NVS 345 50 110 120 - 50062 - en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

SENSORS FOR FOOD AND BIOPHARMA.

50062 / 3.4 / 2021-09-20 / MU / EU

Product Information NVS-50, -110, -120, -345 FOOD

Conductive Multilevel Sensor


Application/intended use NVS-345/...B NVS-50/...N
· Point level measurement in aqueous, conductive media in tanks and pipes with
minimum conductivity. The conductivity depends on the evaluation device:
1 μS/cm when using external evaluation units, e.g. VNV series or ZNV-Z, and
10 μS/cm when using the internal level transmitter MNV-1C.

Application examples
· Empty/full indication in tanks
· Level control in tanks
· Overfill protection in dosing systems

Hygienic design/process connection (NVS-345 and NVS-50 only)


· Hygienic and easy-to-sterilize measuring point
· Elastomer-free sealing system for gap-free sensor installation without
dead space
· CIP/SIP cleaning up to 143 °C/120 min
· Sensor made entirely of stainless steel and PEEK; PFA coating
· Adapters for all standard process connections
· Product-contacting parts are compliant with EU Regulation 10/2011 and FDA
(NVS-345 and NVS-50)
NVS-120/...B NVS-110.SEIL/...

Special features/advantages
· Defined position of the cable entry (NVS-345 only)
· Available with or without an integrated level transmitter MNV-1C
· Choice of different electrical connections
· Electrodes can be shortened and bent as required

Options/accessories
· Version with rope electrodes available (NVS-110.SEIL)

Selection of the right sensor type

Coating:
For foamy, adhesive (e.g. yogurt) and/or wetting media (e.g. alkaline solutions),
we suggest using a sensor with a coated electrode. Sensors with an uncoated
electrode are recommended for aqueous, non-adhesive and non-wetting
media. If rod lengths are greater than 500 mm, the coated version should be
used since the electrodes may come into contact with each other and lead to
incorrect readings.
FOOD Technical data 2

Technical data
Type NVS-50 NVS-345 NVS-110 NVS-120
Process connection Milk pipe DIN 11851 Thread G1"; hygienic Thread G1" Thread G1½"
DN50; hygienic standard; standard;
not hygienic not hygienic
Electrodes
Quantity Max. 5 Max. 4 Max. 4 Max. 5
Length [mm] 200; 500; 850; 1000; 200; 500; 850; 1000; 200; 500; 850; 1000; 200; 500; 850; 1000;
1500; 2000 1500; 2000 1500; 2000 1500; 2000
Diameter 4 mm (8 mm optional) 4 mm (8 mm optional) 4 mm (8 mm optional) 4 mm (8 mm optional)
Temperature ranges*
Ambient -10...+60 °C -10...+60 °C -10...+60 °C -10...+60 °C
Process 0...110 °C 0...110 °C 0...90 °C 0...90 °C
CIP/SIP cleaning 143 °C/120 min. 143 °C/120 min.
Process pressure Max. 10 bar Max. 10 bar Max. 10 bar Max. 10 bar
“SEIL”(rope) option:
Max. 1 bar
Tightening torque - 10...20 Nm - -
Materials
Connecting head Stainless steel (1.4305) Stainless steel (1.4305) PP hard plastic PP hard plastic
(Threaded) connector Stainless steel (1.4305) Stainless steel (1.4305) PP hard plastic PP hard plastic
Electrodes Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404)
Ropes/ Stainless steel (1.4401)/
rope weights - - Stainless steel (1.4404) -
Insulator PEEK PEEK - -
Coating
(electrodes) PFA PFA PFA PFA
Coating (rope) - - Polyamide PA6 -
Rope electrodes
available No No Yes (NVS-110.SEIL) No
Electrical connection M12 plug connection (1.4305)
Cable gland M16 x 1.5
Protection class IP 69 K (with M12 plug connection)
IP 67 (with cable gland)

*) When using the integrated level transmitter MNV-1C, please note the temperatures specified below in the technical data
of the level transmitter.

