Counter-flow, high-efficiency heat recovery unit
DOMEO 210 Series
Whole house heat recovery unit with a
high-efficiency heat exchanger up to
92% setting and very low consumption
EC motor.
Provides a constant supply of fresh
tempered air into the living spaces
of a house.
Domeo can communicate with home
automation system via Modbus or other
gateway protocols. It also enables
management of a pre-heating or post
heating electric battery.
To optimise energy consumption and air
quality, it can be conected to a CO2 or
humidity sensor and others.
Domeo 210 is fitted with a 100% bypass
and it is equipped with M5 or F7 filters at
the inlet and with G4 filters at the outlet to
protect the heat exchanger.
Includes remote control, allowing
adjustment of boost (in RD and APP),
by-pass and reset of clogged filters.
Versions:
- DOMEO 210 FL 3V EU: Wired remote
control. 3 speeds.
- DOMEO 210 RD: Wireless remote
control (by radiofrequency). Constant
airflow motor.
- DOMEO 210 APP: Remote Control by
smartphone app. Constant airflow motor.
Features
• Counter-flow heat exchanger with up
to 92% thermal efficiency
• Low-consumption EC motor
• Centrifugal backward curved impeller
• Modbus communication
• EPP body
• Nozzles Ø125 mm
• 100% automatic or manual bypass
• Manual boost mode (RD and APP models)
• Inlet filter:
M5 (ISO ePM10 50%, at 210 m3/h).
Option, F7 (ISO ePM1 65%, at 210 m3/h).
• Extraction filter g4 (ISO coarse 65%, at
210 m3/h).
Controller. Very compact.
Remote control included Minimum width and depth.
in the product allows
regulation of:
DOMEO 210 FL 3V
• Boost function
(RD and APP models)
• By-pass Specific applications
• Polluted filters alarm
• Unoccupied mode
(RD and APP models)
Single Multi dwelling Heat recovery
dwellings blocks unit
www.solerpalau.com Heat recovery units DOMEO 210 209
Counter-flow, high-efficiency heat recovery unit
DOMEO 210 Series
Easy maintenance
Easy access to filters.
Easy to access: fans, heat exchanger and by-pass.
Technical characteristics
Model Efficiency Voltage Maximum airflow a 100 Pa Sound pressure level at 1,5 m Absorbed power
(%) (V) (m3/h) (120 m3/h - 70 Pa) (W)
(dB(A))
DOMEO 210 FL 3V EU 92 230 210 38,8 100
DOMEO 210 RD 92 230 210 38,8 100
DOMEO 210 APP 92 230 210 38,8 100
PERFORMANCE CURVES
psf psf DOMEO 210 FL 3V EU psf DOMEO 210 RD/APP
[mmcda] [Pa] [Pa]
550 550
55
500 500
50
450 450
45
400 400
40
35 350 350
30 300
300
25 250
250
20 200
200
15 150
150
10 100
100
5 50
50
0 0
0 50 100 150 200 250 qv [m3/h] 0
0 50 100 150 200 250 qv [m3/h]
Area of adjustable speed
Rdt (%)
95
94
93
92
91
90
89
88
87
86
85
0 50 100 150 200 250
Qv(m3/h)
210 Heat recovery units DOMEO 210 www.solerpalau.com
Counter-flow, high-efficiency heat recovery unit
DOMEO 210 Series
DOMEO 210 SERIES - CENTRALISED COUNTER-FLOW SYSTEM
1 5 6 4
8 2 3
7
1. Air inlet grillle TAP.
2. Self-adjusting extraction valve BARJ / BARP.
3. Supply and extraction valve BDOP.
4. PVC or rectangular plastic ducts.
5. Extraction plenum.
6. Supply plenum.
7. DOMEO 210: Counter-flow, high-efficiency heat recovery unit.
8. CT Roof termination.
www.solerpalau.com Heat recovery units DOMEO 210 211
Counter-flow, high-efficiency heat recovery unit
DOMEO 210 Series
Example of HEAT recovery in winter
19ºC 21ºC
Operation without bypass
2ºC
• Air inside home: 21ºC.
• Outdoor air: 2ºC.
• New air heated and blown into home: 19ºC.
With a mechanical extract ventilation system, the new air would enter
at 2ºC through the air inlets, decreasing the temperature inside home.
With the energy recovery ventilation systems, the new air would enter
at 19ºC.
Example of HEAT RECOVERY in summer during daytime Example of HEAT RECOVERY IN SUMMER NIGHTS
(free cooling)
24ºC 23ºC 20ºC 28ºC
34ºC 20ºC
Operation with bypass Operation with bypass
• Air inside home: 23ºC. • Air inside home: 28ºC.
• Outdoor air: 34ºC. • Outdoor air: 20ºC.
• New air heated and blown into home: 24ºC. • New air heated and blown into home: 20ºC.
With a mechanical extract ventilation system, the new air would enter at In addition, during summer nights, when outdoor air is colder than indoor
34ºC through the air inlets, increasing the temperature inside home. With air, the bypass is activated automatically so airflows do not cross each
the energy recovery ventilation systems, the new air would enter at 24ºC other.
and it will avoid the rising of interior temperature.
Heat recovery Fan By-pass Filter Kitchen Rooms Lounge W.C. Bath Outside the home
212 Heat recovery units DOMEO 210 www.solerpalau.com
Counter-flow, high-efficiency heat recovery unit
DOMEO 210 Series
DIMENSIONS (mm) 600 321
600 321 250
45
104
808
808
143,5 141 143,5
143,5 141 143,5
90
78
321
90
Ø1
25
78
321
Ø1
25
www.solerpalau.com Heat recovery units DOMEO 210 213
Counter-flow, high-efficiency heat recovery unit
DOMEO 210 Series
Mounting accessories
KIT M5/G4 DOMEO BARJ BDOP
Pack of M5 and G4 BARP Supply and
spare filters. Self-adjusting extraction valve.
calibrated extraction
valves.
RDR RD BP RD BP SM
Self-adjusting Specific low-pressure Specific low-pressure
damper (50-250 Pa) (20-100 Pa) and (20-100 Pa) and
that, fitted inside self-adjusting damper self-adjusting damper
the duct, maintains with sleeve to fit without sleeve to fit
constant airflow. directly into the duct. directly into the sleeve
80mm diameter. of the BDOP.
Airflow: 15 or 30 m3/h. 80mm diameter.
Airflow: 15 or 30 m3/h.
CT ADRF 100/80 GPR-ISO
Roof cowl. Reduction to Insulated rigid duct.
connect rigid duct to
spigots for flexible
ducts.
GP TUBPLA V TAT
GPX TUBPLA Air inlet grille under
GP-PRO Self-extinguishing roof.
GP-ISO rectangular ducts
with or without
insulated PVC gasket.
ducts .
TAP PAF PLENUM UNI EXT
Wall mounted air Wall outlet grille. 6+1
inlet grillle. Insulated extraction
plenum of 125/ 150-
160mm diameter,
1 Kitchen spigot of
125mm diameter
and up to 6 sanitary
spigots of 80mm
diameter.
PLENUM UNI IMP 8 LA FLEXIREC
Insulated supply Acoustic FLEXICIR
plenum of 125/150- connections. Oblong and circular
160 mm diameter semi-flexible ducts.
and up to 8 spigots
for dry areas (living
room, dining room,
bethrooms) of 80mm
diameter.
Electrical accessories
AIRSENS-CO2
AIRSENS-VOC
AIRSENS-HR
Intelligent IAQ device
available in three
different versions:
CO2 or VOC or RH.
214 Heat recovery units DOMEO 210 www.solerpalau.com