Elmag 200

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

TM

®
ELMAG 200
MAINS / 24V DC POWERED ELECTROMAGNETIC FLOW METER
Features

Universal Power Supply 90 to 250V AC / 24V DC /


Solar Powered
Suitable for conductive liquids
Full bore type
Empty pipe indication
Material of construction in accordance to process parameters
Local Indication through LCD Display
Inbuilt Relay Status output (High / Low / Batch)
HART Compatible
Optional pressure measurement along with flow

Description

Electronet series ELMAG®-200 are micro-controller based full bore type electromagnetic flow meters specially used for various
industrial applications. These flow meters accurately measure the flow rate of conductive liquids and slurries in closed pipes. Due to
its simple and rigid design, the flow meter is an obstruction less and maintenance-free instrument in place of conventional
mechanical flow measuring devices. The use of ‘Pulsed DC’ technology offers highest ability and better measuring accuracy in the
form of electrical signal 4-20 mA DC linearly proportional to volumetric flow. The instrument is based on Faraday’s law of
electromagnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic
field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to
measuring flow range.

Technical Specifications
Media Liquid (Conductive)
Conductivity > 5 µS/cm
Viscosity 200 cp max
Line Size 15 NB to 3000 NB
Excitation Pulsed DC
Output : 1 1) 4 to 20mA DC
(Any one) 2) 4 to 20mA DC with HART (Compatible)
Type of Output Output : 2
Pulse (Open Collector Type)
(Any one)
Output : 1
RS 485 supporting MODBUS RTU Protocol
(Any one)
Communication Output
Output : 2 1) GSM 2) GPRS 3) Ethernet MODBUS TCP
(Any one)
Display LCD Display - 6 Digit for Flow Rate & 8 Digit for Totalizer Flow
3
Engineering Unit User Programmable (m /hr by default)
Calibration Range Wet Calibrated at IEC/ISO/EN17025 Accredited Calibration Laboratory.
Accuracy < ± 0.5% of M.V. +(± 5mm /sec) for Velocity Range 0.3 m/s to 6 or 12 m/s

www.eeplindia.com EEPL-S011E-110620 1
MAINS / 24V DC POWERED ELECTROMAGNETIC FLOW METER ELMAG® - 200

Linearity +/- 0.5% of M.V.


Repeatability +/- 0.2% of M.V.
Temperature Coefficient +/- 0.05% per °C
Process Temperature -20 to 85°C max for Rubber Lining & -20 to 220°C for PTFE Lining
2
Process Pressure 16 kg/cm max (Higher on request)
1) Lining - Neoprene / Ebonite Rubber, PFA, PTFE, PU, CERAMIC
2) Flange - MS, CS, SS316, SS304
Material of construction
3) Electrode - S S316L, Hastelloy C, Platinum, Tantalum, Titanium
4) Coil Housing - MS, SS304, SS316
Option 1 : 90 - 250 V AC, 50 Hz
Power Supply Option 2 : 24 V DC (+/- 10%)
Option 3 : Solar Powered 24V DC
Power Consumption < 10 VA
Isolation 1.4 KV between Input, Output & Power Supply
Response Time Less than 1 Sec.
Electronics Integral (Local) / Remote
Electronic Protection Class Field Mount Weather Proof IP-67, Field Mount Weather Proof IP-68,
DIN Standard (IP 54), Flameproof (CMRI IIA IIB Certified)
Sensor / Flow Tube Protection class Weather Proof IP-67, IP-68
Process Connections ANSI150 flanged, as per table B 16.5 (Other On Requirement)
Mounting In-Line Horizontal / Vertical
Ambient Conditions Temperature -20 to 75°C / Humidity 5 to 95% non condensing

Certification

Assembly Overview

132mm 205mm
ø 115 mm

0000.00 m3/Hr
000000.02 m3 L

ELECTRONET

ø DBC

øR

D
FD

Fig. 1 Front View Fig. 2 Side View

www.eeplindia.com EEPL-S011E-110620 2
MAINS / 24V DC POWERED ELECTROMAGNETIC FLOW METER ELMAG® - 200

TABLE : Dimensional Details (Flow Meter with ANSI 150 Flange)


