Ar3151-Fnoutputs Bernardino
Ar3151-Fnoutputs Bernardino
Ar3151-Fnoutputs Bernardino
3
4 " Ø G.I WATER RISER
12.00
4.00 4.00 4.00 3
4 " Ø G.I WATER RISER PIPE TO WATER TANK
2.50 1.00
1 " Ø G.I WATER BRANCH PIPE
2
GV
1.00
R
2.00
O.T
R
1.00
R CV
R GV
3
Hb
2.00
5.00
5.00
2.00
SV
12.00
AV
10.00
2.00
2
AC
1.00
2.00
2.50
5.00
Hb
2.00
1.50
AV SV
1
AC
Hb
CV
M
GV GV
1
" Ø G.I WATER BRANCH PIPE
2
from water main
DEEP WELL 3
4" Ø G.I WATER MAIN SUPPLY
PIPE TO WATER TANK
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
4.00 4.00 4.00
2.50 1.50
1.00
3
4"Ø G.I WATER RISER
2.00
1.00
R
3
SV
2.00
2.00
AV
AC
5.00
2.00
3.00
12.00
10.00
2.00
2
1.00
1
2" Ø G.I WATER BRANCH PIPE
2.00
5.00
4.00
2.00
1
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
RL CB S S S S S S S S S S S S S
1.00
6" Ø pvc STORM PIPE
S
2.00
S
CB RL
1.00
3
S
2.00
SS
5.00
5.00
S
2.00
12.00
S
10.00
2.00
2
RL CB
1.00
SS
2.00
2.50
S
CB RL
5.00
S
S
2.00
S
S
1.50
1
S
S
RL CB
S
S
S
TO PUBLIC TO PUBLIC
STORM DRAIN STORM DRAIN
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
4"Ø pvc SOIL BRANCH PIPE 4"Ø pvc SOIL STACK PIPE
WITH 2"Ø pvc BENT PIPE WITH 2"Ø pvc BENT PIPE
1.00
2.00
SEPTIC VAULT
1.00
3
2.00
5.00
5.00
2.00
12.00
wc
10.00
2.00
2
C.O
1.00
2.00
2.50
5.00
2.00
1.50
wc
1
C.O
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
4"Ø pvc SOIL STACK PIPE
WITH 2"Ø pvc BENT PIPE
1.00
2.00
1.00
MSWV
3
2.00
2.00
wc
C.O
5.00
2.00
3.00
12.00
10.00
2.00
2
1.00
2.00
5.00
4.00
2.00
1
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
1.00
DS
2.00
RL
1.00
3
2.00
2.00
SURFACE
RUN-OFF
5.00
2.00
3.00
12.00
RL
10.00
2.00
2
DS
1.00
2.00
5.00
RL
4.00
SURFACE
RUN-OFF
2.00
1
RL
DS
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
1.00
CEESPOOL
2.00
MSWV
1.00
3
2.00
Fdn
5.00
5.00
2.00
Sdn
12.00
lav
10.00
2.00
2
C.O
1.00
2.00
2.50
5.00
lav
2.00
1.50
Fdn
Sdn
1
C.O
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
1.00
2.00
1.00
MSWV
3
2.00
Sdn
2.00
Fdn
lav.
C.O
5.00
2.00
3.00
12.00
10.00
2.00
2
1.00
2.00
5.00
2.00
1
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
12.00
DS
2.00
1.00
3
SURFACE
RUN-OFF
2.00
5.00
8.15
6.15
2.00
SURFACE
RUN-OFF
10.00
2.00
2
1.00
2.00
1.00 5.20
5.00
DS
6.20
2.00
1
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
SURFACE
STORM DRAIN
RUN-OFF
C.O DS
TO PUBLIC
AND REGULATION OF THE UTILITY COMPANIES a DS
CONCERNED. G G P P
ST
C.O to S S
ALL MATERIALS TO BE USED SHALL BE NEW wye - 1/8 bend - p trap connection ks RL CB
wc Septic Tank
APPROVED TYPE APPROPRIATE FOR BOTH to catch basin
4" Ø PVC SOIL STACK PIPE 3"Ø PVC STORM PIPE RL 4" Ø IPVC GROUND STORM PIPE
LOCATION AND INTENDED USE. 3"Ø PVC BRANCH & WASTE WATER STACK PIPE
* TYPICAL TO ALL FIXTURES EXCEPT WC ( min. recommended size ) ( min. recommended size ) ( min. recommended size )
Stack p. as seen
PLUMBING INSTALLATION SHALL BE UNDER MSWV MAIN SOIL AND
DIRECT SUPERVISION OF A DULY REGISTERED on top STACK PIPE C.O. WASTE VENT PIPE SURFACE RUNOFF SURFACE RUNOFF
