Troubleshooting & Diagrams
SmartPhone VI
Re l a y A l a r m
Communications Communications
Failure is * Failure is
required, connect required, connect
Re l a y A l a r m
to our to our
Alarm Relay *
* Alarm Relay *
RJ11
Enter
Record
RJ11
LED Sw it c h
Play/Pause
Enter
Stop
Record
+-
To Phone Line: Bat MIC Speaker To Phone Line:
Requires a twisted Requires a twisted
LED
Play/Pause
RJ11
RP7300144-24/5VA
120vac
Black
To 24vac/dc Power Supply Hot Green
RJ11
Ground
White
Neutral
Annunciator Interface,
Auxiliary Relay & 24v LED Board 1. Connect your annunciator’s audio output to the TB1 connection
on this board.
24v LED 24vdc Power for LED
2. When utilizing this board to drive a 24v LED, you must apply
power to the wire leads at the TB2 connection. You may tap into
TB2
-+ Relay 1
a direct 24vdc supply that has battery backup. Connect the wire
-+ leads at the J5 connection to your LED.
To LED on SPVI
Relay 2 3. If you are not utilizing this board to drive a 24v LED, you need
to disconnect the LED harness from the SmartPhone board,
disconnect the LED harness from this board, connect it to the
-+
Initial Set-Up:
1. Diagnostic Test: Press Enter, 2, 6, Play/Pause phone will play back (5) Beeps (1st Beep=External Power Supply; 2nd
Beep=LED; 3rd Beep=Microphone; 4th Beep=Speaker; 5th Beep=Backup Battery). If any item fails during test you will hear
a Blat not a Beep. If you hear a Blat, contact RATH® Technical Support.
Note: If you receive a Blat for the LED, check the LED operation to be sure it is not working before contacting RATH® Technical Support.
2. Connect to standard RJ11 phone jack. If splicing connection, only hook up Red and Green Wires from the phone cable. If
connecting to a SmartRescue unit, you must connect all four wires (check for 24vdc or 48vdc supply at the splice).
Troubleshooting:
1. If the phone dials only one digit and hangs up, there is another Auto-Dialer on the line. You need to re-wire the system so
that the RATH® unit is either in parallel or ahead of it.
2. If the phone dials a couple of digits and gets a busy signal, the unit is installed on a switchboard line and needs to be
programmed to dial the appropriate access code to get an outside line (usually an 8 or 9).
3. If the phone does not respond, make sure the green LED (D1) on the circuit board is lit. If not, check to be sure the power is
properly connected.
4. If the phone is making phantom calls, it is installed on a Ring Down Line. You must turn off the “Telephone Line Check”
feature (see Optional Programming Instructions).
Re l a y A l a r m
* *
RJ11
RJ11
Enter Enter
To Phone Line: To Phone Line:
Record
Requires a twisted Requires a twisted
Record
shielded pair. shielded pair.
When used with When used with
LED
Play/Pause
LE D S w i t ch
Play/Pause
SmartRescue, SmartRescue,
S wi t ch
12v
RJ11
RJ11
To 12vac/dc White/Neutral
Power Supply Transformer To 120vac
Note: If Elevator Communications Failure is Black/Hot