Laboratory Equipments PDF
Laboratory Equipments PDF
Laboratory Equipments PDF
PHS type digital acidity meter is an instrument used to measure pH value in laboratory. It
has dual functions of pH and MV. E201 composite electrode is used, which has fast
reaction and good stability. This series of instruments are widely used in scientific
research, teaching, agriculture and many other disciplines and fields.
The hydrogen ion activity in aqueous solution is converted into electric energy by the
sensor (pH composite electrode), and the electric energy is input to the instrument, which
is converted into digital display by a / d after operational amplifier and current detection.
The above electric energy accords with Nernst equation.
Technical parameter
Page 17 of 41
Driven by nanoheat world-class thermal technology, no mechanical heating
components, dry burning, no electromagnetic interference and harm,
-Ultra fast heating technology enables the temperature to rise at a rate of 5°C
With the increase of the velocity, the surface temperature of the plate is uniform,
and the temperature difference is 1-3°C The liquid temperature difference can
be accurate to 0.1 - 0.5 , and it only takes 8 minutes to raise 450
-LED display, can set the specified temperature, built-in temperature probe and
external temperature probe, can switch freely.
-Stable mixing performance, DC motor, low noise, long life, stable low speed,
strong high speed, digital speed display, stepless speed regulation;
-Free from magnetic interference and harm: making it a good choice for medical
and laboratory use
-Suitable for most electrical appliances: glass, ceramics and metal utensils
Technical parameter
Page 18 of 41
Frequency: 50/60HZ
Temperature range room temperature 450
Temperature control model LED display setting
Temperature test inner control and outer change
Control precision ±0.5
Stirrer driver ND motor output 9W
Speed scope 0 2500rpm
Speed control digital display adjust
Maximum stirrer 5L
Weight: 5kg
Working plate size 200×200mm
Plate material Ceramic panel
Stirrer size
Product dimensions 310×120×200mm
Page 19 of 41
Technical parameter
-The ultra fast heating technology can make the surface temperature increase at
5 per second ° The speed of C increases,
-LED display, can set the specified temperature, PT100 external probe, can be
accurate to 0.1 - 0.5 ,
Page 20 of 41
-Stable mixing performance, DC motor, low noise, long service life, stable low
speed, strong high speed, digital speed display, stepless speed regulation,
-Free from magnetic interference and harm: make it a good choice for medical and
laboratory use,
-Suitable for most containers: round bottom, flat bottom, glass, ceramic and metal,
Speed control: digital display of speed and speed regulation without pole
Working dimension: table top 200 × 200mm, arc diameter 153mm, depth 60mm
Page 21 of 41
Technical parameter:
*The temperature control system adopts the technology of micro-computer single chip
microcomputer and PID constant temperature self-tuning adjustment to ensure the
constant temperature fluctuation.
*Double screen high brightness digital tube display, temperature display is clear.
*High quality stainless steel liner, four corner arc design, corrosion resistance, oxidation
resistance, easy to clean.
*High quality cold rolled steel shell, electrostatic spray surface, anti rust, the overall design
is beautiful and generous, suitable for laboratory color matching.
*Advanced internal circulation and external circulation system, the internal circulation
makes the temperature uniform and stable, the external circulation pump outputs 6L / min,
13L / min flow constant temperature liquid to establish the second constant temperature
field outside the machine, and can also be used as a cold source to cool the external
experimental container.
*Air cooled hermetic compressor is adopted for refrigeration, with fast cooling speed, low
noise and convenient operation. The power supply is 220 V and 50 Hz.
*Low temperature thermostat manufacturer, touch button, can freely set high temperature,
and constant temperature holding time, timing time is 1 ~ 9999 min.
Page 22 of 41
*Over temperature alarm protection, the user can set the over temperature alarm range
freely.
Page 23 of 41
Power supply: AC220V/50Hz
JC electronic balance is strictly in accordance with the national standard GB/T 26497-
2011 production, four Angle bias load error, repeatability error than the national standard
is one times smaller! Can meet the requirements of customer experiment analysis, can
meet the requirements of enterprise QS certification.
This series of analytical balance adopts excellent wireless sensor, no button, easy
wave above the sensor window can control the peeling, calibration function, avoid s
ample residues corrode the button, prolong the service life of the product;
For precision balance calibration, the induction window function can effectively prev
ent the vibration caused by direct contact with the balance button, so that the calib
ration is more accurate;
Built-in RS232 standard interface, in line with GLP standard, can be connected to
printers, computers under the weighing hook, to meet the requirements of large vol
ume weighing;
This series of analytical balance products are cost-effective, with unit conversion, c
ounting, percentage and other functions. Linear multi-point calibration ensures more
Page 24 of 41
accurate and reliable experimental data. Adjustable range of zero tracking and auto
matic peeling, to ensure more convenient use.
