Simulate The Circuit in Fluidsim and Perform The Actual Setup Using The Trainer
Simulate The Circuit in Fluidsim and Perform The Actual Setup Using The Trainer
Simulate The Circuit in Fluidsim and Perform The Actual Setup Using The Trainer
Exercise/Activity No. 3
Direction: Design the pneumatic and electric circuit to implement the task described below.
Simulate the circuit in FluidSIM and perform the actual setup using the trainer.
A press stamp 1.0 is to advance only if a push button is actuated and a protective guard is closed. If one
of these conditions is not met, the press tool is to return immediately.
The position of the closed protective guard is monitored by a proximity switch B1. The press tool is
advanced or retracted by means of a spring return solenoid valve (Coil Y1).
Positional Sketch
A. Pneumatic circuit
B. Electric circuit
Basically, this assembly is a series circuit. The push button with detent(B1) serves as the
switch for the protective guard, while the manually actuated push button (S1) is for the press stamp
(1.0) actuation. If B1 is pressed the protective guard is closed, consequently, if S1 is pressed the
cylinder will actuate. On the other hand, B1 is unpressed the connection is cut; therefore the current
won’t continue. Thus, this assembly satisfies the problem requirements.