The document contains architectural plans and drawings for a proposed 2-storey residential building in Cebu City, Philippines.

The plans and drawings included are: site plan, floor plans, elevations, section, details.

Structural details shown include reinforced concrete column splices, moment frame connections, reinforcement schedules.

REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS


10900 AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
CECU CITY

2 3 RECOMMENDING APPROVAL

HEAD ARCHITECTURAL DATE


SECTION
APPROVED:

BUILDING OFFICIAL DATE

LOT 8, BLOCK-1

13400

13400
AREA = 146.06 Sq.m. LINE & GRADE

HEAD DATE

LAND USE & ZONING

1 4

HEAD DATE

10900

B LOT PLAN
A PERSPECTIVE AR-01 SCALE : 1:100
ARCHITECTURAL
AR-01 SCALE : 1:NTS

A B C D HEAD DATE
8900

3100 4400 1400 2000

STRUCTURAL

2000
CONCRETE LEDGE CONCRETE LEDGE CONCRETE LEDGE

1
THIS SITE HEAD DATE

CONCRETE LEDGE

3700
ROOF DECK

5950
2
MECHANICAL

13400
CONCRETE CANOPY

CONCRETE LEDGE

4700
HEAD DATE

5500

800
SANITARY

3000

3000
HEAD DATE

3000 5900 2000

10900

D VICINITY MAP
AR-01 SCALE : NTS C SITE DEVELOPMENT PLAN ELECTRICAL
AR-01 SCALE : 1:100

FOR PRESENTATION
HEAD DATE

SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or - PERSPECTIVE DRAWING
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER
- VICINITY MAP
- SITE DEVELOPMENTAL PLAN
DRAFTSMAN
A-100
REG. NO.: -
to make copies of said documents for use - LOT PLAN
DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
JUN-NINE BINAGATAN
R 0
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
CECU CITY

A B C D A B C D
A B A C D A
RECOMMENDING APPROVAL
8900
8900 8900
3100 4400 1400 2000
3100 4400 1400 2000 3100 4400 1400 2000
HEAD ARCHITECTURAL DATE
1100 3300 1400 3000 SECTION
APPROVED:

2000
2000
2000
CONCRETE LEDGE CONCRETE LEDGE CONCRETE LEDGE

1000
2400
1000

BUILDING OFFICIAL DATE


W02 W03 D04
1
W02 W03 W02
1
1

TABLE

TABLE
2000

2450

CONCRETE LEDGE
W02

CLOSET

CLOSET

3700
GUESS ROOM

3700
+0.35m D02

3700
D03

W02
DINING AREA
+0.35m A MASTER D03 ROOF DECK
A BEDROOM

W02
BEDROOM

5950
KITCHEN AREA

5950

D02
5950

1900

D02
1450
+0.35m

2 2
2 D03

1200
570
W01 D02 PANTRY

13400
13400
BALCONY

13400
DOWN
13400

2000
BALCONY LINE W02 D02 16 CONCRETE CANOPY
2000

SERVICE AREA 15
15
+0.25m BALCONY

ARCHITECTURAL FINS
14
ARCHITECTURAL FINS

14

CONCRETE LEDGE
13
13

4700
UP 12

W04

4700
12

W04

4700
01
LOW WALL
11 01 LIVING AREA 11
02
10 02 +0.35m 10
OPEN TO
09 03
09 03

08 04
08 04 BELOW

2500
07 05
2500

07 05
06
06
D03

STORAGE
W05 W04
BELOW D01 W02
3 3

5500
3

5500

800
5500

GARAGE

800
W06 W06 +0.25m GREEN CONCRETE LEDGE
+0.10m

1800
CANOPY ABOVE

1000

3000

3000
3000
3000

3000

+0.10m

3000 5900 2000


3000 5900 2000 3000 5900 2000
10900
10900 10900

C ROOF PLAN
A GROUND FLOOR PLAN B SECOND FLOOR PLAN AR-01 SCALE : 1:100
AR-01 SCALE : 1:100 AR-01 SCALE : 1:100

A B C D 1 2 3 D C B A A B C
8900 950 8450
8900 7400
3100 4300 1500 3750 4700
1500 4300 3100 3100 4300

TOP OF PARAPET TOP OF PARAPET TOP OF PARAPET


TOP OF PARAPET
PLAIN CEMENT
1400

1400

1400
1400
PAINTED FINISH SEE TRUSS
DETAIL
TOP OF ROOF BEAM TOP OF ROOF BEAM TOP OF ROOF BEAM
TOP OF ROOF BEAM

FIREWALL
2800

2800

2800
2800
PLAIN CEMENT PAINTED FINISH
7200

7200

PLAIN CEMENT

7200
MASTER

7200
PLAIN CEMENT
PAINTED FINISH BEDROOM
PAINTED FINISH BEDROOM
SECOND FLOOR LINE SECOND FLOOR LINE SECOND FLOOR LINE
SECOND FLOOR LINE

FIREWALL
3000

3000

3000
3000
STONE TILE FINISH PLAIN CEMENT PAINTED FINISH
PLAIN CEMENT DINING AREA
PAINTED FINISH
GROUND FLOOR LINE GROUND FLOOR LINE GROUND FLOOR LINE
GROUND FLOOR LINE
350

350

350
350
NGL
NGL NGL
NGL
100

100

100
A FRONT ELEVATION A LEFT-SIDE ELEVATION A REAR ELEVATION A SECTION THRU A
AR-01 SCALE : 1:100 AR-01 SCALE : 1:100 AR-01 SCALE : 1:100 AR-01 SCALE : 1:100

FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or - GROUND FLOOR
sealed, as instruments of service, are the
- SECOND FLOOR JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER
- ROOF PLAN
- FRONT ELEVATION DRAFTSMAN
A-200
REG. NO.: - DATE : - - LEFT-SIDE ELEVATION
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
- REAR ELEVATION
- SECTION THRU-A
JUN-NINE BINAGATAN
R 0
REPUBLIC OF THE PHILIPPINES
3 2 1 DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
8450 950 OFFICE OF THE BUILDING OFFICIAL
4700 3750
SCHEDULE OF DOORS AND WINDOWS CECU CITY

TOP OF PARAPET RECOMMENDING APPROVAL

W01 W02 W03 W04 W05 W06


1400

HEAD ARCHITECTURAL DATE


TOP OF ROOF BEAM SECTION
APPROVED:

250

250

250

250
F F F F F F F F F
2800

BUILDING OFFICIAL DATE

600
7200

PLAIN CEMENT
PAINTED FINISH

1450
SECOND FLOOR LINE

1200

1200

1200
F S S S

2100

2100
3000

F F F F F F

1500
GROUND FLOOR LINE
350

900

900

900
NGL
100

A RIGHT-SIDE ELEVATION FIXED GLASS SLIDING GLASS


JEALOUSY W/ ALUMINUM FRAME
FIXED GLASS WINDOW W/ FIXED GLASS WINDOW W/ FIXED GLASS WINDOW W/
AR-01 SCALE : 1:100 WINDOW WINDOW W/ ALUMINUM FRAME ALUMINUM FRAME ALUMINUM FRAME ALUMINUM FRAME

D01 D02 D03 D04


800 700 2400
900 600 600 600 600
3 2 1
8450 950

4700 3750

TOP OF PARAPET
1400

SEE TRUSS F S S F

2100

2100

2100

2100
DETAIL
TOP OF ROOF BEAM
2800

BEDROOM
7200

SECOND FLOOR LINE

PANEL DOOR PANEL DOOR FLUSH DOOR SLIDING GLASS DOOR W/


ALUMINUM FRAME
KITCHEN
3000

AREA
DINING AREA
LIVING AREA
GROUND FLOOR LINE
350

NGL
100

A SECTION THRU B
AR-01 SCALE : 1:100

FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or - SCHEDULE OF DOORS & WINDOWS
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER
- RIGHT-SIDE ELEVATION
- SECTION THRU-B
DRAFTSMAN
A-300
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
JUN-NINE BINAGATAN
R 0
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
A B C D AND HIGHWAYS

GENERAL NOTES: 3100


8900

4400 1400 2000


OFFICE OF THE BUILDING OFFICIAL
CECU CITY

1. ALL ELECTRICAL WORKS ANG INSTALLATION SHALL BE DONE RECOMMENDING APPROVAL

2000
IN ACCORDANCE WITH THE PROVISION OF THE LATEST CONCRETE LEDGE CONCRETE LEDGE CONCRETE LEDGE
HEAD ELECTRICAL
SECTION
DATE

APPROVED EDITION OF PHILIPPINE ELECTRICAL RULES 1 APPROVED:

AND REGULATION OF THE NATIONAL AUTHORITIES CONCERN

CONCRETE LEDGE
BUILDING OFFICIAL DATE

3700
IN THE INFORCEMENT OF THE ELECTRICAL LAWS AND ORDINACE

5950
/ 60 HZ
2. SERVICE OF THE BUILDING SHALL BE 220V, 10 O.,
2
3. ALL MATERIALS TO BE USE SHALL BE NEW AND APPROVED

13400
TYPE FOR BOTH LOCATIONS AND SREVICES INTENTED
CONCRETE CANOPY

CONCRETE LEDGE

4700
4. ALL ELECTRICAL INSTALLATION HEREIN BE DONE UNDER
DIRECT SUPERVISION OF A DULY LICENSE RME, REE AND PEE
5. ALL SWITCHES SHALL BE LOCATED 1.50 M FROM THE FINISHED 3

5500

800
CONCRETE LEDGE

FLOOR LINE & 0.30 FOR ALL CONVENIENCE OUTLETS

3000

3000
6. ELECTRICAL WIRES EMBEDDED ON CONCRETE SHALL BE CONCEALED
ON RIGID STEEL CONDUIT OR ELECTRICAL PVC PIPES
3000 5900 2000

10900

KEY SYMBOLS: SITE DEVELOPMENT PLAN


POWER SOURCE

SCALE 1 : NTS
CIRCUIT LINE

M KWHM

M KILOWATT METER

POWER SOURCE
60 HZ AMPERES MAIN CIRCUIT BREAKER
2 - 10mm 2 THHN MAIN WIRE BREAKER THIS SITE

GROUND C1 C2

15 A 15 A
SWITCH LINE C3 C4

20 A 20 A
PANEL BOARD C5 C6

PB 20 A 20 A
CONVENIENCE OUTLET C7 C8

30 A 30 A
WEATHERPROOF CONVENIENCE
OUTLET
SPARE SPARE
CHANDELIER LAMP

PIN LIGHTS

COMPACT FLOURESCENT LAMP


GROUND
CIRCULAR LAMP

S 1 (a)
SINGLE GANG SWITCH

S 2 (b) DOUBLE GANG SWITCH SINGLE LINE DIAGRAM VICINITY MAP


S THREE GANG SWITCH SCALE 1 : NTS SCALE 1 : NTS
FOR PRESENTATION
3 (c)

SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or -AS SHOWN
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER DRAFTSMAN
E-100
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
UZZIEL CARLOM
R 0
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
A B C D A B C D AND HIGHWAYS
A B C D OFFICE OF THE BUILDING OFFICIAL
8900
8900
8900
3100 4400 1400 2000 CECU CITY
3100 4400 1400 2000
3100 4400 1400 2000
1100 3300
1400 3000
1100 3300
RECOMMENDING APPROVAL

