32 B 3
32 B 3
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 156 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 156 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 5404
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st rru
DKMN17LTE> st mme
$ssh_pid = 6820
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
351 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3001E
352 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3002E
353 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ0902E
354 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ901E
===================================================================================
Total: 4 MOs
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
get /rop/A20221205.1500-1515_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1500-1515_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.......
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
E552671720 20190413 42.5 0.01 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 43.0 0.01 (Radio4428B3)
RRU-3 BXP_2050 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5FA
D82A840665 20200911 44.0 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.6 (32.0) 1.05 (32.8) -102.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 1.1 (30.4) 1.12 (25.2) -101.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.6 (32.0) 1.14 (23.6) -101.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 1.1 (30.5) 1.08 (28.4) -103.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 11 1.2 (30.7) 1.43 (15.0) -100.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 B 11 0.7 (28.5) 1.53 (13.6) -99.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 C 11 1.2 (30.7) 1.35 (16.6) -99.5 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 D 11 0.7 (28.5) 1.32 (17.3) -99.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 - - -101.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 - - -100.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 - - -103.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 0.4 (26.2) - -100.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
..........................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.......
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
E552671720 20190413 44.5 0.01 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 44.0 0.01 (Radio4428B3)
RRU-3 BXP_2050 RRU4428B3 1 ON ON OFF N/A KRC161713/1 R5FA
D82A840665 20200911 45.0 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.0 (30.1) 1.05 (32.8) -102.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.6 (27.5) 1.11 (25.3) -101.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.0 (30.1) 1.14 (23.6) -101.7 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.6 (27.5) 1.08 (28.3) -103.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 11 1.4 (31.5) 1.43 (15.0) -100.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 B 11 0.9 (29.7) 1.53 (13.6) -99.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 C 11 1.4 (31.5) 1.35 (16.6) -99.5 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 D 11 0.9 (29.7) 1.32 (17.2) -99.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
..........................
get /rop/A20221205.1530-1545_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1530-1545_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
E552671720 20190413 46.5 0.01 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 46.0 0.01 (Radio4428B3)
RRU-3 BXP_2050 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5FA
D82A840665 20200911 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.0 (30.1) 1.05 (32.7) -102.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.6 (27.5) 1.11 (25.3) -101.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.0 (30.1) 1.14 (23.6) -101.7 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.6 (27.5) 1.08 (28.3) -102.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 11 1.0 (30.2) 1.43 (15.0) -100.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 B 11 0.6 (27.5) 1.54 (13.5) -99.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 C 11 1.0 (30.2) 1.35 (16.5) -99.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRU4428B3 D 11 0.6 (27.6) 1.32 (17.2) -99.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
$ssh_pid = 3888
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
221207-11:07:12 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/10196
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
421 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
432 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-2
443 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE>
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> cabx
221207-11:09:05 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/10196
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
..........................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
E552671720 20190413 50.0 0.02 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 49.0 0.02 (Radio4428B3)
RRU-3 BXP_2050 RRUS2203B3 1 OFF ON OFF N/A KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.0 (30.1) 1.05 (32.7) -102.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.6 (27.5) 1.11 (25.3) -101.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.0 (30.1) 1.14 (23.6) -101.7 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.6 (27.5) 1.08 (28.4) -102.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 11 1.2 (30.7) 1.44 (14.9) -100.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRU4428B3 B 11 0.7 (28.5) 1.54 (13.5) -99.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRU4428B3 C 11 1.2 (30.7) 1.35 (16.5) -99.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRU4428B3 D 11 0.7 (28.5) 1.32 (17.2) -100.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-3 BXP_2050 RRUS2203B3 A 11 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRUS2203B3 B 11 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
..........................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
E552671720 20190413 51.5 0.02 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 0 ? ? ? N/A KRC161713/1 R11C
E201004079 20200902 (Radio4428B3)
RRU-3 BXP_2050 RRU2203B3 0 ? ? ? N/A KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.3 (31.0) 1.05 (32.6) -102.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.8 (29.0) 1.11 (25.3) -101.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.3 (31.0) 1.14 (23.6) -101.7 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.8 (29.0) 1.08 (28.3) -102.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU2203B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU2203B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st mme
$ssh_pid = 1956
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
351 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3001E
352 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3002E
353 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ0902E
354 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ901E
===================================================================================
Total: 4 MOs
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................
get /rop/A20221206.1000-1015_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221206.1000-1015_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R5A
DU50320707 20180606 (Bb5216)
RRU-2 BXP_2049 RRU2203B3 0 ? ? ? N/A KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
RRU-3 BXP_2050 RRU2219B1 1 OFF ON OFF N/A KRC161622/1 R1E
CD3W826078 20180426 32.8 0.00 (Radio2219B1)
RRU-1 Z??_01 0 ? ? ? ?
SUP Z??_02 SUP6601 1 OFF ON N/A N/A 1/BFL901009/1 R3B
BR81718402 20111207
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
RBS6601 103/BFL901009 R3A CB4L705773 20111216 33 Cabinet=1
FANGROUP OFF
Cabinet=1,FanGroup=1
FANGROUP
Cabinet=1,FanGroup=2
FANGROUP
Cabinet=1,FanGroup=3
FAN03 0 N/A N/A BKV106176/3 SupportUnit=1
(FAN)
PSUAC11 0 ? ? BML901366/1 R3B BR86363058 20190222 SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 98:A4:04:16:01:01 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-2 BXP_2049 RRU2203B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU2203B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU2219B1 A 11 1.2 (30.7) 1.13 (24.6) -102.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU2219B1 B 11 1.2 (30.7) 1.13 (24.6) -102.8 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 8988
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st rru
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
Checking available boards on node...
...................................................................................
...........................................................
get /rop/A20221021.0315-0330_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0315-0330_DKMN17LTE.xml.gz ... OK
get /rop/A20221021.0330-0345_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0330-0345_DKMN17LTE.xml.gz ... OK
get /rop/A20221021.0345-0400_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0345-0400_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R5A/B
DU50320190 20180601 (Bb5216)
RRU-1 BXP_2048 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 -17.2 0.00 (Radio4415B3)
RRU-2 Z??_01 RRU4415B3 0 ? ? ? ? KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
RRU-3 Z??_02 0 ? ? ? ?
SUP Z??_03 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E L 100M_FULL true 98:A4:04:15:CB:D0 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4415B3 A 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 B 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 C 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 D 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 Z??_01 RRU4415B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 7624
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st mme
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell\
DKMN17LTE> \
....
221207-14:54:40 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/444
coli>\
no such command: \
coli>
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
....................................................
get /rop/A20221205.1545-1600_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1545-1600_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 40.5 0.00 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 1 ON ON OFF N/A KRC161713/1 R5FA
E558031327 20200811 37.0 0.00 (Radio4428B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.2 (30.7) 1.13 (24.5) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.7 (28.5) 1.15 (23.3) -99.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.2 (30.7) 1.06 (30.5) -99.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.7 (28.5) 1.11 (25.9) -99.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 B 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 C 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 D 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 16:20:16 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:2757)
2022-12-05 16:20:17 m SFP Not Present
FieldReplaceableUnit=1,SfpModule=C (No SFP or electrical cable plugged in.)
2022-12-05 16:22:13 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:2819)
2022-12-05 16:23:46 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 16:23:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 16:23:50 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 16:23:50 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 16:24:48 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 16:25:46 M Resource Activation Timeout EUtranCellFDD=DKMN17C_LTE
(Resource Activation Timeout)
2022-12-05 16:26:17 m Service Degraded EUtranCellFDD=DKMN17B_LTE
(The alarm is currently toggling.)
