Fluent Vof
Fluent Vof
In addition, ANSYS Fluent offers a Full Multiphase Coupled solver where all velocities, pressure correction
and volume fraction correction are solved simultaneously, which currently is not as robust as the others.
Furthermore, ANSYS Fluent has an option to solve stratified immiscible fluids within the Eulerian mul-
tiphase formulation. This feature is similar to the single fluid VOF solution, but in the context of multiple
velocities.
• You must use the pressure-based solver. The VOF model is not available with the density-based solver.
• All control volumes must be filled with either a single fluid phase or a combination of phases. The VOF
model does not allow for void regions where no fluid of any type is present.
• Only one of the phases can be defined as a compressible ideal gas. There is no limitation on using com-
pressible liquids using user-defined functions.
• Streamwise periodic flow (either specified mass flow rate or specified pressure drop) cannot be modeled
when the VOF model is used.
• The second-order implicit time-stepping formulation cannot be used with the VOF explicit scheme.
• When tracking particles in parallel, the DPM model cannot be used with the VOF model if the shared
memory option is enabled (Parallel Processing for the Discrete Phase Model in the User's Guide). (Note
that using the message passing option, when running in parallel, enables the compatibility of all multiphase
flow models with the DPM model.)
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
474 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
The VOF formulation relies on the fact that two or more fluids (or phases) are not interpenetrating. For
each additional phase that you add to your model, a variable is introduced: the volume fraction of the
phase in the computational cell. In each control volume, the volume fractions of all phases sum to unity.
The fields for all variables and properties are shared by the phases and represent volume-averaged
values, as long as the volume fraction of each of the phases is known at each location. Thus the variables
and properties in any given cell are either purely representative of one of the phases, or representative
of a mixture of the phases, depending upon the volume fraction values. In other words, if the
fluid’s
volume fraction in the cell is denoted as , then the following three conditions are possible:
•
= : The cell is full (of the
fluid).
<
• < : The cell contains the interface between the fluid and one or more other fluids.
Based on the local value of , the appropriate properties and variables will be assigned to each control
volume within the domain.
where $
ɺ %& is the mass transfer from phase ' to phase ( and )
ɺ *+ is the mass transfer from phase ,
to phase -. By default, the source term on the right-hand side of Equation 17.8 (p. 475), ./ , is zero, but
0
you can specify a constant or user-defined mass source for each phase. See Modeling Mass Transfer in
Multiphase Flows (p. 579) for more information on the modeling of mass transfer in ANSYS Fluent’s
general multiphase models.
The volume fraction equation will not be solved for the primary phase; the primary-phase volume
fraction will be computed based on the following constraint:
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 475
Multiphase Flows
∑ = (17.9)
=
The volume fraction equation may be solved either through implicit or explicit time discretization.
ɺ
(17.10)
=
Since this equation requires the volume fraction values at the current time step (rather than at the
previous step, as for the explicit scheme), a standard scalar transport equation is solved iteratively for
each of the secondary-phase volume fractions at each time step.
The implicit scheme can be used for both time-dependent and steady-state calculations. See Choosing
a Volume Fraction Formulation in the User's Guide for details.
where
" + = index for new (current) time step
# = index for previous time step
$ % ' & = face value of the ( )* volume fraction, computed from the first- or second-
order upwind, QUICK, modified HRIC, compressive, or CICSAM scheme
+ = volume of cell
, - = volume flux through the face, based on normal velocity
This formulation does not require iterative solution of the transport equation during each time step, as
is needed for the implicit scheme.
Important
When the explicit scheme is used for time discretization, the face fluxes can be interpolated either using
interface reconstruction or using a finite volume discretization scheme (Interpolation Near the Inter-
face (p. 477)). The schemes available in ANSYS Fluent for the explicit formulation are discussed in Explicit
Schemes in the User's Guide.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
476 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
In the geometric reconstruction and donor-acceptor schemes, ANSYS Fluent applies a special interpolation
treatment to the cells that lie near the interface between two phases. Figure 17.2: Interface Calcula-
tions (p. 477) shows an actual interface shape along with the interfaces assumed during computation
by these two methods.