Technical parameter:
4. Weight: 8kg
For industrial and mining enterprises, colleges and universities, biological products, food
processing, scientific research institutions, medical units and all kinds of laboratories, as
non-flammable, explosive and non-volatile articles of drying, baking, wax melting,
disinfection, sterilization.
1. The inside of the box is made of mirror stainless steel by argon arc welding, and the
outside of the box is made of high quality steel plate, which is beautiful and novel in
shape.
Page 25 of 41
3. The hot air circulation system is composed of a fan that can run continuously at high
temperature and an appropriate air duct to improve the temperature uniformity in the
working room.
4. The temperature control system of platinum resistance sensor makes the temperature
control more accurate and the operation more convenient.
6. CCC certification in line with the double-layer toughened glass observation window,
safer, more clear observation box sample.
AC220V±10% 50Hz±1Hz
Temperature control range: RT+10~200
precision: 0.1, ±1
5. Power: 1240W
7. Water Bath :
Page 26 of 41
Temperature adjustment adopts PID technology, digital display.
Advanced PTC heating element, fast heating speed, long service life, no combustion,
safe and reliable. The water bath heats evenly and runs reliably.
The surface of the device is made of stainless steel with strong corrosion resistance.
8. Spectrophotometer
Page 27 of 41
Page 28 of 41
Power supply: AC220V/50Hz
9. Fume Hood fume cabinet with built-in chemical storage cabinet (at the bottom)
with ducting (1 unit); explosion-proof.
1. Main frame: the left and right side plate, front plate, back plate, top plate and lower
cabinet are made of 1.0 mm thick Maanshan Iron and steel grade I cold-rolled galvanized
steel plate. The material is cut by automatic numerical control laser cutting machine. The
bending is made by automatic numerical control bending machine. The spraying surface
is automatically sprayed by epoxy resin electrostatic assembly line.
2. Lining plate / deflector: solid core anti Beite plate (5mm thick) with good anti-corrosion
and chemical resistance. The fixing parts of the deflector are made of PP high-quality
materials and are integrated into one.
3. Mobile window: 5mm high-quality tempered glass, door opening height is 700mm, free
lifting, sliding device of sliding door adopts elevator counterweight structure, stepless
random stop, sliding door guiding device is made of anti-corrosion polyvinyl chloride
material. The handle of the sliding door is made of PP, and the side of the sliding door is
Page 29 of 41
wrapped with anti-corrosion plastic. The opening and closing of the sliding door are
equipped with rubber buffer device.
4. In front of the fume hood are all glass windows with good visual range. The material of
the deflector is consistent with that of the lining, and the deflector bracket is composed of
non-metallic materials.
5. Lower cabinet: solid core physicochemical board (12.7mm thick) is adopted for the table
top, which is acid and alkali resistant, impact resistant and corrosion resistant.
Formaldehyde reaches E1 level standard, and the back has indelible back label.
6. Connections: all internal connections shall be concealed and corrosion resistant. There
are no exposed screws.
External connections are chemical resistant, stainless steel parts wrapped in polyvinyl
chloride and non-metallic materials.
7. Exhaust outlet: the exhaust outlet is round and connected by sleeve to reduce gas
disturbance.
8. Cabinet size w * D * H: external 1500x850x2350mm, internal space 1300x650x850mm
Other lining materials of the fume hood. Other materials inside the fume hood are sprayed
with epoxy resin on both sides. They are resistant to acid, alkali and organic solvent
corrosion, and have no bare metal or materials that cannot resist corrosion and fire.
The fume hood is equipped with imported one-time molding PP small cup slot, acid and
alkali resistance, corrosion resistance.
The fittings inside the fume hood (single port seven character faucet) are made of brass
and installed inside the fume hood.
Fume hood control panel: LCD control panel (can be set to adjust the speed freely, can
adapt to most similar products on the market).
Fume hood lighting: LED waterproof lamp, quick start type, installed on the top of fume
hood. The lighting device has a safety glass panel on it and is sealed with the cabinet body.
