Psychrometer sensor
Wet&Dry forced ventilation temperatures sensor.
Design made according to ISO7726 standard
Direct calculation of the Relative Humidity and Dew
Point using LSI-LASTEM’s data logger according to
ISO7726 standard
2% accuracy assured over the whole range (0-100%)
and wide operative temperature (0...60°C)
High accuracy Pt100 1/3 DIN B sensitive elements
Forced ventilation on the sensitive elements: >2 m/s
Long term stability and robust principle. Applications
in polluted/salty air even near the saturation with high
temperatures
Psychrometer sensor with wet&dry bulbs and forced ventilation. Wet bulb is closed inside a wet cotton sock from a distilled
water tank. This sensor has a very good stability because it is based on a direct measurement of temperature using 1/3 DIN
element and it is not sensitive to the time drift of commonly used capacitive hygrometer elements. LSI-LASTEM data loggers
can calculate Relative Humidity starting from wet&dry temperatures.
Technical Specifications
PN ESU102
Temperature Principle Wet&Dry bulbs with forced ventilation Pt100 1/3 DIN B
Measuring range -5...60°C
Accuracy 0.10°C (@ 0°C)
Output 2xPt100 DIN-IEC 751 table (EN 60751)
Resolution 0.01°C (M/R/E-Log)
Response time (T90 Air) 1.5 min
Relative Humidity % Principle Psychrometric
Measuring range 0...100%
Accuracy 2% (5...45°C)
Resolution 1%
Response time (T90 Air) 1.5 min
General Information Protection grade IP54
Ventilation on the sensitive > 2 m/s
elements
Power consumption 30 mA (forced ventilation on)
Operative temperature 0...60°C
Cable L=1 m
Connector Double min-din
Input type on E/M-Log N. 2 analog
E/M-Log derived quantities • Pyshrometric Relative humidity
obtained
• Dew point
Mounting On BVA305-315 stands or on table
MW9001-ENG-07-13/02/2023
1
Psychrometer sensor
Accessories
There are several reasons to select psychrometer (wet&dry bulbs) or capacitive sensors to measure Relative Humidity. Here
above the list of advantage and disadvantage for both technologies:
Water consumption No water Water must always be inside the water tank
Measurement below 0°C Can be used below 0°C Cannot be used below 0°C (because of the
water presence in the tank)
Measurement at high temperature Cannot discriminate when RH is above Can discriminate even above RH 95%
and RH values 95%
Temperature accuracy and re- Good temperature accuracy (0.1°C) Very good temperature accuracy (0.1°C). The
sponse time forced ventilation across the element facili-
tate the convective exchanges reducing the
response time
Measurements in severe conditions More fragile. When corrupted, sensor Even in severe conditions the wet&dry bulb
(polluted, salty, corrosive air) needs to be fully replaced is very rugged. Simple maintenance is re-
quired when the cotton sock becomes dirty
Sensor life time In fix applications, life time is about 2- In fix applications the sensor life time is only
3 years depending by the mechanical conditions.
(stand alone applications)
Sensitive elements are very rugged
Power comsumption Low power consumption High power consumption because of pres-
ence of the forced ventilation by the fan
Application Can be used indoor and outdoor Can be used indoor. Outdoor, only in above
(using a radiant screen) freezing temperatures. In outdoor, it needs
to be closed in a Stevenson screen
2
2
RELATIVE HUMIDITY AND AIR TEMPERATURE
Thermohygrometer
Air temperature and RH% sensor with Pt100 output for temperature and 0...1 Vdc output for RH%.
It is a precise and reliable sensor, suitable for a continuous measurement even in severe environments, in presence of pol-
lutants, deep thermal and hygrometric ranges in long-term monitoring.
Technical Specifications
Resolution 0.01°C
3
Thermohygrometer (direct output)
Hysteresis <1%
Resolution 0,1%
Accessories
SVICA0003 Calibration certificate ISO9001 (Temperature)
4
4
RELATIVE HUMIDITY AND AIR TEMPERATURE
Thermohygrometer
(analogue, digital and radio outputs )
Sensor for measuring the air temperature and relative humidity in indoor environments or inside pipes.
In applications with dirty air, it is possible to mount the sensor inside the DYA225 shelter in order to prevent dirt from
accumulating directly on the sensitive element.
Technical Specifications
Radio transmission 25 ± 3 mW - -
power
Configuration - Hyperterminal -
5
Thermohygrometer
(analogue, digital and radio outputs )
Electric protections NO (electrically insulated Tranzorb and Emifilter Tranzorb and Emifilter
system)
Hysteresis <1%
Resolution 0.1%
6
6
Thermohygrometer
(analogue, digital and radio outputs )
Accessories
DWA505A Cable L= 5 m
DWA510A Cable L= 10 m
DWA525A Cable L= 25 m
DWA526A Cable L= 50 m
DYA225 Open well for T+RH% sensors when mounted in ducts in presence
of dirty air flow.
Material: Iron
Dimensions: L= 200 mm Ø 92 mm
Support plate: 120x120 mm
7