RIVIT RIV504 Manual Eng It Comp WM
RIVIT RIV504 Manual Eng It Comp WM
RIVIT RIV504 Manual Eng It Comp WM
IT MANUALE ISTRUZIONI
RIVETTATRICE OLEOPNEUMATICA CON
TRATTENUTA DEL RIVETTO E RECUPERO
DEL CHIODO TRANCIATO CON ARIA
APERTA PER RIVETTI IN TUTTE LE LEGHE
DAL Ø 4,0 AL Ø 6,4 E STRUTTURALI FINO
AL Ø 6,4
EN
IT INSTRUCTION MANUAL
HYDRO-PNEUMATIC TOOL WITH
HOLDING OF THE RIVET AND NAIL
RECOVERY WITH OPEN AIR FOR BLIND
RIVETS IN ALL MATERIALS FROM Ø 4,0
TO 6,4 AND STRUCTURAL UP TO Ø 6,4
FR
IT MANUEL D'INSTRUCTIONS
RIVETEUSE OLEOPNEUMATIQUE POUR
RIVETS ALU/ACIER/INOX DE Ø 4,0 A Ø 6,4
ET RIVETS DE STRUCTURE JUSQU'A'
Ø 6,4
ITA ENG
INDEX
WARRANTY ...........................................................................................................................................16
TECHNICAL DATA .................................................................................................................................17
ACCESSORIES SUPPLIED ...................................................................................................................18
ACCESSORIES ON REQUEST..............................................................................................................19
SAFETY MEASURES.............................................................................................................................20
OPERATING INSTRUCTIONS ...............................................................................................................20
SIZE CHANGING AND MAINTENANCE ................................................................................................21
OIL TOPPING UP ..................................................................................................................................22
ELIMINATION OF THE TOOL ................................................................................................................22
LIST OF SPARE PARTS .........................................................................................................................23
REV | 02 15 | 40
EN RIV 504
WARRANTY
The warranty has a validity of 12 months, as of the date indicated on the invoice.
The warranty only covers replaced parts; labour is not included.
The following are not covered by warranty: standard accessories and tool damages caused by:
• transport and/or handling
• user’s mistakes
• failed servicing/maintenance, as indicated in this manual
• faults and/or breakages that are not attributable to tool anomalies
• normal consumption of consumables.
The warranty is invalidated both in case of unauthorised tampering/replacements of tool components
and in case of use of accessories, tools or consumables different to those recommended by the manu-
facturer, which could even cause injuries to the tool’s user.
Rivit S.r.l. assumes responsibilities only if the tool is originally defective, but declines all forms of re-
sponsibility if the user fails to follow the given instructions.
16 | 40 REV | 02
RIV 504 EN
TECHNICAL DATA
In case of assistance
please specify the serial
number on the external
case
REV | 02 17 | 40
EN RIV 504
ACCESSORIES SUPPLIED
Open valve
Close valve
18 | 40 REV | 02
RIV 504 EN
ACCESSORIES ON REQUEST EN
A B
Ø 23
91
100
A B
Ø 23
195
200
To get the 100 mm and the 200 mm extensions you need to disassemble the parts and assemble the
new correspondent ones (A and B) in the same sequence.
REV | 02 19 | 40
EN RIV 504
SAFETY MEASURES
• Use the riveting tool properly and for the purposes for which it has been manufactured.
• Any kind of modification made on the riveting tool and its equipment by the customer itself, will be
done under the fully responsibility of the customer. In this case, Rivit srl declines any responsibility.
• The riveting tool must be always kept in safety conditions and must be revised at regulkar intervals
by expert and authorized workers, following the maintenance producers of Rivit srl.
• The riveting tool will always be used following the EC normative "on health and safety measures
on job" (Directive 2006/42/EC). Any problem or information regarding the correct operating of the
tool, will have to be returned to Rivit srl.
• The safety measures to be observed during the use of the riveting tool, must be explained from
the customer to all users. Always detach the air feeding from the take-off point of the toll before
regulating, repairing and cleaning operations.
• Dont'use the tool if is turned towards other persons.
• Operating pressure have not to exceed 7 bar - 100 LBF/IN2.
• Make sure that the air discharges are not blocked or covered and the feeding hoses are always in
good working conditions.
• The operations of maintenance, repairing and cleaning must be done when the tool is not fed.
• When using the riveting tool, wear protective glasses or visors and gloves.
• Use only original spare parts for repairing and maintenance. Rivit srl declines any responsibility
for any kind of damages caused by not observing the above and following instrucions (directive
CEE 85/734).
• If the noise level is over the safety limit of 85 dB (A), use the proper hearing protections (antinoise
headset etc.).
OPERATING INSTRUCTIONS
Air feed
All the tools works with compressed air, with a pressure of 6 bar.
We suggest to use regulators of pressure and automatic filtering systems on the main net of feeding air.
These will have to stay to 3 meters of distance from the tool (see the drawing), in order to assure an
optimal pressure in the tool and its maximum duration-life with a minimum maintenance.
The flexible tubes for the air compressed in entrance must be in a position to supporting a pressure
of 10 bars and will have to be resistant to the oil, covered of a material resistant to the abrasions and
protected in case bad job conditions could damage them.
All the flexible tubes for the compressed air must have a diameter of minimum passage of 6,4 mm or
1
/4 of inch.
The pressure regulator must be set up to 6,5 bars in consideration of the pressure fall.
20 | 40 REV | 02
RIV 504 EN
Maintenance
Check the grip of the jaws on the rivet's nail.
If it is anomalous, this is due to a problem on the jaws: dirty jaws or wear of the jaws.
In the first case, proceed with cleaning and oiling the jaws; in the second case, it is necessary to sub-
stitute the jaws with new ones.
In order to do these operations, first of all, disconnect the air feeding; then remove the head carrying
nosepiece with a 26 mm spanner.
Then with 16 mm and 17 mm spanner keep off the cone holding jaws and proceed with cleaning or
changing the jaws.
Check the air pressure, which don't have to exceed 7 bar.
Check eventual losses of oil or air.
Check the stroke of the riveting tool. If it is anomalous, proceed with topping up new oil.
REV | 02 21 | 40
EN RIV 504
Oil topping up
OIL TOPPING UP
The topping up of the oil is necessary when occurs a power loss of the riveting tool or after a long
period of use.
Proceed as per the following instructions:
• Disconnect the air supply from the tool and keep the tool in a vertical position.
• Remove oil screw using a 3 mm allen wrench, screw the oil syringe (equipped) until it makes no
resistance, use oil viscosity 32°.
• Remove the syringe, then screw the oil screw with its o-ring and tighten.
• Place air without pressing the trigger.
• Unscrew the screw slowly so that the exceeding oil comes out (bleeding).
• Tighten screw.
• The tool is ready.
• N.B. In case of doubt check stroke, whose regulation should never be lower than the technical data.
N.B. During the operation, wear protective gloves and don't waste oil in the environment. In case of
contact of oil with skin, wash carefully the part with water and soap.
32 42253 1 O-ring
33 41359 1 Nail collector lid
34 41360 1 Nail collector body
36 41729 1 Silencer
37 41733 1 Collector lock
38 41730 1 Silencer
39 41734 1 Collector cap
• Recomended spare parts