GX Developer Version 8 Operating Manual (Startup) Sh080372el
GX Developer Version 8 Operating Manual (Startup) Sh080372el
(2) The PRODUCT has been designed and manufactured for the purpose of being used in general
industries.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT LIMITED
TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT,
PRODUCT LIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO
PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT
INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR WARNING CONTAINED IN
MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICAL BULLETINS AND
GUIDELINES FOR the PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the PRODUCT in;
y Nuclear Power Plants and any other power plants operated by Power companies, and/or any other
cases in which the public could be affected if any problem or fault occurs in the PRODUCT.
y Railway companies or Public service purposes, and/or any other cases in which establishment of a
special quality assurance system is required by the Purchaser or End User.
y Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as Elevator
and Escalator, Incineration and Fuel devices, Vehicles, Manned transportation, Equipment for
Recreation and Amusement, and Safety devices, handling of Nuclear or Hazardous Materials or
Chemicals, Mining and Drilling, and/or other applications where there is a significant risk of injury to
the public or property.
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the
PRODUCT in one or more of the Prohibited Applications, provided that the usage of the PRODUCT is
limited only for the specific applications agreed to by Mitsubishi and provided further that no special
quality assurance or fail-safe, redundant or other safety features which exceed the general
specifications of the PRODUCTs are required. For details, please contact the Mitsubishi
representative in your region.
A-1 A-1
REVISIONS
The manual number is given on the bottom left of the back cover.
Print Date Manual Number Revision
Feb., 2003 SH(NA)-080372E-A First edition
Jul., 2003 SH(NA)-080372E-B Correction
Appendix 2
Jun., 2004 SH(NA)-080372E-C Correction
Section 2.2, Chapter 3, Section 3.1.2, Section 4.1
Apr., 2005 SH(NA)-080372E-D Correction
Section 2.2
Jun., 2005 SH(NA)-080372E-E Correction
Section 2.2
Apr., 2007 SH(NA)-080372E-F Correction
Section 2.2
Jan., 2008 SH(NA)-080372E-G Addition
Section 3.4
Correction
Abbreviations and Generic Terms in This Manual, Section 2.2,
Section 3.1.2, Section 3.2, Section 3.3
Apr., 2008 SH(NA)-080372E-H Correction
Section 3.1.2
Jun., 2008 SH(NA)-080372E-I Correction
Section 2.2, Section 3.2
Dec., 2008 SH(NA)-080372E-J Correction
Section 2.2
Apr., 2009 SH(NA)-080372E-K Correction
SOFTWARE USER REGISTRATION, About Manuals,
Product Makeup, Section 3.1.2, Section 3.3
Jan., 2010 SH(NA)-080372E-L Addition
CONDITIONS OF USE FOR THE PRODUCT
Correction
INTRODUCTION, About Manuals,
Abbreviations and Generic Terms in This Manual, Product Makeup,
Section 2.2, Section 3.3
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses.
Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which
may occur as a result of using the contents noted in this manual.
© 2003 MITSUBISHI ELECTRIC CORPORATION
A-2 A-2
INTRODUCTION
Thank you for choosing the Mitsubishi MELSOFT series Integrated FA software.
Read this manual and make sure you understand the functions and performance of MELSOFT series
programmable controller thoroughly in advance to ensure correct use.
CONTENTS
1. GENERAL DESCRIPTION 1- 1 to 1- 2
2. SYSTEM CONFIGURATION 2- 1 to 2- 2
4. USING GX Developer 4- 1 to 4- 6
A-3 A-3
About Manuals
Related Manuals
Manual Number
Manual Name
(Model Code)
GX Developer Version8 Operating Manual
SH-080373E
Explains operation methods such as creating, printing, monitoring, and debugging programs using GX
(13JU40)
Developer. (Sold separately)
REMARK
The Operating Manuals and Structured Text (ST) Programming Guide Book are
included on the CD-ROM of the software package in a PDF file format.