Refer Drg. Fig.1 & 2
Line Size Flange Diameter Diameter Diameter No. Thickness Flange to 3
Flow Range (m /hr)
of Housing
Diameter of Raised of Bolt of of OD Flange for Velocity 0.3m/s to 6m/s
D (mm) Face Hole Circle Bolt Hole Holes Flange (mm) Distance
Inch NB R (mm) DBC (mm) (mm) (FD) (mm)
Min. Max.
½” 15 88.9 34.9 60.3 15.9 4 11.1 125 200 0.19 3.817
¾” 20 98.4 42.9 69.8 15.9 4 12.7 125 200 0.33 6.785
1” 25 107.9 50.8 79.4 15.9 4 14.3 145 200 0.53 10.602
1¼” 32 117.5 63.5 88.9 15.9 4 15.9 155 200 0.86 17.371
1½” 40 127.0 73.0 98.4 15.9 4 17.5 155 200 1.35 27.143
2” 50 152.4 92.1 120.6 19.0 4 19.0 165 200 2.12 42.4115
2½” 65 177.8 104.8 139.7 19.0 4 22.2 185 200 3.58 71.675
3” 80 190.5 127.0 152.4 19.0 4 23.8 205 200 5.42 108.573
4” 100 228.5 157.2 190.5 19.0 8 23.8 245 260 8.48 169.646
5” 125 254.0 185.7 215.9 22.2 8 23.8 265 260 13.25 265.071
6” 150 279.4 215.9 241.3 22.2 8 25.4 285 310 19.085 381.703
8” 200 342.9 269.9 298.4 22.2 8 28.6 355 360 33.929 678.584
10” 250 406.4 323.8 361.9 25.4 12 30.2 405 460 53.014 1060.28
12” 300 482.6 381.0 431.8 25.4 12 31.8 485 510 76.340 1526.81
14” 350 533.4 412.7 476.7. 28.6 12 34.9 555 562 103.908 2078.16
16” 400 596.9 469.9 539.7 28.6 16 36.5 605 612 135.716 2714.33
18” 450 635.0 533.4 577.8 31.7 16 39.7 605 612 171.766 3435.33
20” 500 698.5 584.2 635.0 31.7 20 42.9 630 612 212.057 4241.15
24” 600 812.8 692.1 749.3 34.9 20 47.6 755 612 305.362 6107.25
Note : Flange to flange distance (FD) Tolerance : 1) 1/2"(15NB) to 6"(150NB) : +/-3mm 2) 8"(200NB) to 24"(600NB) : +/-5mm
All dimensions are in ‘mm’ Wet Calibrated at IEC/ISO/EN17025 Accredited Calibration Laboratory.
For dimensions of line size above 600NB, please consult factory. Flow meter should be selected with the help of Nomograph (recommended full scale velocity).
Typical mounting dimensions are for reference only. Flow indication of 6 digit max. up to 999999.

Flow Nomograph

2.0%
1.8%

1.6%
Measuring error (% M.V)

1.4%

1.2%

1.0%

0.8%

0.6%

0.4%

0.2%

0.0%
0 1 2 3 4 5 6 m/s
Flow Velocity

Applications

Food Industry Chemical Industry Atomic Energy Manufacturing Industry


Automation Industry Thermal Power Energy Process Industry Water Treatment Industry

www.eeplindia.com EEPL-S011E-110620 3
MAINS / 24V DC POWERED ELECTROMAGNETIC FLOW METER ELMAG® - 200

Product Ordering Information :


Order Code for Flow Transmitter

Sample Order Code : TX 1 A2 B2 C1 D2 EX F2 GX HI I2

Parameter Code Description Parameter Code Description


Electronics TX 1 Field Mount Weather Proof IP67 F1 1 Relay Output
TX Alarm or Relay
Transmitter TX 4 Flameproof (CMRI IIA IIB Certified) F Output F2 2 Relay Outputs
FX NA
A1 90 to 250 VAC (maximum two alarms or two Relays )
A Power Supply A2 24V DC
Communication G1 RS485 (MODBUS RTU)
A4 Solar Powered 24V DC G Output 1 (Any One)
GX NA
MOC Electronics B1 Aluminium Die Cast
B Enclosure H1 GSM
B2 SS316 Communication
H2 GPRS
H Output 2
C1 M20 *1.5 F (Any One) H4 Ethernet MODBUS TCP
Electrical C2 1/2 Inch NPT F HX NA
C
Connection C3 M12 Connector
I1 10 Kg
CY Other Process Pressure
I Calibration Range I2 20 Kg
D1 4 to 20 mA IX NA
Output 1
D (Any One) D2 4 to 20 mA HART (Compatible)
DX NA

