Cortinas de Luz - SF4B Linha C
Cortinas de Luz - SF4B Linha C
Cortinas de Luz - SF4B Linha C
SF4B-C SERIES
FIBER
■■General terms and conditions.............. F-3 ■■Selection guide.............................. P.457~
SENSORS Related Information ■■SF-C13.......................................... P.663~ ■■Glossary of terms........................ P.1549~
LASER
SENSORS
■■General precautions...................... P.1595 ■■Korea’s S-mark.............................. P.1602
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC Certified
SENSORS
AREA
SENSORS Conforming to
SAFETY LIGHT Certified by OSHA / ANSI
CURTAINS / NRTL
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
Certified
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC Category 4 PLe SIL3 panasonic.net/id/pidsx/global
CONTROL
DEVICES
The control category differs depending on the configuration and wiring of the external circuit.
LASER
MARKERS
PLC
Compact, light weight design, and advanced functionality in one package
HUMAN MACHINE
INTERFACES Compact profile design, maximize the machinery opening area
ENERGY
MANAGEMENT
SOLUTIONS
The SF4B-C series is designed to fit onto an aluminum frame, maximizing the machinery opening area.
It can even allow zero dead zone.
FA COMPONENTS
MACHINE VISION
SYSTEMS Side mounting
UV CURING Width
■ The presence of safety light curtain does not
19.6
SYSTEMS
Just mm Depth
narrow the opening area.
0.772 in 27.4 mm
■ The safety light curtain is thin, so its bulge
from frame can be minimized.
Selection
Guide
Safety Light
1.079 in
hen using standard mounting brackets MS-SF4BC-1
*W
(optional)
Curtains
Safety
Control Units
Safety
Components
SF4D
SF4B/
SF4B-G
SF4B-C
SF4C
Embedded mounting (side) Rear mounting
BSF4-AH80
SF2B ■ The safety light curtain ■ The safety light curtain
SF2C fits onto frame perfectly, fits onto a 20 × 20 mm
Definition of
even in embedded 0.787 × 0.787 in
Sensing Heights installations. aluminum frame
■ The safety light curtain perfectly.
protrudes neither into ■ The safety light curtain
the machinery opening does not protrude
nor outside the frame. from the frame.
■ The safety light curtain will
not be damaged due to
collision with workpiece.
* When using standard mounting * When using standard mounting
brackets MS-SF4BC-1 (optional) brackets MS-SF4BC-1 (optional)
SF4B-C SERIES
Compact Safety Light Curtain Type 4
546
height SENSOR
* This is an only image
for seamless enclosure Max. OPTIONS
partially cut. 1,943.4 mm SIMPLE
76.512 in WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
Protective CONTROL
height DEVICES
Min.
263.4 mm LASER
MARKERS
10.370 in
PLC
HUMAN MACHINE
45% lighter* for easy installation in high places and when mounting long models INTERFACES
ENERGY
MANAGEMENT
Thanks to its plastic body, the SF4B-C series is 45 % SOLUTIONS
lighter* than previous models with aluminum enclosures.
FA COMPONENTS
This helps to reduce the overall weight of the equipment
during transport and when shipping it overseas.
MACHINE VISION
* Comparing SF4B-H80<V2> with SF4B-H80CA-J05 SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Safety Light
Curtains
Safety
Control Units
Large multi-purpose indicator SF4B-□CA-J05 Safety
Components
The SF4B-C series is equipped with the large multi-purpose indicator at the center of the unit. The indicator shows
SF4D
the presence of the safety light curtain, helping to prevent unintentional beam interruption. The indicator can be used
in a variety of applications such as a muting indicator and work indicator. SF4B/
SF4B-G
SF4B-C
SF4C
BSF4-AH80
SF2B
Exceptional visibility with
SF2C
wide angle
Definition of
The large multi-purpose indicator Sensing Heights
shines brightly through the plastic
body to ensure exceptional visibility.
SF4B-C SERIES
547 Compact Safety Light Curtain Type 4
FIBER Handy-controller SFB-HC (optional) offers easy access to settings for a range of functionality
SENSORS
LASER Muting control function for individual beams: Fixed blanking function:
SENSORS
Limit the muting area SF4B-□CA-J05 Choose active beam channels
PHOTOELECTRIC
SENSORS The SFB-HC handy-controller (optional) allows to The SFB-HC handy-controller (optional) provides a fixed
MICRO perform muting control for certain beams. Since beam blanking function that prevents control output (OSSD)
PHOTOELECTRIC channels can be specified, so there is no need to install from turning off even if certain beam channels are
SENSORS
a guard to prevent intrusions. For example, according to interrupted. This function is convenient for applications
AREA the height of a sensing object, when muting control from where an obstacle always interrupts certain beam
SENSORS
the lowermost beam channel to the 10th beam channel channels.
SAFETY LIGHT
CURTAINS / is activated, the safety light curtain will detect any beam Additionally, it is safe since control output (OSSD) is
SAFETY COMPONENTS interruption at the 11th or higher beam channel as a forcibly turned off in the event the obstruction moves
PRESSURE /
FLOW human entry and stop the machinery. outside the detection area.