MASTER PLUMBER. below STACK PIPE CLEAN OUT G GUTTER LINE DS DOWNSPOUT
Btdn BATH TUB DRAIN WC WATER CLOSET DS DOWNSPOUT RL ROOF LEADER
NO REVISION IN THE DESIGN SHALL BE DONE
WITHOUT THE PRIOR KNOWLEDGE OF THE Lt LAUNDRY DRAIN KS KITCHEN SINK RL ROOF LEADER CB CATCH BASIN
DESIGNER AND THE OWNER, ANY SUCH a 2" x 3" REDUCER P PERFORATED PIPE
REVISION DONE WITHOUT THE CONSENT
OF THE DESIGNER, HIS RESPONSIBILITY SHALL S STORM PIPE
CEASE AS A WHOLE. WATER : WATER : SEWER : PLUMBING
The plumbing lines indicated in this layout suggest its * use 1/2" insulated pipe ( min. recommended size ) ( min. recommended size )
general location and direction, it must be followed on site. * To all Fixtures and pipe ends
M MSWV MAIN SOIL AND
However, if site condition does not permit, rerouting may be AIR CHAMBER WATER METER
AC M C.O. WASTE VENT PIPE BTDN BATH TUB DRAIN
made. the new layout must be drawn and made available in the
as-built plan for future trouble shooting. GV GATE VALVE GV GATE VALVE CLEAN OUT SL SLOP SINK
The plumbing lines indicated in this layout with hidden R RISER PIPE R RISER PIPE FDN FLOOR DRAIN LT LAUNDRY TUB
lines does not suggest actual location & direction, only SV SHOWER VALVE CV CHECK VALVE LAV LAVATORY SDN SHOWER DRAIN
connectivity.
AV ANGLE VALVE Hb HOSE BIBB a 2" x 3" REDUCER S STORM PIPE
Nipple Provision for tapping faucets
Couling or valves OT OVERHEAD TANK
PLUMBING NOTES P PLUMBING LEGENDS / SYMBOLS
SCALE
1010 NOT TO SCALE
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
FLOOR LINE
150
ANCHOR BOLT
SECT. A-A'
U - BOLT
CLEANOUT COVER
THREADED BOLT WITH NUT
AND LOCKWASHER
160 240
WALL
W + 300
PIPE HANGER DETAIL-1
BEND
REDUCER
BRANCH PIPE
CLEANOUT DETAIL
150
11A SCALE AS SHOWN
11B SCALE AS SHOWN
PIPE HANGER
CAP
CAULK SEAL SECTION SHOWING MASONRY WALL 2 CHAMBER CESPOOL
CAULKING
10mm Ø HANDLE
100
AIR CHAMBER
PLAN
VENT PIPE
REDUCER
FLOOR LINE
300
AIR SPACE
SURFACE LEVEL OF DIGESTION CHAMBER
SURFACE LEVEL OF
CEESPOOL
D + 507
100mm X 100mmØ SANITARY TEE SOIL PIPE INLET
TO FIXTURES 100mm Ø SOIL PIPE OUTLET
TEE
D
TEE
AIR CHAMBER
11C SCALE
11D AS SHOWN SCALE AS SHOWN
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
3'' Ø WYE
3'' Ø WYE
3'' Ø 81 BEND
3'' Ø ELBOW
3
4 " Ø B.I. PIPE HANDLE
PIPE SLEEVE
3
16 '' X 1'' ANGLE BAR PIPE HANGER
200
3''Ø P-TRAP
3'' Ø WYE
1
2'' Ø ELBOW
100
1
2'' Ø TEE
SWAY BRACE
E
PIP
ER
400 AT
TEW
WAS 1
AY 2'' Ø COLD WATER SUPPLY PIPE
GR
H
A NC
BR
C
PV
Ø
3''
1
2'' Ø ELBOW
4'' CHB
1
2 '' Ø TEE
1
2 '' Ø TEE 1/2 '' Ø TEE
SOIL PIPE & STORM LAYOUT
1
2'' Ø COLD WATER SUPPLY PIPE 1
2'' ELBOW 1
2'' ELBOW
1
2'' Ø TEE
1412 1512
SCALE AS SHOWN SCALE NTS
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED
LAVATORY
SUPPLY PIPE
SHOWER HEAD
CURTAIN ROD
MIXING VALVE
SOAP HOLDER
FOOT FAUCET
SHOWER
P MOUNTING HEIGHTS
SCALE AS SHOWN
1713
SUBJECT STUDENT PLATE TITLE
AR 3151/D BUILDING TECH 3 7:30 - 8:30 MW / 8:30 - 11:30 M BERNARDINO, ALFRED VINCE A. "PLUMBING SYSTEM"
INSTRUCTOR COURSE AND YEAR DATE GIVEN DATE DUE DATE SUBMITTED