Manuals in printed form are sold separately for single purchase. Order a manual by
quoting the manual number (model code) listed in the table above.
A-4 A-4
Abbreviations and Generic Terms in This Manual
Unless otherwise specified, the following generic names and abbreviations are used
for explanations in this manual.
A-5 A-5
Product Makeup
NOTICES
• We don't guarantee the commercially-available Microsoft Windows Operating
R R
A-6 A-6
1 GENERAL DESCRIPTION
MELSOFT
1. GENERAL DESCRIPTION
1
This manual describes the system configuration, installation procedure, start method,
screen configuration, and basic operations of the following Microsoft Windows Operating
R R
Install procedure
System configuration
GX
Developer
End
GX
Developer
1-1 1-1
1 GENERAL DESCRIPTION
MELSOFT
MEMO
1
1-2 1-2
2 SYSTEM CONFIGURATION
MELSOFT
2. SYSTEM CONFIGURATION
GX Developer is available to install into the PC that meets the operating environment
specification in Section 2.2.
2
Item Contents
Personal Personal computer in which Windows operates.
R
Peripheral computer
device PC CPU MELSEC-Q Series-compatible PC CPU module (CONTEC CO., Ltd.)
module
Personal CPU See "Applicable operating system and the corresponding required PC performance"
computer main Required shown below.
body memory
1
Available hard disk space 200MB or more
Disk drive CD-ROM drive (if using CD-ROM media)
Resolution
2
800x600 pixels or higher
Monitor
However, set the resolution to 1024x768 pixels or higher when using the CC IE Control
diagnostics function.
RS-232 port : Needed when communicating with the programmable controller CPU.
(Required when accessing the Basic model QCPU, QCPU (A mode),
ACPU, QnACPU, and FXCPU)
USB port : Can be used when communicating with the QCPU (Q mode), LCPU,
Communication interface
QSCPU, FXCPU(FX3G).
(Excludes the Basic model QCPU, Q02CPU and remote I/O modules.)
Ethernet port : Can be used when communicating with the Built-in Ethernet port QCPU
and LCPU
3
Microsoft R
Windows 95 Operating System
R
Microsoft R
Windows 98 Operating System
R
Microsoft R
Windows Millennium Edition Operating System
R
Microsoft R
WindowsNT Workstation Operating System Version 4.0
R
Microsoft R
Windows 2000 Professional Operating System
R
Microsoft R
Windows XP Professional Operating System
R
Operating system
Microsoft R
Windows XP Home Edition Operating System
R
R R
Microsoft Windows Vista Home Basic Operating System
R R
Microsoft Windows Vista Home Premium Operating System
R R
Microsoft Windows Vista Business Operating System
R R
Microsoft Windows Vista Ultimate Operating System
R R
Microsoft Windows Vista Enterprise Operating System
1: At minimum, free space of 15GB is required for Windows Vista . R
2-1 2-1
2 SYSTEM CONFIGURATION
MELSOFT
Required PC performance
Item
CPU Required memory
4 5
Windows 95 (Service Pack 1 or higher)
R
Pentium 133MHz or higher
R
32MB or more
4 5
Windows 98
R
Pentium 133MHz or higher
R
32MB or more
2 Windows Millennium Edition
R
Pentium 150MHz or higher
R 4
32MB or more
5
4 5
WindowsNT Workstation 4.0 (Service Pack 3 or higher)
R
Pentium 133MHz or higher
R
32MB or more
4 5
Windows 2000 Professional
R
Pentium 133MHz or higher
R
64MB or more
4 5
Windows XP Professional
R
Pentium 300MHz or higher
R
128MB or more
4 5
Windows XP Home Edition
R
Pentium 300MHz or higher
R
128MB or more
Windows Vista R
Home Basic Pentium 1GHz or higher
R
1GB or more
Windows Vista R
Home Premium Pentium 1GHz or higher
R
1GB or more
Windows Vista R
Business Pentium 1GHz or higher
R
1GB or more
Windows Vista R
Ultimate Pentium 1GHz or higher
R
1GB or more
Windows Vista R
Enterprise Pentium 1GHz or higher
R
1GB or more
4: Pentium 300MHz or higher is recommended when creating label programs.
