0% found this document useful (0 votes)
230 views2 pages

Fire 1 & 2: Ef1-Ann

This document provides information on the Evax Fire 1 and Fire 2 fire alarm control panels (FACPs) and their features. The Fire 1 can support up to 1008 addressable devices across 8 loops, while the Fire 2 is limited to 252 devices across 2 loops. Both support conventional detection and can connect up to 15 (Fire 1) or 7 (Fire 2) remote LCD annunciators. The FACPs support features like alarm verification, sensitivity settings, relay outputs, and remote programming. The included EF1-ANN remote annunciator module provides LCD status indication and keypad control of the FACP.

Uploaded by

Daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
230 views2 pages

Fire 1 & 2: Ef1-Ann

This document provides information on the Evax Fire 1 and Fire 2 fire alarm control panels (FACPs) and their features. The Fire 1 can support up to 1008 addressable devices across 8 loops, while the Fire 2 is limited to 252 devices across 2 loops. Both support conventional detection and can connect up to 15 (Fire 1) or 7 (Fire 2) remote LCD annunciators. The FACPs support features like alarm verification, sensitivity settings, relay outputs, and remote programming. The included EF1-ANN remote annunciator module provides LCD status indication and keypad control of the FACP.

Uploaded by

Daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Series

Fire 1 Series FACP FEATURES: FIRE 1 & 2


·Digital Addressable EF1-ANN
·Addressable & Conventional inputs Remote Annunciator
·Modular in design
·126 Addressable devices per Loop
·8 Addressable Loops
·1008 Addressable Devices
·15 remote LCD Annunciators (Fire 1)
·8 remote LCD Annunciators (Fire 2)
·Day / Night sensitivity settings
·Alarm Verification
·Automatic Drift Compensation
·4 NAC circuits
·7 Amps Power Supply
·Remote programming option
·Panel to Panel Network capable
·Holiday Scheduling
·60 Conventional Zones
·6,000 ft extended addressable loop
option 3127525 FACP
7170-1446:107 3127886 LCSS
·Flash / Non-Flash detector LED option 7165-1446:106

·Constant Power NAC option


The Remote Annunciator is intended for surface or
flush mounting and includes the Remote
Annunciator module that is placed inside the
cabinet.
DESCRIPTION:
EF1-ANN module contains:
The Evax Fire 1 & Fire 2 are sophisticated
microprocessor-based analog addressable fire ·Graphical LCD display 64x128
alarm control system suited to the various needs of points with LED backlight.
commercial, industrial and institutional
·17 key keyboard.
applications. The Fire 1 provides the ability to
“software” configure and label 1008 Apollo or 1584 ·25 System Status LEDs
System Sensor Signal Line Circuits (SLC) points
plus system and network points. It functions as a
manual, automatic and water flow control system EF1-ANN module provides the following functions:
for local, central station, and remote station
applications. Activation of a compatible sensor or ·Indication by LCD screen of the system
normally open fire alarm initiating devices will events and input/output system
sound audible appliances, notify a remote station, configuration parameters.
annunciate a fire or alarm condition, and energize · LCD indication font 6x8 points.
supplementary relays. The Fire 2 is limited to 252 · Characters numbers 160 (8 lines x 20
Apollo or 396 System Sensor points on two SLC’s. characters).
· Multi language options - according to the
Remote Annunciator: customer order.
· System command entering by keyboard
The Evax Fire 1 Series FACP’s allows connection · System status indication by LEDs
of remote Display Annunciators (EF1-ANN). The · Communication with main Panel by
total Remote Annunciator quantity that can RS485 internal network
connect to one Panel is 15 for a Fire 1 and 7 for a · Nominal power supply voltage - 24 VDC
Fire 2.

