column format. It discusses paper layout including margins and type sizes. It provides guidance on formatting figures, tables, references, equations, units and avoiding common mistakes. Key recommendations include using US letter or A4 paper size, 10pt font for main text, centering figures and tables, numbering references in square brackets, defining abbreviations the first time used and using SI units where possible.

Uploaded by

Disha Goel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views3 pages

IEEE Template 1col

This document provides guidelines for preparing camera-ready papers for IEEE conference proceedings in one column format. It discusses paper layout including margins and type sizes. It provides guidance on formatting figures, tables, references, equations, units and avoiding common mistakes. Key recommendations include using US letter or A4 paper size, 10pt font for main text, centering figures and tables, numbering references in square brackets, defining abbreviations the first time used and using SI units where possible.

Uploaded by

Disha Goel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Preparation of Papers in IEEE-style Format

for only One Column


N. E. Cotter
(modified from doc by) IEEE Conference Publishing
445 Hoes Lane
Piscataway, NJ 08855-1331

Abstract-These instructions give you basic guidelines for preparing camera-ready papers for conference proceedings.

I. INTRODUCTION
Your goal is to simulate the usual appearance of papers in an IEEE conference proceedings. For items not addressed in these
instructions, please refer to the last issue of your conference’s proceedings or your Publications chair.
A. Full-Sized Camera-Ready (CR) Copy
Prepare your CR paper in full-size format, on US letter paper (8.5 by 11 inches). For A4 paper, use the A4 template.
Type sizes and typefaces: Follow the type sizes specified in Table I. As an aid in gauging type size, 1 point is about 0.35 mm.
The size of the lowercase letter “j” will give the point size. Times New Roman is the preferred font.
1) US letter margins: top = 0.75 inches, bottom = 1 inch, side = 0.625 inches.
2) A4 margins: top = 19mm, bottom = 43mm, side = 13 mm.
The column width is 88mm (3.45 in). The space between the two columns is 4mm (0.17 in). Paragraph indentation is 3.5 mm
(0.14 in).
Left- and right-justify your columns. Use tables and figures to adjust column length. On the last page of your paper, adjust the
lengths of the columns so that they are equal. Use automatic hyphenation and check spelling. Digitize or paste down figures.
TABLE I
TYPE SIZES FOR CAMERA-READY PAPERS
Type Appearance
size
(pts.) Regular Bold Italic
6 Table captions,a table superscripts
8 Section titles, a references, tables,
table names,a first letters in table
captions,a figure captions,
footnotes, text subscripts, and
superscripts
9 Abstract
10 Authors’ affiliations, main text, Subheading
equations, first letters in section
titlesa
11 Authors’ names
24 Paper title
a
Uppercase

15

10

0
-1 0 1 2 3 4 5
Applied Field (104 A/m)

Figure 1. Magnetization as a function of applied field.


Note how the caption is centered in the column.
II. HELPFUL HINTS

B. Figures and Tables


Position figures and tables at the tops and bottoms of columns. Avoid placing them in the middle of columns. Large figures
and tables may span across both columns. Figure captions should be centered below the figures; table captions should be
centered above. Avoid placing figures and tables before their first mention in the text. Use the abbreviation “Fig. 1,” even at the
beginning of a sentence.
Figure axis labels are often a source of confusion. Use words rather than symbols. For example, write “Magnetization,” or
“Magnetization, M,” not just “M.” Put units in parentheses. Do not label axes only with units. In the example, write
“Magnetization (A/m)” or “Magnetization (A  m 1).” Do not label axes with a ratio of quantities and units. For example, write
“Temperature (K),” not “Temperature/K.”
Multipliers can be especially confusing. Write “Magnetization (kA/m)” or “Magnetization (10 3 A/m).” Figure labels should be
legible, about 10-point type.
C. References
Number citations consecutively in square brackets [1]. Punctuation follows the bracket [2]. Refer simply to the reference
number, as in [3]. Use “Ref. [3]” or Reference [3]” at the beginning of a sentence: “Reference [3] was the first …”
Number footnotes separately in superscripts. Place the actual footnote at the bottom of the column in which it was cited. Do
not put footnotes in the reference list. Use letters for table footnotes (see Table I). IEEE Transactions no longer use a journal
prefix before the volume number. For example, use “IEEE Trans. Magn., vol. 25,” not “vol. MAG-25.
Give all authors’ names; use “et al.” if there are six authors or more. Papers that have not been published, even if they have
been submitted for publication, should be cited as “unpublished” [4]. Papers that have been accepted for publication should be
cited as “in press” [5]. In a paper title, capitalize the first word and all other words except for conjunctions, prepositions less than
seven letters, and prepositional phrases.
For papers published in translated journals, first give the English citation, then the original foreign-language citation [6].
D. Abbreviations and Acronyms
Define abbreviations and acronyms the first time they are used in the text, even if they have been defined in the abstract.
Abbreviations such as IEEE, SI, MKS, CGS, sc, dc, and rms do not have to be defined. Do not use abbreviations in the title
unless they are unavoidable.
E. Equations
Number equations consecutively with equation numbers in parentheses flush with the right margin, as in (1). To make your
equations more compact, you may use the solidus ( / ), the exp function, or appropriate exponents. Italicize Roman symbols for
quantities and variables, but not Greek symbols. Use an en dash (–) rather than a hyphen for a minus sign. Use parentheses to
avoid ambiguities in denominators. Punctuate equations with commas or periods when they are part of a sentence, as in

a + b = c. (1)