R
POINT
• Instruction for use of the online manual
Addition of memory ensures more comfortable use.
• Instruction for use of the PDF data
Use with addition of personal computer memory ensures comfortable operation.
• Depending on the operating environment of the personal computer, editing on
multiple screens opened for programming or like may cause a memory shortage
error.
When the personal computer is used with only GX Developer booted, the number
of edit screens should be up to 40 as a guideline.
• When Microsoft Windows XP or Windows Vista is used, the following new
R R R
2-2 2-2
3 INSTALLATION AND UNINSTALLATION
MELSOFT
3.1 Installation
Complete
POINT
If the DLL overwrite confirmation message appears during installation, choose
"Yes" to overwrite the DLLs.
If they are not overwritten, the product may not be run properly.
3-1 3-1
3 INSTALLATION AND UNINSTALLATION
MELSOFT
POINT
• Terminate all the other applications running under Microsoft Windows Operating
R R
Operating System, logon as a user who has the attributes of an Administrator (for
computer management).
• If the license key FD is valid, installing this product enables updating.
(The license volume of the older version decreases by 1 license.)
[Windows Explorer].
: When user account control is enabled in Windows
Double-click here Vista , the following screen appears.
R
Click "Allow".
3-2 3-2
3 INSTALLATION AND UNINSTALLATION
MELSOFT
3-3 3-3
3 INSTALLATION AND UNINSTALLATION
MELSOFT
When newly installing the product, the left screen does not
appear.
3-4 3-4
3 INSTALLATION AND UNINSTALLATION
MELSOFT
3-5 3-5
3 INSTALLATION AND UNINSTALLATION
MELSOFT
first installation.
Click Continue button.
We checked operations in Windows XP (Problems
R
3-6 3-6
3 INSTALLATION AND UNINSTALLATION
MELSOFT
left appears.
(Completion)
REMARK
When Windows XP Professional or Windows Vista is used, the icons are
R R
3-7 3-7
3 INSTALLATION AND UNINSTALLATION
MELSOFT
POINT
Note the following instructions when the installer is started from the hard disk drive
of the personal computer for which Windows Vista has been installed.
R
3-8 3-8
3 INSTALLATION AND UNINSTALLATION
MELSOFT
OS File name
Microsoft Windows 95 Operating System
R R
dcom95.exe
Microsoft Windows 98 Operating System
R R
Axdist.exe
Microsoft Windows NT Workstation Operating System Version 4.0 Axdist.exe
R R
3-9 3-9
3 INSTALLATION AND UNINSTALLATION
MELSOFT
screen appears.
Click "Allow".
: After executing the above exe file, reinstall the product. If this product is
not installed properly at this time, reboot the personal computer.
3 - 10 3 - 10
3 INSTALLATION AND UNINSTALLATION
MELSOFT
3 - 11 3 - 11
3 INSTALLATION AND UNINSTALLATION
MELSOFT
3.2 Uninstallation
This section describes the operation for removing the product form the hard disk.
REMARKS
When using Windows XP , choose "Add or Remove
R
REMARKS
The screen shown on the left is that of Windows 98.
R
3 - 12 3 - 12
3 INSTALLATION AND UNINSTALLATION
MELSOFT
(Completion)
3 - 13 3 - 13
3 INSTALLATION AND UNINSTALLATION
MELSOFT
If you have selected "Block-Never install unsigned driver software" after [Control
Panel] - [System] - [Hardware] - [Driver Signing], the USB driver may not be
installed.
Choose "Ignore-Install the software anyway and don't ask for my approval" or
"Warn-Prompt me each time to choose an action" for [Driver Signing], and install
the USB driver.