2022-12-05 16:26:27 m HW Fault FieldReplaceableUnit=RRU-
2 (Not functional carrier HW resources [ DL/A DL/B DL/C DL/D ])
2022-12-05 16:26:27 M Service Unavailable EUtranCellFDD=DKMN17B_LTE
(UnderlyingResourceUnavailable)
>>> Total: 12 Alarms (1 Critical, 3 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 42.5 0.00 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5FA
E558031327 20200811 (Radio4428B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.0 (30.2) 1.13 (24.5) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.6 (27.5) 1.15 (23.3) -99.5 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.0 (30.2) 1.06 (30.5) -99.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.6 (27.6) 1.11 (25.9) -99.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 2704
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 45.5 0.00 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5FA
E558031327 20200811 (Radio4428B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.2 (30.7) 1.13 (24.5) -99.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.7 (28.5) 1.15 (23.3) -99.5 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.2 (30.7) 1.06 (30.1) -99.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.7 (28.5) 1.11 (25.9) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 46.5 0.00 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5FA
E558031327 20200811 (Radio4428B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.3 (31.1) 1.13 (24.5) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.8 (29.1) 1.15 (23.3) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.3 (31.1) 1.06 (30.1) -98.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.8 (29.1) 1.11 (25.9) -98.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 7440
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 51.5 0.01 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5FA
E558031327 20200811 (Radio4428B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.7 (32.2) 1.13 (24.5) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 1.2 (30.8) 1.15 (23.3) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.7 (32.3) 1.07 (29.9) -99.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 1.2 (30.8) 1.11 (26.0) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 52.0 0.01 (Radio4428B3)
RRU-2 BXP_2049 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5FA
E558031327 20200811 (Radio4428B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.2 (30.7) 1.13 (24.5) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.7 (28.5) 1.15 (23.3) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.2 (30.7) 1.07 (29.9) -99.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.7 (28.5) 1.11 (26.0) -99.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU4428B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU4428B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st cell
221207-15:14:58 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/444
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 53.0 0.01 (Radio4428B3)
RRU-2 BXP_2049 RRUS2203B3 1 OFF ON OFF N/A KRC161488/1 R1F
TD3R189463 20200724 62.2 0.00 (Radio2203B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
FAN03 1 N/A N/A BKV106176/3 SupportUnit=1
(FAN)
PSUAC11 1 OFF ON BML901366/1 R3B BR86363058 20190222 SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.0 (30.2) 1.13 (24.5) -99.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.6 (27.5) 1.15 (23.3) -99.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.0 (30.2) 1.07 (30.0) -99.0 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.6 (27.6) 1.11 (26.0) -99.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS2203B3 A 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS2203B3 B 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
...
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 53.5 0.01 (Radio4428B3)
RRU-2 BXP_2049 RRUS2203B3 1 OFF ON OFF N/A KRC161488/1 R1F
TD3R189463 20200724 (Radio2203B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
FAN03 1 N/A N/A BKV106176/3 SupportUnit=1
(FAN)
PSUAC11 1 OFF ON BML901366/1 R3B BR86363058 20190222 SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.0 (30.2) 1.13 (24.5) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.6 (27.5) 1.15 (23.3) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.0 (30.2) 1.07 (30.0) -98.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.6 (27.6) 1.11 (26.0) -98.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS2203B3 A 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS2203B3 B 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 5564
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
get /rop/A20221205.1630-1645_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1630-1645_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 53.5 0.02 (Radio4428B3)
RRU-2 BXP_2049 RRUS2203B3 0 ? ? ? N/A KRC161488/1 R1F
TD3R189463 20200724 (Radio2203B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
FAN03 0 N/A N/A BKV106176/3 SupportUnit=1
(FAN)
PSUAC11 0 ? ? BML901366/1 R3B BR86363058 20190222 SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.4 (31.5) 1.13 (24.5) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.9 (29.7) 1.15 (23.3) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.4 (31.5) 1.07 (30.0) -99.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.9 (29.7) 1.11 (26.0) -99.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS2203B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS2203B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 2076
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 54.5 0.02 (Radio4428B3)
RRU-2 BXP_2049 RRU2203B3 0 ? ? ? N/A KRC161488/1 R1F
TD3R189463 20200724 (Radio2203B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
FAN03 0 N/A N/A BKV106176/3 SupportUnit=1
(FAN)
PSUAC11 0 ? ? BML901366/1 R3B BR86363058 20190222 SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.4 (31.5) 1.13 (24.5) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.9 (29.7) 1.15 (23.3) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.4 (31.5) 1.07 (30.0) -99.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.9 (29.7) 1.11 (26.0) -99.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU2203B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU2203B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 9212
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R11C
E201004079 20200902 55.0 0.02 (Radio4428B3)
RRU-2 BXP_2049 RRU2203B3 0 ? ? ? N/A KRC161488/1 R1F
TD3R189463 20200724 (Radio2203B3)
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
FAN03 0 N/A N/A BKV106176/3 SupportUnit=1
(FAN)
PSUAC11 0 ? ? BML901366/1 R3B BR86363058 20190222 SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4428B3 A 11 1.0 (30.2) 1.13 (24.5) -99.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 B 11 0.6 (27.5) 1.15 (23.3) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 C 11 1.0 (30.2) 1.07 (30.0) -99.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRU4428B3 D 11 0.6 (27.6) 1.10 (26.1) -99.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRU2203B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRU2203B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 9432
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st rru
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 804
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st rru
$ssh_pid = 10184
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
392 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
403 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-2
414 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
...........................................................
get /rop/A20221021.0500-0515_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0500-0515_DKMN17LTE.xml.gz ... OK
get /rop/A20221021.0515-0530_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0515-0530_DKMN17LTE.xml.gz ... OK
get /rop/A20221021.0530-0545_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0530-0545_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R5A/B
DU50320190 20180601 (Bb5216)
RRU-1 BXP_2048 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 43.8 0.00 (Radio4415B3)
RRU-2 Z??_01 RRU4415B3 0 ? ? ? ? KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
RRU-3 Z??_02 0 ? ? ? ?
SUP Z??_03 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E L 100M_FULL true 98:A4:04:15:CB:D0 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4415B3 A 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 B 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 C 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 D 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 Z??_01 RRU4415B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 2012
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
..............................................
get /rop/A20221021.0545-0600_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0545-0600_DKMN17LTE.xml.gz ... OK
get /rop/A20221021.0600-0615_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221021.0600-0615_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R5A/B
DU50320190 20180601 (Bb5216)
RRU-1 BXP_2048 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 43.8 0.00 (Radio4415B3)
RRU-2 Z??_01 RRU4415B3 0 ? ? ? ? KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
RRU-3 Z??_02 0 ? ? ? ?
