OPERATING RANGE
NOMINAL FLOW MAXIMUM PRESSURE TEMPERATURE RANGE VISCOSITY RANGE
SERIES GPM m3 h PSI Bar °F °C SSU cSt
124A Series™
8 - 500 1.8 - 114 200 14 −60 to +450 −50 to +230 28 to 2,000,000 0.1 to 440,000
124AE Series™ **
1124A Series™
8 - 400 1.8 - 91 200 14 0 to +225* −15 to +105* 100 to 2,500* 20 to 550*
1124AE Series™ **
4124A Series™
8 - 500 1.8 - 114 200 14 −60 to +450 −50 to +230 28 to 2,000,000 0.1 to 440,000
4124AE Series™ **
4124B Series™ 8 - 500 1.8 - 114 200 14 −60 to +450 −50 to +230 28 to 15,000 0.1 to 3,300
324A Series™ 600 - 1,600 136 - 364 200 14 −60 to +450 −50 to +230 28 to 2,000,000 0.1 to 440,000
1324A Series™ 500 - 1,300 136 - 295 200 14 0 to +225* −15 to +105* 100 to 750* 20 to 165*
4324A Series™ 600 - 1,600 136 - 364 200 14 −60 to +450 −50 to +230 28 to 2,000,000 0.1 to 440,000
* Range may increase with end clearance adjustment. ** AE available in sizes L, LQ, LL only.
NOTE: See page 1401.9 for a complete list of casing options by size.
L Q 4 1 2 4 A E
Size: Basic Series Material of Primary Shaft Diameter
G LL Configuration Construction: (L, LQ and LL Sizes in Cast Iron Only):
H LS 4 = Cast Iron
Jacketing: Blank = 1-7/16"
HL Q E = 1-5/8"
1 = No Jacketing
AK QS (See dimension drawings for shaft diameter at coupling)
3* = Foot Mount Casing w/ Jacketed Bracket
AL M
K N Shaft Seal: Seal Location:
LQ Blank = Packing
* Note: Only the N, R & RS sizes are foot mount casing with jacketed bracket.
① G, H and HL sizes have a powdered metal idler: Powdered Metal MPIF 35, FC-0208-45 (G) , Powdered Metal MPIF 35, FC-0208-50 (H, HL)
② Q and QS sizes have a hardened steel idler when pump is steel fitted: ASTM A148 Grade 80-40.
③ AK, KK, LS, QS, N and RS sizes have ductile iron rotor: ASTM A536 Grade 60-40-18.
④ Material specification for HL steel rotor is AISI 8620, LS steel rotor is ASTM A148 80-50.
⑤ AK, AL, K, KK, L, LQ, LL and LS sizes, including “A”, “AE”, and “B” models, are high strength steel ASTM A434 Type 4140 Grade BC or equivalent.
⑥ RS relief valve not available. Contact factory for options.
One-piece cast
bracket with seal
between bearings
provides rigid
foundation to
maximize seal
and bearing life
Rotor end clearance can be adjusted Internal relief valve standard*;
to compensate for wear or for higher less valve / plain head and return-
temperatures or viscosities by rotating to-tank relief valves optional
the threaded bearing housing
Internal pressure
relief valve standard,
protects pump from
overpressure; less
valve / plain head and
return-to-tank relief
Threaded bearing housing valves optional
enables fast, easy end clearance
adjustment for viscosity or wear
Behind the rotor seal
Rigid cast iron mounting bracket protects bracket bushing
helps ensure alignment and minimizes effects of from wear or corrosion
pipe strain for the longest seal and bearing life
Pump Size
Viscosity
G H HL AK AL K KK L LQ LL LS Q QS M N R RS
SSU 7,500 25,000 7,500 25,000 25,000 25,000 75,000 25,000 25,000 2,500 75,000 7,500 75,000 25,000 75,000 25,000 75,000
cSt 1,700 5,500 1,700 5,500 5,500 5,500 17,000 5,500 5,500 550 17,000 1,700 17,000 5,500 17,000 5,500 17,000
For low viscosities or non-lubricating liquids – Below 100 SSU (20 cSt)
• Carbon graphite bushings.
