Design Rules
Inverters connected to the delta grid will operate with reduced AC power rating, due to the lower grid voltage; for full
specifications refer to the inverter datasheets:
l SE6K-SE12.5K
l SE15K-SE27.6K
The following table details PV system design using the SE6K- SE27.6K inverters in delta grids.
SE6K-
SE15K SE16K-SE27.6K
SE12.5K
P300- P300- P300-
Compatible Power Optimizers P600 P600-P700 P800
P500 P500 P500
Minimum String Length (Power
10 / 10 10 / 10 8 / 16 10 / 10 8 / 16 8 / 16
Optimizers / Modules)
Maximum String Length (Power
25 / 25 25 / 25 30 / 60 25 / 25 30 / 60 30 / 60
Optimizers / Modules)
Maximum Power per String 6000 7200
NOTE
Perform this procedure before connecting the inverter Safety Switch (if applicable) to the AC grid.
1. Remove the inverter cover: Open the inverter cover’s six Allen screws and carefully pull the cover horizontally before
lowering it.
2. Identify the fuse locations and the markings as described in Figure 1.
1
Setting the Inverter to Support Delta Grids