0% found this document useful (0 votes)
112 views4 pages

Sky 301vs

The document provides troubleshooting steps for various elevator control issues, including: 1) Checking safety voltage parameters and connections 2) Verifying KG and T2 signal voltages 3) Inspecting SL1, SL2 input cables and shaft communication type settings 4) Checking for missed phase voltages 5) Replacing mismatched wires 6) Addressing overload signals by contacting maintenance 7) Reviewing error logs, clearing errors, and restarting the control card
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views4 pages

Sky 301vs

The document provides troubleshooting steps for various elevator control issues, including: 1) Checking safety voltage parameters and connections 2) Verifying KG and T2 signal voltages 3) Inspecting SL1, SL2 input cables and shaft communication type settings 4) Checking for missed phase voltages 5) Replacing mismatched wires 6) Addressing overload signals by contacting maintenance 7) Reviewing error logs, clearing errors, and restarting the control card
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MAIN CONTROL BOARD

Troubleshooting
V - 5.01
1

Troubleshooting:
1- Please check to the 14. SAFETY VOLT parameter if correct.
2- Please check to the safety voltage between 120 and 11A lines.

---------------------------------------------------------------------------------------------------------------------------------------------
2

Troubleshooting:
1- Please check to the KG signal connection .
2- You should seed 24V in KG signal when all conductors are fine.
---------------------------------------------------------------------------------------------------------------------------------------------
3

Troubleshooting:
1- Please check to the T2 signal connection .
2- If signal already have 24V in the T2 input you should change the input from the 32.AUX INPUT
parameter .
---------------------------------------------------------------------------------------------------------------------------------------------

Troubleshooting:
1- SL1 and SL2 inputs cables .
2- The 5.SHAFT COM. TYPE parameter must be seted to PAR. DATA in Parallel lift systems.
---------------------------------------------------------------------------------------------------------------------------------------------

Troubleshooting:
1- R PHASE MISS / S PHASE MISS / T PHASE MISS , Please check to the missed phase voltage.
---------------------------------------------------------------------------------------------------------------------------------------------
6

Troubleshooting:
1- Please replace the R and S wires .
---------------------------------------------------------------------------------------------------------------------------------------------
7

Troubleshooting:
1- The elevator is overloaded , Overload signal is 804 .
---------------------------------------------------------------------------------------------------------------------------------------------
8

Troubleshooting:
1- The elevator must be maintained.
2- Talk to the maintenance company. If you do not receive an answer, please contact us via email or
phone Our E-mail is: [email protected] Tel: +359 89 588 41 58.
---------------------------------------------------------------------------------------------------------------------------------------------
9

Troubleshooting:
1- Goto To The 38.ERROR LOG Parameter .
2- Press ENT.
3- Press ESC to exit from the ERROR LOG parameter.
4- You should see ERROR CLEAR on display then press ENT
5- Restart the card.
6- Talk to the maintenance company. If you do not receive an answer, please contact us via email or
phone Our E-mail is: [email protected] Tel: +359 89 588 41 58.
---------------------------------------------------------------------------------------------------------------------------------------------
10

Troubleshooting:
1- Please check to the 120 and 130 safety input voltage.