Sanitation, Plumbing Design and Installation
Sanitation, Plumbing Design and Installation
Sanitation, Plumbing Design and Installation
SANITATION, PLUMBING DESIGN & INSTALLATION 6. What is the equivalent when you
use 90° fittings?
1. Plugging an opening with oakum,
lead or other materials that are A. 1/8
pounded into the annular space. B. 1/4
C. 1/8
Also, the material pounded into
D. 1/9
the annular opening?
Answer: B
A. Caulking
B. Cap 7. Which is not a fixture?
C. Catch Basin
D. Chase A. Urinal
B. water closet
C. Lavatory
Answer: A D. Water heater
2. The flow of water or other Answer: D
liquids, mixtures or substances
into the distributing pipes of a 8. Expansion joints that are
portable supply of water from any acceptable except______
source other than from its
intended source? A. Cold water
B. Hot water
C. Vent
A. Backflow D. Steam
B. Back-siphonage
C. Backpressure Answer: C
D. Ball cock
9. What determines the sizing of
Answer: A horizontal and vertical drainage
pipes?
3. Any pipe or fitting installed in
a vertical position or which A. No. of bathrooms installed
B. Total fixture units
forms an angle of not more than
C. Type of building
forty-five (45) degrees with the D. Location of fixtures
vertical line.
Answer: B
A. Vertical pipe
B. Diagonal pipe 10. What is water not suitable for
C. Horizontal pipe drinking but suitable for
irrigation, flushing toilets,
D. None of the above
urinals, etc.?
Answer: A A. Bottled water
B. from creeks
4. Wedge Shaped plug Valve C. from rivers
D. Non potable water
A. Door Valve
B. Entry Valve Answer: D
C. Gate Valve
D. Angle Valve 11. Which fitting is equivalent to 90
deg.
Answer: C
A. 1/16
B. 1/8
5. What are the valves that is used C. 3/8
to prevent backflow of water? D. 1/4
Answer: B
A. Upfeed pipe
B. Hydrant
C. Standpipe
D. None of the above
Answer: C
Answer: C
A. 5”
B. 6”
C. 4”
D. 3”
Answer: B
A. water usage meter
B. water meter
C. metering device
D. Meter stop
Answer: A
A. Pendent
B. Upright
C. Recessed
D. Semi-recessed
Answer: A
A. Annulus A. 300 mm
B. Void B. 457 mm
C. Air space C. 600 mm
D. Freeboard D. 914 mm
Answer: A Answer: D
25. Which of the following fixtures 29. What is the depth of “C”
may not be indirectly connected
to a drainage system?
A. Commercial dishwasher
B. Sterilizer
C. Drinking fountain
D. Water softener backwash
Answer: C
A. 304 mm
B. 457 mm
C. 600 mm
D. 914 mm
Answer: C
A. Earth fill
B. Fill material
C. Filter material
D. Cover
Answer: A
A. 300 mm
B. 457 mm
C. 600 mm
D. 914 mm
A. 150 mm
B. 200 mm
C. 300 mm
D. 500 mm
Answer: C
A. OSHA
B. Everyone
C. Owner’s agent
D. Safety Department
Answer: B
Answer: D
A. 24 hours
B. 12 hours
C. 48 hours
D. 72 hours
Answer: A
Answer: A
A. P-trap
B.
C.
D.
Answer: A
A. 10 ft
B. 5 ft
C. 3 ft
D. 4 ft
Answer: A
A. Main Vent or Vent Stack
B. Circuit Vent
C. Branch Vent
D. Soil Branch
Answer: C
41. Identify no. 4 in figure below
5|Page Engr. Andro S. Rebuyas, CE, ME-1, MP, M.ASCE
PAST BOARD EXAM FOR MASTER PLUMBER (FEBRUARY 9-10, 2020)
A. Ratio of 1:45
B. Ratio of 1:25
C. Ratio of 1:55
D. Ratio of 1:30
Answer: D
A. Mass Concrete
B. Reinforced Concrete
C. Earth Base
D. Light Weight Concrete
Answer: B
A. Hand Auger
B. Closer Auger
C. Straight Auger
D. Darsho’s Auger
Answer: B
A. Wash Down
B. Reverse Trap
C. Siphon Jet
D. Siphon Vortex
Answer: A
A. 120 days
B. 1 year
C. 2 years
D. 360 days
Answer: B
A. Ferrule
B. Plug
C. Oakum
D. Union
Answer: D