The explicit scheme and the implicit scheme treat these cells with the same interpolation as the cells
that are completely filled with one phase or the other (that is, using the standard upwind (First-Order
Upwind Scheme (p. 633)), second-order (Second-Order Upwind Scheme (p. 634)), QUICK (QUICK
Scheme (p. 636)), modified HRIC (Modified HRIC Scheme (p. 638)), compressive (The Compressive and
Zonal Discretization Schemes (p. 479)), or CICSAM scheme (The Compressive Interface Capturing Scheme
for Arbitrary Meshes (CICSAM) (p. 479)), rather than applying a special treatment.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 477
Multiphase Flows
The geometric reconstruction scheme represents the interface between fluids using a piecewise-linear
approach. In ANSYS Fluent this scheme is the most accurate and is applicable for general unstructured
meshes. The geometric reconstruction scheme is generalized for unstructured meshes from the work
of Youngs [504] (p. 756). It assumes that the interface between two fluids has a linear slope within each
cell, and uses this linear shape for calculation of the advection of fluid through the cell faces. (See Fig-
ure 17.2: Interface Calculations (p. 477).)
The first step in this reconstruction scheme is calculating the position of the linear interface relative to
the center of each partially-filled cell, based on information about the volume fraction and its derivatives
in the cell. The second step is calculating the advecting amount of fluid through each face using the
computed linear interface representation and information about the normal and tangential velocity
distribution on the face. The third step is calculating the volume fraction in each cell using the balance
of fluxes calculated during the previous step.
Important
The orientation of the interface is also used in determining the face fluxes. The interface orientation is
either horizontal or vertical, depending on the direction of the volume fraction gradient of the
phase within the cell, and that of the neighbor cell that shares the face in question. Depending on the
interface’s orientation as well as its motion, flux values are obtained by pure upwinding, pure down-
winding, or some combination of the two.
Important
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
478 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
no two-sided (zero-thickness) walls within the domain. If there are, you will need to slit them,
as described in Slitting Face Zones in the User's Guide.
17.3.4.3.3. The Compressive Interface Capturing Scheme for Arbitrary Meshes (CICSAM)
The compressive interface capturing scheme for arbitrary meshes (CICSAM), based on Ubbink’s work
[457] (p. 754), is a high resolution differencing scheme. The CICSAM scheme is particularly suitable for
flows with high ratios of viscosities between the phases. CICSAM is implemented in ANSYS Fluent as
an explicit scheme and offers the advantage of producing an interface that is almost as sharp as the
geometric reconstruction scheme.
where
is the face VOF value
is the donor cell VOF value
is the slope limiter value
∇
is the donor cell VOF gradient value
• The slope limiter for the compressive scheme is bound between 0 and 2. This scheme is available for
the VOF model, for both the implicit and explicit volume fraction schemes. It is also available for the Eu-
lerian multiphase model when the explicit scheme for the volume fraction is selected. Note that the
compressive scheme can be made available for the Eulerian multiphase model when the implicit volume
fraction scheme is selected as described in Implicit Schemes in the User's Guide.
• The slope limiter for the zonal discretization and phase localized compressive schemes can be summarized
in the table below:
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 479
Multiphase Flows
Note
3. = represents the compressive scheme described above, where the slope limiter is
bounded between 0 and 2.
• The slope limiter for the phase localized compressive scheme is calculated based on the specified values
of the interfacial slope limiters.
In general, for an
-phase system, the volume-fraction-averaged density takes on the following form:
= ∑
(17.14)
All other properties (for example, viscosity) are computed in this manner.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
480 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
One limitation of the shared-fields approximation is that in cases where large velocity differences exist
between the phases, the accuracy of the velocities computed near the interface can be adversely affected.
Note that if the viscosity ratio is more than , this may lead to convergence difficulties. The com-
pressive interface capturing scheme for arbitrary meshes (CICSAM) (The Compressive Interface Capturing
Scheme for Arbitrary Meshes (CICSAM) (p. 479)) is suitable for flows with high ratios of viscosities between
the phases, therefore solving the problem of poor convergence.
where for each phase is based on the specific heat of that phase and the shared temperature.