• Pump should be operated at slower than normal speeds, which may require a larger pump.
③ ② Maximum
Standard ④ Maximum ① Recommended
NPT Nominal Pump Rating Hydrostatic Maximum Discharge Temperature for Approx. Shipping
Port Size (100 SSU & below) Pressure Pressure Standard Pump Weight with Valve
Model
Number Inches GPM m3/h RPM PSIG BAR PSIG BAR °F °C Lbs. Kg.
G124A 1 8 1.8 1750 400 28 200 14 450 230 25 11
G4124A 1 8 1.8 1750 400 28 200 14 350 175 25 11
G4124B 1 8 1.8 1750 400 28 200 14 350 175 22 10
H124A 1½ 15 3.5 1750 400 28 200 14 450 230 38 17
H1124A 1½ 8 1.8 1000 400 28 200 14 225 105 40 18
H4124A 1½ 15 3.5 1750 400 28 200 14 350 175 38 17
H4124B 1½ 15 3.5 1750 400 28 200 14 350 175 38 17
HL124A 1½ 30 7 1750 400 28 200 14 450 230 40 18
HL1124A 1½ 18 4 1000 400 28 200 14 225 105 40 18
HL4124A 1½ 30 7 1750 400 28 200 14 350 175 40 18
HL4124B 1½ 30 7 1750 400 28 200 14 350 175 40 18
AK124A 2 65 15 1450 400 28 200 14 450 230 82 37
AK4124A 2 65 15 1450 400 28 200 14 350 175 82 37
AK4124B 2 65 15 1450 400 28 200 14 350 175 78 35
AL124A 2 90 20 1450 400 28 200 14 450 230 85 39
AL4124A 2 90 20 1450 400 28 200 14 350 175 85 39
K124A 2 80 18 780 400 28 200 14 450 230 105 48
K1124A 2 80 18 780 400 28 200 14 225 105 110 50
K4124A 2 80 18 780 400 28 200 14 350 175 105 48
K4124B 2 80 18 780 400 28 200 14 350 175 105 48
KK124A 2 100 23 780 400 28 200 14 450 230 110 50
KK1124A 2 100 23 780 400 28 200 14 225 105 110 50
KK4124A 2 100 23 780 400 28 200 14 350 175 110 50
KK4124B 2 100 23 780 400 28 200 14 350 175 110 50
L124A 2 135 31 640 400 28 200 14 450 230 155 70
L124AE 2 135 31 640 400 28 200 14 450 230 155 70
L1124AE 2 135 31 640 400 28 200 14 225 105 147 67
L4124A 2 135 31 640 400 28 200 14 350 175 155 70
L4124AE 2 135 31 640 400 28 200 14 350 175 155 70
L4124B 2 135 31 640 400 28 200 14 350 175 155 70
① For maximum recommended discharge pressures at different ③ Ports are tapped for standard (NPT) pipe. Other thread standards
viscosities, see performance curves, which can be electronically available. G through L ports are at 90°.
generated with the Viking Pump Curve Generator, located on ④ Maximum hydrostatic pressure for standard pump construction.
www.vikingpump.com. If suction pressure exceeds 50 PSIG, Rating is dependent on seal, gaskets and ports.
consult factory. Higher pressures possible with factory approval
based on application details.
② Extra clearances are required above 225°F / 105°C.
Higher temperatures can be handled with special construction,
consult factory.
① Maximum ② Maximum
③ ④ Maximum Discharge Pressure Recommended
Standard Nominal Pump Rating Hydrostatic for 100 SSU liquid Temperature for Approx. Shipping
Port Size (100 SSU & below) Pressure at rated speed Standard Pump Weight with Valve
Model
Number Inches GPM m3/h RPM PSIG BAR PSIG BAR °F °C Lbs. Kg.