Technical data of level transmitter MNV-1C


Temperature Operation -10...+60 °C
Storage -20...+60 °C
Humidity Without condensation 0...95 % r. F.
Supply voltage 15...36 V DC
Electrode E Voltage 1.5...2 V AC/300 Hz, no DC signal
Adjustable sensitivity MNV-1C 0.1; 1; 10; 100 kΩ
Output Short-circuit-proof Active 50 mA
Delay Fixed 0.5 s
Switching function Selectable min./max. MNV-1C jumper
3 Electrical connection FOOD

Explanation of switching states Configuration of level transmitter MNV-1C

Full indicator: The output is active when immersed 3 function 4 sensitivity 0.1 kΩ sensitivity 1 kΩ
Empty indicator: The output is active when not immersed “full”

Level transmitter MNV-1C


function sensitivity 10 kΩ sensitivity 100 kΩ
1: LED sensor 1
“empty”
(lights up when the sensor 2
is immersed in the medium,
regardless of the switching
function)
2: Terminal block 3
3: Empty/full jumper Standard setting on delivery
4: Sensitivity jumper 4 3: full
4: 10 kΩ

Setting up level transmitter MNV-1C

· Connect the supply voltage.


· Set the switching function. See the adjacent configuration description.
· Set the lowest sensitivity. See the adjacent configuration description.
· Wet the sensor with the least conductive medium.
· If the output switches, the selected sensitivity can be retained and the calibration is finished. If the output does not
switch, please continue as follows:
· Increase the sensitivity until the output switches. Once this happens, calibration is finished.

Electrical connection with MNV-1C Electrical connection


Terminal block Terminal block Top view

1 2 3 4 5 1: Ground (sensor) 4 1 3 2 5
2: Electrode (sensor)
3: Active output
4: Supply voltage
5: 15...36 V DC

M12 connector M12 connector

General setup procedure

· If necessary, cut the electrodes to the required lengths. In doing so, ensure that the compound between the rod and the
thread connector is not strained excessively. If using coated electrodes, do not damage the insulation of the rod part
that remains on the sensor.
· Strip 5 mm of insulation off the tip of insulated rods.
· Screw the sensor into the sleeve and connect as shown in the wiring diagram. Do not damage the coating when insert-
ing the sensor into the sleeve.
FOOD Dimensional drawings 4

NVS-345 NVS-345.2/M NVS-50 NVS-50.2/M

1 2 3 4 M

1 4 2
(5/3)

1 5 2

NVS-110 / NVS-110.SEIL NVS-110.2/M NVS-120 NVS-120.2/M

This sensor does not This sensor does not This sensor does not This sensor does not
conform to hygienic conform to hygienic conform to hygienic conform to hygienic
requirements. requirements. requirements. requirements.
5 Notes FOOD

Note on material conformity as per European Regulation 1935/2004 or 10/2011

· The plastics used in the NVS-345 and NVS-50 sensors are materials approved by European Regulations 1935/2004
and 10/2011 for contact with food.
· The materials of the NVS-110, NVS-110.SEIL and NVS-120 sensors are not in accordance with the European regulations
specified above.

Mounting instructions

· When installing the NVS-345, only use Negele weld-in systems to ensure proper functioning of the measuring point.
· When screwing in the sensors, do not exceed the maximum permissible torque (see the technical data on page 2).
· If the tank wall is being used as the reference electrode (only possible with NVS-345 and NVS-50), ensure that the sen-
sor process connection makes good electrical contact with the pipe and tank wall. Do not use insulating sealants such
as Teflon. The tank wall must be made of metal in this case.
· When installing the sensors, ensure that the electrode emerges from the medium when it is drained.
· When tightening and loosening the sensor, only use the wrench flats provided this purpose, never the connecting
head.

Cleaning/Maintenance Transport/Storage

· When using a pressure washer, do not point the nozzle · No outdoor storage
directly at the electrical connections. · Store in an area that is dry and dust-free
· Do not expose to corrosive media
· Protect against solar radiation
· Avoid mechanical shock and vibration
Reshipment · Storage temperature 0...40 °C
· Relative humidity max. 80%
· Sensors and process connection must be clean and must
not be contaminated with hazardous media and/or heat-
conductive paste. Note the cleaning information!
· To avoid damage of the equipment, use suitable trans- Standards and guidelines
port packaging only.
· Compliance with the applicable regulations and direc-
tives is mandatory.