• When the FXCPU is used
Since a USB driver depends on a connected device, install the driver according to
the connected device.
(1) When connecting to the built-in USB port of the FX3G
Install the USB driver stored to the installation location of GX Developer,
"Easysocket\USBDrivers".
(2) When connecting to the USB port of the FX-USB-AW or FX3U-USB-BD
1
Install the USB driver on the CD-ROM included with the FX-USB-AW or
FX3U-USB-BD.
For how to install the driver, refer to the following manual.
• FX-USB-AW/FX3U-USB-BD User’s Manual – USB Driver Installation Edition
1 GX Developer Version8.72A or later stores a USB driver for the FX-USB-AW
and FX3U-USB-BD to its installation location, "Easysocket\FXOptionDrivers".
3 - 14 3 - 14
3 INSTALLATION AND UNINSTALLATION
MELSOFT
The following indicates the procedure for installing the USB driver when using
Windows 2000 Professional.
R
3 - 15 3 - 15
3 INSTALLATION AND UNINSTALLATION
MELSOFT
(Completion)
3 - 16 3 - 16
3 INSTALLATION AND UNINSTALLATION
MELSOFT
The following indicates the procedure for installing the USB driver when using
Windows XP.
R
REMARKS
Though the screen on the left appears during installation
of the USB driver, we have confirmed that the USB driver
operates properly using Windows XP. R
3 - 17 3 - 17
3 INSTALLATION AND UNINSTALLATION
MELSOFT
(Completion)
3 - 18 3 - 18
3 INSTALLATION AND UNINSTALLATION
MELSOFT
The following shows installation procedure of USB driver when using Windows
Vista .
R
3 - 19 3 - 19
3 INSTALLATION AND UNINSTALLATION
MELSOFT
(Completion)
3 - 20 3 - 20
3 INSTALLATION AND UNINSTALLATION
MELSOFT
before installing Windows Vista -compatible MELSOFT, updating the USB driver is
R
required.
Update the USB driver after installing Windows Vista -compatible MELSOFT.
R
(1) Procedure for updating the USB driver for programmable controller
connection
(a) Checking method
Whether an update of the USB driver is required or not can be checked by
its version.
Start the Windows Device Manager while the personal computer is
connected to the programmable controller with USB, right-click
"MITSUBISHI Easysocket Driver", and select [Properties].
Update is necessary when the "Driver Version" is "2.0.0.0" or earlier in the
"Driver" tab of the properties screen.
3 - 21 3 - 21
3 INSTALLATION AND UNINSTALLATION
MELSOFT
3 - 22 3 - 22
3 INSTALLATION AND UNINSTALLATION
MELSOFT
REMARKS
If multiple ‘unknown devices’ exist therefore cannot be
specified, right-click "Unknown device" as shown left
and select [Properties]. The "Unknown device", whose
"Hardware Ids" is "USB\VID_06D3&PID_1800" on the
"Details" tab of the properties screen, is the update
target.
3 - 23 3 - 23
3 INSTALLATION AND UNINSTALLATION
MELSOFT
↓
(Completion)
3 - 24 3 - 24
3 INSTALLATION AND UNINSTALLATION
MELSOFT
(2) Procedure for updating the USB driver for GOT connection
(a) Checking method
Reset the power on the GOT and start the Windows Device Manager while the
personal computer is connected to the GOT with USB. If "MITSUBISHI
GOT1000 USB Controller" is not displayed under "Universal Serial Bus
controllers", but "Unknown device" is displayed under "Other devices", the
device needs to be updated.
The "Unknown device", whose "Hardware Ids" is "USB\VID_06D3&PID_01E0"
on the "Details" tab of the properties screen, is the update target.
3 - 25 3 - 25
3 INSTALLATION AND UNINSTALLATION
MELSOFT
(Completion)
3 - 26 3 - 26
4 USING GX Developer
MELSOFT
4. USING GX Developer
This section describes the GX Developer window configuration and various tools.