2000
2000
HEAD ELECTRICAL DATE

2000
2400

1000
SECTION

1000
2400
1000

W02 W03 D04


18w
18w
1 1 APPROVED:
1

2000
32w

W02
18w
2000

C1 32w 32w

2450
32w C2
18w BUILDING OFFICIAL DATE

3700
D02 D03

3700
b c

3700
Sb
c c 1hp

W02
Sc

A B C D
Sc
Sb
Sc
C6

5950
b

1900
c
Sc

5950
32w
5950

32w 18w 32w


1900

1450
32w 8900
18w

2 2 D03 3100 4400 1400 2000


2 18w
Sa,Sb
18w 18w W01 D02

1200

12900

13400
570
a
1400 3000

12900
Sa
12900

13400

2000
18w

2000
2000

32w a
32w
22w
UP

CONCRETE LEDGE

2000
18w 18w b

W04

4700
UP

4700
50w

W04

4700

1000
Sa

C4 W02 W03 W02


32w
32w
RISER 1 1hp

2500
2500
a
RISER
2500

22w STORAGE
BELOW C7
32w STORAGE C3 1hp

D03
BELOW PB

2450
PB
32w D01 W02

5000
3
18w b

5000
3
5000

3700
Sb
C8
3 22w GREEN

W02
22w

800
18w 18w 18w
18w
GREEN 22w
D03
CONCRETE LEDGE

1800
CANOPY ABOVE

2500

5950
CANOPY ABOVE

1000

D02
3000
2500

D02
1450
3000
3000 2

1200
570
12900
3000 4500

2000
4500 W02 D02
3000 4500 C5
2000
3000 2000
2000

CONCRETE LEDGE
9500

W04

4700
9500
9500

2500
GROUND FLOOR LIGHTING LAYOUT SECOND FLOOR LIGHTING LAYOUT GROUND FLOOR POWER LAYOUT W02 W02 W02 W02

5000
3

800
CONCRETE LEDGE

SCALE 1 : 100M SCALE 1 : 100M SCALE 1 : 100M

1800
1000

3000
SCHEDULE OF LOADS 3000
4500

2000

No. of SWITCHES LIGHTS AMPERE SIZE OF 9500


CKT No. DISCRIPTION PHASE VOLTS COMPUTATION AMPERE
OUTLETS S1(a) S2(b) S3(c) 3-way 50w 32w 22w 18w
PER CKT WIRE
CEILING LINE
(6x32)+(10x18)
C1 LIGHTS 1 3 1 6 10 SINGLE 220 V 15 AMP 2

SECOND FLOOR POWER LAYOUT


x1.25/220 2.11 3.50mm THW

(1x50)+(8x32)+(5x22)+(7x18)
C2 LIGHTS 2 3 3 1 8 5 7 x1.25/220 3.07 15 AMP 4.00mm2 THW
C2
7 X 220 X 1.25/220
8.25
SCALE 1 : 100M
C3 OUTLETS 7 20 AMP 5.50mm2 THW

C4 OUTLETS 3 3 X 220 X 1.25/220 3.75 20 AMP 5.50mm2 THW


C7 C5 C8
C5 OUTLETS 6 6 X 220 X 1.25/220 7.5 20 AMP 5.50mm 2 THW

C6 KITCHEN 1 1x(1x746) x1.25/220 4.23 20 AMP 5.50mm THW


2

SF
C7 AIRCON 1 1x(1x746) x1.25/220 4.23 30 AMP 6.00mm THW 2

C8 AIRCON 1 1x(1x746) x1.25/220 4.23 30 AMP 6.00mm2 THW

C1
SPARE
C4 C6 C3

TOTAL 19 3 6 4 1 14 5 17 37.37

MAIN BREAKER DESIGN


GF PB
IS = 2.0 X [HIGHEST CURRENT OF LOAD] + TOTAL OF LOAD] [DEMAND FACTOR 100%]
IS = 2.0 X [8.25] + 37.37 (100%)
IS = 53.87 AMPERES USE: 60HZ AMPERES MAIN CIRCUIT BREAKER
RISER DIAGRAM
MAIN WIRE DESIGN
SCALE 1 : NTS
IC = [0.25 X HIGHEST CURRENT OF LOAD] + TOTAL OF LOAD] [DEMAND FACTOR 1.00]
IC = [0.25 X 8.25] + 37.37 (1.00)
IS = 39.4325 AMPERES USE: 2-10mm THHN MAIN WIRE BREAKER
2 FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or -AS SHOWN
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER DRAFTSMAN
E-200
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
UZZIEL CARLOM
R 0
REPUBLIC OF THE PHILIPPINES
A B C D DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
8900
OFFICE OF THE BUILDING OFFICIAL
3100 4400 1400 2000 CECU CITY

GENERAL NOTES : LEGEND : RECOMMENDING APPROVAL


1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF THE
WATER SUPPLY SYSTEM

2000
REVISED NATIONAL PLUMBING CODE OF THE PHILIPPINES. THE NATIONAL BUILDING CODE & THE RULES
CONCRETE LEDGE CONCRETE LEDGE CONCRETE LEDGE HEAD ARCHITECTURAL DATE
AND REGULATIONS OF THE CITY. SECTION
PWLG POTABLE WATER LINE (GRAVITY)
1 APPROVED:
2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS, THE ENGINEER CWR COLD WATER RISER
SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN.
CWD COLD WATER DOWNFEED

CONCRETE LEDGE
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY RELOCATIONS REQUIRED FOR PROPER BUILDING OFFICIAL DATE

3700
GV GATE VALVE
EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
CV CHECK VALVE

5950
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND INVERT HB HOSE BIBB / FAUCET
ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.
M WM WATER METER 2
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS OTHERWISE SPECIFIED.

13400
CONCRETE CANOPY
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS.

CONCRETE LEDGE

4700
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATE THE WORKS WITH THE
SEWER LINE EFFLUENT DISPOSAL POINT AND WATER LINE SERVICE CONNECTING POINT UNLESS
OTHERWISE SPECIFIED.

8. ALL PIPES SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METER UNLESS OTHERWISE SPECIFIED. STORM DRAINAGE SYSTEM
3

5500

800
CONCRETE LEDGE
DP DRAIN PIPE
DS DOWNSPOUT
MATERIAL SPECIFICATIONS :

3000

3000
DD DECK DRAIN
WATER LINES SHALL BE POLYPROPYLENE(PPR) PIPES & FITTINGS PN-20, CB CB CATCH BASIN
CONFORMING TO ASTM F1281, DVGW DW 8501 AS2120 STANDARDS.
JOINTING SHALL BE BY SOCKET FUSION OR ELECTRO FUSION. AD/CB AD/CB AREA DRAIN / CATCH BASIN
"BELDEN" BRAND PN-20 OR APPROVED EQUAL. 3000 5900 2000
DMH DMH DRAINAGE MANHOLE
10900
SEWER LINES & SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTING, SERIES 1000 / DP/WP DRAIN PIPE / WASTE PIPE
WASTE LINES CLASS II. CONFORMING TO ASTM D2564 STANDARDS. JOINTING SHALL
BE BY SOLVENT CEMENT. "EMERALD" BRAND OR APPROVED EQUAL. MH MANHOLE

VENT PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTING, SERIES 1000 /
RCP REINFORCED CONCRETE PIPE A SITE DEVELOPMENT PLAN
CLASS II. CONFORMING TO ASTM D2564 STANDARDS. JOINTING SHALL CDP CONCRETE DRAIN PIPE AR-01 SCALE : 1:100
BE BY SOLVENT CEMENT. "EMERALD" BRAND OR APPROVED EQUAL. OFP OVERFLOW PIPE

DOWNSPOUTS SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTING, SERIES 1000 /
CLASS II. CONFORMING TO ASTM D2564 STANDARDS. JOINTING SHALL
BE BY SOLVENT CEMENT. "EMERALD" BRAND OR APPROVED EQUAL.

STORM DRAINAGE LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTING, SERIES 1000 /
CLASS II. CONFORMING TO ASTM D2564 STANDARDS. JOINTING SHALL
BE BY SOLVENT CEMENT. "EMERALD" BRAND OR APPROVED EQUAL.
WASTE DISPOSAL SYSTEM
-FOR OUTSIDE BUILDING, CONCRETE DRAIN PIPE (CDP), TONGUE & GROOVE,
MORTAR JOINTS, REINFORCED FOR 300mmØ & LARGER. WP/SP WASTE PIPE / SOIL PIPE

GATE VALVE VP/VAC VENT PIPE / VENT ABOVE CEILING


75mmØ & LARGER, SHALL BE RISING STEM, IRON BODY WITH BRONZE TRIM,
FLANGED CONNECTION, MINIMUM OF 150 PSIG WORKING PRESSURE, 65mmØ
& SMALLER, SHALL BE RISING STEM, ALL BRONZE, FEMALE TRHEADED,MINIMUM OF
CCO/GCO CEILING CLEAN OUT / GROUND CLEAN OUT THIS SITE
150 PSIG WORKING PRESSURE. "CRAMER" BRAND OR APPROVED EQUAL. FCO/CO FLOOR CLEAN OUT / CLEAN OUT
SS/WS SOIL STACK / WASTE STACK
AAV AIR ADMITTANCE VALVE
SD/FD/SSD SHOWER DRAIN / FLOOR DRAIN / SLOP SINK DRAIN
DRAINS
VTW VENT THRU WALL
FLOOR / SHOWER DRAIN MODEL JPI- 106, "JAMAN" BRAND OR APPROVED EQUAL.
VTR VENT THRU ROOF
FLOOR CLEAN-OUT MODEL JPI- 137, "JAMAN" BRAND OR APPROVED EQUAL.
VSTR VENT STACK THRU ROOF
GROUND CLEAN-OUT MODEL JPI- 137, "JAMAN" BRAND OR APPROVED EQUAL.

GUTTER DRAIN MODEL JPI- 117, "JAMAN" BRAND OR APPROVED EQUAL.

WATER METER SIZE AS INDICATED ON THE PLANS, "E-JET" BRAND


OR AS APPROVED BY LWD FOR MAIN METER.

HOSE BIBBS 20mmØ STANDARD HOSE CONNECTION, MALE TAPERED


THREADS POLISHED CHROME PLATED.
PLUMBING FIXTURE
WC WATER CLOSET
CERTIFICATION : LAV LAVATORY

THIS IS TO CERTIFY THAT THERE IS NO ARTESIAN WELL WITHIN URI URINAL


25.00 METER RADIUS FROM THE PROPOSED SEPTIC TANK.
SH SHOWER HEAD

KSK KITCHEN SINK


AR. MARK BODIONGAN D VICINITY MAP
REGISTERED MASTER PLUMBER AR-01 SCALE : NTS

FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or - GENERAL NOTES
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER
- VICINITY MAP
- SITE DEVELOPMENTAL PLAN
DRAFTSMAN
P-100
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
REVO BITANCUR
R 0
REPUBLIC OF THE PHILIPPINES
A B C D A B C D A B C D DEPARTMENT OF PUBLIC WORKS
8900 AND HIGHWAYS
8900 8900
1,000 LTS. RWT 3100 4400 1400 2000 3100 4400 1400 2000
OFFICE OF THE BUILDING OFFICIAL
3100 4400 1400 2000
STAINLESS TANK 2"Ø VSTR CECU CITY
2"Ø VS 4"Ø DS 4"Ø DS
4"Ø DS 4"Ø DS 4"Ø DS 4"Ø DS 4"Ø DS/4"Ø DD 4"Ø DS/2-4"Ø GD 4"Ø DS/4"Ø GD
RUNNING ABOVE RWT

RECOMMENDING APPROVAL

2000
AD/CB

2000
2000
4"Ø DP 6"Ø PVC DP

1000
OFP

1000
CONCRETE LEDGE CONCRETE LEDGE CONCRETE LEDGE HEAD ARCHITECTURAL DATE

1 1 1 SECTION
APPROVED:

