Datasheet SMART e English Rev1
Datasheet SMART e English Rev1
Datasheet SMART e English Rev1
Document Rev1
Datasheet LOGIC
Control unit for
office
an Electric
Height-Adjustable
Desk
Contents
1 Features ............................................................................................................................................... 3
2 Type and dimensions ........................................................................................................................... 4
3 Technical Data ..................................................................................................................................... 5
3.1 Pin assignment ............................................................................................................................ 6
3.1.1 Motor socket ........................................................................................................................... 7
3.1.2 Handswitch socket .................................................................................................................. 7
3.2 Intelligent System Protection (ISP) – Anti Pinch ......................................................................... 8
3.3 Type plate ................................................................................................................................... 8
4 Accessories ....................................................................................................................................... 10
5 Order code ......................................................................................................................................... 10
6 End of life disposal ............................................................................................................................. 10
7 Standards .......................................................................................................................................... 11
8 Manufacturer ...................................................................................................................................... 11
2
1 Features
• High efficient switch mode power supply (SMPS)
• Low standby power consumption, low field emission
• Control units with US and EU input voltage available
• Table height display with configurable offset
• Up to 6 memory positions (depending on handset)
• ISP (Intelligent System Protection)
• Enhanced Drive Comfort
• Safety area
• Low speed area
• Plug detection
• Configurable reset conditions
• Configurable stop conditions (overtemperature, overcurrent, timeout, limit switches)
• Additional functions are available, depending on the handswitch model used
(e.g. saving desktop positions, adjusting the desktop to saved positions, etc.)
• A wide selection of LOGICDATA handswitches is available for the control units
• Clip-On Handswitch: SmartTOUCH-OD-2-LD
Caution: do not open the SMART-e control unit under any circumstances. There is a danger
of electric shock.
Caution: only use the power cord supplied with the control unit. Check that it is not damaged.
Do not ever operate the SMART-e control unit if the power cord is damaged.
Caution: the SMART-e control unit may only be operated with mains voltage as specified on
the type plate.
SMART-e control units are also available for the mains voltages used in other countries.
Detailed information is provided in the datasheet!
Danger: The control unit must be mounted before commissioning and operation.
Caution: When installing the SMART-e and putting it into operation, be sure that the SMART-
e is acclimatized to the temperature and humidity values for operation, shown in the
datasheet!
Caution: do not open the SMART-e control unit under any circumstances. There is a danger
of electric shock.
Danger: in the event of a fault, please contact customer service immediately. Only original
spare parts may be used for repairing the control units. Parts may only be replaced by
qualified service technicians, otherwise the warranty/guarantee shall be null and void.
Danger: do not expose the SMART-e control unit to moisture, drips or splashes.
3
Caution: only clean the SMART-e control unit with a dry or slightly moist cloth. Before
cleaning, you must always unplug the power cord.
Caution: unplug the power cord during a thunderstorm or if you do not intend to use the desk
for a longer period. The control unit might otherwise be damaged by power surges.
Danger: if strange smells or fume occur, unplug the power cord immediately. Contact
LOGICDATA.
Note: information about usage of the SMART-e can be found in the user manual which is
valid for the firmware version of the SMART-e-1. The user manuals for SMART-e+-1,
SMART-e-1, SMART-e+-2 and SMART-e-2 are identical.
A drill template can be found in the Mounting Instructions, available as separate document.
4
3 Technical Data
General
Supply voltage EU: 207-253 V / 50-60Hz
US: 90-127V / 50-60Hz
Nominal voltage EU: 230V / 50 Hz
US: 120V / 60Hz
Standby power, primary (typical) ≤0,3 W
Operating voltage for internal and external electronics 5VDC ±15% 250mA
and Hall sensors
Operating voltage for internal and external electronics 5VDC ±15% 7mA
and Hall sensors in standby mode (average)
Precision of Motor current measurement
@ 100% Output Voltage and 4-8A ±15%
Ambient temperature 0-30°C
Relative humidity (for operation) 5-85% (non condensing)
Storage and transport temperature -40-85°C
Relative humidity (for storage) 5-90% (non condensing)
Protection class (with earth terminal) I
IP class ≥IP 20
Dimensions (L x B x H) [mm] 186 x 100 x 30
SMART-e-1
Switching cycles Normal cycle 1/9:
30s UP: 8A@27V 216W
Depicted currents are sums over all motor channels 30s DOWN: 4A@32V 128W
Pause: 9min
SMART-e-2
Switching cycles Normal cycle 1/9:
30s UP: 9A@24V 216W
Depicted currents are sums over all motor channels 30s DOWN: 4A@32V 128W
Pause: 9min
5
Life Cycle (Switching cycles) 10.000
Max. allowed button force 50N
Ambient temperature 0-30°C
Relative humidity (for operation) 5-85% (non condensing)
Storage and transport temperature -40°C - +85°C
Relative humidity (for storage) 5-90% (non condensing)
Dimensions (L, B, H) [mm] 58 x 46 x 25mm
Tolerances according to DIN ISO 2768-1 c
Weight 18g
Figure 2: Sockets
Motor socket 1 (M1)
Motor socket 2 (M2) (only for SMART-e-2)
S Handswitch socket (HS)
P Mains socket
HS Clip-On Handswitch: SmartTOUCH-OD-2-LD (optional)
6
3.1.1 Motor socket
Danger: to prevent damage of the unit, use only motors/ motor cables suitable for
LOGICDATA motor controls.