LQ124A 2½ 135 31 640 300 21 200 14 450 232 175 80
LQ124AE 2½ 135 31 640 300 21 200 14 450 232 175 80
LQ1124AE 2½ 120 27 520 400 28 200 14 225 110 191 87
LQ4124A 2½ 135 31 640 300 21 200 14 350 175 175 80
LQ4124AE 2½ 135 31 640 300 21 200 14 350 175 175 80
LQ4124B 2½ 135 31 640 300 21 200 14 350 175 175 80
LL124A 3 140 32 520 300 21 200 14 450 232 185 84
LL124AE 3 140 32 520 300 21 200 14 450 232 185 84
LL1124AE 3 140 32 640 400 28 200 14 225 110 199 90
LL4124A 3 140 32 520 300 21 200 14 350 175 185 84
LL4124AE 3 140 32 520 300 21 200 14 350 175 185 84
LL4124B 3 140 32 520 300 21 200 14 350 175 185 84
LS124A 3 200 45 640 300 21 200 14 450 232 190 86
LS1124A 3 200 45 640 400 28 200 14 225 110 228 103
LS4124A 3 200 45 640 300 21 200 14 350 175 190 86
LS4124B 3 200 45 640 300 21 200 14 350 175 190 86
Q124A 4 300 68 520 250 17 200 14 450 232 440 200
Q1124A 4 275 62 470 250 17 200 14 225 110 472 214
Q4124A 4 300 68 520 250 17 200 14 350 175 440 200
Q4124B 4 300 68 520 250 17 200 14 350 175 440 200
QS124A 6 500 114 520 250 17 200 14 450 232 540 245
QS1124A 6 400 91 470 250 17 200 14 225 110 507 230
QS4124A 6 500 114 520 250 17 200 14 350 175 540 245
QS4124B 6 500 114 520 250 17 200 14 350 175 540 245
M124A 4 420 95 420 250 17 200 14 450 232 600 272
M4124A 4 420 95 420 250 17 200 14 350 175 600 272
N324A 6 600 136 350 250 17 200 14 450 232 810 367
N1324A 6 535 122 330 250 17 200 14 225 110 937 425
N4324A 6 600 136 350 250 17 200 14 350 175 810 367
R324A 8 1100 250 280 250 17 200 14 450 232 1435 651
R1324A 8 915 208 225 250 17 200 14 225 110 1523 961
R4324A 8 1100 250 280 250 17 200 14 350 175 1435 651
RS324A 10 1600 364 280 250 17 125 8.5 450 232 2000 907
RS1324A 10 1300 295 255 250 17 125 8.5 225 110 1973 895
RS4324A 10 1600 364 280 250 17 125 8.5 350 175 2000 907
① For maximum recommended discharge pressures at different ③ Flange ports are suitable for use with Class 125 ANSI cast iron
viscosities, see performance curves, which can be electronically companion flanges or flanged fittings.
generated with the Viking Pump Curve Generator, located on LQ, LL, LS, Q & M ports are at 90°
www.vikingpump.com. If suction pressure exceeds 50 PSIG, QS, N, R and RS ports are at 180° (opposite)
consult factory. Higher pressures possible with factory approval ④ Maximum hydrostatic pressure for standard pump construction.
based on application details. Rating is dependent on seal, gaskets and ports.
② Extra clearances are required above 225°F / 105°C.
Higher temperatures can be handled with special construction,
consult factory.