The properties and (effective thermal conductivity) are shared by the phases. The source term,
, contains contributions from radiation, as well as any other volumetric heat sources.
As with the velocity field, the accuracy of the temperature near the interface is limited in cases where
large temperature differences exist between the phases. Such problems also arise in cases where the
properties vary by several orders of magnitude. For example, if a model includes liquid metal in com-
bination with air, the conductivities of the materials can differ by as much as four orders of magnitude.
Such large discrepancies in properties lead to equation sets with anisotropic coefficients, which in turn
can lead to convergence and precision limitations.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 481
Multiphase Flows
the phases and the walls, as well as the at porous jumps. You can specify a surface tension coefficient
as a constant, as a function of temperature through a polynomial, or as a function of any variable
through a UDF. The solver will include the additional tangential stress terms (causing what is termed
as Marangoni convection) that arise due to the variation in surface tension coefficient. Variable surface
tension coefficient effects are usually important only in zero/near-zero gravity conditions.
In ANSYS Fluent, two surface tension models exist: the continuum surface force (CSF) and the continuum
surface stress (CSS). The two models are described in detail in the sections that follow.
Note
The calculation of surface tension effects on triangular and tetrahedral meshes is not as ac-
curate as on quadrilateral and hexahedral meshes. The region where surface tension effects
are most important should therefore be meshed with quadrilaterals or hexahedra.
In ANSYS Fluent, a formulation of the CSF model is used, where the surface curvature is computed from
local gradients in the surface normal at the interface. Let be the surface normal, defined as the
gradient of , the volume fraction of the
phase.
= ∇ (17.19)
The curvature, , is defined in terms of the divergence of the unit normal, ɵ [41] (p. 731):
= ∇ ⋅ ɵ (17.20)
where
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
482 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
ɵ= (17.21)
The surface tension can be written in terms of the pressure jump across the surface. The force at the
surface can be expressed as a volume force using the divergence theorem. It is this volume force that
is the source term that is added to the momentum equation. It has the following form:
∇ + ∇
= ∑ (17.22)
< +
This expression allows for a smooth superposition of forces near cells where more than two phases are
present. If only two phases are present in a cell, then = − and ∇ = − ∇ , and Equa-
tion 17.22 (p. 483) simplifies to
∇
= ! " (17.23)
+ !
#
where $ is the volume-averaged density computed using Equation 17.14 (p. 480). Equation 17.23 (p. 483)
shows that the surface tension source term for a cell is proportional to the average density in the cell.
In the CSS method, the surface stress tensor due to surface tension is represented as
% =& ' −( ⊗ (
ur
( (17.24)
ur
) = ∇* (17.25)
ur
+
+ = ur (17.26)
+
where,
, = unit tensor
- = surface tension coefficient
⊗ = tensor product of the two vectors: the original normal and the transformed
normal
. = volume fraction
ur
/ = volume fraction gradient
∇2 ⊗ ∇2
0 =1 ∇2 3 − (17.27)
∇2
The surface tension force is represented as
4677 = ∇ 5 (17.28)
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 483
Multiphase Flows
In the CSF method, the surface tension force is represented in a nonconservative manner as follows:
= ∇ (17.29)
where k is the curvature. This expression is valid only for constant surface tension.
For variable surface tension, the CSF formulation requires you to model an additional term in the tan-
gential direction to the interface based on the surface tension gradient.
In the CSS method, surface tension force is represented in a conservative manner as follows:
∇ ⊗ ∇
= ∇ ∇
− (17.30)
∇
The CSS method does not require any explicit calculation for the curvature. Therefore, It performs more
physically in under-resolved regions, such as sharp corners.
The CSS method does not require any additional terms for modeling variable surface tension due to its
conservative formulation.
To include the effects of surface tension in your model, refer to Including Surface Tension and Adhesion
Effects in the User’s Guide.
