Installation Manual STx Switch
EAE KNX Rosa Switch Series Rosa IM R1.0
Operation and Display Installation
Installation of the product is done with the help of the flange which is inside the box. The flange is fixed to the junction box by using screws while the arrows on flange are headed to up. The switch is placed into the junction box by positioning the EAE logo upwards and then reclining it to the flange. The switch is slowly turned clockwise to give the right position to it on the flange. After the clicks are on the right position, switch is turned counter-clockwise to lock it on the flange.
Locking Direction (CCW)
Locking Direction (CCW)
Description of the Device
Rosa premium push-button and thermostat series create a natural harmony and adds value to your interior designs with elegant look and sophisticated technology. Combined with KNX system, use of a single Rosa switch would provide you the means to activating light scenes, controlling blinds and setting a comfortable temperature. Rosa series Commissioning which combine the familiar push button feeling with the latest Device default physical address is 15.15.255. Determination of the technology are available in anthracite, ivory and cloud gray colours. physical address and setting of parameters are actualized with Engineering Tool Software (ETS3/ETS4 or higher). “.knxprod” file must be • 60x60 mm easy mounting to standard junction boxes. imported to the ETS. (http://www.eaetechnology.com/) • 4 rockers can be programmed to perform different functions. A detailed information about parameter configuration can be found ▪ Switching ▪ Value in Product Manual of device. ▪ Dimming ▪ Scene control Installation and commissioning of device may only be implemented ▪ Shutter/Blind ▪ Status notification by trained electricians. The relevant standards, directives, regulations Technical Data and instructions must be observed when planning and implementing the Type of protection IP 20 -EN 60 529 electrical installation. Safety class II -EN 61 140 -When connecting the device make sure that the device can be isolated! KNX Supply (1) - Voltage 21 V… 30 V DC SELV - Current Consumption ≤ 10 mA -Protect the device against moisture, dirt and damage during transport, Connections -KNX Bus connection terminal storage and operation! Installation 60x60 mm standard box Temperature range Ambient -5° C + 45° C -Do not operate the device out of the specified technical data which is Storage -25° C + 55° C stated. Humidity Max. air humidity 95 % no moisture condensation -The device may only be operated in closed enclosures (Distribution Dimensions Front face 85x85 mm boards) Side- Surface 11 mm Side- Under plaster 19,4 mm Cleaning Weight 93 g If device becomes dirty, only a dry cloth can be used for cleaning. İt is not Box Plastic, polycarbonate suitable to use wet cloths, caustics and solvents. CE In accordance with the EMC guideline and low voltage Application Program Communication Objects -50 Number of Addresses(max) -254 Number of assignments(max) -255