OPTIONAL CASINGS
Standard Casings
Ports
Size (Inches) Rotatable Data Optional Casings
G 1.5”①Ⓡ Fully Rotatable 1.5”②Ⓡ 1.5”③Ⓡ 2”②Ⓡ
H 1.5”①Ⓡ Fully Rotatable 1.5”②Ⓡ 1.5”③Ⓡ 2”②Ⓡ
HL 1.5”①Ⓡ Fully Rotatable 1.5”②Ⓡ 1.5”③Ⓡ 2”②Ⓡ
AK 2”①Ⓡ Fully Rotatable
AL 2”①Ⓡ Fully Rotatable
K 2”①Ⓡ Fully Rotatable 2”②Ⓡ 2”③Ⓡ 2.5”①Ⓞ 2.5”②Ⓡ 3”②Ⓡ 4”②Ⓡ
KK 2”①Ⓡ Fully Rotatable 2”②Ⓡ 2”③Ⓡ 2.5”①Ⓞ 2.5”②Ⓡ 3”②Ⓡ 4”②Ⓡ
L 2”①Ⓡ Fully Rotatable
Side 5”②Ⓡ,
LQ 2.5”②Ⓡ Ports cannot face down 2.5”③Ⓡ 3”②Ⓡ 4”②Ⓡ 6”②Ⓡ*
Top 6”②
LL 3”②Ⓡ Fully Rotatable 3”③Ⓡ 4” ②Ⓡ 5”②Ⓡ*
LS 3”②Ⓡ Fully Rotatable 3”③Ⓡ 4” ②Ⓡ*
Side 4” ②Ⓡ, Side 4” ②Ⓛ, Side 6” ②Ⓡ,
Q 4”②Ⓡ Fully Rotatable 4”③Ⓡ 3”②Ⓡ 5”②Ⓡ 6”②Ⓞ
Top 8” ② Top 8” ② Top 8” ②
QS 6”②Ⓞ Rotatable with special casing 6”②Ⓡ
M 4”②Ⓡ Fully Rotatable 6”②Ⓡ 6”②Ⓞ
N 6”②Ⓞ Not Rotatable 5”②Ⓝ 6”②Ⓝ
R 8”②Ⓞ Not Rotatable 6”②Ⓝ
RS 10”②Ⓞ Not Rotatable 10”②
① Port(s) tapped for standard (NPT) pipe. Ⓛ 90° port arranged for Left Hand inlet (viewed from shaft end)
② Port(s) suitable for use with Class 125 ANSI cast iron companion Ⓝ Non-Rotatable Ports at 90° angle, contact factory for available
flanges or flanged fittings. orientation (right hand or left hand)
③ Port(s) suitable for use with Class 250 ANSI cast iron companion Ⓞ Opposite Ports
flanges or flanged fittings. Ⓡ 90° port arranged for Right Hand inlet (viewed from shaft end)
* Core smaller than port size
U
C
V D
P J O
F E E
M H L G
These dimensions are average and not for construction purposes. Certified prints on request. NOTE: Dimensions “N” through “W” on next page
Model Number
Mechanical A
Packed O-Pro™ Seal Seal (in) B C D E F G H J K L M
G4124A in 2.50 3.66 2.75 1.62 1.31 4.00 2.38 0.34 0.57 1.21 4.87
G124A ①1
G4124B mm 64 93 70 41 33 102 60 9 14 31 124
H4124A
in 3.00 4.75 3.50 2.75 2.25 6.75 3.50 0.47 0.99 3.38 5.19
H124A H1124A H4124B
① 1.5
HL124A HL1124A HL4124A
mm 76 121 89 70 57 171 89 12 25 86 132
HL4124B
AK4124A in 4.50 6.75 5.25 2.88 2.00 6.75 4.03 0.41 1.67 2.82 8.84
AK124A
AL4124A ①2
AL124A
AK4124B mm 114 171 133 73 51 171 102 10 42 72 225
K4124A
in 5.12 8.00 5.50 4.00 2.75 9.25 4.00 0.53 1.42 3.00 9.38
K124A K1124A K4124B
①2
KK124A KK1124A KK4124A
mm 130 203 140 102 70 235 102 13 36 76 238
KK4124B
L124A L4124A/AE in 6.50 10.25 7.00 4.38 4.00 10.00 5.38 0.53 1.42 ④ 3.38 9.12
L1124AE ①2
L124AE L4124B mm 165 260 178 111 102 254 137 13 36 ④ 86 232