SUP Z??_03 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E L 100M_FULL true 98:A4:04:15:CB:D0 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRU4415B3 A 01 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 B 01 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 C 01 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRU4415B3 D 01 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 Z??_01 RRU4415B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRU4415B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 12116
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
$ssh_pid = 772
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
351 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3001E
352 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3002E
353 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ0902E
354 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ901E
===================================================================================
Total: 4 MOs
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
....................................................
get /rop/A20221205.1645-1700_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1645-1700_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V079796 20161111
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 32.6 0.00
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.9 (32.8) 1.13 (24.3) -101.2 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.4 (31.6) 1.13 (24.4) -101.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.1 (30.3) 1.11 (25.8) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.8) 1.17 (21.9) -101.5 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
$ssh_pid = 6132
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 38.0 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 36.8 0.00
RRU-3 Z??_01 RRU2203B3 0 ? ? ? ? KRC161488/1 R1E
TD3R055458 20180510 (Radio2203B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.4 (31.5) 1.19 (21.1) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.9 (29.7) 1.10 (26.3) -101.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.21 (20.6) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.15 (23.2) -101.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.13 (24.3) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.13 (24.4) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.3) 1.11 (25.8) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.9 (29.5) 1.17 (22.0) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 Z??_01 RRU2203B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU2203B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st ruu
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 41.1 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 40.3 0.00
RRU-3 BXP_2050 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
D828778501 20190311 35.5 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.4 (31.3) 1.18 (21.8) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.9 (29.5) 1.10 (26.6) -101.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.21 (20.6) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.13 (24.2) -101.7 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.9 (32.8) 1.13 (24.5) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.4 (31.6) 1.13 (24.3) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.4) 1.11 (25.7) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.9 (29.5) 1.17 (22.1) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 1.4 (31.6) 1.06 (30.6) -102.1 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 1.0 (29.8) 1.06 (30.8) -101.9 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 1.7 (32.2) 1.07 (29.5) -102.1 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 1.1 (30.4) 1.10 (26.4) -100.4 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 8164
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 44.1 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 43.5 0.00
RRU-3 BXP_2050 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
D828778501 20190311 38.5 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.2 (30.7) 1.19 (21.2) -99.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.7 (28.5) 1.11 (26.0) -100.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.4 (31.5) 1.21 (20.6) -100.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.9 (29.7) 1.15 (23.3) -101.7 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.13 (24.3) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.13 (24.3) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.11 (25.7) -97.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.17 (22.0) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 1.0 (30.1) 1.06 (30.7) -101.5 2 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 0.6 (27.5) 1.06 (30.5) -100.7 2 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 1.1 (30.6) 1.07 (29.4) -101.8 2 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 0.7 (28.1) 1.10 (26.4) -101.2 2 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 45.8 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 45.3 0.01
RRU-3 BXP_2050 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
D828778501 20190311 40.0 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.20 (21.0) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.11 (26.0) -88.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.21 (20.6) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.7 (28.5) 1.15 (23.2) -101.7 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.13 (24.4) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.13 (24.3) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.11 (25.7) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.17 (22.3) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 - - -102.5 1 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 - - -101.8 1 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 - 1.07 (29.4) -102.5 1 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 - - -102.0 1 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:26 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/D ])
2022-12-05 17:29:33 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:32 m Linearization Disturbance Performance Degraded
FieldReplaceableUnit=RRU-3 (Linearization fault [ DL/C ])
2022-12-05 17:29:33 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:32 m Linearization Disturbance Performance Degraded
FieldReplaceableUnit=RRU-3 (Linearization fault [ DL/C ])
2022-12-05 17:29:33 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 17:29:44 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ DL/C DL/D ])
2022-12-05 17:29:50 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 49.1 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 48.4 0.01
RRU-3 BXP_2050 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5C
D828778501 20190311 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.7 (32.2) 1.18 (21.5) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.2 (30.8) 1.10 (26.5) -101.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.20 (20.9) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.13 (24.2) -101.7 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.13 (24.5) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.13 (24.3) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.11 (25.7) -100.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.17 (22.0) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 7608
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
get /rop/A20221205.1715-1730_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1715-1730_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 52.1 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 51.3 0.01
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 40.5 0 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.3 (31.0) 1.19 (21.4) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.8 (29.0) 1.11 (26.0) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.20 (21.0) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.7 (28.5) 1.13 (24.1) -101.7 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.13 (24.6) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.13 (24.3) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.5 (31.8) 1.11 (25.6) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 1.0 (30.1) 1.17 (21.9) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 1.4 (31.4) 1.08 (28.0) -99.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 0.9 (29.6) 1.15 (23.4) -98.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 1.4 (31.4) 1.12 (25.2) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 0.9 (29.6) 1.16 (22.8) -99.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 54.6 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 53.9 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 43.6 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.8 (32.5) 1.20 (20.9) -101.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.3 (31.2) 1.10 (26.3) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.4 (31.3) 1.21 (20.6) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.9 (29.4) 1.15 (23.4) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.15 (23.1) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.13 (24.2) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.11 (25.6) -100.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.17 (22.1) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.08 (28.0) -99.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.5) 1.15 (23.3) -92.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.1) 1.12 (25.1) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.5) 1.16 (22.8) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 7216
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 57.0 0.02
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V320488 20161209 56.5 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 47.1 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.6 (32.0) 1.19 (21.1) -101.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.1 (30.5) 1.11 (25.9) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.19 (21.4) -100.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.13 (24.1) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.15 (23.1) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.13 (24.2) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.11 (25.6) -100.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.17 (22.3) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.8 (32.5) 1.08 (27.9) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 1.3 (31.2) 1.15 (23.3) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.8 (32.5) 1.12 (25.1) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 1.3 (31.2) 1.16 (22.7) -99.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st rru
$ssh_pid = 11748
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
421 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
432 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-2
443 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cel
DKMN17LTE> st cel
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> alt
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
get /rop/A20221205.1730-1745_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1730-1745_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 37.6 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 37.7 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 54.2 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.19 (21.2) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.22 (20.0) -101.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.10 (26.8) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 - - -101.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.3 (31.0) 1.09 (26.9) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.8 (29.0) 1.11 (25.5) -101.6 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.19 (21.4) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.14 (23.8) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.09 (27.7) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.5) 1.16 (22.7) -98.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.1) 1.12 (25.0) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.5) 1.16 (22.7) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
DKMN17LTE> alt
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 40.3 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 40.8 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 55.8 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.3 (31.0) 1.18 (21.7) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.8 (29.0) 1.23 (19.8) -99.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.4 (31.5) 1.10 (26.8) -100.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 - - -101.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.3 (31.0) 1.09 (26.9) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.8 (29.0) 1.11 (25.3) -101.5 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.19 (21.4) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.14 (23.9) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.9 (32.7) 1.09 (27.7) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 1.4 (31.5) 1.16 (22.6) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.9 (32.7) 1.12 (25.0) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 1.4 (31.5) 1.16 (22.6) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 11840
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16W962884 20170725
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 47.3 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 59.1 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.10 (26.8) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (25.5) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.3 (31.0) 1.19 (21.4) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.8 (29.0) 1.13 (24.0) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.09 (27.5) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.5) 1.16 (22.6) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.1) 1.12 (24.9) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.5) 1.16 (22.6) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
221208-11:12:37 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/9788