2000

2450

CONCRETE LEDGE
GUESS ROOM
BEDROOM

3700
+0.35m

3700
3700
DINING AREA BUILDING OFFICIAL DATE

4"Ø SP
+0.35m MASTER
2"Ø VAC BEDROOM
KITCHEN AREA

5950

4"Ø SP

5950
5950

1900

1450
GT
+0.35m 4"Ø SS
GCO

2 2 2

1200
570
6"Ø PVC DP
PANTRY

13400
4"Ø SS BALCONY

13400
DOMESTIC DOWN

13400
2000
16
BALCONY LINE
2000

CISTERN TANK

4"Ø SP
15 CONCRETE CANOPY
15
BALCONY

ARCHITECTURAL FINS
(SEE DETAIL) 14

ARCHITECTURAL FINS
14
13
13
UP 12

4700
12

4700
4700
01
11 01 LIVING AREA 11
02
10 02 +0.35m 10
OPEN TO
09 03
09 03

08 04
08 04 BELOW

2500
07 05
2500

07 05
4"Ø DP

06
06

D03
STORAGE
SEPTIC TANK BELOW
3 (SEE DETAIL) 3 3

5500
1925

1925

5500
5500

800
+0.25m GREEN

800
MH
3200

1800
1000

3000

3000

3000
3000

3000
GARAGE
1275

1125

+0.10m
MH MH +0.10m

AD/CB
4"Ø PVC DP
675 675
AD/CB
3000 5900 2000 3000 5900 2000 3000 5900 2000

TAP TO STP OR PUBLIC SEWER 10900 TAP TO PUBLIC EXISTING 10900 10900
(CONTRACTOR TO VERIFY DRAINAGE
LOCATION & I.E.) (CONTRACTOR TO VERIFY
LOCATION & I.E.)
GROUND FLOOR SECOND FLOOR ROOF PLAN
A DRAINAGE, WASTE & VENT PIPING LAYOUT A DRAINAGE, WASTE & VENT PIPING LAYOUT A DRAINAGE, WASTE & VENT PIPING LAYOUT
AR-01 SCALE : 1:100 AR-01 SCALE : 1:100 AR-01 SCALE : 1:100

A B C D A B C D A B C D
8900 8900 8900
3100 4400 1400 2000 3100 4400 1400 2000 3100 4400 1400 2000

32mmØ CWD-G 32mmØ CWD-G 32mmØ CWD-G


2000

2000
2000
1000

1000
CONCRETE LEDGE CONCRETE LEDGE CONCRETE LEDGE

1 GV 1 GV 1
2000

2450
APPROX. CAP.:

CONCRETE LEDGE
GUESS ROOM STAINLESS STEEL
+0.35m 1,500 LTS.
3700

POTABLE WATER TANK

3700
BEDROOM

3700
DINING AREA ELEVATE AT 1.5M FROM THE ROOF DECK
+0.35m
25mmØ CWL MASTER
GV
KITCHEN AREA BEDROOM ROOF DECK
5950

1900

5950
5950

+0.35m
1450

2 PANTRY
2 2

1200
570

32mmØ CWR
13400

DOMESTIC 40mmØ CWR 40mmØ CWR


TO WATER TANK ABOVE BALCONY

13400
13400

TO WATER TANK ABOVE DOWN TO WATER TANK ABOVE


GV BALCONY LINE
2000

CISTERN TANK
2000

16
15 CONCRETE CANOPY
15
(SEE DETAIL)
ARCHITECTURAL FINS

BALCONY

ARCHITECTURAL FINS
14
GV 14
13
13
FLV 12
UP
12
4700

LIVING AREA

4700
4700
11 01
11 01
10 02 +0.35m 10 02
09 03
09 03 OPEN TO
08 04
08 04 BELOW
2500

07 05
2500

07 05
(FROM MAIN WATER SUPPLY)

06
06
D03

STORAGE
BELOW
25mmØ CWL

3 3 3
5500

5500
5500

+0.25m GREEN

800
800
1800
1000
3000

3000

3000

3000
3000
GARAGE
+0.10m +0.10m
WM M
GV

3000 5900 2000 3000 5900 2000 3000 5900 2000

CONNECT TO MAIN WATER 10900 10900 10900


SUPPLY (CONTRACTOR TO
VERIFY LOCATION)

GROUND FLOOR SECOND FLOOR ROOF PLAN


A WATERLINE DISTRIBUTION PIPING LAYOUT A WATERLINE DISTRIBUTION PIPING LAYOUT A WATERLINE DISTRIBUTION PIPING LAYOUT
AR-01 SCALE : 1:100 AR-01 SCALE : 1:100 AR-01 SCALE : 1:100
FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or - GROUND FLOOR
sealed, as instruments of service, are the
- SECOND FLOOR JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER
- ROOF PLAN
DRAFTSMAN
P-200
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
REVO BITANCUR
R 0
REPUBLIC OF THE PHILIPPINES
3200
1800 DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
1975 1225
OFFICE OF THE BUILDING OFFICIAL
TOP OF PARAPET CECU CITY
1400

4"∅ SP RECOMMENDING APPROVAL


TOP OF ROOF BEAM LEACHING 4"∅ SP MH
2"Ø VAC INLET CHAMBER-2 OUTLET HEAD ARCHITECTURAL DATE
DIGESTIVE SECTION
2800

1500
CHAMBER DOMESTIC APPROVED:

2"Ø VS

1900
CISTERN TANK
7200

2"Ø VP
SECOND FLOOR LINE APPROX. CAP.: 5.0 m³
CCO LEACHING BUILDING OFFICIAL DATE
4"Ø SP
2"Ø VAC
R.C. COVER WITH
CHAMBER-1
3000

4"Ø SS
2"Ø VP 100 355.6 100
PLAN
GCO
GROUND FLOOR LINE
350

4"Ø SP GCO PLAN


NGL TO STP OR
4"Ø SP SEPTIC TANK 4"Ø SP PUBLIC SEWER

100
3:19
Habakkuk
the LORD GOD is my strenght.....

PS

SEE DETAIL 100


200

0
2000

0
300

4000
psi

bar
6000

8000
9000

3:19
Habakkuk
the LORD GOD is my strenght.....
400

630
600
500

the LORD GOD is my strenght..... 3:19


Habakkuk

3:19
Habakkuk
the LORD GOD is my strenght..... 3:19
Habakkuk
the LORD GOD is my strenght.....

3:19
Habakkuk
the LORD GOD is my strenght..... 3:19
Habakkuk
the LORD GOD is my strenght.....

3:19
Habakkuk
the LORD GOD is my strenght.....

3:19 3:19 3:19 3:19

Habakkuk
the LORD GOD is my strenght..... Habakkuk
the LORD GOD is my strenght..... Habakkuk
the LORD GOD is my strenght..... Habakkuk
the LORD GOD is my strenght.....

AIR SPACE AIR SPACE

Habakkuk

3:19
the LORD GOD is my strenght.....

3:19
Habakkuk
the LORD GOD is my strenght..... 3:19
Habakkuk
the LORD GOD is my strenght.....

300
3:19
Habakkuk
the LORD GOD is my strenght..... 3:19
Habakkuk
the LORD GOD is my strenght.....

3:19
Habakkuk
the LORD GOD is my strenght.....

kukkabaH
.....thgnerts ym si DOG DROL eht

91:3

355.6
WASTE & VENT
A SCHEMATIC DIAGRAM kukkabaH

91:3
the LORD GOD is my strenght.....

3:19
Habakkuk
the LORD GOD is my strenght.....
Habakkuk
the LORD GOD is my strenght.....

3:19

Habakkuk
the LORD GOD is my strenght.....

3:19
.....thgnerts ym si DOG DROL eht

91:3
kukkabaH

AR-01 SCALE : 1:100

91:3
kukkabaH
the LORD GOD is my strenght.....

100
1800
DIGESTIVE LEACHING
PLAN

1500
AIR SPACE

300
CHAMBER CHAMBER-1
TOP OF PARAPET PROVIDE ANGULAR
EDGINGS C R.C. COVER WITH
L
LIFTING HANDLE
1400

4"Ø DD 4"Ø DD 4"Ø GD 4"Ø GD


TOP OF ROOF BEAM

450mm MIN.(VARIES)
1500
SECTION
2800

4"Ø DS
7200

.....thgnerts ym si DOG DROL eht

91:3
kukkabaH
3:19
Habakkuk
the LORD GOD is my strenght.....

DS
A DETAIL OF SEPTIC TANK
the LORD GOD is my strenght..... 3:19
Habakkuk

kukkabaHthe LORD GOD is my strenght.....

91:3

SECOND FLOOR LINE FV DP


AR-01 SCALE : 1:30

50
4"Ø DS

4"Ø DS

200
SECTION
3000

80
RWT
GROUND FLOOR LINE
1,000 LTRS. D D A DETAIL OF CISTERN TANK SECTION
350

NGL 4"Ø DP AR-01 SCALE : 1:30


OVERFLOW PIPE TO NEAREST CB
FLOOR DRAIN
DECK DRAIN
"JAMAN" BRAND SQUARE STRAINER
"JAMAN" BRAND
DETAIL OF CATCH BASIN
OR APPROVED EQUAL
STORM DRAINAGE
A SCHEMATIC DIAGRAM D D

AR-01 SCALE : 1:100

PLAN PLAN

4"Ø DS
GV

APPROX. CAP.: 226.6MM 226.6MM


1,500 LTS. D D
TOP OF PARAPET
GV
WATERPROOFING
1400

WATERPROOFING MEMBRANE

4"Ø OVERFLOW PIPE


MEMBRANE
TOP OF ROOF BEAM FLOOR LEVEL
FLOOR LEVEL
32mmØ CWD-G

C
C

1,000 LTS. CAPACITY


2800

STAINLESS STEEL
32mmØ CWR
7200

GV 25mmØ CWL
RAINWATER TANK

50.8-101.6
50.8-101.6

SECOND FLOOR LINE (S.O.)

POWDER KIT. LAV. W.M.


ROOM SINK
3000

GV 20mmØ GV 20mmØ
GV 25mmØ GV 20mmØ WM GV JAMAN MODEL GROUND FLOOR LVL
(S.O.) (S.O.) M
DECK DRAIN
(S.O.) (S.O.) "JAMAN" BRAND
GROUND FLOOR LINE CONNECT TO OR APPROVED EQUAL
350

MAIN WATER
NGL SUPPLY
FLV
25mmØ
DOMESTIC SECTION SECTION
CISTERN TANK
(SEE DETAIL) TABLE OF DIMENSION
A RAINWATER TANK
TABLE OF DIMENSION AR-01 SCALE : 1:30
PIPE SIZE DIMENSION IN MM PIPE SIZE DIMENSION IN MM
IN IN
"A" C D "A" C D
WATERLINE DISTRIBUTION 50 38.1 101.6 50 38.1 101.6
A SCHEMATIC DIAGRAM 75
100
38.1
40.1
127.0
152.4
75 38.1 127.0

AR-01 SCALE : 1:100 150 50.8 177.8


100
150
40.1
50.8
152.4
177.8

DETAILOFDECK/GUTTERDRAIN DETAIL OF FLOOR DRAIN FOR PRESENTATION


SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or - DETAIL OF SEPTIC TANK
sealed, as instruments of service, are the JUN-NINE BINAGATAN
- - DETAIL OF CISTER TANK
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER
- RAINWATER TANK
- SCHEMATIC DIAGRAM DRAFTSMAN
P-300
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
REVO BITANCUR
R 0
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
GENERAL STRUCTURAL/CONSTRUCTION NOTES AND SPECIFICATIONS SEE CONSTRUCTION NOTES
DOWEL TO MATCH
CHB VERT. BARS
CECU CITY
FOR MASONRY WALL REIN- WHERE SLAB
FORCEMENTS (TYPICAL) DOWEL TO MATCH
DEPRESSION OCCURS RECOMMENDING APPROVAL
(A) GENERAL REQUIREMENTS FIN. FLR. LVL. CHB VERT. BARS
300
DOWEL BARS TO MATCH 300 (TYP.)