LQ124A LQ4124A/AE in 7.19 10.25 7.00 4.38 4.00 10.00 5.38 0.53 1.42 ④ 3.38 9.12
LQ1124AE ② 2.5
LQ124AE LQ4124B mm 183 260 178 111 102 254 137 13 36 ④ 86 232
LL124A LL4124A/AE in 7.19 10.25 7.00 4.38 4.00 10.00 5.38 0.53 1.42 ④ 3.38 9.12
LL1124AE ②3
LL124AE LL4124B mm 183 260 178 111 102 254 137 13 36 ④ 86 232
LS4124A in 7.19 10.25 7.00 4.38 4.00 10.00 5.38 0.53 2.55 4.75 9.12
LS124A LS1124A ②3
LS4124B mm 183 260 178 111 102 254 137 13 65 121 232
Q4124A in 8.25 14.00 8.75 4.12 4.00 10.00 6.00 0.69 3.58 6.62 11.12
Q124A Q1124A ②4
Q4124B mm 210 356 222 105 102 254 152 18 91 168 282
in 9.50 17.35 10.00 5.00 6.00 12.00 8.53 0.69 3.50 7.75 8.10
M124A M4124A ②4
mm 241 441 254 127 152 305 217 18 89 197 206
① Ports are tapped for standard (NPT) pipe. Other thread standards available.
② Ports are suitable for use with Class 125 ANSI cast iron.
③ Ports are suitable for Class 150 ANSI steel or stainless steel companion flanges or flanged fittings.
④ “K” dimension for L, LQ & LL sizes is for “A” and “B” models. “K” dimension for L, LQ & LL size “AE” models is 1.30” (33.0 mm).
DIMENSIONS – G, H, HL, AK, AL, K, KK, L, LQ, LL, LS, Q, M SIZES (CONT'D)
S W
B A
T R N
K
U
C
V D
P J O
F E E
M H L G
These dimensions are average and not for construction purposes. Certified prints on request. NOTE: Dimensions “A” through “M” on previous page
Model Number
Mechanical U V
Packed O-Pro™ Seal Seal N O P R S T (in) (in) W
G4124A in 1.09 0.31 0.63 7.40 9.55 1.06 2.71
G124A 0.50 .12 x .06
G4124B mm 28 8 16 188 143 27 69
H4124A
in 1.19 0.56 0.62 10.44 13.25 1.62 2.85
H124A H1124A H4124B
0.75 .19 x .09
HL124A HL1124A HL4124A
mm 30 14 16 265 337 41 72
HL4124B
AK4124A in 2.00 0.44 1.00 13.19 17.69 2.50 4.83
AK124A
AL4124A 1.00 .25 x .12
AL124A mm 51 11 25 335 449 64 123
AK4124B
K4124A
in 1.75 0.62 0.62 14.12 18.12 2.25 5.25
K124A K1124A K4124B
1.12 .25 x .12
KK124A KK1124A KK4124A
mm 44 16 16 359 460 57 133
KK4124B
in 1.75 0.62 0.62 15.62 19.62 2.25 5.43
L124A L4124A 1.12 .25 x .12
mm 44 16 16 397 498 57 138
L4124AE in 1.75 0.62 0.62 15.62 19.62 2.35 5.43
L124AE L1124AE 1.44 .38 x .19
L4124B mm 44 16 16 397 498 60 138
in 1.75 0.62 0.62 15.62 19.62 2.25 5.43
LQ124A LQ4124A 1.12 .25 x .12
mm 44 16 16 397 498 57 138
LQ4124AE in 1.75 0.62 0.62 15.62 19.62 2.35 5.43
LQ124AE LQ1124AE 1.44 .38 x .19
LQ4124B mm 44 16 16 397 498 60 138
in 2.25 0.62 0.62 15.62 20.12 2.25 5.43