(1) Title bar
(4) Toolbar
4-1 4-1
4 USING GX Developer
MELSOFT
4
(3) Drop-down menu
Displays the names of GX Developer functions.
When " " is displayed at the rightmost end of the menu item, the drop-down
menu of the selected item is displayed.
When " ..." is displayed next to a function name, a setup dialog box is displayed by
selecting the item.
4-2 4-2
4 USING GX Developer
MELSOFT
(4) Toolbar
Displays the buttons for the frequently used functions assigned on the menu bar.
Displays information concerning the mouse cursor position. Indicates the Caps Lock status.
Indicates the CPU type. Indicates the destination CPU. Indicates the current mode.
4-3 4-3
4 USING GX Developer
MELSOFT
(7) Tab
4-4 4-4
4 USING GX Developer
MELSOFT
(7) Tab
For tab switching, click the desired tab in the property pages dialog box.
4-5 4-5
4 USING GX Developer
MELSOFT
MEMO
4-6 4-6
APPENDICES
MELSOFT
APPENDICES
APPENDIX 1 Questions and Answers about Personal Computers
This section provides basic information in question & answer style Please see the
following information as necessary.
Q1. What happens when the monitor with a resolution of 800x600 pixels or lower is
used?
A1. The icon near the edges of the screen may not be displayed entirely, so that
the operations cannot be performed using that icon.
Read the manual and set the dedicated resolution high enough to display the
entire icon.
APP
Q3. Is the MELSOFT software package available under Microsoft Windows 3.1
R R
operating system?
A3. The MELSOFT software package is not available under Windows 3.1. R
A4. When the clock speed of the CPU is slower than 133MHz, it takes longer for
operations such as screen display.
Appendix - 1 Appendix - 1
APPENDICES
MELSOFT
This section lists the questions and answers to assist you in solving the problems
encountered during GX Developer operation.
Q1. Each circuit diagram is enclosed in white lines during circuit editing depending
on the type of video card installed in the personal computer (card storing the
characters, figures, and pictures to be displayed on the monitor as data).
How can these white lines be deleted?
A1. Make necessary settings from the Windows 95/ Windows 98/ Windows Me/
R R R
Operating procedure
(1) Open "Control Panel".
(5) Set "Hardware acceleration" to the entry (second entry) next to "None".
APP
Q2. What action should be taken for the message "Can not allocate Share
memory" or "Initialization failed" displayed at the start of the GX Developer
software package?
Q3. Why does it take time to display the dialog box after starting setup.exe on
Section 3.1.2?
A3. It takes time when the memory-resident program (such as Virus checker) is
running.
Appendix - 2 Appendix - 2
APPENDICES
MELSOFT
When the system does not work well after the step 1) has been
performed, install Windows 95/ Windows 98/ Windows NT
R R R
Appendix - 3 Appendix - 3
APPENDICES
MELSOFT
Q5. When a program is read from a floppy disk, it cannot be read from the floppy
disk so long as the disk is write protected. Why not?
A5. Because multiple GX Developer can be started, access to files in the same
floppy disk may occur simultaneously. In such a case, an access flag is
written to a floppy disk at the time of floppy disk access to prevent the files in
the disk from being accessed from another GX Developer.
Namely, no files can be read in this system so long as the floppy disk is write
protected.
Appendix - 4 Appendix - 4
APPENDICES
MELSOFT
MEMO
Appendix - 5 Appendix - 5
Microsoft, Windows, Windows NT, Windows Vista are registered trademarks of Microsoft Corporation in
the United States and other countries.
Pentium is a trademark of Intel Corporation in the United States and other countries.
All other company names and product names used in this manual are trademarks or registered
trademarks of their respective companies.
SPREAD
Copyright (C) 1998 Farpoint Technologies, Inc.
SH(NA)-080372E-L