PACKHOUSE

Doc. No. PKH-FOR-005


Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 7-Sep-20 TAG NO. : 161104


TYPE: Rotopacker DESCRIPTION: Rotopacker #1

BRAND: Haver & Boecker TEST WEIGHTS(KGS): 39.87


MODEL: 8RSE INSTRUMENT RANGE: 0 - 200KGS
S/N: 50/311740/02 TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.58 39.94 0.00 39.87 -0.18 Calibrated
1
0.48 39.86 0.00 39.87 0.03 Calibrated
2
0.15 39.08 0.00 39.87 1.98 Calibrated
3
0.66 39.14 0.00 39.87 1.83 Calibrated
4
0.37 39.78 0.00 39.87 0.23 Calibrated
5
0.90 39.61 0.00 39.87 0.65 Calibrated
6
0.02 39.55 0.00 39.87 0.80 Calibrated
7
0.84 39.48 0.00 39.87 0.98 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
- - - - - - No Checkweigher

Notes:

All spouts were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 8-Sep-20 TAG NO. : 162104


TYPE: Rotopacker DESCRIPTION: Rotopacker #2

BRAND: Haver & Boecker TEST WEIGHTS(KGS): 39.87


MODEL: 8RSE INSTRUMENT RANGE: 0 - 200KGS
S/N: 50/311740/03 TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.66 39.98 0.00 39.87 -0.28 Calibrated
1
0.58 39.81 0.00 39.87 0.15 Calibrated
2
0.48 39.48 0.00 39.87 0.98 Calibrated
3
0.90 39.86 0.00 39.87 0.03 Calibrated
4
0.71 39.05 0.00 39.87 2.06 Calibrated
5
0.50 39.16 0.00 39.87 1.78 Calibrated
6
0.16 39.47 0.00 39.87 1.00 Calibrated
7
0.94 39.58 0.00 39.87 0.73 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
- - - - - - No Checkweigher

Notes:

All spouts were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 9-Sep-20 TAG NO. : 163104


TYPE: Rotopacker DESCRIPTION: Rotopacker #3

BRAND: Haver & Boecker TEST WEIGHTS(KGS): 39.87


MODEL: 8RSE INSTRUMENT RANGE: 0 - 200KGS
S/N: 50/311740/01 TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.25 39.53 0.00 39.87 0.85 Calibrated
1
0.18 39.61 0.00 39.87 0.65 Calibrated
2
0.99 39.47 0.00 39.87 1.00 Calibrated
3
0.65 39.58 0.00 39.87 0.73 Calibrated
4
0.48 39.78 0.00 39.87 0.23 Calibrated
5
0.37 39.07 0.00 39.87 2.01 Calibrated
6
0.19 39.28 0.00 39.87 1.48 Calibrated
7
0.58 39.47 0.00 39.87 1.00 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
- - - - - - No Checkweigher

Notes:

All spouts were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 10-Sep-20 TAG NO. : 164104


TYPE: Rotopacker DESCRIPTION: Rotopacker #4

BRAND: Haver & Boecker TEST WEIGHTS(KGS): 39.87


MODEL: 8RCC INSTRUMENT RANGE: 0 - 200KGS
S/N: 50/415716/01 TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.74 39.09 0.00 39.87 1.96 Calibrated
1
0.66 39.40 0.00 39.87 1.18 Calibrated
2
0.34 39.66 0.00 39.87 0.53 Calibrated
3
0.98 39.78 0.00 39.87 0.23 Calibrated
4
0.15 39.08 0.00 39.87 1.98 Calibrated
5
0.80 39.44 0.00 39.87 1.08 Calibrated
6
0.29 39.58 0.00 39.87 0.73 Calibrated
7
0.47 39.48 0.00 39.87 0.98 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
- - - - - - No Checkweigher

Notes:

All spouts were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 11-Sep-20 TAG NO. : 165104


TYPE: Rotopacker DESCRIPTION: Rotopacker #5

BRAND: Haver & Boecker TEST WEIGHTS(KGS): 39.87


MODEL: 8RCC INSTRUMENT RANGE: 0 - 200KGS
S/N: Z.000086-01-30-01 TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.15 39.51 0.00 39.87 0.90 Calibrated
1
0.74 39.14 0.00 39.87 1.83 Calibrated
2
0.51 39.80 0.00 39.87 0.18 Calibrated
3
0.69 39.86 0.00 39.87 0.03 Calibrated
4
0.59 39.76 0.00 39.87 0.28 Calibrated
5
0.86 39.48 0.00 39.87 0.98 Calibrated
6
0.43 39.20 0.00 39.87 1.68 Calibrated
7
0.27 39.84 0.00 39.87 0.08 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
- - - - - - BYPASS

Notes:

All spouts were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 12-Sep-20 TAG NO. : 166104


TYPE: Rotopacker DESCRIPTION: Rotopacker #6

BRAND: Haver & Boecker TEST WEIGHTS(KGS): 39.87


MODEL: 8RCC INSTRUMENT RANGE: 0 - 200KGS
S/N: Z.000086-01-30-02 TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.52 39.40 0.00 39.87 1.18 Calibrated
1
0.18 39.82 0.00 39.87 0.13 Calibrated
2
0.78 39.85 0.00 39.87 0.05 Calibrated
3
0.69 39.96 0.00 39.87 -0.23 Calibrated
4
0.48 39.41 0.00 39.87 1.15 Calibrated
5
0.36 39.83 0.00 39.87 0.10 Calibrated
6
0.47 39.69 0.00 39.87 0.45 Calibrated
7
0.96 39.48 0.00 39.87 0.98 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
- - - - - - BYPASS