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V308810 20161208 35.9 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 49.1 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 60.1 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 01 1.7 (32.3) 1.17 (22.1) -101.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 01 1.2 (30.8) 1.19 (21.4) -102.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 01 1.0 (30.2) 1.10 (26.2) -112.5 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 01 0.6 (27.6) 1.14 (23.6) -102.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 2.0 (33.0) 1.10 (26.8) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.5 (31.8) 1.11 (25.4) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.3) 1.18 (21.5) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.9 (29.5) 1.14 (23.9) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.09 (27.5) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.4) 1.16 (22.6) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.6) 1.12 (24.9) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.16 (22.6) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
$ssh_pid = 7264
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.......................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 39.6 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 51.8 0.01
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.17 (22.0) -99.8 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.19 (21.3) -101.1 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.8 (32.5) 1.10 (26.1) -112.2 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.3 (31.2) 1.15 (23.3) -102.1 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.10 (26.7) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (25.5) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.9 (32.8) 1.18 (21.6) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 1.4 (31.6) 1.13 (24.0) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
221208-11:17:25 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/9788
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
get /rop/A20221205.1745-1800_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1745-1800_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 42.0 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 53.2 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B440989505 20180122 43.0 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.19 (21.3) -101.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.19 (21.4) -102.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.4 (31.3) 1.10 (26.1) -112.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.9 (29.5) 1.15 (23.4) -102.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.10 (26.7) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (25.5) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.5) 1.18 (21.5) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.9 (29.7) 1.14 (23.9) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.16 (22.5) -102.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.5) 1.18 (21.6) -102.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.1) 1.02 (38.6) -99.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.5) 1.16 (22.6) -98.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 9816
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 46.2 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 55.5 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B440989505 20180122 46.2 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.2 (30.7) 1.20 (20.9) -101.7 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.7 (28.5) 1.19 (21.4) -102.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.11 (26.0) -112.0 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.7 (28.5) 1.15 (23.2) -102.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.10 (26.7) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.11 (25.4) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.3 (31.0) 1.18 (21.5) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.8 (29.0) 1.13 (24.1) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.1 (30.6) 1.16 (22.5) -102.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.5) 1.18 (21.5) -102.2 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.7) 1.02 (38.6) -99.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.16 (22.7) -98.8 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 47.8 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 56.3 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B440989505 20180122 47.6 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.5 (31.8) 1.20 (20.9) -100.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.0 (30.1) 1.19 (21.4) -102.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.9 (32.8) 1.11 (26.0) -112.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.4 (31.6) 1.14 (23.5) -102.0 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.4 (31.3) 1.10 (26.7) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.9 (29.5) 1.11 (25.4) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.18 (21.5) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.13 (24.1) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.1 (30.6) 1.16 (22.4) -102.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.5) 1.18 (21.5) -102.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.7) 1.02 (38.4) -99.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.16 (22.7) -98.8 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:11:36 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ UL/A UL/B ])
2022-12-05 18:11:40 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:11:36 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ UL/A UL/B ])
2022-12-05 18:11:40 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 51.3 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 58.2 0.01
RRU-3 BXP_2050 RRU4415B3 1 ON ON OFF N/A KRC161637/1 R1C
B440989505 20180122 50.8 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.2 (30.7) 1.20 (20.9) -101.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.7 (28.5) 1.19 (21.4) -102.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.1 (30.4) 1.11 (26.0) -111.9 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.9) 1.14 (23.5) -102.0 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.4 (31.5) 1.10 (26.7) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.9 (29.7) 1.11 (25.4) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.18 (21.5) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.13 (24.0) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.16 (22.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.6) 1.18 (21.5) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.2) 1.02 (38.3) -99.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.5) 1.16 (22.6) -98.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
221208-11:28:42 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/9788
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:11:36 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ UL/A UL/B ])
2022-12-05 18:11:40 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:11:36 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ UL/A UL/B ])
2022-12-05 18:11:40 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 54.1 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 59.9 0.02
RRU-3 BXP_2050 RRU4415B3 1 ON ON OFF N/A KRC161637/1 R1C
B440989505 20180122 53.7 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 2.4 (33.8) 1.19 (21.4) -101.7 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.9 (32.8) 3.16 (5.7) -100.9 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.1 (30.3) 1.11 (26.0) -111.9 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.7) 1.15 (23.3) -101.9 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.3 (31.0) 1.10 (26.6) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.8 (29.0) 1.11 (25.4) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 2.0 (33.0) 1.18 (21.6) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 1.5 (31.8) 1.14 (23.8) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.16 (22.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.5) 1.19 (21.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.7) 1.03 (38.0) -99.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.16 (22.6) -98.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
get /rop/A20221205.1800-1815_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1800-1815_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 55.5 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W894216 20170706 60.7 0.02
RRU-3 BXP_2050 RRU4415B3 1 ON ON OFF N/A KRC161637/1 R1C
B440989505 20180122 55.0 0.00 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.20 (20.9) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.18 (21.8) -102.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 2.4 (33.7) 1.11 (25.9) -111.7 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.9 (32.7) 1.14 (23.5) -101.9 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.10 (26.6) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (25.4) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.19 (21.4) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.14 (23.9) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.16 (22.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.5) 1.19 (21.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.7) 1.02 (38.3) -99.0 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.16 (22.6) -98.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 11664
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308810 20161208 57.0 0.01
RRU-2 BXP_2049 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16W894216 20170706
RRU-3 BXP_2050 RRU4415B3 1 ON ON OFF N/A KRC161637/1 R1C
B440989505 20180122 56.6 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.7 (32.4) 1.20 (21.0) -101.6 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.3 (31.0) 1.18 (21.8) -101.4 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 7.4 (38.7) 1.11 (25.9) -111.7 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 6.9 (38.4) 1.15 (23.4) -101.8 2 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.16 (22.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.5) 1.19 (21.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.7) 1.03 (37.9) -99.0 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.16 (22.6) -98.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:11:36 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ UL/A UL/B ])
2022-12-05 18:11:40 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
2022-12-05 18:23:34 m Power Loss FieldReplaceableUnit=RRU-
1 (Power Failure Alarm (PFA).)
2022-12-05 18:23:34 M Service Unavailable EUtranCellFDD=DKMN17A_LTE
(UnderlyingResourceUnavailable)
>>> Total: 11 Alarms (1 Critical, 2 Major)
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V308810 20161208
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 37.4 0.00
RRU-3 BXP_2050 RRU4415B3 1 ON ON OFF N/A KRC161637/1 R1C
B440989505 20180122 58.2 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.7 (32.3) 1.07 (28.9) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.2 (30.8) 1.13 (24.6) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.5 (31.8) 1.21 (20.6) -103.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 1.0 (30.1) - -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.17 (22.3) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.5) 1.19 (21.4) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.2) 1.03 (37.7) -99.0 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.5) 1.16 (22.6) -98.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:11:36 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ UL/A UL/B ])
2022-12-05 18:11:40 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
2022-12-05 18:23:34 m Power Loss FieldReplaceableUnit=RRU-
1 (Power Failure Alarm (PFA).)
2022-12-05 18:23:34 M Service Unavailable EUtranCellFDD=DKMN17A_LTE
(UnderlyingResourceUnavailable)
>>> Total: 11 Alarms (1 Critical, 2 Major)
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st cell
221208-11:40:11 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/9788
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 37.1 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 40.8 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.9 (32.8) 1.22 (20.1) -101.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.4 (31.6) 1.12 (24.9) -101.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.29 (18.0) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.20 (20.9) -101.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.07 (28.9) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.12 (24.7) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.7 (32.3) 1.21 (20.6) -102.7 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 1.2 (30.8) - -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st rru
$ssh_pid = 10936
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
421 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
432 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-2
443 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> st rru
DKMN17LTE> st rru\
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
221208-11:46:42 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/9788
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
Checking available boards on node...
...................................................................................
........................................
get /rop/A20221205.1815-1830_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1815-1830_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 45.9 0.00
RRU-2 BXP_2049 RRUS32B3 1 ON ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 37.8 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.3 (31.0) 1.22 (20.0) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.8 (29.0) 1.12 (24.8) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.3) 1.27 (18.5) -101.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.2 (30.8) 1.19 (21.1) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 - - -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.0 (30.2) 1.12 (24.9) -101.5 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.3 (31.1) 1.30 (17.7) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 - - -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:27:01 M Service Unavailable EUtranCellFDD=DKMN17C_LTE
(UnderlyingResourceUnavailable)
2022-12-05 18:27:04 m Power Loss FieldReplaceableUnit=RRU-
3 (Power Failure Alarm (PFA).)