If " # is the contact angle at the wall, then the surface normal at the live cell next to the wall is
$ɵ = $ɵ ' % ' + &ɵ' %' (17.33)
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
484 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
where ɵ and ɵ are the unit vectors normal and tangential to the wall, respectively. The combination
of this contact angle with the normally calculated surface normal one cell away from the wall determine
the local curvature of the surface, and this curvature is used to adjust the body force term in the surface
tension calculation.
To include wall adhesion in your model, refer to Including Surface Tension and Adhesion Effects in the
User's Guide.
Therefore, if is the contact angle at the porous jump, then the surface normal at the neighboring
cell to the porous jump is
ɵ = ɵ + ɵ (17.34)
where
ɵ and ɵ
are the unit vectors normal and tangential to the porous jump, respectively.
To include jump adhesion in your model, refer to Steps for Setting Boundary Conditions in the User's
Guide.
ANSYS Fluent provides two methods of jump adhesion treatment at the porous jump boundary:
The constrained two-sided adhesion treatment option imposes constraints on the adhesion
treatment. Here, the contact angle treatment will be applied to only the side(s) of the porous
jump that is(are) adjacent to the non-porous fluid zones. Hence, the contact angle treatment
will not be applied to the side(s) of the porous jump that is(are) adjacent to porous media zones.
If the constrained two-sided adhesion treatment is disabled, the contact angle treatment will be
applied to all sides of the porous jump.
Note
ANSYS Fluent allows you to use forced two-sided contact angle treatment for fluid zones without
any imposed constraints. Refer to Steps for Setting Boundary Conditions in the User’s Guide to
learn how to apply this option.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 485
Multiphase Flows
Flow is generally governed by the forces of gravity and inertia. This feature is mostly applicable to
marine applications and the analysis of flows through drainage systems.
Open channel flows are characterized by the dimensionless Froude Number, which is defined as the
ratio of inertia force and hydrostatic force.
= (17.35)
where is the velocity magnitude, is gravity, and is a length scale, in this case, the distance from
the bottom of the channel to the free surface. The denominator in Equation 17.35 (p. 486) is the
propagation speed of the wave. The wave speed as seen by the fixed observer is defined as
= ±
(17.36)
Based on the Froude number, open channel flows can be classified in the following three categories:
• When
< , that is, < (therefore < 0 or > 0), the flow is known to be subcritical where dis-
turbances can travel upstream as well as downstream. In this case, downstream conditions might affect
the flow upstream.
• When = (therefore = 0), the flow is known to be critical, where upstream propagating waves remain
stationary. In this case, the character of the flow changes.
• When > , that is, > (therefore > 0), the flow is known to be supercritical where disturbances
cannot travel upstream. In this case, downstream conditions do not affect the flow upstream.
• pressure inlet
r r
where + and , are the position vectors of the face centroid and any point on the free surface, respect-
r
ively, Here, free surface is assumed to be horizontal and normal to the direction of gravity. - is the
r
gravity vector, . is the gravity magnitude, / is the unit vector of gravity, 0 is the velocity magnitude,
1 is the density of the mixture in the cell, and 2 3 is the reference density.
From this, the dynamic pressure 4 is
6
5= 7 8 (17.38)
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
486 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
r r r
= − ⋅ − (17.39)
where the distance from the free surface to the reference position, , is
r
= − ⋅ (17.41)
For subcritical inlet flows (Fr < 1), ANSYS Fluent reconstructs the volume fraction values on the boundary
by using the values from the neighboring cells. This can be accomplished using the following procedure:
• Calculate the node values of volume fraction at the boundary using the cell values.
• Calculate the volume fraction at the each face of boundary using the interpolated node values.
For supercritical inlet flows (Fr > 1), the volume fraction value on the boundary can be calculated using
the fixed height of the free surface from the bottom.
For subcritical outlet flows (Fr <1), if there are only two phases, then the pressure is taken from the
pressure profile specified over the boundary, otherwise the pressure is taken from the neighboring cell.
For supercritical flows (Fr > 1), the pressure is always taken from the neighboring cell.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 487
Multiphase Flows
• You can only use single outflow boundaries at the outlet, which is achieved by setting the flow rate
weighting to 1. In other words, outflow splitting is not permitted in open channel flows with outflow
boundaries.
