Cleanseal

Terminal housing with HEPA filter

Cleanseal
Is a reliable and versatile filter housing especially
developed for hospitals, clean rooms and Life
Science facilities. This terminal housing equipped
with Camfil´s premium HEPA filters makes an ideal
solution to achieve the high demands on air clean-
liness by minimizing the number of particles and
microorganisms in the air.

Cleanseal is available in several standard sizes and


four different types of connections/configurations.

The filter clamping system is adjustable for different


filter depths. This scalability allows an upgrade of
existing filter to a deeper filter with lower pressure
drop. Low pressure drop filters can be used either
to maintain pressure cascades or to get energy
savings.

Easy to handle and maintain since the housing is


equipped with a tooless filter clamping and a unique
• AIRTIGHT, FULLY WELDED TERMINAL
filter retainer (see details). The filter is pre-positioned
HOUSING
in the housing, no need for a third hand or a second
person.
• ADJUSTABLE CLAMPING SYSTEM FOR
DIFFERENT FILTER DEPTHS
An innovative quick grid fastener and hinged diffusor
plates gives direct access to the filter and control
• UNIQUE FILTER RETAINER FOR EASY ports. Opens with just a badge/card.
INSTALLATION OF FILTER

• SIMPLE AND SECURE GRID LOCK IN


COMBINATION WITH HINGED DIFFUSERS
GIVES QUICK ACCESS TO FILTER AND
CONTROL PORTS

• FLEXIBILITY IN SELECTION OF
STANDARDIZED

• CONTROL PORT FOR MEASURING


UPSTREAM AEROSOL CONCENTRATION
AND DIFFERENTIAL PRESSURE

• COMPLETE INTERCHANGEABLE
DIFFUSION PLATES RANGE

www.camfil.com Camfil AB | CleanSeal | 7 Dec 2017/ 1


Cleanseal
Filter housing with HEPA filter

PRODUCT CODES

Product code - Housing (example: CL-SW-3P3-P-MX-S-C-ø160-N-00-AAAO)


Type CL –a –b –c –d –e –f –g –h –i AAAO
Cleanseal CL
Construction (a)
SW=Steel white (RAL9010)
S4=SS304L
S6=SS316L
Size (b)
3P3, 3P6, 4P4, 5P5, 6P6, 9P6, 9P9, 11P5,12P6
Sealing (C)
P=PU gasket TOP ENTRY (T)
RECTANGULAR
D= DIN gasket SIDE ENTRY (R)
G= GEL gasket
Filter frame height (d)
MD, MX , MG
Connection (e)
S=Side connection
T=Topp cnnection
Connection type (f)
C=Circular
R=Rectangular
Air inlet size (g) SIDE ENTRY
SIDE ENTRY (S)
See dimensioning drawing + table WITH DAMPER (SD)

Damper (h)
N=No Damper
D=Damper (only for circular side connection)
Entry position (i)
00=All square housings
LS=Long side
SS=Short side

Nozzle
(NZ)

Product code - Diffusers (example: PF - 3P3)

–a –b
Four Way Perforated
(4W) (PF)

Swirl (SW) Adjustable Vanes (AV)


Product code - Filter (example: MX - H14 - 3P3 - PU)
Filter frame height (a) –a –b –c –d
MD, MX, MG
Filter class (b)
H13, H14, U15
Filter size (c)
3P3, 3P6, 4P4, 5P5, 6P6, 9P6*, 9P9, 11P5,12P6
Sealing (d)
PU, GEL, DIN

www.camfil.com Camfil AB | CleanSeal | 7 Dec 2017/ 2


Cleanseal
Filter housing with HEPA filter

DIMENSIONS OF TERMINAL HOUSING

Cleanseal Side Entry Circular CL-S-C Installation


Opening

Installation Holes
Cleanseal Side Entry Rectangular CL-S-R Opening Dist.

Cleanseal Top Entry Circular CL-T-C Installation


Opening

www.camfil.com Camfil ABCamfil | CamSeal


| CleanSeal / 3 2017/ 3
| 7 Dec
Cleanseal
Filter housing with HEPA filter

FILTER

PU GEL DIN
Seamless polyurethane Silicone gel gasket Chloroprene rubber (CR),
gasket seals against knife the U-shape enables
edges in the housing gasket leakage test
(pressure decay).