LL124A LL4124A 1.12 .25 x .12
mm 57 16 16 397 511 57 138
LL4124AE in 2.25 0.62 0.62 15.62 20.12 2.35 5.43
LL124AE LL1124AE 1.44 .38 x .19
LL4124B mm 57 16 16 397 511 60 138
LS4124A in 2.44 0.62 0.62 15.75 21.69 3.50 5.43
LS124A LS1124A 1.44 .38 x .19
LS4124B mm 62 16 16 400 551 89 138
Q4124A in 3.00 0.8 1.00 19.25 26.75 4.50 8.25
Q124A Q1124A 1.94 .50 x .25
Q4124B mm 76 20 25 489 679 114 210
in 4.00 1.00 1.52 20.13 28.38 4.25 8.61
M124A M4124A 1.94 .50 x .25
mm 102 25 39 511 721 108 219
DIMENSIONS – QS SIZE
Dimensions shown in inches with millimeter equivalent shown in parentheses
28.25
718
19.75
502
4.50 4.00 8.29 9.00 9.00
114 102 211 229 229
4.37
111
2X 3.00
76
1.94 8.75
FLANGE*
222
.50 X .25
KEYWAY
* 124A Series™, 1124A Series™, 4124A Series™ ports suitable for use with Class 125 ANSI cast iron companion flanges or flanged fittings.
NOTE: Flanges are 6", suitable for use with Class 125 ANSI cast iron companion flanges or flanged fittings. They are studded, not through-bolt.
NPT X 4
Model Number
Stuffing A
Packed O-Pro™ Seal Box Seal (in) B C D E F G H J K M N
① in 9.75 17.25 9.50 5.00 6.25 8.69 1.62 0.69 4.50 12.00 4.50
N324A N1324A N4324A
6 mm 248 438 241 127 159 221 41 18 114 305 114
① in 14.25 24.50 13.25 6.75 7.00 10.56 2.31 0.78 6.00 16.00 5.62
R324A R1324A R4324A
8 mm 362 622 337 171 178 268 59 20 152 406 143
① in 14.25 24.5 13.25 6.75 7.00 13.12 4.81 0.88 6.00 16.46 8.12
RS324A RS1324A RS4324A
10 mm 362 622 337 171 178 333 122 22 152 418 206
Model Number
Stuffing
Packed O-Pro™ Seal Box Seal O P R S T U (in) V (in) W X Y Z
in 1.00 3.00 26.00 36.50 6.00 8.63 0.69 — 18.94
N324A N1324A N4324A 2.44 .62 x.31
mm 25 76 660 927 152 219 18 — 481
in 1.00 4.50 28.75 41.00 6.62 12.00 0.69 1.25 19.25
R324A R1324A R4324A 3.44 .88 x.44
mm 25 114 730 1041 168 305 18 32 489
in 1.30 4.50 28.55 43.49 6.62 — 0.88 1.25 19.25
RS324A RS1324A RS4324A 3.44 .88 x.44
mm 33 114 725 1105 168 — 22 32 489
① Ports are suitable for use with Class 125 ANSI cast iron (324A Series™/4324A Series™)
NOTE: The N size is standard with a jacketed bracket and non-jacketed head and non-jacketed relief valve, while the “R” size
is standard with a jacketed bracket, a jacketed head, and a non-jacketed relief valve. “RS” contact factory for jacketing options.
RS relief valve not available. Contact factory for options.