2022-12-05 18:34:24 m HW Fault FieldReplaceableUnit=RRU-
2 (Not functional carrier HW resources [ DL/A ])
2022-12-05 18:34:33 m Service Degraded EUtranCellFDD=DKMN17B_LTE
(PerformanceDegraded)
>>> Total: 11 Alarms (1 Critical, 2 Major)
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:27:01 M Service Unavailable EUtranCellFDD=DKMN17C_LTE
(UnderlyingResourceUnavailable)
2022-12-05 18:27:04 m Power Loss FieldReplaceableUnit=RRU-
3 (Power Failure Alarm (PFA).)
2022-12-05 18:36:37 m Power Loss FieldReplaceableUnit=RRU-
2 (Power Failure Alarm (PFA).)
2022-12-05 18:37:06 M Service Unavailable EUtranCellFDD=DKMN17B_LTE
(UnderlyingResourceUnavailable)
>>> Total: 11 Alarms (1 Critical, 3 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 49.7 0.00
RRU-2 BXP_2049 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V325039 20161210
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.3 (31.0) 1.22 (20.2) -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.8 (29.0) 1.12 (24.8) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.3) 1.27 (18.5) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.2 (30.8) 1.20 (20.9) -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 17:12:25 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3046)
2022-12-05 17:12:30 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3087)
2022-12-05 17:15:50 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:50 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 17:15:52 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 17:15:52 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 17:16:50 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 18:27:01 M Service Unavailable EUtranCellFDD=DKMN17C_LTE
(UnderlyingResourceUnavailable)
2022-12-05 18:27:04 m Power Loss FieldReplaceableUnit=RRU-
3 (Power Failure Alarm (PFA).)
>>> Total: 9 Alarms (1 Critical, 2 Major)
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 51.8 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 37.5 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 11.2 (40.5) 1.21 (20.4) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 10.7 (40.3) 1.12 (24.8) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.5 (31.7) 1.27 (18.6) -101.0 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.0 (30.0) 1.20 (20.8) -101.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.5 (31.8) 1.09 (27.1) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.0 (30.1) 1.24 (19.3) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.10 (26.5) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.10 (26.6) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 53.3 0.01
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 39.7 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.5 (31.6) 1.23 (19.9) -101.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.0 (29.9) 1.12 (24.8) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.3) 1.27 (18.5) -101.0 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.2 (30.8) 1.19 (21.2) -101.1 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.4 (31.3) 1.09 (27.1) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.9 (29.5) 1.25 (19.2) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.5) 1.10 (26.4) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.9 (29.7) 1.09 (26.9) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V308753 20161208
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 42.4 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.09 (27.1) -101.2 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.14 (23.5) -101.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.11 (26.0) -101.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.09 (26.9) -101.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> cabx
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 55.8 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 45.6 0.00
RRU-3 BXP_2050 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5C
D828778501 20190311 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.2 (30.7) 1.21 (20.3) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.7 (28.5) 1.12 (24.7) -98.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.24 (19.4) -100.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.20 (20.8) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 2.9 (34.6) 1.09 (27.1) -99.6 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 2.4 (33.8) 1.23 (19.9) -100.9 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 3.7 (35.7) 1.10 (26.6) -101.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 3.2 (35.1) 1.10 (26.8) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
DKMN17LTE> cabx
221208-12:00:25 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/9788
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 56.7 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 47.6 0.00
RRU-3 BXP_2050 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
D828778501 20190311 43.0 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 2.3 (33.7) 1.21 (20.4) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.9 (32.7) 1.12 (24.7) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 2.1 (33.3) 1.24 (19.3) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.6 (32.2) 1.21 (20.5) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.1 (30.6) 1.09 (27.1) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.3) 1.43 (15.1) -101.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.10 (26.6) -101.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.10 (26.8) -101.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 1.0 (30.2) 1.06 (30.1) -102.0 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 0.6 (27.5) 1.11 (25.8) -92.6 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 1.4 (31.6) 1.08 (28.6) -101.9 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 0.8 (29.0) 1.08 (28.4) -101.9 1 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
get /rop/A20221205.1830-1845_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1830-1845_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 57.8 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 49.4 0.00
RRU-3 BXP_2050 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
D828778501 20190311 44.5 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.21 (20.3) -100.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.12 (24.7) -93.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.24 (19.4) -99.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.7 (28.5) 1.21 (20.5) -81.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.09 (27.0) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.71 (11.6) -101.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.10 (26.1) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.10 (26.8) -101.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 1.0 (30.1) 1.07 (30.0) -102.0 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 0.6 (27.5) 1.11 (25.8) -101.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 1.1 (30.6) 1.08 (28.7) -101.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 0.6 (27.9) 1.08 (28.4) -101.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 59.1 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 51.4 0.00
RRU-3 BXP_2050 RRU4428B3 1 OFF ON OFF N/A KRC161713/1 R5C
D828778501 20190311 46.5 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.7 (32.3) 1.21 (20.4) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.2 (30.8) 1.12 (24.7) -97.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.4 (31.3) 1.24 (19.4) -90.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.9 (29.5) 1.21 (20.5) -91.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.7 (32.3) 1.09 (27.0) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.2 (30.8) 1.68 (11.9) -101.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.3) 1.11 (26.0) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.9 (29.5) 1.10 (26.8) -101.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 1.3 (31.0) 1.07 (30.0) -102.0 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 0.8 (29.0) 1.11 (25.8) -101.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 1.9 (32.8) 1.08 (28.8) -101.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 1.2 (30.7) 1.08 (28.5) -101.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V308753 20161208 60.5 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 53.3 0.01
RRU-3 BXP_2050 RRU4428B3 1 ON ON OFF N/A KRC161713/1 R5C
D828778501 20190311 48.0 0.00 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.23 (19.7) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.12 (24.7) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.24 (19.5) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.21 (20.6) -100.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.7 (32.3) 1.09 (27.0) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.2 (30.8) 1.71 (11.6) -101.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.10 (26.5) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.10 (26.8) -101.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 11 1.2 (30.7) 1.07 (30.0) -102.0 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 B 11 1.2 (30.7) 1.11 (25.7) -101.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 C 11 - - -101.9 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4428B3 D 11 - - -101.8 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 9976
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V308753 20161208
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 56.3 0.01
RRU-3 BXP_2050 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5C
D828778501 20190311 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.7 (32.3) 1.09 (27.0) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.2 (30.8) 1.71 (11.6) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.6 (32.0) 1.10 (26.4) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 1.1 (30.5) 1.10 (26.7) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
$ssh_pid = 6012
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W964020 20170725 39.7 0.00
RRU-2 BXP_2049 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16W848885 20170622 58.8 0.00
RRU-3 BXP_2050 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5C
D828778501 20190311 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.4 (31.5) 1.19 (21.3) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.9 (29.7) 1.11 (26.0) -103.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.4) 1.26 (18.9) -101.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.3 (31.1) 1.26 (18.8) -100.0 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 01 1.9 (32.8) 1.09 (27.0) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 B 01 1.4 (31.6) 1.69 (11.8) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 C 01 1.0 (30.2) 1.09 (27.1) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 D 01 0.6 (27.6) 1.10 (26.7) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4428B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 9308
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
get /rop/A20221205.1845-1900_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1845-1900_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W964020 20170725 45.5 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W848885 20170622 60.6 0.00
RRU-3 BXP_2050 RRU4428B3 0 ? ? ? N/A KRC161713/1 R5C
D828778501 20190311 (Radio4428B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.3 (31.0) 1.18 (21.7) -101.2 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.8 (29.0) 1.11 (25.9) -103.7 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.4 (31.5) 1.26 (18.9) -101.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.9 (29.7) 1.21 (20.4) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.28 (18.2) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (25.4) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.09 (27.1) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.10 (26.7) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4428B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4428B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 12880
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st mme
$ssh_pid = 252
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
352 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3001E
353 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3002E
354 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ0902E
355 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ901E
