0% found this document useful (0 votes)
382 views26 pages

Havells Enviro Gti: Web Monitoring Manual

This document provides information about Havells Enviro GTi string inverters and their Wi-Fi configuration. It introduces a new range of residential solar inverters from 1.1 kW to 70 kW for single and three phase applications. The inverters come with 7 years warranty and standard Wi-Fi communication. The document describes the process to connect the inverter to a Wi-Fi network using its onboard module for monitoring through a web browser.

Uploaded by

nitin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
382 views26 pages

Havells Enviro Gti: Web Monitoring Manual

This document provides information about Havells Enviro GTi string inverters and their Wi-Fi configuration. It introduces a new range of residential solar inverters from 1.1 kW to 70 kW for single and three phase applications. The inverters come with 7 years warranty and standard Wi-Fi communication. The document describes the process to connect the inverter to a Wi-Fi network using its onboard module for monitoring through a web browser.

Uploaded by

nitin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

Havells Enviro GTi

Web Monitoring Manual

CLASSIFICATION | PUBLIC
Website

• For Customer – Wi-Fi


“pvcheck.havells.com”

CLASSIFICATION | PUBLIC
GRID TIE STRING INVERTERS (GTI)

• Introducing a new range of Residential Havells Inverter


• State of the art string base inverter
• Single Phase Residential Inverters - 1.1 kW to 5kW /
Single and Dual MPPT
• Three Phase Residential & Small Commercial Inverters
– 5.5 kW to 11kW
• Three Phase Commercial Inverters – 15 kW to 70 kW
• 7 years standard warranty
• Equipped with standard WIFI communication
• Inverters are equipped with 25 year data storage
capability
• Real time MPPT for maximum generation
• Wide input voltage range

CLASSIFICATION | PUBLIC
Enviro GTi Product Range

Sr. No. Model Description Application


Single Phase Inverter, Single
1. Enviro GTi 1kW – 3 kW Single Phase for Residential Building
MPPT, Wi-Fi Standard
Single Phase Inverter,
Dual MPPT,
2. Enviro GTi 3 kW – 6 kW
G-2 Model ,
Three phase for industrial/commercial
Wi-Fi Standard
building
3. Enviro GTi 4 kW – 12 kW
4. Enviro GTi 15 kW Three Phase Inverter,
Dual MPPT,
5. Enviro GTi 20 kW – 33 kW
DC Switch Standard,
Three phase for commercial projects
Wi-Fi Standard
6. Enviro GTi 50 kW – 70 kW

CLASSIFICATION | PUBLIC
Enviro GTi Product Range

Enviro GTi 1100 , 2200, 3000 Enviro GTi 4000D , 5000D, Enviro GTi 5500TX , 6600TX, 8800TX,
Single Phase 6000D 11000TX
Single Phase Three Phase

CLASSIFICATION | PUBLIC
Enviro GTi Product Range

Enviro GTi 15000T Enviro GTi 20000TD, 25000TD, Enviro GTi 50KT, 60KT, 70KT
Three Phase 30000TD, 33000TD Three Phase
Three Phase

CLASSIFICATION | PUBLIC
Enviro GTi Product Range

Model/ MPPT Build-in Build-in


Sr. No. String No. DC Switch Communication
Configure N0. DC SPD AC SPD

Enviro GTi 1kW – 3 kW


1 1 Optional None None
1. Single Phase On board WIFI,485
Enviro GTi 3 kW – 6 kW
2 2 Optional None None
2. Single Phase External WIFI,485
Enviro GTi 4 kW – 12 kW External
2 2 Standard None None
3. Three Phase WIFI/GPRS,485
Enviro GTi 15 kW External
2 4 Standard Optional Optional
4. Three Phase WIFI/GPRS,485
Enviro GTi 20 kW – 33 kW External
2 6 (20kW-4) Standard None None
5. Three Phase WIFI/GPRS,485
Enviro GTi 50 kW – 70 kW 12(50kW- Standar External
3 Standard Optional
6. Three Phase 10) d WIFI/GPRS,485

CLASSIFICATION | PUBLIC
Wi-Fi Configuration
• Prepare a Laptop or device, e. g tablet or
smart Phone that enables Wi-Fi
• Obtain an IP address automatically
• Procedure
Step 1 : click on Wi-Fi
Step 2 : connect with your personal internet
access point or WLAN
Step 3 : Right click on your connected AP click
in status > properties to open the wireless
network property setup window

CLASSIFICATION | PUBLIC
Wi-Fi Configuration
Step 4 : Double click on internet Protocol Version 4 (TCP/IPv4). Click on General > obtain an IP address
automatically > OK to finish the Setup.