Pump Size A B C D E F G H J K L M N O P R
In 1.63 2.12 1.91 1.38 0.57 1.72 3.87 2.74 to 3.12 1.64 2.24 3.62 1.00 3.87 1/8
G 0.75 5/16
mm 41 54 49 38 15 44 98 70 to 79 42 57 92 25 98 3
In 2.00 2.41 2.22 1.90 1.03 2.27 4.50 3.00 to 3.50 2.00 2.50 4.00 0.66 4.47 1/8
H & HL 1.12 5/16
mm 51 61 56 48 26 58 114 76 to 89 51 64 102 17 114 3
In 2.31 2.69 2.75 2.25 1.24 3.03 5.25 3.14 to 4.56 2.50 3.00 5.00 0.47 6.15 1/4
AK & AL 1.44 7/16
mm 59 68 70 57 32 77 133 80 to 116 64 76 127 12 156 6
In ①2.31 3.00 3.13 2.25 1.25 3.00 5.25 3.50 to 4.50 2.50 3.00 5.00 0.38 5.25 1/4
K & KK 1.44 7/16
mm ①58.7 76 80 57 32 76 133 89 to 114 64 76 127 10 133 6
In ①2.31 3.00 3.13 2.25 1.25 4.00 5.25 3.50 to 4.50 2.50 3.00 5.00 0.44 5.25 1/4
L, LQ, & LL (A) 1.44 7/16
mm ①58.7 76 80 57 32 102 133 89 to 114 64 76 127 11 133 6
In 2.38 3.00 3.13 2.25 1.16 3.52 5.25 3.50 to 4.50 3.00 3.00 5.00 0.46 5.25 1/4
L, LQ, & LL (AE) 1.62 7/16
mm 60 76 80 57 30 89 133 89 to 114 76 76 127 12 133 6
In 2.38 2.80 2.70 2.25 1.16 3.52 5.25 3.25 to 4.50 3.00 2.80 5.00 0.46 5.25 1/4
LS 1.62 7/16
mm 60 71 69 57 30 89 133 83 to 114 76 71 127 12 133 6
In 3.42 4.50 4.00 2.50 1.53 4.10 6.75 5.50 to 6.25 3.20 4.50 7.20 0.56 6.75 1/4
Q & QS ③ 2.44 5/8
mm 87 114 102 64 39 104 171 140 to 159 81 114 183 14 171 6
In 3.44 — 3.97 2.50 1.53 4.16 6.75 5.44 to 6.26 3.28 4.50 7.20 0.72 7.37 1/4
M 2.44 5/8
mm 87 — 101 64 39 106 171 138 to 159 83 114 183 18 187 6
In 4.69 — 5.56 1.65 — 4.91 8.81 6.75 — — — — 9.00 1/4
N 3.44 ②3/4
mm 119 — 141 42 — 125 224 171 — — — — 229 6
In 5.75 — 5.56 1.53 — 4.79 9.81 7.75 — — — — 9.81 1/4
R & RS 4.50 ②3/4
mm 146 — 141 39 — 122 249 197 — — — — 249 6
① Bracket is counter bored to a diameter of 2.687 inches (68 mm), 0.12 inches (3 mm) deep from stuffing box face.
② Studs are used in place of cap screws.
③ For Q, QS size brackets, seal box dimensions differ between O-Pro™ Barrier and traditional seal options. Consult factory for options.
NPSH REQUIRED
Printed performance curves are not available.
Performance curves can be electronically generated with the Viking Pump Curve Generator on vikingpump.com.
NPSHR data is not available on the pump selector.
NPSH (Net Positive Suction Head): The NPSHR (Net Positive Suction Head Required by the pump) is given in the table below
and applies for viscosities through 750 SSU. NPSHA (Net Positive Suction Head – Available in the system) must be greater than
the NPSHR. For a complete explanation of NPSH, see Application Data Sheet AD-19.
FOR VISCOSITIES UP TO 750 SSU – See NPSHR table below.
NPSHR for high viscosities can be estimated using the following method:
1. Calculate line loss for a 1 foot long pipe of a diameter matching the pump inlet port size. Use your flow rate and max viscosity.
2. Convert this value into Feet of Liquid (S.G. 1.0)
3. Add this value to the NPSHR value in the chart below.