NVS 345 50 110 120 - 50062 - en
NVS 345 50 110 120 - 50062 - en
NVS 345 50 110 120 - 50062 - en
Application examples
· Empty/full indication in tanks
· Level control in tanks
· Overfill protection in dosing systems
Special features/advantages
· Defined position of the cable entry (NVS-345 only)
· Available with or without an integrated level transmitter MNV-1C
· Choice of different electrical connections
· Electrodes can be shortened and bent as required
Options/accessories
· Version with rope electrodes available (NVS-110.SEIL)
Coating:
For foamy, adhesive (e.g. yogurt) and/or wetting media (e.g. alkaline solutions),
we suggest using a sensor with a coated electrode. Sensors with an uncoated
electrode are recommended for aqueous, non-adhesive and non-wetting
media. If rod lengths are greater than 500 mm, the coated version should be
used since the electrodes may come into contact with each other and lead to
incorrect readings.
FOOD Technical data 2
Technical data
Type NVS-50 NVS-345 NVS-110 NVS-120
Process connection Milk pipe DIN 11851 Thread G1"; hygienic Thread G1" Thread G1½"
DN50; hygienic standard; standard;
not hygienic not hygienic
Electrodes
Quantity Max. 5 Max. 4 Max. 4 Max. 5
Length [mm] 200; 500; 850; 1000; 200; 500; 850; 1000; 200; 500; 850; 1000; 200; 500; 850; 1000;
1500; 2000 1500; 2000 1500; 2000 1500; 2000
Diameter 4 mm (8 mm optional) 4 mm (8 mm optional) 4 mm (8 mm optional) 4 mm (8 mm optional)
Temperature ranges*
Ambient -10...+60 °C -10...+60 °C -10...+60 °C -10...+60 °C
Process 0...110 °C 0...110 °C 0...90 °C 0...90 °C
CIP/SIP cleaning 143 °C/120 min. 143 °C/120 min.
Process pressure Max. 10 bar Max. 10 bar Max. 10 bar Max. 10 bar
“SEIL”(rope) option:
Max. 1 bar
Tightening torque - 10...20 Nm - -
Materials
Connecting head Stainless steel (1.4305) Stainless steel (1.4305) PP hard plastic PP hard plastic
(Threaded) connector Stainless steel (1.4305) Stainless steel (1.4305) PP hard plastic PP hard plastic
Electrodes Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404)
Ropes/ Stainless steel (1.4401)/
rope weights - - Stainless steel (1.4404) -
Insulator PEEK PEEK - -
Coating
(electrodes) PFA PFA PFA PFA
Coating (rope) - - Polyamide PA6 -
Rope electrodes
available No No Yes (NVS-110.SEIL) No
Electrical connection M12 plug connection (1.4305)
Cable gland M16 x 1.5
Protection class IP 69 K (with M12 plug connection)
IP 67 (with cable gland)
*) When using the integrated level transmitter MNV-1C, please note the temperatures specified below in the technical data
of the level transmitter.
Full indicator: The output is active when immersed 3 function 4 sensitivity 0.1 kΩ sensitivity 1 kΩ
Empty indicator: The output is active when not immersed “full”
1 2 3 4 5 1: Ground (sensor) 4 1 3 2 5
2: Electrode (sensor)
3: Active output
4: Supply voltage
5: 15...36 V DC
· If necessary, cut the electrodes to the required lengths. In doing so, ensure that the compound between the rod and the
thread connector is not strained excessively. If using coated electrodes, do not damage the insulation of the rod part
that remains on the sensor.
· Strip 5 mm of insulation off the tip of insulated rods.
· Screw the sensor into the sleeve and connect as shown in the wiring diagram. Do not damage the coating when insert-
ing the sensor into the sleeve.
FOOD Dimensional drawings 4
1 2 3 4 M
1 4 2
(5/3)
1 5 2
This sensor does not This sensor does not This sensor does not This sensor does not
conform to hygienic conform to hygienic conform to hygienic conform to hygienic
requirements. requirements. requirements. requirements.
5 Notes FOOD
· The plastics used in the NVS-345 and NVS-50 sensors are materials approved by European Regulations 1935/2004
and 10/2011 for contact with food.
· The materials of the NVS-110, NVS-110.SEIL and NVS-120 sensors are not in accordance with the European regulations
specified above.