Output 2 E1 Pulse (Open Collector Type) Note :


E In case of flameproof version only electronics enclosure is flameproof certified.
(Any One) EX NA Accuracy defined at Lab Conditions.
Relay & Alarms are programable. Relay 1 is programmable for High / Low / Batch.

www.eeplindia.com EEPL-S011E-110620 4
MAINS / 24V DC POWERED ELECTROMAGNETIC FLOW METER ELMAG® - 200

Order Code for Flow Tube

Sample Order Code : FT 15 J2 K2 L1 M2 N1 O3 P1 Q1 R2 S1 U1

Parameter Code Description Code Description Parameter Code Description


FT 15 15 NB FT 600 600 NB Material of O1 MS
FT 20 20 NB FT 700 700 NB O construction - O2 SS 304
FT 25 25 NB FT 800 800 NB Coil Housing O3 SS 316
FT 32 32 NB FT 900 900 NB P1 Neoprene Rubber (Above 40 NB)
FT 40 40 NB FT 1000 1000 NB P2 Ebonite Rubber (Above 40 NB)
FT 50 50 NB FT 1100 1100 NB Flow Tube P3 PFA (15 to 300 NB)
FT 65 65 NB FT 1200 1200 NB P Lining P4 PTFE (15 to 600 NB)
FT 80 80 NB FT 1400 1400 NB Material P5 PU (15 to 400 NB)
FT 100 100 NB FT 1500 1500 NB P6 Ceramic (15 to 600 NB)
FT Flow Tube
FT 125 125 NB FT 1600 1600 NB PY Other
FT 150 150 NB FT 1800 1800 NB Q1 ANSI 150 B16.5
FT 200 200 NB FT 2000 2000 NB Q2 ANSI 300 B16.5
FT 250 250 NB FT 2200 2200 NB Q3 ANSI 600 B 16.5
FT 300 300 NB FT 2400 2400 NB Q4 DIN PN 10 EN 1092-1
FT 350 350 NB FT 2600 2600 NB Q5 DIN PN 16 EN 1092-1
FT 400 400 NB FT 2800 2800 NB Flange Q6 DIN PN 25 EN 1092-1
Q Standard
FT 450 450 NB FT 3000 3000 NB and Rating Q8 IS 1538
FT 500 500 NB Q9 AWWA Table D
Electronics J1 Integral (Local) Q10 AWWA Table F
J
Location J2 Remote QY Other
K1 5 Meter QX NA
K2 10 Meter Material of R1 SS 304
Remote Cable
K K3 15 Meter R construction - R2 SS 316
Length Flow Tube
K4 25 Meter RY Other
KX NA S1 SS 316L
Flow Tube L1 IP-67 (In case of Integral) Material of S2 Hastelloy C
L
Protection Class L2 IP-68 (In case of Remote) S construction - S3 Platinum
M1 Threaded (15 to 50 NB) Electrode S4 Tantalum
M2 Flanged (15 To 3000 NB) S5 Titanium
Process M3 Triclover (15 to 100 NB) U1 10 Kg
M Connection Inline Pressure
M4 SMS Union (25 to 100 NB) U U2 20 Kg
Sensor
Compact (Wafer) - UX NA
M5
15 to 200 NB Maximum
N1 MS
Material of N2 CS Note :
construction - Due to our continuous product revisions, design specification and
N N3 SS 304
model numbers are subject to change without notice.
Flange N4 SS 316 To be used for industrial applications.
NX NA For other requirement please consult factory.

ELECTRONET EQUIPMENTS PVT. LTD.


Factory Address: Registered Office:
Plot No. 8, (SEZ) Phase 1, Kesurdi MIDC, Plot No. 84, 85, 86, Tiny Industrial Estate,
Khandala, Dist.- Satara Kondhwa Budruk,
Pin: 412 801, Maharashtra, India. Pune-411 048, Maharashtra, India.

+91-20-26931476/2039 [email protected] +91-20-26934122 www.eeplindia.com

EEPL-S011E-110620 5
*Not applicable for trade custody transfer applications.

You might also like