DIAMETER
VARIES

DOWELS
1. ALL STRUCTURAL MATERIALS AND WORK SHALL CONFORM TO THE REQUIREMENTS 6. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS: CHB VERT. BARS

30 BAR
(TYP.) HEAD STRUCTURAL DATE

DIAMETER
DOWELS
OF THE LATEST EDITION OF THE NATIONAL STRUCTURAL CODE OF THE PHILIPPINES

30 BAR
SECTION
FOOTINGS (CAST AGAINST & EXPOSED TO EARTH) . . . . . 75MM (3") N.G.L
(NSCP 2001).

DIAMETER
APPROVED:

DOWELS
30 BAR
WHERE CONCRETE IS EXPOSED TO
2. VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING FIN. FLR. LVL.
EARTH BUT POURED AGAINST FORMS . . . . . . . . . . . . . . . . 50MM (2")

600 (MIN.)
WORK. NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES.

250
40MM ( 1 1/2")

250
SLAB ON GRADE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUILDING OFFICIAL DATE
3. NOTES AND DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER THE GENERAL
NOTES AND TYPICAL DETAILS IN CASE OF CONFLICT. COLUMN TIES OR SPIRALS AND BEAM STIRRUPS . . . . . . . 40MM ( 1 1/2")

250
3-10MM Ø BOT. BARS 6-10MM Ø BARS (AS SHOWN)
4. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE SUSPENDED SLABS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20MM ( 3/4")
6-10MM Ø BARS (AS SHOWN)
WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK SHOWN ON THE 10MM Ø BOT. BARS @ 300 O.C.
DRAWINGS. 7. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP AT LEAST 40 TIMES
DIAMETER OR 600MM WHICHEVER IS GREATER. STAGGER BOTTOM AT LEAST 1.50M 10MM Ø BOT. BARS @ 300 O.C. 400 150
10MM Ø BOT. BARS
5. PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL NOT BE PLACED IN SLABS, BEAMS, OR FROM SPLICES IN OTHER BOTTOM REINFORCEMENT. STAGGER SPLICES FOR TOP 400 @ 300 O.C. 400
WALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY STRUCTURAL REINFORCEMENT SIMILARLY.
12MM Ø
MEMBER BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY SHOWN. OBTAIN
PRIOR WRITTEN APPROVAL FROM THE ENGINEER FOR INSTALLATION OF ANY 8. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS SHALL BE PROPERLY AT EDGE / PERIMETER CHB WALL AT INTERIOR CHB WALLS AT INTERIOR WALLS WITH 10MM Ø STIRRUPS

200
1@ 50, 5@ 100,
ADDITIONAL PIPES, DUCTS, ETC. POSITION AND SECURED IN PLACE PRIOR TO PLACING OF CONCRETE. WALL FOOTING DETAILS SLAB ELEVATION DIFFERENCE REST@ 300MM
LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT, PLUMBING OR 9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF 7 CONSECUTIVE DAYS (WHERE APPLICABLE) 12MM Ø
OTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED. IMMEDIATELY AFTER POURING BY THE USE OF CURING COMPOUNDS, OR OTHER
6. LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT, PLUMBING OR APPROVED METHODS. DOWEL BARS TO MATCH
HORIZONTAL REINFORCEMENT
OTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED. 10. STRIPPING OF FORMS AND SHORES:
FOUNDATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 HRS. 400 400 400 CHB WALL
TYP. BOND BEAM DETAIL
7. TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE
STRUCTURE DURING CONSTRUCTION. NEITHER THE OWNER NOR 100 100
SUSPENDED SLAB EXCEPT WHEN
ARCHITECT/ENGINEER WILL ENFORCE SAFETY MEASURES OR REGULATIONS. IT ADDITIONAL LOADS ARE IMPOSED . . . . . . . . . . . . . . . . . . . . . . . . 8 DAYS

CHB "t"

CHB "t"
SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE ADEQUATE SHORING BEAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 DAYS
AND BRACING OF THE STRUCTURE FOR ALL THE LOADS THAT MAYBE IMPOSED 400 LAP SPLICE

200
DURING CONSTRUCTION. FURTHER, THE CONTRACTOR SHALL DESIGN, CONSTRUCT (E) CAMBER REQUIREMENTS

200
300 CHB WALL
AND MAINTAIN ALL SAFETY DEVICES AND SHALL BE SOLELY RESPONSIBLE FOR

CHB "t"
CONFORMING TO ALL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 1. UNLESS OTHERWISE NOTED ON THE PLANS OR SPECIFICATIONS CAMBER ALL RC 1-16MM Ø VERT. BARS
1-16MM Ø VERT. BARS

300
BEAMS AT LEAST 10mm FOR EVERY 4000mm OF CLEAR SPAN EXCEPT CANTILEVERS

100
8. OBTAIN PRIOR WRITTEN APPROVAL FROM THE ENGINEER IN CASE OF CHANGES TO

100
WHICH WHICH SHALL BE 50mm FOR EVERY 3000mm OF CLEAR SPAN. CHB VERT. REINF. (SEE CHB VERT. REINF. (SEE
THE WORKING DRAWINGS. SCHED. OF REINF.) SCHED. OF REINF.)
CHB VERT. REINF. (SEE
2. UNLESS OTHERWISE NOTED ON THE PLANS OR SPECIFICATIONS CAMBER ALL SLABS SCHED. OF REINF.) CHB HOR. REINF. (SEE
SCHED. OF REINF.)
(B) DESIGN CRITERIA 8mm PER 3000mm OF SHORTER SPAN AND 14mm FOR EVERY 2000mm OF SLABS 16MM Ø VERTICAL REINFORCEMENT CHB HOR. REINF. (SEE
CANTILEVER SPAN. SCHED. OF REINF.) DOWEL BARS TO MATCH
DOWEL BARS TO MATCH HORIZONTAL REINFORCEMENT
- - - REFER TO STRUCTURAL COMPUTATIONS HORIZONTAL REINFORCEMENT

400 LAP SPLICE


(F) MASONRY AND CONCRETE BLOCKS CHB HOR. REINF. (SEE
SCHED. OF REINF.)
(C) FOUNDATION
1. CONCRETE HOLLOW BLOCKS, UNLESS OTHERWISE SPECIFIED SHALL BE 150MM
1. FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COMPACTED THICK. LOAD BEARING BLOCKS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF CHB "t"
CHB "t" CHB "t"
STRUCTURAL FILL OR BOTH) AT LEAST 450MM BELOW LOWEST ADJACENT FINISHED 750 PSI (5.175 MPa) WHILE NON-LOAD BEARING SHALL HAVE A MINIMUM
GRADE. COMPRESSIVE STRENGTH OF 400 PSI (2.76 MPa).
WALL REINFORCING AT CORNER WALL REINFORCING AT INTERSECTION WALL REINFORCING AT
2. FOOTING IS DESIGNED FOR ASSUMED ALLOWABLE SOIL/FOUNDATION PRESSURE OF 2. PROVIDE 1-16MMØ VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS,
144 kPa (3,000 psf). EACH SIDE OF OPENINGS. END/ DOOR OPENING
3. SUB-GRADE PREPARATION INCLUDING DRAINAGE, EXCAVATION, COMPACTION, 3. LINTEL BEAMS SHALL BEAR AT LEAST 200MM (8") ON EACH SIDE OF MASONRY WALL
AND FILLING REQUIREMENTS, SHALL CONFORM STRICTLY WITH THE OPENING. 400
RECOMMENDATIONS GIVEN IN THE SOILS REPORT OR AS DIRECTED BY THE SOILS

100MM
4. WALL REINFORCEMENTS SHALL BE AS FOLLOWS:
ENGINEER. CHB WALL WC-1
WALL THICKNESS VERTICAL BARS HORIZONTAL BARS
4. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING EXCAVATION CHB VERT. REINF. (SEE 100 150 2Ø12 VERT. BAR
HAVE BEEN COMPLETED AND PRIOR TO CONCRETING TO CONFIRM THE DESIGN 8 IN. (200 mm) . . . . . . . . . . 12MMØ @ 400 mm 10MMØ @ 600 mm SCHED. OF REINF.) CHB. VERT. REINF. (SEE Ø10 TIES SPACED@
FOUNDATION CAPACITY. 6 IN (150 mm) . . . . . . . . . . . 10MMØ @ 400 mm 10MMØ @ 600 mm SCHED. OF REINF.)

DOWEL TO MATCH
150 O.C TO C.L (TYP.)

CHB VERT. BARS


400 ALTERNATELY PLACED
4 IN. (100 mm) . . . . . . . . . . 10MMØ @ 400 mm 10MMØ @ 600 mm CHB VERT. REINF. DOWELS 2Ø12 HOR. BAR 2Ø12 HOR. BAR
5. ROOF AND AREA DRAINAGE SHALL BE DIRECTED AWAY FROM THE FOUNDATIONS. (TO MATCH VERT. REINF.)

150MM
400

400
5. BLOCK WALL REINFORCING BARS SHALL BE LAPPED OF 30 BAR DIAMETERS WHERE
6. EXCAVATIONS SHALL BE PROPERLY BACKFILLED. BACKFILL FOR WALLS SHALL BE
SPLICED, HORIZONTAL/VERTICAL DOWELS FROM FOOTINGS, COLUMNS/WALLS OR
Ø10 SPACED
@150 O.C (TYP.)
Ø10 SPACED
@150 O.C (TYP.)
WC-2
PERVIOUS MATERIAL ACCEPTABLE TO THE GEOTECHNICAL ENGINEER. DO NOT PLACE ALTERNATELY PLACED ALTERNATELY PLACED
SLABS SHALL EXTEND INTO THE BLOCK WALL A MINIMUM OF 30 BAR DIAMETERS OR A 4Ø12 VERT. BARS W/1Ø10
BACKFILL BEHIND WALLS BEFORE THEY HAVE ATTAINED THEIR DESIGN STRENGTH. SUSPENDED SLAB TIES; SPACED@150 TO C.L (TYPICAL)
MINIMUM OF 400MM WHICHEVER IS LONGER AND DOWELS TO MATCH VERTICAL
SHORE AND PROTECT WALLS FROM LATERAL LOADS UNTIL THE SUPPORTING
REINFORCEMENTS OF WALL. NOTE: PROVIDE STIFFENER COLUMN AT EVERY 4.0 METER MAX. SPACING
MEMBERS ARE IN PLACE AND HAVE DEVELOPED SPECIFIED STRENGTHS. WB-1 WB-2
(G) STRUCTURAL STEEL WALL BASE TYP. STIFFENER COLUMN
TYP. CHB STIFFENER BEAM DETAIL DET. ON CHB WALLS
(D) REINFORCED CONCRETE 1. ALL STRUCTURAL STEELS SUCH AS ANGLES, WIDE FLANGE SECTIONS, PIPES,
REINFORCEMENT
1. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN STIFFENER PLATES, BASE PLATES, ETC. SHALL CONFORM TO ASTM A-36. AT FLAT FLOOR
ACCORDANCE WITH THE PROVISIONS SET BY THE NSCP 2001.
2. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED BASED ON
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS THE SPECIFICATION FOR DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL
WITH CORRESPONDING MAXIMUM SLUMP AND MAXIMUM SIZE AGGREGATE AS STEEL GIVEN BY THE NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (NSCP). RET. WALL/CHB WALL
FOLLOWS: 3
3. CONNECTION BOLTS ROUND, UNLESS SHOWN OTHERWISE) SHALL CONFORM TO SAW-CUT GROOVE 8MM SAW-CUT GROOVE 8MM WIDE
(4 WIDE TO BE FILLED WITH 65MM DEEP TO BE FILLED WITH
STRUCTURAL MEMBER 28 DAY STRENGTH MAX. SLUMP MAX. SIZE AGG. ASTM A-325. ANCHOR BOLTS (EMBEDDED IN MASONRY OR CONCRETE) SHALL POLYURETHANE SEALANT POLYURETHANE SEALANT POLYURETHANE SEALANT
CONFORM TO ASTM A307 UNLESS NOTED OTHERWISE ON THE DRAWINGS. SLAB REINF. SLAB REINF. SLAB REINF.
A. SLAB ON GRADE 20.7 MPa (3,000 PSI) 100MM (4") 25MM (1")
B. FOOTINGS & RETAINING WALLS 20.7 MPa (3,000 PSI) 100MM (4") 19MM (3/4") 4. ALL STRUCTURAL STEEL SHALL BE CLEAN, RUST FREE AND SHOP COATED WITH THE FLR. LVL. FLR. LVL. FLR. LVL.
20MM MIN. 20MM MIN.