Mounting instructions
· When installing the NVS-345, only use Negele weld-in systems to ensure proper functioning of the measuring point.
· When screwing in the sensors, do not exceed the maximum permissible torque (see the technical data on page 2).
· If the tank wall is being used as the reference electrode (only possible with NVS-345 and NVS-50), ensure that the sen-
sor process connection makes good electrical contact with the pipe and tank wall. Do not use insulating sealants such
as Teflon. The tank wall must be made of metal in this case.
· When installing the sensors, ensure that the electrode emerges from the medium when it is drained.
· When tightening and loosening the sensor, only use the wrench flats provided this purpose, never the connecting
head.
Cleaning/Maintenance Transport/Storage
· When using a pressure washer, do not point the nozzle · No outdoor storage
directly at the electrical connections. · Store in an area that is dry and dust-free
· Do not expose to corrosive media
· Protect against solar radiation
· Avoid mechanical shock and vibration
Reshipment · Storage temperature 0...40 °C
· Relative humidity max. 80%
· Sensors and process connection must be clean and must
not be contaminated with hazardous media and/or heat-
conductive paste. Note the cleaning information!
· To avoid damage of the equipment, use suitable trans- Standards and guidelines
port packaging only.
· Compliance with the applicable regulations and direc-
tives is mandatory.
Notice on conformity
NVS-110.SEIL (Head diameter 55 mm of plastic with G1" process connection and rope electrodes)
Electrode 1
[m] (lengths in m)
Electrode 2
(selection options: see Electrode 1)
Electrode 3
(selection options: see Electrode 1, evaluation unit not possible)
Electrode 4
(selection options: see Electrode 1, evaluation unit not possible)
Electrode 5
(selection options: see Electrode 1, evaluation unit not
possible)
NVS
-345 (Head diameter 55 mm of stainless steel with CLEANadapt G1" hygienic process connection)
-110 (Head diameter 55 mm of plastic with G1" process connection)
-120 (Head diameter 55 mm of plastic with G1½" process connection)
-50 (Head diameter 55 mm of stainless steel with dairy flange DN50 as per DIN 11851)
Electrode 1
200N (uncoated 200 mm, diameter 4 mm)
200N-8 (uncoated 200 mm, diameter 8 mm)
200B (coated 200 mm, diameter 4 mm)
200B-8 (coated 200 mm, diameter 8 mm)
500N (uncoated 500 mm, diameter 4 mm)
500N-8 (uncoated 500 mm, diameter 8 mm)
500B (coated 500 mm, diameter 4 mm)
500B-8 (coated 500 mm, diameter 8 mm)
850N (uncoated 850 mm, diameter 4 mm)
850N-8 (uncoated 850 mm, diameter 8 mm)
850B (coated 850 mm, diameter 4 mm)
850B-8 (coated 850 mm, diameter 8 mm)
1000N (uncoated 1000 mm, diameter 4 mm)
1000N-8 (uncoated 1000 mm, diameter 8 mm)
1000B (coated 1000 mm, diameter 4 mm)
1000B-8 (coated 1000 mm, diameter 8 mm)
1500N (uncoated 1500 mm, diameter 4 mm)
1500B (coated 1500 mm, diameter 4 mm)
2000N (uncoated 2000 mm, diameter 4 mm)
2000B (coated 2000 mm, diameter 4 mm)
2500N (uncoated 2500 mm, diameter 4 mm)
[mm]N Special length, uncoated
[mm]B Special length, coated
[m] (length in m; only for NVS-110.SEIL)
Electrode 2
(selection options: see Electrode 1)
Electrode 3
(selection options: see Electrode 1, evaluation unit not possible)
Electrode 4
(selection options: see Electrode 1, evaluation unit not possible)
Electrode 5
(not for NVS-345, selection options: see Electrode 1, evaluation
unit not possible)
Accessories
Instead of the integrated level transmitter, standard multilevel sensors can also be used with external devices for
installation on DIN rails, for example. The full selection of external evaluation units, the technical data and the order
code can be found in the „Evaluation units for conductive multilevel sensors“ product information.
Overview of the evaluation units for conductive multilevel sensors for DIN-rail installation
Advice
For level measurement according to German Water Management Act, please use the separate product information
NVS-146.w, NVS-116.2w, NVS-345.2w.
Notes