DESCRIPTION FILTER FACTS


Application:
Camfil´s Megalam MD, MX, MG is an efficient, energy saving Hospitals, clean rooms and laboratories, etc.
HEPA/ULPA filter panel with low pressure drop and longer Type: HEPA filter
operating life. Every HEPA filter from filter class H13 and Frame: Anodised aluminium
above is individually scanned according to EN1822:2009 and Separators: Hot-melt beds
supplied with a test protocol. The filter media is pleated by Sealant: Polyurethane
machine with hot-melt beads separators in order to Media: Glass fibre
maximize the filtration a rea a nd g et a l ow p ressure d rop. Grid: Mild steel white (RAL 9010) epoxy paint, on
Choosing a deeper filter i ncreases t he fi lter ar ea, wh ich both sides
results in a lower pressure drop, reduced operating costs Gasket: Polyurethane (PU), Silicon gel (GEL), Chloro-
and a longer service life for the filters. All Megalam filters are prene rubber (DIN)
delivered with protection grids on both sides of the filter as Efficiency: > 99.995 % at MPPS for an H14 filter
standard, to make to filter handling easier and secure. Camfil according to EN1822
recommends a minimum pre filtration of at least filter class Recommended final pressure drop:
F7 (acc. to EN779:2012). With good pre filtration, the HEPA 2 x initial pressure drop
filter lasts longer and maintains a stable pressure drop level. Temperature/umidity: 70°C / 100% RH
Recommended final pressure drop should be determined after Note: Individually scanned according to EN
assessment of the dimensioning parameters, but a guideline 1822:2009, supplied with a protocol. Compliance
for final pressure drop could be twice the initial pressure drop. with ProSafe* requirements

*All certificates and further information available at


www.camfil.com/prosafe
FILTER DIMENSIONS
NOMINAL AIR FLOW WITH FILTER CLASS H14
MD, MX and MG filters with either PU, GEL or DIN gasket is
applicable to the housing Camfil recommends a nominal air flow of 0.45 m/s in
face velocity.

Note that a high face velocity might lead to filter failing


its filter class
www.camfil.com Camfil AB | CleanSeal | 7 Dec 2017/ 4
Cleanseal
Filter housing with HEPA filter

DETAILS

FILTER CLAMPING
Adjustable for different filter depths.

FILTER RETAINER DIFFUSER LOCK MOUNTING BRACKET


Holds the filter in position in The diffuser can be easily Can be adapted to false
the housing. opened with a card or similar. ceiling or suspended or used
Makes it possible for one The unlocked grid stays in T-Bar grid.
person to easily replace the hanging by its hinges.
filter.

EXAMPLE DESCRIPTION TEXT

Camfil's Cleanseal TERMINAL housing with HEPA filter and several AVAILABLE diffusers

Duct connected HEPA housing with room side filter change


Fully welded, airtight filter housing 1,5 mm steel, 2 layers epoxy painted (RAL9010)
Control port for measuring upstream aerosol concentration and differential pressure
Adjustable CLAMPING SYSTEM, allowing different heights of filter frame
The pre-positioning system is equipped with a tool-less filter clamping, and a filter retainer pre-positioning system
Air tightness of the housing Class L1 acc. EN1886. Air tightness at gasket seat acc. ISO EN 14644-3 at 450 Pa
(leakage less than 0,01% for H14)

Size: XPX
Connection: Top / Side connection, circular DN XXX/rectangular XXXx100mm
Filter: Megalam MD/MX/MG, Top / Side connection, circular DN XXX/rectangular XXXx100mm
Gasket : PU/GEL/DIN
Diffuser: Perforated / Swirl / Four Way / Adjustable Vanes / Nozzle

Cleanseal 6P6
CL-SW-6P6-P-MX-S-C-250-N-00-AAAO Quantity xx pc.
Cleanseal 3P6
CL-SW-3P6-P-MX-S-C-200-N-00-AAAO Quantity xx pc.