===================================================================================
Total: 4 MOs
DKMN17LTE> st cell
$ssh_pid = 6128
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.....................................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B440989505 20180122 47.8 0.00 (Radio4415B3)
RRU-1 Z??_01 RRUS32B3 0 ? ? ? ? KRC161413/1 R1D
D16W964020 20170725
RRU-2 Z??_02 RRUS32B3 0 ? ? ? ? KRC161413/1 R1D
D16W848885 20170622
SUP Z??_03 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 Z??_01 RRUS32B3 A 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 Z??_01 RRUS32B3 B 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 Z??_01 RRUS32B3 C 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 Z??_01 RRUS32B3 D 00 - - - SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 Z??_02 RRUS32B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_02 RRUS32B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_02 RRUS32B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_02 RRUS32B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 2.1 (33.1) 1.08 (28.4) -102.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 1.6 (32.1) 1.07 (29.4) -102.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 2.1 (33.2) 1.10 (26.2) -99.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 1.6 (32.1) 1.13 (24.6) -98.8 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st mme
$ssh_pid = 7000
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
352 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3001E
353 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3002E
354 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ0902E
355 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ901E
===================================================================================
Total: 4 MOs
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st mme
DKMN17LTE> st rru
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
221208-14:34:52 169.254.2.2 19.0n stopfile=/tmp/5800
Please enter Username: rbs
Please enter rbs's Node Password:
$ssh_pid = 2032
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st mme
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.....................................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 40.9 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B440989505 20180122 52.2 0.00 (Radio4415B3)
RRU-2 Z??_01 RRUS32B3 0 ? ? ? ? KRC161413/1 R1D
D16W848885 20170622
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.62 (12.5) -100.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.12 (25.1) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.3 (31.0) 1.10 (26.7) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.8 (29.0) 1.11 (25.9) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 Z??_01 RRUS32B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.9 (32.9) 1.08 (28.4) -102.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 1.5 (31.8) 1.07 (29.3) -102.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 2.0 (33.0) 1.10 (26.2) -99.0 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 1.5 (31.7) 1.13 (24.5) -98.7 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 12948
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 44.3 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B440989505 20180122 (Radio4415B3)
RRU-2 Z??_01 RRUS32B3 0 ? ? ? ? KRC161413/1 R1D
D16W848885 20170622
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.69 (11.8) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.12 (25.1) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.8 (32.5) 1.12 (24.8) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.3 (31.2) 1.14 (23.8) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 Z??_01 RRUS32B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 48.9 0.00
RRU-3 BXP_2050 RRU4415B3 1 ON ON OFF N/A KRC161637/1 R1C
B440989505 20180122 56.9 0.00 (Radio4415B3)
RRU-2 Z??_01 RRUS32B3 0 ? ? ? ? KRC161413/1 R1D
D16W848885 20170622
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 2.4 (33.9) 1.22 (20.1) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 2.0 (32.9) 1.12 (25.0) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.3) 1.11 (25.5) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.2 (30.8) 1.13 (24.3) -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 Z??_01 RRUS32B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.9) 1.08 (28.3) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.8 (29.0) 1.07 (29.2) 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.3 (31.0) 1.10 (26.1) -98.8 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.8 (28.9) 1.13 (24.6) -98.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (D:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 19:35:45 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3508)
2022-12-05 19:35:45 m SFP Not Present
FieldReplaceableUnit=1,SfpModule=B (No SFP or electrical cable plugged in.)
2022-12-05 19:35:57 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3557)
2022-12-05 19:39:23 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 19:39:24 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 19:40:24 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 19:41:08 M Resource Activation Timeout EUtranCellFDD=DKMN17B_LTE
(Resource Activation Timeout)
2022-12-05 19:46:18 m HW Fault FieldReplaceableUnit=RRU-
3 (Not functional carrier HW resources [ UL/A UL/B ])
2022-12-05 19:46:23 m Service Degraded EUtranCellFDD=DKMN17C_LTE
(PerformanceDegraded)
>>> Total: 11 Alarms (1 Critical, 2 Major)
DKMN17LTE> st cell
$ssh_pid = 2464
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 45.2 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 51.5 0.00 (Radio4415B3)
RRU-2 Z??_01 RRUS32B3 0 ? ? ? ? KRC161413/1 R1D
D16W848885 20170622
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.15 (23.1) -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.21 (20.5) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.11 (25.4) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.7 (28.5) 1.12 (25.2) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 Z??_01 RRUS32B3 A 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 B 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 C 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 Z??_01 RRUS32B3 D 00 - - - SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.15 (23.2) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.4) 1.13 (24.5) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.6) 1.09 (27.6) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.15 (23.1) -99.6 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
$ssh_pid = 12804
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
get /rop/A20221205.1945-2000_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.1945-2000_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 ON ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 39.0 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 44.5 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 63.1 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 - - -101.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (D:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.0 (30.2) 1.12 (24.9) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (D:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.13 (24.4) -101.3 1 SE=1 AG=1
FDD=DKMN17A_LTE (D:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 - - -101.4 1 SE=1 AG=1
FDD=DKMN17A_LTE (D:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 2.1 (33.3) 1.17 (22.2) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.6 (32.2) 1.20 (20.8) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.3 (31.0) 1.18 (21.8) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.8 (29.0) 1.24 (19.3) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.9) 1.15 (23.0) -99.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.8 (28.9) 1.13 (24.2) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (31.0) 1.09 (27.4) -99.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.8 (28.9) 1.15 (23.1) -99.5 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 19:35:45 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3508)
2022-12-05 19:35:57 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3557)
2022-12-05 19:39:23 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 19:39:24 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 19:40:24 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 20:10:32 m HW Fault FieldReplaceableUnit=RRU-
1 (Not functional carrier HW resources [ DL/A ])
2022-12-05 20:10:43 m Service Degraded EUtranCellFDD=DKMN17A_LTE
(PerformanceDegraded)
>>> Total: 9 Alarms (1 Critical, 1 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V325039 20161210
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 46.1 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 64.1 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.17 (21.9) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.21 (20.5) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.17 (22.3) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.23 (19.9) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.15 (23.0) -99.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.5) 1.13 (24.2) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.1) 1.09 (27.4) -99.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.5) 1.15 (23.1) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 10572
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
get /rop/A20221205.2000-2015_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.2000-2015_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 42.6 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 52.8 0.00
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 68.7 0.01 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 - - -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.7 (28.5) 1.21 (20.4) -101.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 2.4 (33.7) 1.18 (21.6) -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.9 (32.7) 1.12 (25.1) -101.3 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.17 (22.2) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.21 (20.5) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.17 (22.1) -100.9 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.23 (19.9) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.15 (23.0) -99.2 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.4) 1.13 (24.0) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.6) 1.09 (27.2) -99.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.15 (23.1) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 19:35:45 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3508)
2022-12-05 19:35:57 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3557)
2022-12-05 19:39:23 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 19:39:24 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 19:40:24 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> alt
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 19:35:45 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3508)
2022-12-05 19:35:57 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3557)
2022-12-05 19:39:23 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 19:39:24 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 19:40:24 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 45.3 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 54.7 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 70.0 0.02 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 - - -101.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.3 (31.2) 1.21 (20.4) -101.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.0 (30.2) 1.19 (21.4) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.6 (27.6) 1.11 (25.4) -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.9 (32.8) 1.17 (21.9) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.4 (31.6) 1.21 (20.5) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.17 (21.9) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.22 (20.1) -101.1 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.15 (22.9) -99.2 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.4) 1.13 (24.0) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.6) 1.09 (27.2) -99.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.15 (23.0) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
.
