Preboard Exam Practical SPDI
Preboard Exam Practical SPDI
Preboard Exam Practical SPDI
[email protected] Switch accounts
*Required
February 2023 Pre Board : Sanitation Plumbing Design and Intallation (100Items)
The spout of a lavatory faucet with P.O. assembly is also the housing for:*
1 point
Handicap sink installation require that metallic pipe that could become hot from water flow be:*
1 point
A lavatory with pop-up drain assembly connects to the drain using a:*
1 point
A kitchen sink faucet that has a base plate and a separate spray requires a:*
1 point
a. Two-hole sink
b. Three-hole sink
c. Four-hole sink
d. None of the above
The rims of bowls used for handicap toilets and non-handicap toilets:*
1 point
a. 1⁄2”
b. 3⁄4”
c. 1”
d. 1 1⁄4”
Most codes dictate that a fixture cannot be supplied with more than:*
1 point
Copper piping used for medical gas systems should only be cut with a:*
1 point
a. Hack saw
b. Band saw
c. Reciprocating saw
d. Copper tubing butter
A short length of pipe with threads at each end; used to join couplings or fittings*
1 point
a. Dead End
b. Nipple
c. Fixture Branch
d. Thimble
a. 1”
b. 1 ½”
c. 1 ¼”
d. ½”
A pipe connecting upward from a soil and waste stack to a vent stack for the purpose of
preventing pressure changes in the stack.*
1 point
a. Yoke vent
b. Wet vent
c. Dry vent
d. Local vent
a. ½”
b. 1 ¼”
c. ¼”
d. 1”
A trench containing course aggregate and a distribution tile pipe through which septic tank
effluent may flow covered with earth.
*
1 point
a. Absorption trench
b. Illumination
c. Air trap
d. Catch basin
The water supply to a water closet utilizing a flush valve (flushometer) is:*
1 point
a. ½”
b. ¾”
c. 1”
d. 1 ¼”
The maximum concentration (amount) of a chemical worker can be exposed to is known as:*
1 point
a. Everyone
b. The employer
c. The employee
d. OSHA
a. 3 feet
b. 2 feet
c. 1 feet
d. 4 feet
Codes dictate the _______ be installed in the cold water piping near a water heater.*
1 point
a. An isolation valve
b. A circulating pump
c. A pressure booster
d. All of the above
a. Stable rock A, B, C
b. Stable rock 1, 2, 3
c. Both A & B
d. None of the above
a. 1 ½”
b. 1 ¼”
c. 1’’
d. ½”
a. ½” bend
b. 1 ¼” bend
c. 1 ½” bend
d. ¼” bend
a. Fixture branch
b. Soil pipe
c. Developed length
d. Invert
a. 2”
b. 2 ½”
c. 4”
d. 3”
Moderately noisy. Similar to siphon jet except that trap passageway and water surface area are
smaller.*
1 point
a. Wash down
b. Reverse trap
c. Bidet
d. Blow out
a. Wheels
b. Casters
c. Rollers
d. Tires
a. A cistern is used
b. The roof gutters are piped to a well
c. A special plumbing permit is required
d. None of the above
Urinal is abbreviated as:*
1 point
a. U
b. UR
c. URN
d. URNL
a. One-sixteenth of a circle
b. One-eighth of a circle
c. One-fourth of a circle
d. One-half of a circle
A ball valve:*
1 point
Using 1/8” scale to interpret a blueprint dimension means that 1/8” equals:*
1 point
a. One foot
b. One yard
c. One inch
d. One eight
a. Waste system
b. Waste stack
c. Water system
d. Water stack
A water service pipe must be installed per local codes, but always:*
1 point
a. 30 deg angles
b. 60 deg angles
c. 90 deg angles
d. All of the above
A full circle connected to a line illustrated is a plan view of a piping system indicates that is a:*
1 point
a. Pipe stubbing out
b. Pipe turning down
c. Pipe turning up
d. None of the above
a. Sink venting
b. Supply vertical
c. Supply vented
d. Stack vent
a. Lavatory
b. Sink
c. Toilet
d. Tub
. A pipe installed to vent, a fixture trap and which connects with the vent system above the