SLAB

SLAB
APPROPRIATE PAINT. STRUCTURAL STEEL AND ANCHOR BOLTS SHALL BE MINIMUM

"t"

"t"
C. COLUMNS / SHEARWALLS 20.7 MPa (3,000 PSI) 100MM (4") 19MM (3/4") CONC. COVER CONC. COVER
250
D. BEAMS & SLABS 20.7 MPa (3,000 PSI) 100MM (4") 19MM (3/4") ASTM A-36 DOMESTIC, LATEST REVISION.

100

100
CONSTRUCTION JOINT
5. NON - SHRINK GROUT - PRE-MIXED, NON-METALLIC, CEMENT-BASED GROUT, MEETING
3. ALL REINFORCING STEEL BARS SHALL CONFORM TO ASTM A615 GRADE 40 FOR THE REQUIREMENT OF ASTM C827, ASTM C109 & CRD-C621, WITH A MINIMUM
12MMØ AND SMALLER BARS WHILE BARS 16MMM Ø AND LARGER SHALL BE GRADE 60. COMPRESSIVE STRENGTH OF 7000psi AT 28 DAYS. 400
COMPACTED GRAVEL SUBGRADE COMPACTED COMPACTED GRAVEL SUBGRADE COMPACTED
6. PROVIDE MISCELLANEOUS PLATES, ANGLES AND ANCHORS AS SHOWN OR NOTED ON BEDDING (TYP.) TO 95% OF MAXIMUM BEDDING (TYP.) TO 95% OF MAXIMUM
4. ALL FABRICATION, DETAILING AND PLACING SHALL CONFORM TO THE PROVISIONS COMPACTED GRAVEL SUBGRADE COMPACTED
DRAWINGS. BEDDING (TYP.) TO 95% OF MAXIMUM VAPOR BARRIER DRY DENSITY @ OPTIMUM VAPOR BARRIER DRY DENSITY @ OPTIMUM
SET BY THE NSCP 2001 EDITION. DRY DENSITY @ OPTIMUM WHEN REQUIRED MOISTURE CONTENT (MAX. WHEN REQUIRED MOISTURE CONTENT (MAX.
7. ALL CUTTING AND BLOCKING OF STEEL SHALL BE SHOWN ON SHOP DRAWINGS AND VAPOR BARRIER DEPTH OF COMPRESSED DEPTH OF COMPRESSED
WHEN REQUIRED MOISTURE CONTENT (MAX.
DEPTH OF COMPRESSED FILL = (200mm PER LAYER). FILL = (200mm PER LAYER).
5. CLEAR DISTANCE SPACING BETWEEN PARALLED BARS IN A LAYER SHALL NOT BE PERFORMED IN SHOP.
FILL = (200mm PER LAYER).
LESS THAN 1.50 TIMES THE NOMINAL DIAMETER OF THE BAR, OR 1.33 TIMES MAXIMUM
SIZE AGGREGATE, NOR LESS THAN 38MM (1 2").
1
8. PROVIDE TEMPORARY BRACING AS REQUIRED FOR A SAFE STRUCTURE UNTIL ALL
FINAL CONNECTIONS ARE MADE. SLAB-ON-GRADE EXPANSION SLAB-ON-GRADE CONSTRUCTION SLAB-ON-GRADE CONTRACTION
JOINT DETAIL JOINT DETAIL JOINT DETAIL
FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or -AS SHOWN
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER DRAFTSMAN
S-100
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
NENIO SASITA
GLENDA MARCUELO R 0
REPUBLIC OF THE PHILIPPINES
4-Ø[email protected] LONG DEPARTMENT OF PUBLIC WORKS
TOP BARS BENT DOWN AND HIGHWAYS
INTO EDGE BEAM. EXTEND
BARS MIN. OF 1.20M OFFICE OF THE BUILDING OFFICIAL
CECU CITY

RECOMMENDING APPROVAL

60
0
HEAD STRUCTURAL DATE
COLUMN TIES AS PER SECTION
SCHEDULE, MAX.
BOTTOM BARS STIRRUPS SPACING = APPROVED:
SPACED @150MM O.C. 6Ø BARS OR 150mm. CHB "t"
600

1-Ø12x675MM
1-Ø12x975MM
STRUCTURAL R.C.
COLUMN
A PIPE SLEEVE
1-Ø12x1275MM REQUIRED
600 1-Ø12x1575MM TABLE OF LAP SPLICE BUILDING OFFICIAL DATE

CORNER SLAB DETAILS CONCRETE FILLER PARAMETERS


PIPE
MATERIAL psi MPa ACI 318-05
CONFINING REINF. ZONE
BOND BEAM(SEE TYP. DETAIL) f'c 3000 20.7 DEV'T & SPLICE LENGTH
MAXIMUM OF CONCRETE
1. CLEAR HEIGHT FILLER
2. MAX. COL. DIMENSION fy 60000 414 16mm & HIGHER
3. 450mm.
fyh 40000 276 12mm & LOWER
STIFFENER COLUMN @ EVERY 3.00M

tie Ø 10 stirrup Ø 10
TOP OF FOUNDATION MASTIC SEALANT fyt 40000 fyt 40000

12mm GAP
300 min. JOINT EACH SIDE

(MIN.)
(SEE TYP. DETAILS)

REINF. ZONE PIPE SLEEVE STANDARD HOOK (mm) TENSION LAP SPLICE (mm)
@FOUNDATION REQUIRED PIPE SLEEVE BARØ ANCHORAGE BEAM COMP.
Ldh(mm) UNIT WT.
COMPRESSIBLE (mm) LENGTH (mm) SPLICE (mm) BEAM COLUMN

FOOTING t
FOUNDATION 90° 180° 135°-90° LAP CLASS (kg/m)
ADD'L 16mmØ MATERIALS TOP BAR BOTTOM BAR TIED SPIRAL
CROSS TIES SEE DETAILS
SPACED @ 400
& REINF. CHB WALL A 380 300
10 600 150 160 110 120~120 300 300 300 0.616
O.C. WITHIN B 490 390
FOOTING
SECTION A-A 12 710 260 200 120 130~130 350
A 680 520
520 520 0.888
B 880 680
PROVIDE REBAR
CHAIRS AS DEEMED
PIPE SLEEVE THRU WALL 16 950 350 260 130 160~160 460
A
B
910
1180
700
910
700 700 1.579
NECESSARY BY
THE CONTRACTOR
A 1140 870
20 1180 440 320 160 200~320 580 870 870 2.466
B 1480 1130
COLUMN/ SHEAR WALL VERTICAL BARS 25 1900 550 400 200 250~400 720
A
B
1780
2310
1370
1780
1370 1370 3.854

ROOF BEAM
EMBEDMENT TO FOOTING DETAIL NOTES:
1. BARS ALONG THE SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG THE LONGER SPAN AT 28 2190 620 480 260 810
A 1990 1530
1530 1530 4.833
B 2590 1990
MIDSPAN AND OVER THE LONGER SPAN AT SECTIONS NEAR SUPPORT (COLUMN LINE).
PARAPPET WALL DETAIL 2. BAR SPACING ALONG COLUMN STRIP CAN BE APPROXIMATELY 1-1/2 TIMES OF THE MIDDLE STRIP BUT IN NO 32 2590 700 550 290 930
A 2270 1750
1750 1750 6.313
B 2950 2280
CASE GREATER THAN 3 TIMES THE SLAB THICKNESS.
3. IF TOP BARS OF ADJACENT SLABS DIFFER AT THEIR COMMON SUPPORT, THE SMALLER SPACING SHALL GOVERN. A 2560 1970
36 2990 790 650 360 1040 1970 1970 7.991
B 3330 2560
200 W = 1.20m (max) 200 200 W = 1.20m (max) 200
La = SHORT SPAN La = SHORT SPAN NOTES:
1. DEVELOPMENT LENGTH OF INDIVIDUAL BARS WITHIN A BUNDLE, IN TENSION OR COMPRESSION, SHALL BE THAT FOR INDIVIDUAL BARS,
DISCONTINUOUS EDGE DISCONTINUOUS EDGE INCREASED 20% FOR THREE-BUNDLED AND 33% FOR FOUR-BUNDLED BARS.
2. FOR COLUMNS AT ANY LEVEL, NO MORE THAN ALTERNATE BARS SHOULD BE SPLICED, NOTMORE THAN 33% OF THE BARS SHALL BE SPLICED WITHIN
THE REQUIRED LAP LENGTH, MINIMUM DISTANCE BETWEEN TWO ADJACENT SPLICED SHALL BE 600mm.

COLUMN

COLUMN
LONG DIRECTION LONG DIRECTION 3. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 300mm DEPTH OF CONCRETE CAST BELOW REINFORCEMENT.

Lb/4 =

STRIP

Lb/4 =

STRIP
Lb/4
BARS (DISCONT.) 4. LAP SPLICE SHALL BE "CLASS B" TENSION LAP SPLICE IF MORE THAN ONE HALF OF THE BARS WERE SPLICED AT ANY SECTION, WHILE "CLASS A"

>150mm
BARS TENSION LAP SPLICE IF HALF OR FEWER THAN HALF OF BARS WERE SPLICED.

DISCONTINUOUS EDGE
2 - 12MM Ø TOP 2 - 12MM Ø TOP
& BOTTOM BARS & BOTTOM BARS SHORT DIRECTION La / 6 >150MM

DISCONTINUOUS EDGE
La/4
BARS (CONT.) STAIR SCHEDULE

CONTINUOUS EDGE
Lb = LONG SPAN

Lb = LONG SPAN
MIDDLE STRIP

MIDDLE STRIP
CONTINUOUS EDGE
WINDOW

Lb/2 =

Lb/2 =
OPENING
CHB WALL CHB WALL
La/3
SHORT DIRECTION CLEAR SPAN THICKNESS MAIN
BARS (DISCONT.)
SHORT DIRECTION REMARKS
BARS (M) (M) REINFORCEMENTS
DOOR
H

OPENING

Lb/3

COLUMN

COLUMN
CUT 1 OF EVERY 2

Lb/4 =

STRIP

Lb/4 =

STRIP
LONG DIRECTION 4.00 0.125 16Ø @ 0.20M O.C.
BARS @ SPAN / 6 @

Lb / 6
BARS (CONT.)
THE CONTINUOUS
5.00 0.150 16Ø @ 0.15M O.C.
16MM Ø VERT. 16MM Ø VERT. EDGE ONLY
BARS BARS CONTINUOUS EDGE MATERIALS SPECIFICATION:
CONTINUOUS EDGE
fc' = 20.7 MPa (3,000 psi) fy = 414 MPa (60,000 psi) FOR 12MM Ø AND LARGER BARS
La/4 = La/4 = La/4 = La/4 = NOTE:
COLUMN La/2 = COLUMN COLUMN La/2 = COLUMN
STRIP MIDDLE STRIP STRIP STRIP MIDDLE STRIP STRIP 1. STAIR SPAN IS THE DIFFERENCE BETWEEN ADJACENT STAIR SUPPORTS
WHETHER IT IS A BEAM OR AN R.C. WALL
TOP BARS LAYOUT BOTTOM BARS LAYOUT
TYPICAL DOOR OPENING TYPICAL WINDOW OPENING 2. CONSULT AND SEEK THE APPROVAL OF THE STRUCTURAL DESIGN ENGINEER

WITH LINTEL BEAM WITH LINTEL BEAM TYPICAL TWO WAY R.C. SLAB DETAIL IN CASE THERE ARE NO STAIR SUPPORTS.