Notes:

All spouts were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 13-Sep-20 TAG NO. : 167104


TYPE: Rotopacker DESCRIPTION: Rotopacker #7

BRAND: Haver & Boecker TEST WEIGHTS(KGS): 39.87


MODEL: 8RCC INSTRUMENT RANGE: 0 - 200KGS
S/N: Z.000086-01-30-03 TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.58 39.53 0.00 39.87 0.85 Calibrated
1
0.47 39.74 0.00 39.87 0.33 Calibrated
2
0.15 39.89 0.00 39.87 -0.05 Calibrated
3
0.37 39.26 0.00 39.87 1.53 Calibrated
4
0.48 39.47 0.00 39.87 1.00 Calibrated
5
0.96 39.68 0.00 39.87 0.48 Calibrated
6
0.80 39.41 0.00 39.87 1.15 Calibrated
7
0.48 39.58 0.00 39.87 0.73 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
- - - - - - BYPASS

Notes:

All spouts were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 14-Sep-20 TAG NO. :


TYPE: Rotopacker DESCRIPTION: Rotopacker #8

BRAND: FLS Ventomatic TEST WEIGHTS(KGS): 42.27


MODEL: Giromat Evo V8 INSTRUMENT RANGE: 0 - 200KGS
S/N: TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.56 42.19 0.00 42.27 0.19 Calibrated
1
0.25 42.70 0.00 42.27 -1.02 Calibrated
2
0.14 42.60 0.00 42.27 -0.78 Calibrated
3
0.58 42.31 0.00 42.27 -0.09 Calibrated
4
0.78 42.38 0.00 42.27 -0.26 Calibrated
5
0.49 42.23 0.00 42.27 0.09 Calibrated
6
0.93 42.18 0.00 42.27 0.21 Calibrated
7
0.84 42.60 0.00 42.27 -0.78 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.18 42.24 0.00 42.27 0.07 Calibrated

Notes:

All spouts and ventocheck were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 15-Sep-20 TAG NO. :


TYPE: Rotopacker DESCRIPTION: Rotopacker #9

BRAND: FLS Ventomatic TEST WEIGHTS(KGS): 42.27


MODEL: Giromat Evo V8 INSTRUMENT RANGE: 0 - 200KGS
S/N: TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.00 42.27 0.43 Calibrated
1 0.17 42.09
0.00 42.27 0.05 Calibrated
2 0.19 42.25
0.00 42.27 0.35 Calibrated
3 0.23 42.12
0.00 42.27 -1.47 Calibrated
4 0.42 42.89
0.00 42.27 -0.21 Calibrated
5 0.18 42.36
0.00 42.27 0.21 Calibrated
6 0.48 42.18
0.00 42.27 -0.99 Calibrated
7 0.75 42.69
0.00 42.27 -0.02 Calibrated
8 0.64 42.28

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.24 42.29 0.00 42.27 -0.05 Calibrated

Notes:
All spouts and ventocheck were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 16-Sep-20 TAG NO. :


TYPE: Rotopacker DESCRIPTION: Rotopacker #10

BRAND: FLS Ventomatic TEST WEIGHTS(KGS): 42.27


MODEL: Giromat Evo V8 INSTRUMENT RANGE: 0 - 200KGS
S/N: TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.52 42.26 0.00 42.27 0.02 Calibrated
1
0.41 42.58 0.00 42.27 -0.73 Calibrated
2
0.78 42.90 0.00 42.27 -1.49 Calibrated
3
0.69 42.18 0.00 42.27 0.21 Calibrated
4
0.48 42.87 0.00 42.27 -1.42 Calibrated
5
0.26 42.29 0.00 42.27 -0.05 Calibrated
6
0.33 42.84 0.00 42.27 -1.35 Calibrated
7
0.51 42.18 0.00 42.27 0.21 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.54 42.21 0.00 42.27 0.14 Calibrated

Notes:

All spouts and ventocheck were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent


PACKHOUSE
Doc. No. PKH-FOR-005
Effective Date: dd/Mon/yyy
Revision No.: 00

ROTOPACKER CALIBRATION RECORD

DATE: 17-Sep-20 TAG NO. :


TYPE: Rotopacker DESCRIPTION: Rotopacker #11

BRAND: FLS Ventomatic TEST WEIGHTS(KGS): 42.27


MODEL: Giromat Evo V8 INSTRUMENT RANGE: 0 - 200KGS
S/N: TOLERANCE: ±1%

Spout No. AS FOUND-DISPLAY RESULT-DISPLAY


VALUE(KGS) VALUE(KGS) Deviation Remarks
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.21 42.18 0.00 42.27 0.21 Calibrated
1
0.58 42.41 0.00 42.27 -0.33 Calibrated
2
0.66 42.49 0.00 42.27 -0.52 Calibrated
3
0.47 42.36 0.00 42.27 -0.21 Calibrated
4
0.48 42.15 0.00 42.27 0.28 Calibrated
5
0.18 42.23 0.00 42.27 0.09 Calibrated
6
0.65 42.15 0.00 42.27 0.28 Calibrated
7
0.91 42.87 0.00 42.27 -1.42 Calibrated
8

Check AS FOUND-DISPLAY RESULT-DISPLAY Deviation Remarks


Weigher VALUE(KGS) VALUE(KGS)
No Test With Test With Test
No Test Weight
Weight Weight Weight
0.18 42.31 0.00 42.27 -0.09 Calibrated

Notes:

All spouts and ventocheck were calibrated. For testing.

Calibrated By: Noted By: Approved By:

Instrumentation Engineer Instrumentation Supervisor Packhouse Superintendent