AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
Table of Contents
Section Title Page
1. Description
2. Installation
3. Operation
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
Section 1 Description
1.1 Introduction
Information in this section consists of product description, design features and specifications for the
AA38-3xx Series Local ICS Loop. All derivative product information shall be contained in the applicable
manual supplement, which may be obtained from NAT as required.
The AA38-300 Local ICS Loop provides intercom functions for eight users with operation in HOT MIC or
VOX mode. A switch-selectable NAT or Andrea tie line allows connection to multi-unit systems and radio
or music can be connected at the AUX input.
The AA38-301 Local ICS Loop is functionally identical to the AA38-300 but has two fully independent
AA38-300 PCB assemblies mounted inside the enclosure and can therefore provide the same intercom
functions for sixteen users.
The AA38-3xx Series remote bulkhead mounted units contain all the circuitry to support a wide variety of
ICS Loop applications, particularly isolation/ICS amplifier use, where the output is required to be headset
or line level.
The compact size and low weight of the AA38 allows mounting in restricted locations and the mapped
interconnect makes installation simple to carry out.
Built-in LED annunciators speed up airframe trouble-shooting by providing an indication of power to the
AA38 and VOX operation.
Level adjustments are provided for ICS level and AUX Input level.
1.4 Specifications
Input Power
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
Input Signals
Output Signals
Rated Level Headset output 7.7V rms or 100 mW (20 dBm) into 600
Circuitry Type Balanced output for high common mode noise rejection
Audio Noise Level >60 dB down from rated output (without signal)
Output Regulation <10% distortion / 3 dB max. of rated output power at 400% and
75% of rated load
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
AA38-300 AA38-301
Humidity 95%
Qualification of the AA38-300 Local ICS Loop was completed in accordance with
DO-160C Env. Cat. B4-CA[BMN]XXXXXXZBABBTZXXX.
Note: Refer to Environmental Qualification Form located in Section 2 of this Manual for complete details
of the environmental categories.
Note: Applicable to AA38-300 and AA38-301 units serial number 3000 and up.
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
Section 1 ends
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
Section 2 Installation
2.1 Introduction
Information in this section consists of unpacking and inspection procedures, installation procedures, post-
installation checks and installation drawings for the AA38-3xx Series Local ICS Loop.
Unpack the equipment carefully and locate the warranty card. Inspect the unit visually for damage due to
shipping and report all such claims immediately to the carrier involved. Check that all items listed below
are present before proceeding and report any shortage immediately to your supplier:
- Warranty Card
- Certificate of Conformity or Release Certification
2.2.1 Warranty
All Northern Airborne Technology Ltd. products are warranted for 2 years from date of installation by an
authorized NAT dealer, to be free of defects in workmanship or performance. This warranty covers all
materials and labour, but is exclusive of any transport to deliver the defective unit to and from NAT or its
designated warranty repair center, or any labour to remove or re-install the defective unit in the aircraft.
Contact NAT for any questions regarding this warranty, its applicability to your units and/or for return
authorization. NAT is the final arbitrator concerning warranty administration. Units which have been
physically damaged, burned, immersed in water or otherwise abused beyond the scope of normal use will
not be considered for warranty. WARRANTY IS VOID UNLESS THE PRODUCT IS INSTALLED BY AN
AUTHORIZED NAT DEALER. Product for which a warranty card is not returned shall be warranted from
date of manufacture.
Maintenance of the AA38-3xx Series Local ICS Loop is ‘on condition’ only. Periodic maintenance of this
product is not required.
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
2.4.1 Cautions
CAUTION:
In all installations, use shielded cable exactly as shown and ground as
indicated. Significant problems may result from not following these guidelines.
All wire shall be selected in accordance with the original aircraft manufacturer's Maintenance Instructions
or AC43.13-1B Change 1, Paragraphs 11-76 through 11-78. Unshielded wire types shall qualify to
MIL-W-22759 as specified in AC43.13-1B Change 1, Paragraphs 11-85, 11-86, and listed in Table 11-11.
For shielded wire applications, use Tefzel MIL-C-27500 shielded wire with solder sleeves (for shield
terminations) to make the most compact and easily terminated interconnect. Follow the connector map in
Section 2.7 as required.