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 1 : Click on Wi-Fi

Step 2 : Connect with Havells


Inverter Wi-Fi Module,
defaulted with no password
and its name started as AP_
and a following 9- digit Wi-Fi
serial number. See Figure

AP_502173653

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 3 : when connected open browser (IE is recommended) , head to http://10/10/100.254/ , and fill in
user name and password which all defaulted as admin for the first time.

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 4 : when successfully logged in, user can find the basic information on their inverter Wi-Fi Module

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 5 : Please Click in Wizard > Start to Start the detailed setup on your inverter Wi-Fi module
Step 6 : Select Wireless connection and click Next

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 7 : Select your personal wireless network. This can be done by refreshing your wireless network or
add it manually.
Step 8 : Please enter your personal wireless network password. Then click next.

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 9 : Select Enable > Next to obtain IP address automatically
Step 10 : Click next.

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 11 : Click OK to wait for setting complete.

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 12 : Setup of wireless network connection priority and connection mode.
Open control panel > network and sharing center> manage wireless networks, set your home routers access point as default to
connect with your personal computer automatically. Make sure it has the highest priority. To the device Wi-Fi module, set its AP as
default to connect with your personal computer manually.
Step 13. :Connect with your personal wireless network or WLAN.

CLASSIFICATION | PUBLIC
Enviro GTi Wi-Fi Setup
Configuration
Procedure
Step 12 : Setup of wireless network connection priority and connection mode.
Open control panel > network and sharing center> manage wireless networks, set your home routers access point as default to
connect with your personal computer automatically. Make sure it has the highest priority. To the device Wi-Fi module, set its AP as
default to connect with your personal computer manually.
Step 13. :Connect with your personal wireless network or WLAN.

CLASSIFICATION | PUBLIC
Create Account on portal

• Please kindly enter into


http://pvcheck.havells.com/login.
html website.
• Click on Register now if you do
not have an account.
• Fill in basic registration
information upon request.
• Fill in details to complete the
registration.
• If Registration is successful, then
below page will be display. Click
OK to return to homepage of the
portal.

CLASSIFICATION | PUBLIC
How to Build a new plant
Step 1 : After Login, Create the Plant by clicking the below screen.

CLASSIFICATION | PUBLIC
How to Build a new plant
Step 2 : Fill Plant Name , Project type, ON Gird Type & Location.

CLASSIFICATION | PUBLIC
How to Build a new plant
Step 3: click Satellite and switch to map mode, convenient to describe roof shape.

CLASSIFICATION | PUBLIC
How to Build a new plant
Step 4 : fill rest details and click on next.

CLASSIFICATION | PUBLIC
How to Build a new plant
Step 5:

Click “Complete "and system


will lead you a question that
“ do you want to add a new
device now ?”, if you know
the data logger’s SN, we
recommend you click “yes”
and system will lead you to
“Add a New Device” and type
the data logger SN numbers
one by one.

CLASSIFICATION | PUBLIC
Adding Inverter to plant
Step 1:

Click “device “ at top and


click on inverter to put the
inverter Serial number.

Step 2

Fill the full information of


basic parameters. If window
ask for information. & Save.

CLASSIFICATION | PUBLIC
Saving & Uploading data

• After finishing adding, plant will


be “under construction”.

• The system is waiting for data


logger to upload data. Please
ensure data logger is powered on
and normal connection between
inverter and data logger.

• Data logger will take time to


upload the data to server , data
will update after 10 minutes.

CLASSIFICATION | PUBLIC