Notice on conformity

Applicable guidelines: Disposal


· Electromagnetic Compatibility Directive 2004/108/EC
· The CE label confirms compliance of this product with · This instrument is not subject to the WEEE directive
the applicable EC directives. 2002/96/EC and the respective national laws.
· You have to guarantee the compliance of all guidelines · Give the instrument directly to a specialized recycling
applicable for the entire equipement. company and do not use the municipal collecting
points.
FOOD Order code 6

Order code for rope sensors

NVS-110.SEIL (Head diameter 55 mm of plastic with G1" process connection and rope electrodes)

Electrode 1

[m] (lengths in m)
Electrode 2
(selection options: see Electrode 1)

Electrode 3
(selection options: see Electrode 1, evaluation unit not possible)

Electrode 4
(selection options: see Electrode 1, evaluation unit not possible)

Electrode 5
(selection options: see Electrode 1, evaluation unit not
possible)

Evaluation unit / level transmitter


X (without)
M (integrated in the head; only for 2 electrodes)
Open circuit alarm
(only possible with external evaluation unit)
X (without)
D (with open circuit resistance, only possible
with 2 electrodes)
Electrical connection
X (cable gland M16x1.5)
M12 (M12 connector 1.4305)

NVS- 110.SEIL / 10 / 8/ X/ X/ X/ X/ X/ M12


7 Order code FOOD

Order code for standard multilevel sensors

NVS
-345 (Head diameter 55 mm of stainless steel with CLEANadapt G1" hygienic process connection)
-110 (Head diameter 55 mm of plastic with G1" process connection)
-120 (Head diameter 55 mm of plastic with G1½" process connection)
-50 (Head diameter 55 mm of stainless steel with dairy flange DN50 as per DIN 11851)

Electrode 1
200N (uncoated 200 mm, diameter 4 mm)
200N-8 (uncoated 200 mm, diameter 8 mm)
200B (coated 200 mm, diameter 4 mm)
200B-8 (coated 200 mm, diameter 8 mm)
500N (uncoated 500 mm, diameter 4 mm)
500N-8 (uncoated 500 mm, diameter 8 mm)
500B (coated 500 mm, diameter 4 mm)
500B-8 (coated 500 mm, diameter 8 mm)
850N (uncoated 850 mm, diameter 4 mm)
850N-8 (uncoated 850 mm, diameter 8 mm)
850B (coated 850 mm, diameter 4 mm)
850B-8 (coated 850 mm, diameter 8 mm)
1000N (uncoated 1000 mm, diameter 4 mm)
1000N-8 (uncoated 1000 mm, diameter 8 mm)
1000B (coated 1000 mm, diameter 4 mm)
1000B-8 (coated 1000 mm, diameter 8 mm)
1500N (uncoated 1500 mm, diameter 4 mm)
1500B (coated 1500 mm, diameter 4 mm)
2000N (uncoated 2000 mm, diameter 4 mm)
2000B (coated 2000 mm, diameter 4 mm)
2500N (uncoated 2500 mm, diameter 4 mm)
[mm]N Special length, uncoated
[mm]B Special length, coated
[m] (length in m; only for NVS-110.SEIL)
Electrode 2
(selection options: see Electrode  1)

Electrode 3
(selection options: see Electrode  1, evaluation unit not possible)

Electrode 4
(selection options: see Electrode  1, evaluation unit not possible)

Electrode 5
(not for NVS-345, selection options: see Electrode  1, evaluation
unit not possible)

Evaluation unit / level transmitter


X (without)
M (integrated in head; only for 2 electrodes)
Open circuit monitoring
(only possible with external evaluation unit)
X (without)
D (with open circuit resistance, only possible with
2 electrodes)
Electrical connection
X (cable gland M16x1.5)
M12 (M12 connector 1.4305)

NVS- 345 200B/ 500B / 850B / 850B / X/ X/ X/ M12


FOOD Product Information NVS-50, -110, -120, -345 8

Accessories

Instead of the integrated level transmitter, standard multilevel sensors can also be used with external devices for
installation on DIN rails, for example. The full selection of external evaluation units, the technical data and the order
code can be found in the „Evaluation units for conductive multilevel sensors“ product information.

Overview of the evaluation units for conductive multilevel sensors for DIN-rail installation

VNV-E VNV-D ZNV-Z VNV-V VNV-S VNV-WEV VNV-WD

Advice

For level measurement according to German Water Management Act, please use the separate product information
NVS-146.w, NVS-116.2w, NVS-345.2w.

Notes

NEGELE MESSTECHNIK GMBH Phone +49 (0) 83 33 . 92 04 - 0 Tech. Support:


Raiffeisenweg 7 Fax +49 (0) 83 33 . 92 04 - 49 [email protected]
87743 Egg an der Guenz [email protected] Phone +49 (0) 83 33 . 92 04 - 720

You might also like