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 19:35:45 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3508)
2022-12-05 19:35:57 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3557)
2022-12-05 19:39:23 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 19:39:24 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 19:40:24 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
>>> Total: 7 Alarms (1 Critical, 1 Major)
DKMN17LTE> st cell
$ssh_pid = 7200
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
........
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 39.1 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 57.2 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 71.8 0.02 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.3 (31.0) 1.65 (12.2) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.8 (29.0) 1.11 (25.7) -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.3 (31.0) 1.07 (29.1) -100.9 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.8 (29.0) 1.13 (24.0) -101.0 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.4 (31.3) 1.17 (22.0) -100.9 2 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.9 (29.5) 1.21 (20.6) -101.0 2 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.7) 1.17 (22.0) -100.9 2 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.7 (28.5) 1.23 (19.9) -101.0 2 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.0 (30.1) 1.15 (22.9) -99.2 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.6 (27.5) 1.14 (23.9) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.0 (30.1) 1.09 (27.2) -99.2 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.6 (27.4) 1.15 (23.0) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 12968
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16W844113 20170621
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 60.1 0.01
RRU-3 BXP_2050 RRU4415B3 1 OFF ON OFF N/A KRC161637/1 R1C
B441078914 20180212 74.6 0.02 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.17 (22.0) -100.9 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.20 (20.7) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.17 (22.1) -100.8 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.21 (20.3) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 11 1.2 (30.6) 1.16 (22.8) -99.2 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 B 11 0.7 (28.4) 1.14 (23.9) -99.4 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 C 11 1.2 (30.6) 1.09 (27.1) -99.1 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
RRU-3 BXP_2050 RRU4415B3 D 11 0.7 (28.4) 1.15 (23.0) -99.3 0 SE=3 AG=3
FDD=DKMN17C_LTE (1:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
$ssh_pid = 10756
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
221208-15:37:27 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/5800
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
get /rop/A20221205.2015-2030_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.2015-2030_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 43.7 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 61.7 0.02
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 - - -101.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.12 (24.8) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.3) 1.11 (25.5) -102.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.2 (30.8) 1.13 (24.5) -101.5 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.1 (30.4) 1.17 (22.1) -100.4 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (28.0) 1.20 (21.0) -100.2 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.2 (30.9) 1.17 (22.1) -100.7 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.8 (28.8) 1.21 (20.5) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 19:35:45 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3508)
2022-12-05 19:35:57 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3557)
2022-12-05 19:39:23 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 19:39:24 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 19:39:24 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 19:40:24 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 20:35:31 m Power Loss FieldReplaceableUnit=RRU-
3 (Power Failure Alarm (PFA).)
2022-12-05 20:35:32 M Service Unavailable EUtranCellFDD=DKMN17C_LTE
(UnderlyingResourceUnavailable)
>>> Total: 9 Alarms (1 Critical, 2 Major)
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V325039 20161210
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W962884 20170725 62.1 0.02
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.18 (21.8) -100.8 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.20 (20.8) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.3) 1.17 (22.1) -100.8 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.9 (29.5) 1.22 (20.1) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
$ssh_pid = 5552
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
38 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17A_LTE
90 1 (UNLOCKED) 1 (ENABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17B_LTE
142 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,EUtranCellFDD=DKMN17C_LTE
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V325039 20161210
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 42.6 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.14 (23.9) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (25.4) -101.2 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.22 (20.0) -100.8 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.16 (22.7) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
get /rop/A20221205.2030-2045_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.2030-2045_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V325039 20161210
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 45.9 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.14 (23.5) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (25.4) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.3 (31.0) 1.22 (20.2) -100.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.8 (29.0) 1.30 (17.6) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V325039 20161210
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 47.6 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.15 (23.3) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.11 (25.8) -101.2 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.22 (20.2) -100.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.16 (22.7) -100.9 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
221208-15:51:12 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/5800
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
422 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-1
433 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-2
444 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st cell
DKMN17LTE> st rru
DKMN17LTE> st rru
221208-15:51:41 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/5800
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
422 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
433 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-2
444 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 39.6 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 51.1 0.00
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.54 (13.5) -101.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.19 (21.1) -101.8 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.3) 1.08 (28.3) -101.5 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.2 (30.8) 1.17 (21.9) -101.6 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.4 (31.4) 1.14 (23.8) -100.9 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.9 (29.5) 1.11 (26.0) -98.3 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.1 (30.4) 1.22 (20.1) -100.5 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (28.0) 1.14 (23.5) -100.9 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 3404
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V079796 20161111
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 58.3 0.01
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.14 (23.8) -100.8 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (26.0) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.3 (31.0) 1.21 (20.5) -100.5 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.8 (29.0) 1.19 (21.1) -100.7 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
$ssh_pid = 7980
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
get /rop/A20221205.2045-2100_DKMN17LTE.xml.gz
/home/KhoaSnip/moshell_logfiles/logs_moshell/pmfiles/169.254.2.2/rop/
A20221205.2045-2100_DKMN17LTE.xml.gz ... OK
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V079796 20161111
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 61.1 0.01
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.2 (30.7) 1.14 (23.5) -100.8 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.7 (28.5) 1.10 (26.3) -101.1 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.21 (20.3) -100.5 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.19 (21.3) -100.7 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
...
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16W964036 20170725 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 62.2 0.01
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.7 (32.3) 1.14 (23.6) -100.8 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.2 (30.8) 1.11 (25.8) -101.0 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.22 (20.2) -100.5 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.17 (22.0) -100.6 1 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
221208-16:07:23 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/5800
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
...
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16W964036 20170725 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16W844113 20170621 63.4 0.01
RRU-3 BXP_2050 RRU4415B3 0 ? ? ? N/A KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_01 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 B 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 C 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-1 BXP_2048 RRUS32B3 D 00 - - 0 SE=1 AG=1
FDD=DKMN17A_LTE (0:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 1.0 (30.2) 1.14 (23.5) -100.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.11 (26.0) -101.0 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.0 (30.2) 1.22 (20.2) -100.5 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 0.6 (27.6) 1.19 (21.4) -100.6 0 SE=2 AG=2
FDD=DKMN17B_LTE (1:2:124)
RRU-3 BXP_2050 RRU4415B3 A 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 B 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 C 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 BXP_2050 RRU4415B3 D 00 - - 0 SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> q
Bye...
#####################################################################
# Welcome to MoShell 19.0n (LPA108514/1_R19N) #
# Finn Magnusson, Jan Pettersson #
# http://newtran01.au.ao.ericsson.se/moshell #
# Contact: [email protected] #
# [email protected] #
#####################################################################
WARNING: the moshell version currently running is more than 157 weeks old.
It is recommended to always use the latest released moshell version.