Pin Description
Motor+ / Motor - Power supply lines for motors
Hallsensor 1,2 Sensor input lines for hall sensors
+5V, GND Power supply lines (e.g. for hall sensors)
SYN Reserved
Limit Switch 1,2 Digital sensor input lines for limit switches
Danger: please observe the maximum allowable loads (currents) for the 5V circuit in normal
operation and standby, shown in the technical data. The load sum attached on all interfaces
of the control unit must not exceed the values for the particular operating state!
1 RxD 5 HS2
2 HS3 6 TxD
3 HS1 7 +5V
4 HS4 Shell GND
Figure 4: Pin assignment of handswitch socket; pin alignment according to DIN 45329
Danger: to prevent damage of the unit, use only handswitches suitable for LOGICDATA
motor controls.
Pin Description
TxD / RxD Pins for communication
(LOGICDATA communication protocol)
+5V, GND Power supply lines for handswitch
HS X Parallel handswitch input lines
Danger: please observe the maximum allowable loads (currents) for the 5V circuit in normal
operation and standby, shown in the technical data. The load sum attached on all interfaces
of the control unit must not exceed the values for the particular operating state!
Note: please contact LOGICDATA for information about the coding of the parallel
handswitch input lines.
7
3.2 Intelligent System Protection (ISP) – Anti Pinch
Pay attention to the following instructions if you are using the new anti-pinch feature ISP ( = Intelligent
System Protection).
To ensure the best possible pinch protection, a mechanical brake must be fitted that is
applied when the electric height-adjustable desk moves down.
Note: without a mechanical brake, cut-out sensitivity may be reduced under load. However, if
there is no load on the desktop, ISP will function properly even without a brake.
Note: the ISP-sensitivity and the ISP-cutoff value depend on the whole system (mechanical
and electrical components). To evaluate the ISP-capability of a height adjustable table,
please contact LOGICDATA!
Danger: in spite of ISP being in place, there may still be a risk of pinching in exceptional
cases, as it is not only the control unit, but also the interaction between the mechanical and
electronic systems that is responsible for cutting out the motor. In addition, the mechanical
components, motor and ambient conditions all affect cut-out sensitivity.
As the control unit manufacturer, LOGICDATA cannot therefore eliminate this residual risk
completely or accept any liability.
Note: specifications on the type label are dependent on the version of the SMART-e control
box (see technical data).
8
Figure 6: Type plate of SMART-e-1 EU Type
9
4 Accessories
LOGICDATA offers a wide range of optional accessories. Please contact LOGICDATA to get a catalogue
with all LOGICDATA products.
5 Order code
SMART-e-N-x-y-z
0,3W Standby power
1...For 1 motor
2...up to 2 motors
Up to 10 alphanumeric characters for motor type (optional)
Note: The SMART-e control unit is electrical or electronic equipment according to directive
2002/96/EC and therefore marked with the symbol depicted on the left.
Note: ensure eco-friendly disposal of all the control unit components (separate the plastic and
electronic parts for collection).
Also ensure eco-friendly disposal of all the other components (drives, cables, etc.).
10
7 Standards
Europe
• EN 60335-1:2012 (IEC 60335-1:2010 Fifth Edition)
• DIN EN ISO 13849-1: 2008, Kategorie B, Performance Level b
• DIN EN 62233:2008
• DIN EN 61000-6-3:2007+A1:2011
• DIN EN 61000-6-2:2005
Note: this product is REACH compliant according to directive 2006/121/EC (Edict 1907/2006)
8 Manufacturer
LOGICDATA Tel.: +43 (0)3462 5198 0
Electronic & Software Entwicklungs GmbH Fax: +43 (0)3462 5198 530
Wirtschaftspark 18 Email: [email protected]
A-8530 Deutschlandsberg - Austria URL: www.logicdata.at
11