Symbols in your equation should be defined before the equation appears or immediately following. Use “(1),” not “Eq. (1)” or
“equation (1),” except at the beginning of a sentence: “Equation (1) is …”
Other Recommendations
The Roman numerals used to number the section headings are optional. If you do use them, do not number
ACKNOWLEDGMENT and REFERENCES, and begin Subheadings with letters. Use two spaces after periods (full stops). Hyphenate
complex modifiers: “zero-field-cooled magnetization.” Avoid dangling participles, such as, “Using (1), the potential was
calculated.” Write instead, “The potential was calculated using (1),” or “Using (1), we calculated the potential.”
Use a zero before decimal points: “0.25,” not “.25.” Use “cm 3,” not “cc.” Do not mix complete spellings and abbreviations of
units: “Wb/m2” or “webers per square meter,” not “webers/m 2.” Spell units when they appear in text: “…a few henries,” not
“…a few H.” If your native language is not English, try to get a native English-speaking colleague to proofread your paper. Do
not add page numbers.
III. UNITS
Use either SI (MKS) or CGS as primary units. (SI units are encouraged.) Englis h units may be used as secondary units (in
parentheses). An exception would be the use of English units as identifiers in trade, such as “3.5-inch disk drive.”
Avoid combining SI and CGS units, such as current in amperes and magnetic field in oersteds. This often leads to confusion
because equations do not balance dimensionally. If you must use mixed units, clearly state the units for each quantity that y ou use
in an equation.
IV. SOME COMMON MISTAKES
The word “data” is plural, not singular. The subscript for the permeability of vacuum 0 is zero, not a lowercase letter “o.” In
American English, periods and commas are within quotation marks, like “this period.” A parenthetical statement at the end of a
sentence is punctuated outside of the closing parenthesis (like this). (A parenthetical sentence is punctuated within the
parentheses.) A graph within a graph is an “inset,” not an “insert.” The word alternatively is preferred to the word “alternately”
(unless you mean something that alternates). Do not use the word “essentially” to mean “approximately” or “effectively.” Be
aware of the different meanings of the homophones “affect” and “effect,” “complement” and “compliment,” “discreet” and
“discrete,” “principal” and “principle.” Do not confuse “imply” and “infer.” The prefix “non” is not a word; it should be joined
to the word it modifies, usually without a hyphen. There is no period after the “et” in the Latin abbreviation “et al.” The
abbreviation “i.e.” means “that is,” and the abbreviation “e.g.” means “for example.” An excellent style manual for science
writers is [7].
ACKNOWLEDGMENT
The preferred spelling of the word “acknowledgment” in America is without an “e” after the “g.” Try to avoid the stilted
expression, “One of us (R. B. G.) thanks …” Instead, try “R.B.G. thanks …” Put sponsor acknowledgments in the unnumbered
footnote on the first page.
REFERENCES
[1] G. Eason, B. Noble, and I.N. Sneddon, “On certain integrals of Lipschitz-Hankel type involving products of Bessel functions,” Phil. Trans. Roy. Soc.
London, vol. A247, pp. 529-551, April 1955.
[2] J. Clerk Maxwell, A Treatise on Electricity and Magnetism, 3rd ed., vol. 2. Oxford: Clarendon, 1892, pp.68-73.
[3] I.S. Jacobs and C.P. Bean, “Fine particles, thin films and exchange anisotropy,” in Magnetism, vol. III, G.T. Rado and H. Suhl, Eds. New York: Academic,
1963, pp. 271-350.
[4] K. Elissa, “Title of paper if known,” unpublished.
[5] R. Nicole, “Title of paper with only first word capitalized,” J. Name Stand. Abbrev., in press.
[6] Y. Yorozu, M. Hirano, K. Oka, and Y. Tagawa, “Electron spectroscopy studies on magneto-optical media and plastic substrate interface,” IEEE Transl. J.
Magn. Japan, vol. 2, pp. 740-741, August 1987 [Digests 9th Annual Conf. Magnetics Japan, p. 301, 1982].
[7] M. Young, The Technical Writer’s Handbook. Mill Valley, CA: University Science, 1989.

You might also like