Please download the latest version from http://newtran01.au.ao.ericsson.se/moshell
Checking ip contact...OK
HELP MENU : h
BASIC MO COMMANDS : m
OTHER MO COMMANDS : n
OTHER COMMANDS : o
PM COMMANDS : p
QUIT : q
169.254.2.2> lt all
$ssh_pid = 9812
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
DKMN17LTE> st rru
DKMN17LTE> st rru
221208-16:15:28 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/11156
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
422 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-1
433 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-2
444 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> st rru
DKMN17LTE> st rru
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
221208-16:17:15 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/11156
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
352 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3001E
353 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,TermPointToMme=MMEMKXC3002E
354 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ0902E
355 1 (UNLOCKED) 0 (DISABLED) ENodeBFunction=1,TermPointToMme=MMEMKXQ901E
===================================================================================
Total: 4 MOs
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st mme
DKMN17LTE> st rru
DKMN17LTE> st cell
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
......................................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 46.5 0.00
RRU-2 BXP_2049 RRUS32B3 1 ON ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 41.6 0.00
RRU-3 Z??_01 RRU4415B3 0 ? ? ? ? KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.2 (30.7) 1.16 (22.6) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.7 (28.5) 1.11 (25.9) -101.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.7 (32.3) 1.20 (20.9) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 1.2 (30.8) 1.59 (12.8) -101.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 - - -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 1.0 (30.2) 1.12 (24.9) -101.6 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.4 (31.4) 1.11 (25.9) -103.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 - - -101.5 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-3 Z??_01 RRU4415B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 C 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 D 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 48.0 0.00
RRU-2 BXP_2049 RRUS32B3 1 ON ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 42.8 0.00
RRU-3 Z??_01 RRU4415B3 0 ? ? ? ? KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.0 (30.2) 1.16 (22.7) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.6 (27.6) 1.10 (26.2) -101.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.3 (31.0) 1.19 (21.1) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.8 (29.0) 1.44 (14.8) -101.7 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (D:2:124)
RRU-3 Z??_01 RRU4415B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 C 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 D 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> cabx
221208-16:22:03 169.254.2.2 19.0n MSRBS_NODE_MODEL_18.Q4_369.27924.51_aace
stopfile=/tmp/11156
$ssh_pid = 13284
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
..
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 50.6 0.00
RRU-2 BXP_2049 RRUS32B3 0 ? ? ? N/A KRC161413/1 R1D
D16V325039 20161210
RRU-3 Z??_01 RRU4415B3 0 ? ? ? ? KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.6 (32.0) 1.16 (22.7) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 1.1 (30.5) 1.10 (26.5) -101.8 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.20 (20.9) -101.5 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.7 (28.5) 1.15 (23.1) -101.6 1 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 B 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 C 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 D 00 - - 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU4415B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 C 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 D 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> st rru
$ssh_pid = 10120
Connected to 169.254.2.2
(SubNetwork=ONRM_ROOT_MO,SubNetwork=LTE,MeContext=DKMN17LTE,ManagedElement=DKMN17LT
E)
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
422 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
433 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-2
444 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=RRU-3
===================================================================================
Total: 3 MOs
DKMN17LTE> cabx
INFO: cabx is not applicable on RCS nodes. Using invxrf instead. Type "h inv" for
more details on available options.
...................................................................................
.........................................
.......
Collecting TN data...
...................................................................................
.....................................
Collecting RF data...
.....
Node: RadioNode L CXP9024418/6_R55D31 (18.Q4.1)
===================================================================================
==================================================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL
DATE TEMP UPT
===================================================================================
==================================================
1 000100 DUS5201 1 OFF ON OFF ON KDU137925/31 R3C/B
CD3L676130 20160819 (Bb5216)
RRU-1 BXP_2048 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V079796 20161111 55.7 0.00
RRU-2 BXP_2049 RRUS32B3 1 OFF ON OFF N/A KRC161413/1 R1D
D16V325039 20161210 42.2 0.00
RRU-3 Z??_01 RRU4415B3 0 ? ? ? ? KRC161637/1 R1C
B441078914 20180212 (Radio4415B3)
SUP Z??_02 0 ? ? ? ?
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
===================================================================================
==================================================
999 Cabinet=1
FANGROUP ?
Cabinet=1,FanGroup=1
FANGROUP ?
Cabinet=1,FanGroup=2
FANGROUP ?
Cabinet=1,FanGroup=3
0 ? ? SupportUnit=1
(FAN)
0 ? ? SupportUnit=2
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
0 ? ? SupportUnit=3
(FAN)
0 ? ? SupportUnit=4
(POWER_SUPPLY EXTERNAL_ALARM_PORTS)
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
BOARD LNH PORT T S OpMode AutoNeg MacAddress VlanIds LOS BER
===================================================================================
==================================================
DUS5201 000100 TN_A E 1 100M_FULL true 90:38:09:33:F0:DB 125,225
-----------------------------------------------------------------------------------
--------------------------------------------------
===================================================================================
==================================================
FRU LNH BOARD RF BP TX (W/dBm) VSWR (RL) RX (dBm) UEs
Sector/AntennaGroup/Cells (State:CellIds:PCIs)
===================================================================================
==================================================
RRU-1 BXP_2048 RRUS32B3 A 11 1.2 (30.7) 1.15 (23.0) -101.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 B 11 0.7 (28.5) 1.10 (26.6) -100.2 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 C 11 1.2 (30.7) 1.20 (20.8) -100.1 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-1 BXP_2048 RRUS32B3 D 11 0.7 (28.5) 1.17 (22.0) -101.4 0 SE=1 AG=1
FDD=DKMN17A_LTE (1:1:123)
RRU-2 BXP_2049 RRUS32B3 A 11 - - -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 B 11 0.6 (27.6) 1.12 (24.8) -101.4 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 C 11 1.6 (32.0) 1.24 (19.3) -100.8 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-2 BXP_2049 RRUS32B3 D 11 1.1 (30.5) 1.11 (25.5) -101.3 0 SE=2 AG=2
FDD=DKMN17B_LTE (0:2:124)
RRU-3 Z??_01 RRU4415B3 A 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 B 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 C 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
RRU-3 Z??_01 RRU4415B3 D 00 - - - SE=3 AG=3
FDD=DKMN17C_LTE (0:3:125)
-----------------------------------------------------------------------------------
--------------------------------------------------
Tip: use option "a" or "af" to show the connected AntennaSubunits and
AntennaNearUnits.
DKMN17LTE> alt
Collecting Alarms...
..
===================================================================================
=================================
Date & Time (UTC) S Specific Problem MO (Cause/AdditionalInfo)
===================================================================================
=================================
2022-12-05 21:15:48 C License Key File Fault Lm=1 (Key file fault in
Managed Element AI: eventId:3739)
2022-12-05 21:16:02 m SFP Not Present
FieldReplaceableUnit=1,SfpModule=C (No SFP or electrical cable plugged in.)
2022-12-05 21:16:09 w Software Management Lost Connection to File Server
SwM=1,UpgradePackage=CXP9024418/6-R55D31 (Uri missing AI: eventId:3782)
2022-12-05 21:19:35 m No Connection SupportUnit=1 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 21:19:35 m No Connection SupportUnit=2 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-1
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-2. Port Host: 1 1. Port SU: 1
1.)
2022-12-05 21:19:35 m No Connection SupportUnit=3 (Affected
services: FAN. Host: ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port
Host: 1. Port SU: 1.)
2022-12-05 21:19:35 m No Connection SupportUnit=4 (Affected
services: POWER_SUPPLY EXTERNAL_ALARM_PORTS. Host:
ManagedElement=1,Equipment=1,FieldReplaceableUnit=RRU-3. Port Host: 1. Port SU: 1.)
2022-12-05 21:20:35 M No Connection FieldReplaceableUnit=SUP
(No hardware detected for the configured FieldReplaceableUnit)
2022-12-05 21:21:27 M Resource Activation Timeout EUtranCellFDD=DKMN17C_LTE
(Resource Activation Timeout)
>>> Total: 9 Alarms (1 Critical, 2 Major)
DKMN17LTE>