• There should be an initial flow field in the simulation to avoid convergence issues due to flow reversal at
the outflow, which will result in an unreliable solution.
• An outflow boundary condition can only be used with mass flow inlets. It is not compatible with pressure
inlets and pressure outlets. For example, if you choose the inlet as pressure-inlet, then you can only use
pressure-outlet at the outlet. If you choose the inlet as mass-flow-inlet, then you can use either outflow
or pressure-outlet boundary conditions at the outlet. Note that this only holds true for open channel
flow.
• Note that the outflow boundary condition assumes that flow is fully developed in the direction perpen-
dicular to the outflow boundary surface. Therefore, such surfaces should be placed accordingly.
= − + (17.43)
where
= vertical direction along gravity
= flow direction
= momentum sink term in the direction
= linear damping resistance (1/s) (default value is 10)
= quadratic damping resistance (1/m) (default value is 10)
= velocity along the direction
= distance from the free surface level
= distance along the flow direction
= damping function in the direction
= damping function in the direction
The scaling factors in the and directions are defined by Equation 17.44 (p. 488) and Equa-
tion 17.45 (p. 489), respectively:
− !
= (17.44)
" − !
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
488 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
−
= (17.45)
−
In Equation 17.44 (p. 488), and are the start and end points of the damping zone in the direction.
In Equation 17.45 (p. 489), and are the free surface and bottom level along the direction.
Note
Numerical beach treatment in ANSYS Fluent uses linear damping in the direction and
quadratic damping in the direction.
Note
This option is available with Open Channel Flow (p. 485) and Open Channel Wave Boundary
Conditions (p. 489).
To include numerical beach in your simulation, see Numerical Beach Treatment for Open Channels
ANSYS Fluent provides the following wave theories for incoming surface gravity waves through velocity
inlet boundary conditions:
• First order Airy wave theory is applied to small amplitude waves in shallow to deep liquid depth
ranges, and is linear in nature.
• Higher order Stokes wave theories are applied to finite amplitude waves in intermediate to deep liquid
depth ranges, and are nonlinear in nature.
• Higher order Cnoidal/Solitary wave theories are applied to finite amplitude waves in shallow depth
ranges, and are nonlinear in nature.
Short gravity wave expressions for each wave theory are based on infinite liquid height, whereas shallow
or intermediate wave expressions are based on finite liquid height.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 489
Multiphase Flows
where is the wave amplitude, is the wave amplitude at the trough, and is the wave amplitude
at the crest. For linear wave theory, = and for nonlinear wave theory, ≠
.
where is the reference wave propagation direction, is the direction opposite to gravity and is the
direction normal to and . The wave numbers in the and directions are defined by Equa-
tion 17.51 (p. 490) and Equation 17.52 (p. 490), respectively:
= (17.51)
!#=! " (17.52)
$ is the wave heading angle, which is defined as the angle between the wave front and reference wave
propagation direction, in the plane of % and &.
where ; , < , and = are the velocity components of the surface gravity wave in the > , ?, and @ directions,
respectively.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
490 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
and are the space coordinates in the and directions, respectively, is the phase difference, and
is the time.
where is the liquid height, is the wave number, and is the gravity magnitude.
The velocity components for the incident wave boundary condition can be described in terms of shal-
low/intermediate waves and short gravity waves.
where 7 is the height from the free surface level in the direction 8, which is opposite to that of gravity.
For more information on how to use and set up this model, refer to Modeling Open Channel Wave
Boundary Conditions in the User’s Guide.
The generalized expression for the associated velocity potential for shallow/intermediate waves is
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 491
Multiphase Flows
+
+
+
+
+
=
+
+ (17.65)
+
and for short gravity waves, the velocity potential is
= (17.66)
$ %
where is the wave speed, is the gravity magnitude, , , and & '( ) *+
are functions of wave length,-.
and liquid height for shallow/intermediate waves and constant values for short gravity waves. Velocity
components for surface gravity waves are derived from the velocity potential function.
/ = ∂∂ 01 2 (17.68)
3 = ∂∂ 45 6 (17.69)
7 = ∂∂89 (17.70)
Refer to Lin's book for details on the numerical expressions [254] (p. 743).
