HPE MSA 1060 - 2060 - 2062 Drive Replacement Instructions
HPE MSA 1060 - 2060 - 2062 Drive Replacement Instructions
HPE MSA 1060 - 2060 - 2062 Drive Replacement Instructions
Instructions
Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise
products and services are set forth in the express warranty statements accompanying such products and services. Nothing
herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical
or editorial errors or omissions contained herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use, or copying.
Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical
Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard Enterprise has no
control over and is not responsible for information outside the Hewlett Packard Enterprise website.
Before you begin
• Before proceeding with drive replacement, check the following:
◦ Confirm that the drive is a member of a fault-tolerant configuration that permits removing one or more drives without
risking data loss.
◦ If multiple drives have failed and need replacing, determine how many drives can be replaced at the same time. The
number of drives that can fail and be replaced without data loss is determined by the fault-tolerance level of the
configuration.
• Leave failed modules in the enclosure until you are ready to install the replacement module. Removing a module from an
operational enclosure significantly changes air flow within the enclosure. Openings must be populated for the enclosure to
cool properly.
• Parts can be damaged by electrostatic discharge. Keep parts in electrostatic containers until needed and ensure you are
properly grounded when touching static-sensitive components.
• Use care when handling drives. Drives are sensitive electromechanical devices that can be permanently damaged through
improper handling. Keep drives in their original, protective packaging until installation.
• The replacement drive module must be of the same type, and possess capacity equal to or greater than the one being
replaced.
• For additional information on replacing drives, see the Hewlett Packard Enterprise website documentation listed under
Resources.
Procedure
• Check notifications, array system event logs, product-specific logs, and management utilities for drive health and location
information.
• Check enclosure status LEDs.
• Check drive LEDs, as described in the following images and table.
3
1
On Drive faulted.
Blink (3 sec on / 1 sec off) Drive has been identified by management application (SMU or CLI)
4
Removing the failed drive
CAUTION: Prolonged use of the array, while one or more drives slots are not covered by either a drive or drive blank
module, can result in damage to the system from overheating.
Procedure
IMPORTANT: For drives with rotating media, wait approximately 30 seconds or until the media stops rotating
before removing the drive from the enclosure.
5
Installing the replacement drive
Prerequisites
CAUTION: Wait approximately 60 seconds after removing the failed drive before installing the replacement drive. This
amount of time allows the enclosure to recognize that a drive was removed. Removal of a drive prepares the enclosure
to recognize a replacement drive when it is installed.
Procedure
1. On the replacement drive, prepare the drive by pressing the drive latch (1) and pivoting the release lever (2) to the full
open position.
6
1
1
2
NOTE: In an FDE-secured system, any drive that does not already have disk group information is automatically secured
using the system lock keys. See HPE MSA 1060/2060/2062 Storage Management Guide and HPE MSA 1060/2060/2062
CLI Reference Guide for instructions on including or repurposing Self-Encrypting Drives (SEDs) that have existing disk
group metadata.
7
Verifying drive status
Procedure
Procedure
1. In the SMU, verify the status of the drive slot in which the replacement drive is installed is available (AVAIL). All new drives
should be Available. If the status is a different value, see the user guides or guided troubleshooting listed under Websites,
and determine the appropriate action.
2. When the replacement drive is online with a status of available (AVAIL), verify that your firmware is up to date. If you need
to update the firmware to the latest version, see Updating firmware.
3. Configure the drive to be a spare.
• To add a spare using the CLI, use the add spares command.
Example showing how to designate disk 1.2 as a global spare:
# add spares 1.2
NOTE: Spare drives and replacement process may differ with advanced RAID levels. Refer to HPE MSA 1060/2060/2062
Storage Management Guide if the process is not reporting as expected, and you are using advanced RAID Levels.
For information about disk group reconstruction and using the SMU, see the Hewlett Packard Enterprise documentation
website listed under Websites.
Updating firmware
After installing any new component, verify that it is running the latest firmware.
8
Procedure
9
Websites
GENERAL WEBSITES
Hewlett Packard Enterprise Information Library
www.hpe.com/info/EIL
Single Point of Connectivity Knowledge (SPOCK) Storage compatibility matrix
www.hpe.com/storage/spock
HPE Support
https://support.hpe.com/hpesc/public/home/
Storage white papers and analyst reports
www.hpe.com/storage/whitepapers
MSA WEBSITES
MSA QuickSpecs
http://www.hpe.com/info/qs
MSA Manuals
https://www.hpe.com/info/MSAdocs
MSA Firmware
https://www.hpe.com/storage/MSAFirmware
MSA Drive Firmware
https://www.hpe.com/storage/MSADriveFirmware
HPE MSA Support Material Access
http://www.hpe.com/storage/MSASupportMaterialAccess
MSA Health Check
www.hpe.com/storage/MSAHealthCheck
Websites 10
Support and other resources
Information to collect
• Technical support registration number (if applicable)
• Product name, model or version, and serial number
• Operating system name and version
• Firmware version
• Error messages
• Product-specific reports and logs
• Add-on products or components
• Third-party products or components
Accessing updates
• Some software products provide a mechanism for accessing software updates through the product interface. Review your
product documentation to identify the recommended software update method.
• To download product updates:
Hewlett Packard Enterprise Support Center
www.hpe.com/support/hpesc
Hewlett Packard Enterprise Support Center: Software downloads
www.hpe.com/support/downloads
Software Depot
www.hpe.com/support/softwaredepot
• To subscribe to eNewsletters and alerts:
www.hpe.com/support/e-updates
• To view and update your entitlements, and to link your contracts and warranties with your profile, go to the Hewlett
Packard Enterprise Support Center More Information on Access to Support Materials page:
www.hpe.com/support/AccessToSupportMaterials
Remote support
Remote support is available with supported devices as part of your warranty or contractual support agreement. It provides
intelligent event diagnosis, and automatic, secure submission of hardware event notifications to Hewlett Packard Enterprise,
which will initiate a fast and accurate resolution based on your product's service level. Hewlett Packard Enterprise strongly
recommends that you register your device for remote support.
If your product includes additional remote support details, use search to locate that information.
Warranty information
To view the warranty information for your product, see the links provided below:
HPE ProLiant and IA-32 Servers and Options
www.hpe.com/support/ProLiantServers-Warranties
HPE Enterprise and Cloudline Servers
www.hpe.com/support/EnterpriseServers-Warranties
HPE Storage Products
www.hpe.com/support/Storage-Warranties
HPE Networking Products
www.hpe.com/support/Networking-Warranties
Documentation feedback
Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the
documentation, send any errors, suggestions, or comments to Documentation Feedback ([email protected]). When
submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of
the document. For online help content, include the product name, product version, help edition, and publication date located on
the legal notices page.