LDC6 275
LDC6 275
LDC6 275
Electrical Specifications
Capacity (AH) Reserve Capacity (Min)
Voltage(V)
100HR 20HR 10HR 5HR 3HR @25A @56A @75A
Physical Specifications
Dimensions (mm/inches)
Model Weight (kg/Ibs) Terminal Type Case Material
Length Width Height Total Height (Standard)
LDC6-275 295 (11.61) 180 (7.09) 274 (10.79) 296 (11.65) 36.5 (80.5) DT-5/16 PP
MEMBER
LDC6-275
Dimensions
DT-5/16 Terminal
D 5/16"
17
22
20
180±2
DEEP CYCLE AGM BATTERY
274±2
296±2
30 24
295±2
37.5 ±0.1
0 0
Note: D:Positive 19.5 -0.3 , D:Negative 17.9-0.3 ; Terminal Torque Values in-Ib(Nm) :176-203(20-23)
Performance Characteristics
LEOCH LDC AGM Charging Profile Relationship of OCV and State Of Charge (25℃,77℉)
2.25
2.20
2.15
Battery voltage (V/cell)
2.10
2.05
2.00
1.95
1.90
0 10 20 30 40 50 60 70 80 90 100
State of Charge(%)
120
100 No supplementary
charge required(Carry
100 90 out supplementary
charge before use if
0 o C / 32℉ 100% capacity is required
80 80
Capacity(%)
Capacity(%)
Supplementary charge
70 required before use to
60 recover full capacity.
50
80%DOD 50%DOD 30%DOD 60
40 20 o C / 68℉ Supplementary charge
o o may often fail to recover
40 C / 104℉ 30 C / 86℉
the capacity. The battery
50 should never be left
20
standingtill this is
reached.
40
0 2 4 6 8 10 12 14 16 18 20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Storage time(months) The Max storage time shouldn’t be above 15 months
Average Cycles Expected