UPPER FLOOR BEAM


SEE BEAM SCHEDULE

MAIN REINF.
NOTE:
PROVIDE 20MM CLEAR CONCRETE COVER (SEE TABLE)
L /4
L/3 L/4 PROPOSED PIPE SLEEVE LOCATIONS
2D (NO PIPE SLEEVE
TOP BARS @ 2 - 10Ø TIE BARS TOP BARS @ SCH. 40 G.I. PIPE SLEEVE SHALL BE ALLOWED W/IN MAIN REINF.
L 10MM Ø HORIZONTAL
CONTINUOUS EDGE ON EACH SIDE DISCONT. EDGE THIS ZONE (TYP.)) (SEE TABLE)
2 - EXTRA STIR. EA. SIDE BARS @ 0.30M O.C.
OF SLEEVE
2 EXTRA STIRRUPS
2D 0 2D
50 P.) EACH SIDE OF SLEEVE
12mm Ø NOSING
t (SLAB THICKNESS) Y B
TOP BARS (T FACE OF TOP BARS BARS
CUT 1 OF EVERY 2 A
SUPPORT 4
BOTTOM BARS @ L / 6 @ BOTTOM BARS Ø16 EXTRA BARS L/
THE CONTINUOUS EDGE
40

@ MIDSPAN E.F. (DIAGONALS)

TH EE T
L/6

(S
IC AB
ONLY >150MM 12MM Ø VERTICAL BARS

KN L
ES E)
MAIN REINF.

S,
D

t
L (CLEAR SPAN)
PIPE SLEEVE @ 0.15M O.C.
D/5

D/5

(SEE TABLE)
40

Ø 16 CROSS ANCHORS
TYPICAL SLAB SECTION Ø 16 EXTRA BARS E.F. WELDED TO SLEEVE
BOT. BARS A (TYPICAL) SUPPORT
NOTES: FACE OF 4d (MIN.) BOTTOM BARS FORMING BARS (BEAM OR R.C.
STIR. AS SCHED. 0.50
PROVIDE 20MM CLEAR CONCRETE COVER
L/2 L/2
SUPPORT
L/4 L/2 L/4 SECTION A - A 12mm Ø @ 0.30M
O.C.
WALL)

LIMIT LOCATION OF PIPE SLEEVE NOTES:


TOP BARS @ TOP BARS @ L SECONDARY
1. SEEK STRUCT'L ENGINEER'S 3. NO PIPE SLEEVE SHALL BE REINF.
CONTINUOUS EDGE DISCONTINUOUS EDGE APPROVAL FOR PIPE SLEEVES ALLOWED AT TWICE THE
LEGEND: PIPE SLEEVE MAXIMUM DIAMETER 10mm Ø @ 0.30M
W/ DIAMETERS BIGGER THAN BEAM DEPTH (2D) FROM
1. D = DEPTH OF BEAM/GIRDER IS : (LEAST GOVERNS) THE MAXIMUM STIPULATED. THE SUPPORT. O.C. LOWER FLOOR BEAM
BOTTOM 10Ø TIE BARS A) 1/5 OF BEAM DEPTH
t (SLAB THICKNESS) 2. d = PIPE SLEEVE DIAMETER SEE BEAM SCHEDULE
100MM

BARS @ 0.30M O.C. B) 100 MM 2. PIPE SLEEVES SHALL BE


L (CLEAR SPAN) LOCATED WITHIN TENSION
ZONES OF BEAM. SUPPORT
(BEAM OR R.C. STAIR SPAN (SEE TABLE)
TYPICAL CANTILEVER WALL)

SLAB SECTION
PIPE SLEEVE THRU BEAM DETAIL
TYPICAL STAIR DETAIL RC WALL FOR STAIR SUPPORT

FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or -AS SHOWN
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER DRAFTSMAN
S-200
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
NENIO SASITA
GLENDA MARCUELO R 0
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS
COLUMN VERTICAL BARS
(SEE COLUMN SCHEDULE) OFFICE OF THE BUILDING OFFICIAL
COLUMN TIES/HOOPS Y-DIRECTION Y-DIRECTION
BARS BARS CECU CITY
(SEE SCHEDULE)
FINISH FLOOR LINE
NOTES:
FOOTING TIE BEAM 1. BARS ALONG THE SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG THE LONGER SPAN AT RECOMMENDING APPROVAL
(SEE SCHEDULE) MIDSPAN AND OVER THE LONGER SPAN AT SECTIONS NEAR SUPPORT (COLUMN LINE).
EMBEDMENT DEPTH

2. IF TOP BARS OF ADJACENT SLABS DIFFER AT THEIR COMMON SUPPORT, THE SMALLER SPACING SHALL GOVERN.

VARIES
L (SHORT SPAN) L (SHORT SPAN)
HEAD STRUCTURAL DATE

B1
FILL FILL

B2
SECTION
DISCONTINUOUS EDGE DISCONTINUOUS EDGE
X-DIRECTION APPROVED:

L/4
X-DIRECTION LONG DIRECTION SHORT DIRECTION
BARS
0.075

BARS BARS (DISCONT.) BARS

>150MM
DISCONTINUOUS EDGE
>150MM

DISCONTINUOUS EDGE
t

CONTINUOUS EDGE
L1 L2
BUILDING OFFICIAL DATE
PLAN

CONTINUOUS EDGE
50MM THK LEAN CONCRETE SHORT DIRECTION BARS L/6
FOOTING 1 FOOTING 2 (CONT.) L/4
SECTION
VERTICAL COLUMN BARS L/3
X-DIRECTION Y-DIRECTION
(SEE SCHEDULE) COLUMN TIES/HOOPS SHORT DIRECTION
BARS BARS
(SEE SCHEDULE) BARS (DISCONT.)
MAIN TOP BARS CUT 1 OF EVERY
TIE BEAM
(SEE SCHEDULE) 2 BARS @ L / 6 @ THE
FINISH FLOOR LINE CONTINUOUS EDGE ONLY
b LONG LONG DIRECTION
b

L/4
DIRECTION BARS

VARIES
TOP BARS

EMBEDMENT DEPTH
BARS (CONT.)
A CONTINUOUS EDGE CONTINUOUS EDGE
B

h
BOTTOM BARS TOP BARS LAYOUT BOTTOM BARS LAYOUT
SECTION A - A
FOOTING TYPICAL ONE WAY R.C. SLAB DETAIL

t1 (mm)

t2 (mm)
BARS
MAIN BOTTOM BARS A
L 50MM THK LEAN CONCRETE 50MM THK LEAN CONCRETE

75

75
BOTTOM BARS LAYOUT PLAN L1 L2
SECTION
TYPICAL FOOTING DETAILS TYPICAL TIE BEAM TO FOOTING DETAILS
NOTES: 30 BAR Ø (min) 30 BAR Ø (min)
1. L1, L2 = LENGTH OF CLEAR SPANS 1, 2 (FACE OF SUPPORT TO FACE OF SUPPORT)

DEPRESSION
D=FOR BEAM
t=FOR SLAB
2. L = THE GREATER LENGTH OF L1 OR L2

VERIFY
3. AT INTERIOR SUPPORT (CONTINUOUS END) PROVIDE LARGER SIZE AND NUMBER OF
TOP BARS FROM ADJACENT SPANS. FOR SIZE, AND SPACING OF
4. EXTERIOR AND INTERIOR SUPPORT REINFORCEMENT NOT SHOWN FOR CLARITY STIRRUPS, SEE REINFORCED
CONCRETE BEAM SCHEDULE
SLOPE 1:2 V:H

STIRRUP (TYPICAL)
INTERIOR SUPPORT INTERIOR SUPPORT INTERIOR SUPPORT 30 BAR Ø (min)

40mm CLEAR TO
L1 / 4 TOP BAR L/4 L/4 TOP BAR L/4 L/4 D=FOR BEAM
2t=FOR SLAB
SPLICE ZONE (TYP.) SPLICE ZONE (TYP.) CONCRETE BEAM
TOP BARS
40mm CLEAR TO
BEAM/SLAB CHANGE SOFFIT DETAIL
STANDARD 90
TOP BARS TOP BARS EXTRA TOP BARS CONT. TOP BARS ADDITIONAL ROW OF TOP STIRRUPS TYPICAL
DEGREE HOOK
(TYPICAL) BARS (AS REQUIRED)

EQUALEQUALEQUAL

(SEE SCHEDULE)
L1 / 6 L1 / 6 L2 / 6 L2 / 6
EXTRA EXTRA
STIRRUP (TYPICAL)

MAIN REINFORCEMENTS

DEPTH
40mm CLEAR TO

BOTTOM BOTTOM 25 MAIN REINFORCEMENTS TO BE


BARS BOTTOM BAR BARS BOTTOM BAR CONTINUOUS (TOP & BOT. BARS)

t/2
SPLICE ZONE (TYP.) SPLICE ZONE (TYP.) BEAM STIRRUPS

t
t/2
CONTINUOUS CONTINUOUS
SIDE BARS (TYP.) SEE 30 BAR Ø 50 30 BAR Ø
BOTTOM BARS BOTTOM BARS
SCHEDULE FOR SIDE
40MM CLEAR MIN. Ø10 x 1.0m LONG @ 300 O.C. (MIN.) (MIN.)
AND NUMBER ADDITIONAL ROW OF BOTTOM
75MM CLEAR
EXTERIOR MAX.
SUPPORT (PLACED AT MID-DEPTH OF SLAB
CONCRETE CONCRETE BARS (AS REQUIRED) IF THE LOCATION OF THE CONST.
(DISCONTINUOUS END)
COLUMN COLUMN WEB BARS JOINT IS NOT WITHIN THE MIDDLE
WIDTH

D/2
OR BEAM OR BEAM (TYPICAL) THIRD.
BOTTOM BARS (SEE SCHEDULE)
(TYPICAL) (TYPICAL)
L1 L2 L1 OR L2 SUSPENDED SLAB CONSTRUCTION

D/2
(CLEAR SPAN) (CLEAR SPAN) (CLEAR SPAN) NOTE: SLAB REINFORCEMENT NOT SHOWN FOR CLARITY
INTERIOR SUPPORT INTERIOR SUPPORT JOINT DETAIL
(CONTINUOUS END) (CONTINUOUS END) SECTION PROVIDE 2-Ø25 SHEAR BARS EACH
SIDE IF BEAM CONSTRUCTION JOINT
ELEVATION
TYPICAL GRAVITY REINFORCED CONCRETE BEAM DETAIL IS NOT WITHIN THE MIDDLE THIRD
OF THE SPAN.

BEAM CONSTRUCTION
Ø12x1000mm LONG DIAGONALS AT
JOINT DETAIL
400

MID-DEPTH OF SLAB AT EACH CORNER.


1-Ø12 TOP &
BOT. BARS
GRID
LAP SPLICE LENGTH: FOUNDATION TOP
ALTERNATE HOOK @ EDGE ADDITIONAL SHEAR BARS
1. AT ANY LEVEL NO MORE THAN OF SLAB LOCATION
40mm. CLEAR 75 mm PROVIDE CLEARANCE BARS AS SCHEDULED Ø25 X 1500 LONG @ 200 O.C.
H (CLEAR HEIGHT OF COL.)