Allow 3" from the end of the shielded wiring to the shield termination to allow the connector hood to be
easily installed. Reference the interconnect drawing in Section 2.7 for shield termination details. Note that
the hood is a "clamshell" hood, and is installed after the wiring is complete. Aircraft harnessing shall
permit the unit to be lowered from the panel for easy access to all side adjustments. Do NOT mount the
unit until all adjustments have been performed.
Maintain wire segregation and route wiring in accordance with the original aircraft manufacturers
Maintenance Instructions.
Unless otherwise noted, all wiring shall be a minimum of 22 AWG, except power and ground lines, which
shall be a minimum of 20 AWG. Reference the Interconnect drawing for additional specifications. Check
that the ground connection is clean and well secured, and that it shares no path with any electrically noisy
aircraft accessories such as blowers, turn and bank instruments or similar loads. Power to this unit must
be supplied from a separate circuit breaker or fuse (fast blow), and not attached to any other circuit
breaker without additional protection. Verify that the selected circuit breaker size and wire gauge are
adequate for the installation using the techniques specified in AC43.13-1B Change 1, Paragraphs 11-47
through 11-51 and 11-66 through 11-69.
The AA38-300 can be configured for up to three NAT Tie Lines, or one Andrea Tie Line and each
‘section’ of the AA38-301 can be configured separately for these options.
The switches that determine the installation configuration are ICS GAIN switches 1, 2, 3, and 4, and ICS
MODE switches C1/C2 and C3/C4, accessible through the left hand side of the unit. Refer to Figures 1, 2
and 3 to determine the proper switch settings.
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
The rocker switches used to configure the AA38 for the appropriate tie line option are visible through the
ICS MODE opening(s) in the side of the unit. The diagrams below show one set of rocker switches for the
AA38-300 and two for the AA38-301.
OR
Figure 2: ICS MODE Switch positions for Figure 3: ICS MODE Switch Positions
1, 2, or 3 NAT ICS Tie Lines for ANDREA Tie Lines
Table 1
Mode and Switch Positions
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
Do not attach the AA38-3xx until the following conditions are met.
Power up the aircraft’s systems and confirm normal operation of all functions of the AA38-3xx. Refer to
Section 3 (Operation) for specific operational details.
a) Check for correct radio audio and adjust for acceptable level.
b) Run through all installed functions and check the ICS functions for all users.
c) Check preset adjustments are completed before aircraft departure. Refer to Section 2.5 for
details of adjustments.
Upon satisfactory completion of all performance checks, make all required log book entries, electrical
load, weight and balance amendments and other documentation as required by your local regulatory
agency before releasing the aircraft for service.
The unit is shipped from the factory with all internal adjustments set to the normal test levels. Once
installed in the aircraft, it may be desirable to change some of these settings to best suit the local
operating environment. The internal adjustments are located along the right side of the unit.
Adjust ICS VOL and AUX VOL to desired levels. Clockwise rotation of these controls will increase audio
volume level.
Setting the ICS VOX control fully clockwise sets the AA38 to ‘live’ mode. Adjusting it counter clockwise
sets the level which activates the VOX mode.
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
AA38-IKC consists of
AA38-301
AA38\301\403-0 1.00 16 Place Local ICS Loop Interconnect 2067 and up
AA38\301\403-1 1.00 16 Place Local ICS Loop Interconnect 2067 and up
AA38\301\405-0 1.00 16 Place Local ICS Loop Connector Map 2067 and up
AA38\301\922-0 1.02 16 Place Local ICS Loop Mechanical Installation 2067 and up
The document reference is online, please check the correspondence between the online documentation and the printed version.
&RQILGHQWLDODQG3URSULHWDU\WR1$7
The document reference is online, please check the correspondence between the online documentation and the printed version.
&RQILGHQWLDODQG3URSULHWDU\WR1$7
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
The document reference is online, please check the correspondence between the online documentation and the printed version.
AA38-3xx Series Local ICS Loop
SM37 Installation and Operation Manual
Section 3 Operation
3.1 Introduction
Information in this section consists of functional and operational procedures for the AA38-3xx Series
Local ICS Loop.
The AA38-300 provides intercom functions for eight users (sixteen for the AA38-301) with operation in
HOT MIC or VOX mode. A switch-selectable NAT or Andrea tie line allows connection to multi-unit
systems and an AUX input allows radio or music to be connected to the AA38.
The AA38-3xx Local ICS Loop has no normal user operational aspects. During installation, or if the unit
has been exchanged, it may be a requirement to change internal adjustments. This should be done only
by fully qualified personnel.
Section 3 ends