fixture served or terminates in the open air.*
1 point
a. Individual vent
b. Stack vent
c. Loop and circuit vent
d. Relief vent
a. 1 ¼”
b. 1”
c. 2 ¼”
d. 2”
a. 2”
b. 3”
c. 1”
d. 4”
Minimum cost. Least efficient subject to clogging, noisy. Simple washout and emptying through
small irregular passage way, prohibited by some health codes.*
1 point
a. Wash down
b. Reverse trap
c. Blow out
d. Bidet
a. 1”
b. 2”
c. 2 ¼”
d. 1 ½”
a. Wood screws
b. Hex nuts and possibly washers
c. Anchor bolts
d. A threaded thimble
A split hanger:*
1 point
Water supply rough-in for a flush valve (flushometer) that serves a toilet is:*
1 point
a. Shower faucets
b. Tub faucets
c. Sink faucets
d. None of the above
Includes water supply and distribution pipe; plumbing fixture and traps, soil, waste and vent
pipes; house drain and house sewers including their respective connections.*
1 point
a. Water reservoir
b. Siamese connections
c. Plumbing system
d. Trap seal
a. 4”
b. 6”
c. 2”
d. 3”
Ratio of water closets for female population for elementary and secondary school.*
1 point
a. Ratio of 1:45
b. Ratio of 1:25
c. Ratio of 1:55
d. Ratio of 1:30
A valve which in the water flow is shut off by a flat disk that is screwed down onto its seat. *
1 point
a. Compression valve
b. Overhead storm drain
c. Pressure reducing valve
d. Union patente
a. Illumination
b. Flood level
c. Plumbing system
d. Fixture branch
One btu increases the water temperature of _______ by one degree Fahrenheit.*
1 point
a. One gallon
b. One pound
c. One quart
d. One ounce
a. Dishwasher
b. Drain wall
c. Discharge waste
d. Drainage waste
Water boils at sea level under normal atmospheric pressure at a temperature of:*
1 point
Urinals and commercial toilets that do not use a tank receive water supply from:*
1 point
a. An angle stop
b. A straight stop
c. A dual stop
d. A flush valve (flushometer)
The vertical distance from a faucet spout outlet to the flood-level rim of a fixture is called:*
1 point
a. Flow space
b. Aerator distance
c. Backflow gap
d. Air gap
a. 1”
b. 1 ½”
c. ¼”
d. ½”
a. Black
b. White
c. Blue
d. Green
A passage under a road, embankment or canal which allow for the flow of water.*
1 point
a. Cistern
b. Culvert
c. Catch basin
d. Air trap
Is the backflow of used, contaminated or polluted water from a plumbing fixture due to negative
pressure.*
1 point
a. Backflow
b. Back siphonage
c. Yoke vent
d. Friction loss
Is the lowest portion of the inside of any pipe or conduit that is not vertical.*
1 point
a. Invert
b. Fixture branch
c. Soil pipe
d. Rough-in
a. 2”
b. 1 ½”
c. 1 ¼”
d. None of the above
A slip joint style p-trap connects to the drainage system using a: *
1 point
a. Coupling
b. Trap adapter
c. Male and female adapter
d. None of the above
A dip tube:*
1 point
Heat exchanger transfer heat from a hot object, vapor, or fluid to:*
1 point
a. Water
b. Convert the heat electricity
c. Heat an occupied space only
d. None of the above
A coupling*
1 point
a. 1,000 watts
b. 3,412 btus
c. Both a&b
d. None of the above
The trade name for a combination wye and eight bend is:*
1 point
a. Sanitary tee
b. Sanitary cross
c. 45 deg wye
d. Combo
a. Cistern
b. Corporation stop
c. Absorption trench
d. Catch basin
a. Catch basin
b. Corporation stop
c. Cistern
d. Absorption trench
Ratio of water closets for female population for principal worship places.*
1 point
a. Ratio of 1:75
b. Ratio of 1:60
c. Ratio of 1:85
d. Ratio of 1:70
Noisy but highly efficient. Strong jet into leg forces contents out. Higher pressure required.
*
1 point
a. Bidet
b. Reverse trap
c. Siphon-jet
d. Blow out