ALTERNATE BARS SHOULD BE TO AVOID SLAB &


MAXIMUM SPLICED. (EACH DIAGONAL PAIR PER SET)
400

BEAM TOP REINFORCEMENT SLAB THICKNESS


10MM Ø VERTICAL BARS 2. MIN. DISTANCE BETWEEN TWO
IN TWO WAY SPACED @ 400MM O.C. ADJACENT BAR SPLICES SHALL
SLAB EXTEND SLAB ON GRADE BE 600mm.
WITHIN CENTER

BARS UP TO
HALF OF "H"

L CONCRETE BEAM
BEAM SUPPORT

H/3
100

L/4

THICKNESS (H)
90 DEGREE STANDARD HOOK
ADDITIONAL TRIMMER BARS(SHOWN AS
DOTTED LINES), AT SIDES OF OPENING TOP BARS @ SUPPORT (CONT.)
VARIES

EQUAL TO THE NUMBER OF BARS GRAVEL BED

H/3
REQ'D. BOT. BARS @ SUPPORT 1
DOWEL LENGTH

NOTE: TERMINATED BY THE OPENING.


VARIES

1
OMIT TRIMMER BARS WHERE 40mm CLEAR TO TIES (TYP.)
JT. REINF.
LAT. TIES

OPENING IS FRAMED BY BEAMS. 150MM THICK CONCRETE COLUMN

H/3
EXTERIOR CHB WALL (SEE SCHED. FOR SIZE)
NOTES: VERTICAL COLUMN
1. PROVIDE THESE ADDITIONAL BARS FOR ALL OPENINGS PLUS BARS REINFORCEMENT (TYP.)
Ø12@100
200

(SHOWN AS DOTTED LINES) PARALLEL TO SIDE OF OPENING


CONF. REINF. TIES

L/6 SPLICE EXTRA BOT. BARS


EQUAL TO THE NUMBER OF INTERRUPTED BARS BY THE OPENING. HOOPS @ MIDSPAN
225 mm WIDE x 6mm THK.
BOT. BARS PVC WATERSTOP W/FLAT TYPE
2. SEE ARCHITECTURAL & MECHANICAL PLANS FOR SLAB FOOTING TIE BEAM 2d @ MIDSPAN FOUNDATION BOTTOM UNDERSIDE W/ FINS ON THE
OPENING LOCATION. EXTRA TOP BARS BARS AS SCHEDULED FOUNDATION SIDE
@ SUPPORT COLUMN TIES (TYP.)

3. THE ADDITIONAL BARS ARE REQUIRED TO EXTEND FROM SUPPORT BLINDING CONCRETE
TO SUPPORT ON ALL FOUR SIDES OF A TWO-WAY SLAB. (THICKNESS AS DETAILED)
THE PRIMARY REINFORCING BARS IS REQUIRED TO EXTEND FROM
SUPPORT TO SUPPORT ON ONE-WAY SLABS. COLUMN LAP SPLICE AND EXT. TYPICAL GRAVITY TOP OF FOOTING CONSTRUCTION
SLAB OPENING DETAIL TYPICAL WALL TO TIE BEAM DETAILS GIRDER TO COLUMN CONNECTION DETAIL CONCRETE COLUMN DETAIL JOINT DETAIL

FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or -AS SHOWN
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER DRAFTSMAN
S-300
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
NENIO SASITA
GLENDA MARCUELO R 0
REPUBLIC OF THE PHILIPPINES
A B C D A B C D DEPARTMENT OF PUBLIC WORKS
A B C D 10900
AND HIGHWAYS
10900
10900
3100 4400 1400 2000
OFFICE OF THE BUILDING OFFICIAL
3100 4400 1400 2000
3100 4400 3400 CECU CITY

RECOMMENDING APPROVAL

2000

2000

2000

2000
2000

2000
HEAD STRUCTURAL DATE
2G-7A (200x450) 2G-7 (200x450) RG-1 (200x400) RG-1 (200x400) SECTION
1 1
1 F2C2
FTB (200x400) FTB (200x400)
APPROVED:

2G-3 (200x450)
F1C1 F1C1

RG-1 (200x400)

RG-2 (200x400)

RG-1 (200x400)
2G-1 (200x450)

2G-1 (200x450)
FTB (200x400)
FTB (200x400)

3700

3700

3700

3700
2S-2 2S-3 BUILDING OFFICIAL DATE
3700

3700
SCHEDULE OF
ELEV=0.30 SLAB
CONCRETE
TYPICAL
FILL M ON

ELEV=0.30 SLAB
CONCRETE
TYPICAL
FILL M ON

ELEV=0.30 SLAB
CONCRETE
TYPICAL
FILL M ON

2G-5A (200x450) 2G-5 (200x450) RG-2 (200x400)


FTB (200x400) FTB (200x400) F3C1
2 2
2 F2C2
F1C1 F1C1 2S-4 2S-5
RG-1 (200x400)
FOOTING TIE BEAMS

13400

13400

13400

13400
2S-1
13400

13400

2G-1 (200x450)
2G-2 (200x450)

RG-1 (200x400)
2G-1 (200x450)

RG-1 (200x400)
REFER TO CANTILEVER
BEAM SECTION
FTB (200x400)

SLAB DETAIL

FTB (200x400)
MARK

2G-2 (200x450)
4700

4700

4700

4700
100mm THK. SLAB-ON-GRADE LEFT END MIDSPAN RIGHT END
4700

4700
WITH 10mmØ TEMP. BARS
@ 0.45M O.C. BOTH WAYS
SECTION SECTION SECTION
SIZE (MM) 200X400 200X400 200X400
TOP BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø

2G-1 (200x450)
F2C2
3

FTB - 1
3
FTB (200x400) FTB (200x400)

F3C3
2G-4 (200x450) 2G-4 (200x450) 3 RG-1 (200x400) BOTTOM BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø
F3C4
WEB BARS NONE NONE NONE
10MM Ø: 1@50mm, 10@100mm,

3000

3000

3000

3000
STIRRUPS
10@150mm, REST @ 300mm O.C.
3000

3000
MATERIALS SPECIFICATION: fc' = 20.7 MPa (3,000 psi)
fy = 414 MPa (60,000 psi)

3000 5900 2000 3000 5900 2000


3000 5900 2000
10900 10900
10900

FOUNDATION PLAN SECOND FLOOR PLAN ROOF BEAM PLAN SCHEDULE OF RC COLUMNS
SCALE 1:100 SCALE 1:100
SCALE 1:100 FOUNDATION TO SECOND FLOOR TO
MARK SECOND FLOOR LEVEL ROOF LEVEL

SCHEDULE OF SLABS SCHEDULE OF FOOTINGS


C1
SPACING OF REINFORCING BARS (mm) FOOTING DIMENSIONS TOP BARS BOTTOM BARS
EMBEDMENT
MARK THICKNESS BAR SHORT DIRECTION BARS LONG DIRECTION BARS MARK DEPTH (m) REMARKS SIZE 200 mm x 400 mm 200 mm x 300 mm
REMARKS WIDTH, B LENGTH, L THICKNESS X-DIRECTION Y-DIRECTION X-DIRECTION Y-DIRECTION
(mm) LOCATION
@ CONTINUOUS @ DISCONT. @ CONTINUOUS @ DISCONT. (m) (m) t (m) BARS BARS BARS BARS VERT. BARS 8 - 16mm Ø 6 - 16mm Ø
@ MIDSPAN @ MIDSPAN
EDGE EDGE EDGE EDGE TIES / SPIRAL 3 SETS - 10Ø @ 150mm 3 SETS - 10Ø @ 150mm
F1 1.60 1.60 0.30 1.20 NONE NONE 8 - 16mm Ø 8 - 16mm Ø ISOLATED FOOTING
TOP BARS 12Ø @ 300 NONE 12Ø @ 300 12Ø @ 300 NONE 12Ø @ 300 CONF. REINF. 3 SETS - 6 PCS 10Ø @ 100mm 3 SETS - 6 PCS 10Ø @ 100mm
2S-1 100 TWO WAY F2 1.60 1.60 0.30 1.20 NONE NONE 8 - 16mm Ø 8 - 16mm Ø CANTILEVER FOOTING
BOTTOM BARS 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 JOINT REINF. 3 SETS - 10Ø @ 100mm 3 SETS - 10Ø @ 100mm
TOP BARS 12Ø @ 300 NONE 12Ø @ 300 12Ø @ 300 NONE 12Ø @ 300 F3 1.20 1.20 0.30 1.20 NONE NONE 6 - 16mm Ø 6 - 16mm Ø ISOLATED FOOTING
2S-2 100 TWO WAY
BOTTOM BARS 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300
TOP BARS 12Ø @ 300 NONE 12Ø @ 300 12Ø @ 300 NONE 12Ø @ 300
2S-3 100 TWO WAY C2
BOTTOM BARS 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300
MATERIAL SPECIFICATIONS: ALLOWABLE SOIL PRESSURE:
TOP BARS 12Ø @ 300 NONE 12Ø @ 300 12Ø @ 300 NONE 12Ø @ 300 fc' = 20.7 MPa (3,000 psi) qa = 144 kPa (3,000 psf)
2S-4 100 TWO WAY SIZE 200 mm x 400 mm 200 mm x 300 mm
BOTTOM BARS 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 fy = 414 MPa (60,000 psi) FOR 16MMØ BARS AND ABOVE
VERT. BARS 8 - 16mm Ø 6 - 16mm Ø
TOP BARS 12Ø @ 300 NONE 12Ø @ 300 12Ø @ 300 NONE 12Ø @ 300
2S-5 100 TWO WAY TIES / SPIRAL 3 SETS - 10Ø @ 150mm 3 SETS - 10Ø @ 150mm
BOTTOM BARS 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300 12Ø @ 300
CONF. REINF. 3 SETS - 6 PCS 10Ø @ 100mm 3 SETS - 6 PCS 10Ø @ 100mm
MATERIAL SPECIFICATIONS: NOTES:
JOINT REINF. 3 SETS - 10Ø @ 100mm 3 SETS - 10Ø @ 100mm
fc' = 20.7 MPa (3,000 psi) IF TOP BARS OF ADJACENT SLABS DIFFER AT THEIR
fy = 276 MPa (40,000 psi) COMMON SUPPORT THE SMALLER SPACING SHALL GOVERN.