Page 30 of 41
Rotary evaporator is a new generation of intelligent rotary evaporator developed by our
company on the basis of absorbing international technology. It can be heated at constant
temperature and rotated under negative pressure to form a thin film, evaporate efficiently,
and then recover the solvent after cooling. It is especially suitable for crystallization of
thermal sensitive materials and solvent recovery. It is used in biology, medicine and
chemical industry, It is an important instrument and equipment for scientific research and
production in food industry.
The evaporation bottle rotates at a constant speed, and the water bath is heated at a
constant temperature. Under this condition, the material forms a large area uniform film
on the inner wall of the evaporation bottle and evaporates rapidly. Under the vacuum
condition, the evaporation efficiency can be improved (the vacuum device needs to be
connected). The solvent vapor is cooled into liquid (the cooling device needs to be
connected) when it passes through the glass condensing coil and recycled in the
collection bottle.
This series of products need to be equipped with vacuum devices (circulating water type,
rotary type, diaphragm type and other vacuum pumps) and cooling circulating devices to
form a system device.
1. Sealing PTFE material, good sealing, corrosion resistance and wear resistance
3. Clear display of control and data information interface, speed digital display
6. Double reflux, integrated standard port condensing pipe sleeve with ball grinding
collecting bottle.
Page 31 of 41
7. Valve type feeding sleeve connected with Teflon pipe
control accuracy ± 1
Page 32 of 41
Temperature range: - 80-500
Accuracy class: 1.0 / 1.5,
Indication part of thermometer: (expressed according to the outer diameter of
Page 33 of 41
Power supply: AC220V/50Hz
Page 34 of 41
Conductivity meter is a precision instrument used to measure the conductivity of various
liquid media in laboratory. It is widely used in many disciplines and fields such as
scientific research, teaching, industry, agriculture and so on. The conductivity of high
purity water or high conductivity water can be accurately measured with 0.1 and 10
constant conductivity electrodes.
Page 35 of 41
Storage contents: number, measurement value, measurement unit and temperature
value
Page 36 of 41
Page 37 of 41
Page 38 of 41
Test items: total nitrogen, total phosphorus, COD, ammonia nitrogen
Scope of application: suitable for rapid quantitative determination of total nitrogen, total
phosphorus, COD and ammonia nitrogen in surface water, groundwater, industrial
wastewater and domestic sewage
Instrument features:
2. The instrument has built-in working curve, so it does not need to configure standard
solution, and only needs to use matching reagent to carry out zero point correction, which
can realize rapid quantitative determination of samples
3. Through the special prefabricated reagent, the preparation time of reagent is greatly
shortened, and the operation is simple and convenient. After adding the special reagent
package to develop the color, only zero point correction is needed to realize the
determination of the measured substance
5. The instrument has built-in standard UV-Vis spectrum width method, which can build its
own working curve and be used flexibly to meet the needs of different customers
Page 39 of 41
Spectral bandwidth: 2 nm
Photometric accuracy: ± 0.5%T
Photometric repeatability: 0.2% t
Wavelength range: 200-1000nm
Wavelength accuracy: ± 1nm
Wavelength repeatability: 0.2 nm
Detection items: residual chlorine, turbidity, fluoride, nitrite nitrogen, iron, hexavalent
chromium, sulfide, ammonia nitrogen, ozone, etc
Instrument features:
3. Display mode: 4.7-inch large liquid crystal Chinese display is used to directly display
the measured concentration
4. Built in curve: the instrument has built-in working curve, which can realize rapid
quantitative determination of samples without configuring standard solution
Page 40 of 41
5. Measurement method: the color development and measurement of the sample are the
same closed vessel (cylindrical), without transfer, so as to improve the detection
accuracy
6. Stand alone software: the instrument has many functions such as measuring, setting,
recording, saving and data statistical processing
7. Online software: it can input the sample name, tested items, testing institutions, testing
personnel and other information, and export data in Excel format
8. Data interface: USB interface and COM interface are set to support data management
and instrument control
9. Power supply mode: AC / DC dual-purpose, the instrument has built-in lithium battery
to meet the emergency and on-site monitoring, at the same time, it has the power self
diagnosis function to automatically prompt the power shortage
11. Special reagent kit: equipped with special prefabricated reagent, it can shorten the
preparation time of reagent, and is easy to operate and use
Power supply:
1. AC power supply: 220 v ± 22V 50Hz ± 1Hz
2. Built in rechargeable battery: 7.2v1.0ah
Operating environment: 5 ~ 40
Page 41 of 41