Disturbance Fault Recorder: Functions

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

www.nrec.

com/en

PCS-986
Disturbance Fault Recorder

The PCS-986 disturbance & fault recorders are designed to • Initiating recording based on DC sudden change or DC
record electrical parameters of generator-transformer units and component out-of-limit
operation processes in the protection& control devices of power
• Initiating recording based on frequency out-of-limit and
plants. The device adopts unit architecture so that hardware and
sudden changes
VRIWZDUHFDQEHÀH[LEO\DVVHPEOHGDQGXSJUDGHGLQWKHIXWXUH
• Initiating recording based on third harmonic out-of-limit

Functions • Initiating recording based on over-excitation out-of-limit


Recording Functions
• Initiating recording based on reverse power out-of-limit
• Initiating recording based on AC voltage
- Phase voltage sudden change • Initiating recording based on low-frequency overcurrent or
zero-sequence voltage for startup/shutdown
- Positive-sequence voltage sudden change
- Zero-sequence voltage sudden change • Initiating recording based on differential current of the main
transformer, step-down transformer, generator or excitation
• Initiating recording based on AC current transformer
- Phases current sudden change
• Initiating recording based on binary input
- Positive-sequence current sudden change
Disturbance Fault
Recording
- Zero-sequence current sudden change • Initiating recording based on system oscillation

• Initiating recording based on AC voltage out-of-limit • Initiating recording manually

• Initiating recording based on AC current out-of-limit • Initiating recording remotely

• Initiating recording based on positive-sequence and negative- • Continuous recording (24hours of uninterrupted recording)
sequence component out-of-limit

155
Protection Automation Control

Auxiliary Function
Features
• Self diagnostic test
• The robust hardware platform adopted for DFR is the same
• Loss of DC power supply alarm as NR Electric’s protection and control system, which has
• Hardware circuit online detection EHHQZHOOSURYHQLQ¿HOG

• Support IRIG-B time synchronization • This device adopts a fully-closed chassis with a well
designed structure, providing separate spaces for low and
Communications high voltage systems. The traditionally integrated circuit
board mode is abandoned. Furthermore, anti-interference
• 1 RJ45 Ethernet port which complies with IEC60870-5-103
measures are integrated into the software, thus enhancing
andIEC61850 protocol
anti-interference capabilities.
• 1 RS-485 serial port used for GPS time synchronization
• This device makes use of an advanced hardware platform,
• 56VHULDOSRUWXVHGWRWHVWDQGFRQ¿JXUHGHYLFH which includes 16 bits parallel A/D converter, 320*240
• 1 Ethernet interface used for FTP service of continuous graphic dot matrix LCD, and real-time multi-task operating
recording and real-time waveform display system. The advanced hardware platform can achieve the
high-capacity, high-precision, high-speed, and real-time
data processing. The high-precision parallel A/D converter
can sample all the AC signals simultaneously in order to
ensure the accuracy of these measurements.