ACE9000 SSP PLC Short Codes and Error Codes - Compressed
ACE9000 SSP PLC Short Codes and Error Codes - Compressed
04+
MCU Short codes for technicians and consumers
SC Description SC Description
000 Test all 207 Display LCTA TID 4
001 Test disconnect 283 Display LCTA 4 (20 digit token)
002 Test display 208 Display LCTA amount 5
004 Display total (User Active kWh) 209 Display LCTA TID 5
005 Display KRN and KT 284 Display LCTA 5 (20 digit token)
006 Display tariff index 210 Display LCTA amount 6
007 Display maximum power limit 211 Display LCTA TID 6
009 Display credit 285 Display LCTA 6 (20 digit token)
030 Display Supply Group Code (000000 after key 212 Display LCTA amount 7
change)
050 Display instantaneous power 213 Display LCTA TID 7
070 Display Line Voltage 286 Display LCTA 7 (20 digit token)
073 Display Load Current 214 Display LCTA amount 8
076 Display Line Frequency 215 Display LCTA TID 8
077 Display Temperature inside meter 287 Display LCTA 8 (20 digit token)
079 Display Cumulative Consumption in Current 24H 216 Display LCTA amount 9
080 Display Cumulative Consumption in Previous 24H 217 Display LCTA TID 9
081 Display Cumulative Consumption in Current 30d 288 Display LCTA 9 (20 digit token)
082 Display Cumulative Consumption in Previous 30d 218 Display LCTA amount 10
084 Display ETBD using Cumulative P24H value 219 Display LCTA TID 10
086 Display ETBD using Cumulative P30d value 289 Display LCTA 10 (20 digit token)
087 Display total (Meter Active unidirectional kWh) 220 Display LCTA Amount 11
088 Display total (Export Active kWh only) 221 Display LCTA TID 11
090 Display power factor angle 290 Display LCTA 11 (20 digit token)
100 Display Meter Serial Number (MSN/DRN) 222 Display LCTA Amount 12
101 Display meter firmware version& code CRC 223 Display LCTA TID 12
200 Display LCTA amount 1 291 Display LCTA 12 (20 digit token)
201 Display LCTA TID 1 224 Display LCTA Amount 13
280 Display LCTA 1 (20 digit token) 225 Display LCTA TID 13
202 Display LCTA amount 2 292 Display LCTA 13 (20 digit token)
203 Display LCTA TID 2 226 Display LCTA Amount 14
281 Display LCTA 2 (20 digit token) 227 Display LCTA TID 14
204 Display LCTA amount 3 293 Display LCTA 14 (20 digit token)
205 Display LCTA TID 3 228 Display LCTA Amount 15
282 Display LCTA 3 (20 digit token) 229 Display LCTA TID 15
206 Display LCTA amount 4 294 Display LCTA 15 (20 digit token)
SC Description
008 Display tamper status (if enabled)
033 Display low credit threshold
035 UTM Mode Setup
103 Display VTC table ID (FOIN)
152 Date of Manufacture
154 Display VNOM
155 Display FNOM
250 Display Reason for Last Disconnection
251 Display Number of Load Switch Disconnections
252 Display Lockout Detections
253 Display Number of external disconnections
254 Display Over Power Detections
255 Display Reverse Energy Detections
256 Display Over Voltage Detections
257 Display Under Voltage Detections
258 Display Over Frequency Detections
259 Display Under Frequency Detections
260 Display Over Temperature Detections
261 Display Under Temperature Detections
262 Display Number of KCTs accepted
263 Display Number of Line Voltage interruptions
266 Display Minutes since Last Power-up
267 Display Load Present since last Power-up
268 Display Consumption since last Power-up
269 Display Accepted Credit
270 Display Number of Credit token accepted
271 Display last Token report status
272 Display total number of Operational minutes
Value Reason
0 No trip
1 Credit
2 Over-power
3 (not used)
4 Test all token
5 Test load switch token
6 External disconnect
7 Lockout
8 (not used)
9 Tamper
10 Memory failure
11 (not used)
12 Over-voltage
13 Under-voltage
14 Over-frequency
15 Under-frequency
16 Over-temperature
17 Reverse power
18 Power down
19 Unknown
20 Under-temperature
21 Live output
22 Load Switch PSU failure
0 1 2 3 4 5 6 7
0000 = 0hrs 0=6.2 00=2,000 imp/kWh 0=No
0001 = 1hr 1=3.3 01=4,000 imp/kWh 1=Yes
0010 = 2hr 10=8,000 imp/kWh
0011 =3hr 11=10,000 imp/kWh
…..
1111=15hr
Error Display Codes
OOOOO Old token Token received is older than the oldest token on the TID stack.
UUUUU Used token Token received is already present on the TID stack.
XXXXX Key expired Token received whose TID (highest byte) is greater than the KEN
value.
DDDDD Default key Credit tokens are rejected with this message when the meter has a
Default key (DDTK).
EEEEE 02 NVM failure One or more of the secure stores are invalid.
EEEEE 04 Overflow error Token cannot be accepted because it causes an overflow. This
token can be accepted at a latter point in time when an overflow will
not occur.2(^63Wh)
EEEEE 05 Key type error Key type not supported. This is displayed when an attempt is made
to change the key to DCTK.
EEEEE 07 Range error Range error (If Key Revision number or Tariff index are illegal
values in a Key Change Token)
EEEEE 13 CRC error The token's CRC does not match the calculated CRC.
EEEEE 14 Manufacturing The token is not valid because the Manufacturing Code in the token
Code error is not the Itron Manufacturing Code.
EEEEE 98 CIU Short Code CIU short code rejection (invalid CIU 4 digit short code)