Note
For simplicity, the higher order terms, which are functions of relative depth, have been
omitted from the numerical details below. Refer to the work of John D. Fenton [116] (p. 735)
for detailed numerical expressions.
:
The elliptic function parameter, , is calculated by solving the following nonlinear equation:
;= = > ? + ?@A<BC ⋅DCEBC ⋅FBC>G (17.71)
< <
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
492 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
Tough height from the bottom, , is derived from the following relationship:
= − +
⋅
⋅
(17.72)
where T U is the translational distance from reference frame origin in the V direction.
Velocity components for the fifth order wave theories are expressed as:
h d d− g ie d
[Z bc i
W = X − YZ bc − ∑
d = g
∑ \ +Z
e = j Z bc f = j
i f ∑
X] ^ _ ` def a (17.78)
| x x− { }y x
on vw }
k = l − mn vw − ∑
x = {
∑ p +n
y = ~ n vw z = ~
} z ∑
lq r s t xyz u (17.79)
=
− +
∑
∑ ∑
+ (17.80)
−
+
= = =
where are the numerical coefficients mentioned in the reference [116] (p. 735).
Note
Solitary wave theory expressions are derived by assuming that the waves have infinite wave
length. Based on this assumption we get:
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 493
Multiphase Flows
=
Wave Height
Wave Amplitude
Liquid Height
Trough Height
Wave Length
Wave Heading Angle
Wave Number
Wave Number in the direc-
tion
Wave Number in the direc-
tion
Wave Celerity
Wave Frequency
Effective Wave Frequency
Elliptical Function Parameter
Complete Elliptical Integral
of the First Kind
Complete Elliptical Integral
of the Second Kind
!" # $ , %& ' ( , )* + , Jacobian Elliptic Functions
. Spatial coordinate in the -
direction
0 Spatial coordinate in the /
direction
2 Spatial coordinate in the 1
direction
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
494 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
Symbol Description
Translational distance from
reference frame origin in the
direction
Velocity Potential
ur Averaged velocity of flow
current
Velocity components for sur-
face gravity waves in the ,
, and
directions, respect-
ively.
• Mandatory Check for Complete Wave Regime within Wave Breaking Limit
The wave height to liquid depth ratio (relative depth) within the wave breaking limit is defined
as:
=
(17.81)
=
(17.82)
%&'( !"#! $
The wave height to wave length depth ratio ) * (wave steepness) within the breaking limit is defined
as:
+ =
, (17.83)
6789 -./01/-2345
: =
; (17.84)
CDEF <=>?@A?>B
For this check, the wave type is represented with the appropriate wave theory in the following
manner:
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 495
Multiphase Flows
Checks for wave theories between second to fourth order are performed between linear and fifth
order Stokes wave.
The liquid height to wave length ratio for short gravity waves is defined as:
= (17.85)
For Stokes wave in shallow regime the ratio is defined as:
= (17.86)
For shallow waves, the ratio is defined as:
= (17.87)
– Wave Steepness Check
The wave height to wave length ratio for linear waves is defined as:
=
(17.88)
For Stokes wave in shallow regime, the ratio is defined as:
=
(17.89)
For shallow waves, the ratio is defined as:
! =
$
" # (17.90)
%&' "
• Relative Depth Check
The wave height to liquid depth ratio ( ) for a linear wave is defined as:
* =
+ (17.91)
,-.
For Stokes wave in shallow regime the ratio is defined as:
/ =
0 (17.92)
123
For shallow waves, the ratio is defined as:
4 =
5 (17.93)
678
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
496 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
• Interference: Superposition of waves of the same frequency and wave heights, travelling in the same dir-
ection. Constructive interference occurs in cases of waves travelling in the same phase, while destructive
interference occurs in cases of waves travelling in opposite phases.
• Beats/Wave Group: Superposition of waves of same wave heights travelling in the same direction with
nearly equal frequencies. The beats are generated by increase/decrease in the resultant frequency of the
waves over time.