°
COLUMN COLUMN COLUMN 135 C3
LC L1 L2 6d
b
3/4 LC OR L1 / 4 L1 / 4 OR 3/4 LC L1 / 4 OR L2 / 4 L2 / 4 OR L1 / 4 SPLICE ZONE FOR L2 / 4 SIZE 200 mm x 400 mm 200 mm x 300 mm
SPLICE LENGTH
(GREATER GOVERNS) SEE TABLE (GREATER GOVERNS) (GREATER GOVERNS) GIRDER TOP BARS CONCRETE BEAM VERT. BARS 8 - 16mm Ø 6 - 16mm Ø
SPLICE LENGTH db
TOP BARS
40mm COVER

EQ. EQ. TOP BARS SEE TABLE


TIES / SPIRAL 3 SETS - 10Ø @ 150mm 3 SETS - 10Ø @ 150mm
(TYPICAL)

AT SUPPORT CONTINUOUS CONF. REINF. 3 SETS - 6 PCS 10Ø @ 100mm 3 SETS - 6 PCS 10Ø @ 100mm
TOP BARS AT EQ. EQ. WEB BARS
TOP BARS ADDITIONAL ROW OF TOP NOTES: JOINT REINF. 3 SETS - 10Ø @ 100mm 3 SETS - 10Ø @ 100mm
CANTILEVER'S TOP BARS TOP BARS
AT MIDSPAN BARS (AS REQUIRED)
DISCONTINUOUS AT SUPPORT AT MIDSPAN
END 1. SEE TABLE OF LAP SPLICE & ANCHORAGE

EQUAL EQUAL EQUAL


LENGTHS SHOWN ON SHEET

(SEE SCHEDULE)
40MM CLEAR TO
d

BEAM HEIGHT
2. LAP SPLICE SHALL BE LOCATED ONLY C4
STIRRUPS (TYPICAL)
WITHIN THE LAP SPLICE ZONE
40mm COVER

3. TOP & BOTTOM BARS MAY BE LAP SPLICED


BOTTOM BARS
(TYPICAL)

BOTTOM BARS 2d EQ. EQ. EQ. EQ. ONLY ON ONE LOCATION FOR EACH STRING SIZE 350 mm x 350 mm 350 mm x 350 mm
AT SUPPORT AT MIDSPAN BEAM HOOPS / STIRRUPS
2d 2d OF BEAMS
VERT. BARS 8 - 16mm Ø 8 - 16mm Ø
L1 / 6 4. CLOSED HOOPS / STIRRUPS WITH 135° BEND
TIES / SPIRAL 3 SETS - 10Ø @ 150mm 3 SETS - 10Ø @ 150mm
BOTTOM BARS SHALL BE SPACED @ 100MM O.C. MAXIMUM AT
AT CANTILEVER'S A DISTANCE 2D FROM THE FACE OF THE SUPPORT. CONF. REINF. 3 SETS - 6 PCS 10Ø @ 100mm 3 SETS - 6 PCS 10Ø @ 100mm
50mm MAX. ADDITIONAL ROW OF BOTTOM
DISCONTINUOUS FIRST STIRRUP SHALL BE 50MM FROM THE FACE
AT SUPPORT BARS (AS REQUIRED) JOINT REINF. 3 SETS - 10Ø @ 100mm 3 SETS - 10Ø @ 100mm
END L1 / 6 OF THE SUPPORT
WEB BARS MATERIALS SPECIFICATION: fc' = 20.7 MPa (3,000 psi)
HOOP REINFORCEMENT HOOP REINFORCEMENT HOOP REINFORCEMENT BOTTOM BARS
(TYPICAL) fy = 414 MPa (60,000 psi)
SEE SCHEDULE SEE SCHEDULE SEE SCHEDULE DISCONTINUOUS END NOTES:
DISCONTINUOUS CONTINUOUS END CONTINUOUS END
FREE END SLAB REINFORCEMENT NOT SHOWN FOR CLARITY
NOTES: ELEVATION SECTION
1. AT INTERIOR SUPPORT (CONTINUOUS END) PROVIDE LARGER SIZE AND
NUMBER OF TOP AND BOTTOM BARS FROM ADJACENT SPAN.
2. NO SPLICE SHALL BE ALLOWED 2d FROM THE FACE OF THE SUPPORT TYPICAL DUCTILE MOMENT FRAME BEAM DETAIL FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or -AS SHOWN
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER DRAFTSMAN
S-400
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
NENIO SASITA
GLENDA MARCUELO R 0
W REPUBLIC OF THE PHILIPPINES
CROSSTIE DEPARTMENT OF PUBLIC WORKS
AND HIGHWAYS

350mm

45°
MAX.
A B C D OFFICE OF THE BUILDING OFFICIAL

H
10900 CECU CITY

d
10

.
IN
3100 4400 1400 2000

M
RECOMMENDING APPROVAL

REINF.
CONF.
Lo
HEAD STRUCTURAL DATE
2000

2000
LC-100x50x20x1.2mm RC GIRDER SECTION
(SEE SCHEDULE) 12mm Ø @ 0.30M O.C.

COLUMN TIESREINF.
JOINT
SPACE @ 0.60m O.C.
1.00 APPROVED:

AS
LoSCHEDULE
1

0.10
TRUSS - 1 (SEE DETAIL)
TRUSS - 1 (SEE DETAIL)

10Ø TEMPERATURE BARS


@ 0.30M O.C.
NOTES:
BUILDING OFFICIAL DATE

REINF.
CONF.
PROVIDE 20MM CLEAR CONCRETE COVER

FOR COL. BAR SPLICES

PER
E CONCRETE CANOPY DETAIL SEE TABLE OF MIN. LAP
3700

3700
SCALE 1:20 M
S4 SPLICE LENGTH OF COL.
REINFORCEMENT
CONCRETE SLAB ON ELEV=0.30 M
TYPICAL
FILL

SPLICE TIES
Ø12@100
12MM Ø TOP &
BOT.
BARS @ 0.30M O.C. B.W.

0.15
WELDED
TRUSS - 1 (SEE DETAIL)

TRUSS - 1 (SEE DETAIL)


13400

13400
REBAR 12MM Ø TOP & BOT. BARS
@ 0.30M O.C.

CANOPY DETAIL

REINF.
CONF.
E

Lo
SCALE 1:20 M
S4
4700

4700

REINF.
JOINT
LC - 100x50x20x1.2mm
SPACED @ 0.60m O.C.
L - 50X50X6mm TOP & L - 40X40X4mm

REINF.
BOTTOM CHORD MEMBERS WEB MEMBERS

CONF.
Lo
0.30
3000

3000
NOTES:
1. YIELD STRESS OF HOOPS = 60/40 KSI
0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 2. Lo = USE MAXIMUM COLUMN/SHEARWALL
DIMENSION, 1/6 CLEAR HEIGHT OR
450mm WHICHEVER IS GREATER.
3. NUMBER OF HOOP TIES SAME AS PER
3000 5900 2000 D TYPICAL TRUSS DETAIL COLUMN/SHEARWALL TIES SCHEDULE.

10900 S4 SCALE 1:30 M


COLUMN/SHEARWALL ELEVATION SHOWING
DOWELS AND TIES SPACING DETAIL
ROOF BEAM PLAN
SCALE 1:100

W
CROSSTIE

10
d

350mm MAX.
m
in
SCHEDULE OF REINFORCED CONCRETE GIRDERS

45°

H
FLOOR BEAM SECTION LONGITUDINAL REINFORCEMENTS WEB MAXIMUM SPACING OF
LEVEL MARK LOCATION RIGHT END SECTION BARS STIRRUPS REMARKS TIES IN LAP LENGTH (SMALLER BETWEEN
WIDTH DEPTH LEFT END SECTION MIDSPAN W OR 100mm)
LOCATION EACH FACE TENSION LAP SPLICE ONLY WITHIN
(B) (H) CONT. END DISCONT. END SECTION CONT. END DISCONT. END CENTER HALF OF CLEAR COLUMN HEIGHT.
(SEE TABLE OF MINIMUM LAP SPLICE JOINT HOOPS MUST BE SPACED AT "2Sh"
LENGTH OF COLUMN REINFORCEMENT) FOR THE DEPTH OF THE SHALLOWEST
TOP BARS 3 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø BEAM WHEN BEAMS WITH WIDTH > 43
2G - 1 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L. TIMES THE WIDTH OF THE COLUMN FRAME
BOT. BARS 2 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø OFFSET VERTICAL BAR INTO THE FOUR SIDES OF A COLUMN.
1:6 SLOPE MAXIMUM FOR ALL OTHER CONDITIONS, USE HOOPS
SPACED AT "Sh" ON CENTER.
TOP BARS 3 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø
2G - 2 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L. T / SLAB

JOINT HOOPS
SECOND FLOOR LEVEL

BOT. BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø


TOP BARS 3 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø
2G - 2A 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L.

COL. HOOPS

SCHEDULE)
BOT. BARS 2 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø

(SEE

Lo
H/4
TOP BARS 2 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø FOR COL. BAR SPLICES

Sh
SEE TABLE OF MIN. LAP
2G - 3 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L.

CLEAR HEIGHT OF COLUMN ("H")


SPLICE LENGTH OF COL.
BOT. BARS 3 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø REINFORCEMENT

(LOCATION OF COUPLERS)

SPLICE TIES
2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø

Ø12@100
TOP BARS

COLUMN TIES
2G - 4 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L.

H/2
BOT. BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø
TOP BARS 4 - 16mm Ø 2 - 16mm Ø 4 - 16mm Ø
2G - 5 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L.

St
BOT. BARS 2 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø

COL. HOOPS

SCHEDULE)
H/4
TOP BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø

(SEE

Lo
2G - 6 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L. T / SLAB
NOTES ON MECHANICAL COUPLERS:

Sh
BOT. BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 1. COUPLERS MUST BE LOCATED WITHIN
THE MIDDLE HALF OF THE CLEAR
TOP BARS 3 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø HEIGHT OF THE COLUMN
2G - 7 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L. 2. SUBMIT TEST RESULTS OF COUPLERS
FOR ENGINEERS' APPROVAL.
BOT. BARS 2 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø 3. AT LEAST 15% OF COUPLERS FOR
EACH SIZE OF REBAR MUST BE
TOP BARS 3 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø TESTED FOR TENSILE STRENGTH TEST
2G - 7A 200 450 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L.
BOT. BARS 2 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø
NOTES:
TOP BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø Sh = HOOP AND SUPPLEMENTARY CROSSTIE SPACING NOT TO EXCEED W / 4, 6db OF VERTICALS OR 150mm
RCG - 1 200 400 NONE 10MM Ø: 1@50mm, REST @ 100mmO.C. TO FREE END AND NEED NOT BE TAKEN LESS THAN 100mm
BOT. BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø St = COLUMN TIE SPACING, NOT TO EXCEED 16db OF VERTICALS, 48db OF TIES, W OR 150mm, WHICHEVER IS LESSER.
LEVEL

W = SMALLER DIMENSION OF COLUMN CROSS SECTION.


ROOF

TOP BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 1


Lo = LARGEST COLUMN DIMENSION, 6 OF CLEAR HEIGHT OR 450mm, WHICHEVER IS GREATER.
RG - 1 200 400 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L. H = CLEAR HEIGHT OF COLUMN.
BOT. BARS 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø
TOP BARS 3 - 16mm Ø 2 - 16mm Ø 3 - 16mm Ø 3 - 16mm Ø TYPICAL MOMENT FRAME
RG - 2 200 400 NONE 10MM Ø: 1@50mm, 10@100mm, 5@150mm, REST @ 300mm O.C. TO C.L.
BOT. BARS 2 - 16mm Ø 3 - 16mm Ø 2 - 16mm Ø 2 - 16mm Ø CONCRETE COLUMN SPLICE DETAIL
MATERIALS SPECIFICATION: fc' = 20.7 MPa (3,000 psi) fy = 414 MPa (60,000 psi)

FOR PRESENTATION
SEAL R.A.9266 Section 33 PROJECT TITLE: APPROVED BY: SHEET CONTENT: PROJECT IN CHARGE SHEET NO. :
Drawing and specifications and other
contract documents signed, stamped or -AS SHOWN
sealed, as instruments of service, are the JUN-NINE BINAGATAN
-
SOON TO BE AN ARCHITECT
intellectual property and documents of
the architect, whether the object for which
they are made is executed or not, it shall
be unlawful for any person to duplicate or
to make copies of said documents for use
A PROPOSED 2-STOREY RESIDENTIAL BUILDING AR. MARK A. BODIONGAN
OWNER DRAFTSMAN
S-500
REG. NO.: - DATE : -
JNGRC, GROUP OF ARCHITECTS in the repetition of and for other projects

Dionisio Jakosalem St, Cebu City, 6000 Cebu


PTR NO. : -
ISSUED AT: CEBU CITY
DATE :-
TIN : -
of building, whether executed partly in
whole, without the written consent of
architect or author of said documents. LOCATION: Dionisio Jakosalem St, Cebu City, 6000 Cebu ADDRESS: Dionisio Jakosalem St, Cebu City, 6000 Cebu
NENIO SASITA
GLENDA MARCUELO R 0