20 McDermott Road, Branford, CT 06405 203-315-5116 FAX 203-315-5118 WWW.EVAX.COM


Dimensions:

8.50
Backbox: 10” x 8 5/8”

Front Plate: 11 ½” x 10”

Finish: Red
2.00

10.00 EF-290-0061

How to Order: EF2-MBC Fire 2 Common System components


EF1 2 Loop expandable Addressable (MCCLC, PDC, PC & Power Supply)
FACP Apollo and/or System Sensor 115/230VAC 50-60HZ
Protocol w/ RED cabinet 1115/230VAC
50-60HZ EF1-RC 2 Form C relay board- connects to
MCC or EF1-CM
EF1-10C 10 Zone Conventional FACP w/ RED EF1-RCCBL Flat ribbon cable for the EF1-RC connect
cabinet 115/230VAC 50-60HZ to MCC or EF1-CM board
EF1-KIT Mounting Hardware kit for adding LC/CM
EF2 2 Loop non-expandable Addressable cards into Expander panels
FACP Apollo and/or System Sensor EF1-USB-CBL FIRE 1 & 2 Laptop USB Programming
Protocol w/ RED cabinet 115/230VAC Cable, USB A to USB B mini
50-60HZ

EF-UDACT SIA1 Protocol Universal Digital Alarm


Communicator Transmitter Engineering Specification
EF1-CAB FIRE 1&2 Cabinet only
backbox & door, RED The Fire Alarm Control Panel (FACP) shall be Addressable
EF1-CABG FIRE 1&2 Cabinet only loop and Conventional Zone capable. Standard FACP shall
Backbox & door, GRAY be two (2) loops of addressable circuits expandable to eight
(8). The system shall be capable of 126/198 Apollo/System
EF1-2EXP 2 Addressable Loop expander Apollo Sensor addressable devices per loop for a total of
and/or System Sensor Protocol w/
1008/1584 addressable devices. Each expander module
cabinet
EF1-4EXP 4 Addressable Loop expander Apollo
shall add an addition 2 addressable loops or 10 conventional
and/or System Sensor Protocol zones. These expander cards shall be housed in their own
w/ cabinet cabinets and be capable of being remotely located up to
EF1-10C-EXP 10 Class B or 5 Class A Conventional 6,000 feet from the main FACP. The main FACP shall
Zone expander w/ cabinet communicate with addressable devices in both digital and
analog communication formats. System shall have auto
EF1-LC 2 Addressable Loop expander program capability, sensitivity adjustments, day/night
board only, Apollo and/or System
sensitivity, holiday scheduling, off site programming and
Sensor Protocol
troubleshooting, shall be capable of adding internal Form “C”
EF1-CM 10 Class B or 5 Class A Conventional relay contacts housed in the main FACP cabinet, and be
Zone expander, Board only capable of automatic drift compensation. System shall be
EF1-EXP-CAB Expander Cabinet only, backbox & programmed using propriety software or from the main
door FACP. Panel shall have the ability to add up to 15 (Fire 1) or
7 (Fire 2) remote LCD/LED Annunciators utilizing digital
EF1-ANN Remote LCD/LED Annunciator in communications. Panel shall charge up to 40 A-H’s of
Cabinet
standby batteries without the use of an external power
EF1-RAN Remote LCD/LED Annunciator Board
only
supply. The panel shall contain four (4) on-board Notification
EF1-ANN-CAB Remote Annunciator Cabinet only Appliance Circuits (NACs) that support multiple
synchronization protocols or can be programmed as auxiliary
EF1-MBC Fire 1 Common System components power. The panel shall utilize a 8 x 20 character Liquid
(MMC, PDC, PC & Power Supply) Crystal Display (LCD) with LED backlight and a 1,000-event
115/230VAC 50-60HZ history log. The panel shall be an Evax FIRE 1 or Fire 2
with EF1-ANN Remote Annunciator.

Specifications are subject to change without notice. Specifications


are provided for information only and no responsibility is assumed
by Evax Systems, Inc for their use.

EF1-ANN Rev D (06.10)


Series