0% found this document useful (0 votes)
55 views3 pages

Pacific Mercury - VDR Performance Test Report

afs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
55 views3 pages

Pacific Mercury - VDR Performance Test Report

afs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
Gopan Radio Co. Ltd. VOYAGE DATA RECORDER PERFORMANCE TEST REPORT (Note: Insert Yes for success, No for failure or NIA for non-fited interfaces in these boxes, as appropriate) ‘sdetaiis Ships name RSTERST Fiag HONG KONG [IMO number (9714630 Date ceo laid BE Aor, 12075 ‘Gross tonnage 78.205 Voyage data recorder details [Manutacurer —_____.- span Rao Cote) Mode! JCY-1900 Systeriseral umber iaastsae ‘Sofware version number D108 Date tee TE Ten. 12015 Inspection detalis Name of person conducting testing J LUIS ALVAREZ ‘Company 1 HI TEK MARINE S.A. inspection date ZT Feb. 12023 inspection iocaton TALBOA, PANAVA 4 Preexisting alarms Yes} [No] [Confirm that no alarms were present at start of procedure Iwo ] 2 Power supply alarm checic [ Remave source of edemal power Confim that ams acivated —] [Record time (hh:mm) I 14:25 (UTC) ol 1. ] 3 Reserve power source check Allow VOR to continue running for 1 hour $$ minutos trom 2" above, Confirm tet equipments sil operating at his time, with no addtional alarms Recor ime Gam] _—] ED —UAG) Ima 4 Reserve power source shutdown check ZRoUws OS minules fom P above confirm that he VOR hes autoratoally Stopped recorsing Record fime fmm) —] Ee momo 5 Expiry dates nie Expy Sate [where appleabie] Using manufacturers fest equipment confirm that acoustic beacon Is functional cor by the substitution of a certified fuly operational unt. [Rcoustie beacon t ‘Sep. /2024 Eo FFC's Battery i Oct. 12027 ECs HRU Oct 12026 [Reserve power source | Des. [2026 8 Acoustic beacon test URC lev4, (062022) MSC.1-Cire-1222-Rev.1 7 Overall condition of equipment Inspect equipment end record condition, tick if satisfactory. ‘Sub unit Notes on condition [Yes] (Ne) Twa} Protective capsule, [Good Float free capsule [Good i 1 ([Extemal cables [Good [Main unit’ [Sood [sete inivenant [Conirm that orginal JRG Reserve Pow Source tihetaled I< s}sisis} 8 Interfaces: Operation and recording Date and time Preferably external to ship (e.g. Giobal | Navigation Satellite ae L System) Sas postion Electonie PeatOAMS Joga | system | Speed [rough waterar | Snips desgratea | over ground), speed andistence — |vaw.vTe reaauring equipment Tesang ‘Ships compass = Brage audio Tor mare badge | microphones jAlo! Communications Audio| VEF = Radar date- post displey selection Master radar deplay (both racars, where Iho & No & No-SRADAR [as I lvoo,vom L spplicable) | EODIS ECDIS dispiayinuse, |, . where fited (niacin AIAIS data [Rong moter Electronic inclinometer, where fitted Configuration data ‘Where applicable [sya er VOR rain nt Electronic logbook ‘Where fited Water depih Echo sounder pet [ainsi as on RB BET] Fp eC | bridge [Booycame sores Rudder orderand | Steering gearend | leparee | autopil |HTD,RSA, Analog, RMS Engine order and Telegraphs, controls | Cw Ome Dewar response end thrusters Drees Hull openings status | Al mancetory satus information displayed | on bridge Weterightand fre Gor | All mandatory satus stetus information displayed ory Contact fon brege ‘Aeceleralon and hall | Hull sess and | stresses response monitoring | equipment where fed Wind speed and ‘Anemometer wnere | girection fitted ~~ z wm mw wm wm wm mo wm wm wo o wm o JOO 000000 0 Uk UU UOOUU00UUUO0O00000 0 Co Co at fe ww Ea wo Ey HOO IRC Rev4 (Oct 2022) MSC.1-Cire.1222-Rev.t ° Flost-free capsule For fioatiree capsules aparoved in accordance with resolution MSC.383(80): SF ....ca4 on anal eet guile ‘examination according to MSC.1/Cire. 1040/ Rev.2 has been conducted 10 Change or repair of sensors vj CJ (Check maintenance records of VOR (Confirm any defects properly recified LUIS ALVAREZ| 27 / Feb, 2028 Lug 4, Alvarez “Re Engineer comments; |SOFTWARE UPDATE DURING THE SERVICE IRCU APP:01,08.004 JRO Revd (0012022) MSC.1-Cte 1222Rew

You might also like