For marine applications, this concept of wave superposition is known as a Wave Group. In a wave
group, packets (group) of waves move with a group velocity that is slower than the phase speed of
each individual wave within the packet.
• Stationary/Standing Waves: Superposition of identical waves travelling in opposite directions. This super-
position forms a stationary wave where each particle executes simple harmonic motion with the same
frequency but different amplitudes.
• Irregular Waves: Superposition of waves with different wave heights, frequencies, phase differences, and
direction of propagation. Irregular sea waves are quite common in marine applications, and can be modeled
by superimposing multiple waves.
Note
The superposition principle is only valid for linear and small-amplitude waves. Superposition
of finite amplitude waves may be approximate or invalid because of their nonlinear behavior
and dependency of the wave dispersion on wave height.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 497
Multiphase Flows
Important
The coupled level-set and VOF model is specifically designed for two-phase flows, where no
mass transfer is involved and is applied to transient flow problems only. The mesh should
be restricted to quadrilateral, triangular or a combination of both for 2D cases and restricted
to hexahedral, tetrahedral or a combination of both for 3D cases.
To learn how to use this model, refer to Including Coupled Level Set with the VOF Model
17.3.13.1. Theory
The level-set function is defined as a signed distance to the interface. Accordingly, the interface is the
zero level-set, and can be expressed as = = in a two-phase flow system:
+ ∈
= ∈ (17.98)
∈
where is the distance from the interface.
The normal and curvature of the interface, which is needed in the computation of the surface tension
force, can be estimated as
uv ∇
=
∇
=
(17.99)
∇
=∇ ⋅
∇ =
(17.100)
The evolution of the level-set function can be given in a similar fashion as to the VOF model:
∂ uv
+∇⋅ = (17.101)
∂
uv
Where is the underlying velocity field.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
498 of ANSYS, Inc. and its subsidiaries and affiliates.
Volume of Fluid (VOF) Model Theory
uv
∂
= − ∇ + ∇ ⋅ ∇ + ∇
− ∇ +
uv uv uv uv uv
+∇⋅ (17.102)
∂
+
= if < and = (where is the grid spacing), otherwise = . is the
surface tension coefficient.
The concept of piecewise linear interface construction (PLIC) is also employed to construct the interface-
front. The procedure for the interface–front reconstruction can be briefly described as follows and as
shown in Figure 17.3: Schematic View of the Interface Cut Through the Front Cell (p. 499):
1. Locate the interface front cells, where the sign(!) is alternating or the value of the volume fraction
is between 0 and 1, that is, a partially filled cell.
2. Calculate the normal of the interface segment in each front cell from the level-set function gradients.
3. Position the cut-through, making sure at least one corner of the cell is occupied by the designated
phase in relation to the neighboring cells.
4. Find the intersection between the cell centerline normal to the interface and the interface so that
the VOF is satisfied.
5. Find the intersection points between the interface line and the cell boundaries; these intersection
points are designated as front points.
Figure 17.3: Schematic View of the Interface Cut Through the Front Cell
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
of ANSYS, Inc. and its subsidiaries and affiliates. 499
Multiphase Flows
Once the interface front is reconstructed, the procedure for the minimization of the distance from a
given point to the interface can begin as follows:
1. Calculate the distance of the given point in the domain to each cut-segment of the front cell. The
method for the distance calculation is as follows:
a. If the normal line starting from the given point to the interface intersects within the cut-segment,
then the calculated distance will be taken as the distance to the interface.
b. If the intersection point is beyond the end points of the cut-segment, the shortest distance from the
given point to the end points of the cut-segment will be taken as the distance to the interface cut-
segment, as shown in Figure 17.4: Distance to the Interface Segment (p. 500).
2. Minimize all possible distances from the given point to all front cut-segments, so as to represent the
distance from the given point to the interface. Thus, the values of these distances will be used to re-ini-
tialize the level-set function.
17.3.13.2. Limitations
The current implementation of the model is only suitable for two-phase flow regime, where two fluids
are not interpenetrating. The level-set model can only be used when the VOF model is activated. Note
that no mass transfer is permitted.
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
500 of ANSYS, Inc. and its subsidiaries and affiliates.