SENSORS
INDUCTIVE During muting (line operating) Line stopped
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS Floating blanking function: Use output and indicators to achieve preventive main-
Disable unspecified beams tenance when the incident light intensity gets unstable
PLC
The floating blanking function allows to disable up By setting the auxiliary output switching function to
HUMAN MACHINE to three unspecified beam channels. Control output off or on when light reception becomes unstable, the
INTERFACES
(OSSD) will not turn off as long as the number of safety light curtain provides notification in the event of
ENERGY
MANAGEMENT
interrupted beam channels is less than the set number a reduction in the incident light intensity due to beam
SOLUTIONS of beam channels. This function is convenient when an misalignment or dirt via auxiliary output (non-safety
obstruction moves inside the detection area during setup output) in addition to the incident light intensity indicator.
FA COMPONENTS
changes or when loading materials within the detection
Auxiliary output
MACHINE VISION
area of safety light curtain.
Incident light intensity indicator Set to off for Set to on for
SYSTEMS * The min. sensing object will change when the floating blanking function unstable incident unstable incident
is used. light (Note 3) light (Note 3)
UV CURING Under stable light received
SYSTEMS condition: Green ON OFF
intensity (Note 1)
LASER
Pigtailed type (with muting function) Cable type SENSORS
(with 0.5 m 1.640 ft connector attached cable) (with 5 m 16.404 ft cable)
PHOTO-
ELECTRIC
SENSORS
3 3
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
1 2 SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
5 4 PROXIMITY
SENSORS
PARTICULAR
Cable 5 m 16.404 ft (discrete wire) USE
Connector attached cable 0.5 m 1.640 ft SENSORS
SENSOR
ORDER GUIDE OPTIONS
SIMPLE
WIRE-SAVING
1 2 Safety light curtains UNITS
Control Units
21.7 mm
Beam 0.854 in SF4B-A20CA-J05 SF4B-A20C 20 823.4 mm 32.417 in Safety
channel No. Beam pitch Components
Protective 40 mm SF4B-A24CA-J05 SF4B-A24C 24 983.4 mm 38.717 in
height 1.575 in
SF4B-A28CA-J05 SF4B-A28C 28 1,143.4 mm 45.016 in
SF4D
0.3 to 7 m
SF4B-A32CA-J05 SF4B-A32C 32 1,303.4 mm 51.315 in SF4B/
0.984 to 22.966 ft SF4B-G
SF4B-A36CA-J05 SF4B-A36C 36 1,463.4 mm 57.614 in
SF4B-C
SF4B-A40CA-J05 SF4B-A40C 40 1,623.4 mm 63.913 in
SF4C
41.7 mm 1.642 in
SF4B-A44CA-J05 SF4B-A44C 44 1,783.4 mm 70.212 in
BSF4-AH80
SF4B-A48CA-J05 SF4B-A48C 48 1,943.4 mm 76.512 in
SF2B
Notes: 1) The operating range is the distance possible to set between the emitter and the receiver.
SF2C
Actual operating range of Definition of
Receiver cannot be the safety light curtain 7 m 22.966 ft Sensing Heights
placed in this range 0.3 m 0.984 ft
Setting range of
the receiver
FIBER
SENSORS
ORDER GUIDE
LASER 3 Mounting brackets Mounting bracket is not supplied with the safety light curtain. Be sure to order it separately.
SENSORS
PHOTO-
ELECTRIC
SENSORS Designation Appearance Model No. Description
MICRO
PHOTO-
ELECTRIC Allows the safety light curtain to be mounted on the rear or side
SENSORS
Standard mounting of the target equipment. Designed for use with one M5 hexagon-
AREA bracket
MS-SF4BC-1 socket head bolt.
SENSORS
(4 pcs. per set for the emitter and receiver)
SAFETY LIGHT
CURTAINS /
SAFETY Allows the safety light curtain to be mounted on the rear of the
COMPONENTS
target equipment. Allows beam adjustment. Designed for use
PRESSURE / Rear utility mounting
FLOW
bracket
MS-SF4BC-2 with one M5 hexagon-socket head bolt. For space-saving
SENSORS mounting, use one M5 hexagon head bolt.
INDUCTIVE (4 pcs. per set for the emitter and receiver)
PROXIMITY
SENSORS
PARTICULAR
Allows the safety light curtain to be mounted on the side of the
USE target equipment. Allows beam adjustment. Designed for use
SENSORS Side utility mounting
bracket
MS-SF4BC-3 with one M5 hexagon-socket head bolt. For space-saving
SENSOR mounting, use one M5 hexagon head bolt.
OPTIONS (4 pcs. per set for the emitter and receiver)
SIMPLE Supports the middle of the safety light curtain when installing it
WIRE-SAVING
UNITS Intermediate supporting with utility mounting brackets. Allows the safety light curtain to be
bracket for utility mounted on the rear or side of the target equipment. Allows
WIRE-SAVING mounting bracket
MS-SF4BC-4 beam adjustment. Designed for use with one M5 hexagon head
SYSTEMS
(Note) bolt.
MEASURE- (2 pcs. each per set for rear mounting and side mounting)
MENT
SENSORS
STATIC
CONTROL Supports the middle of the safety light curtain when installing it
DEVICES Intermediate supporting
with standard mounting brackets. Allows the safety light curtain
bracket for standard
LASER mounting bracket
MS-SF4BC-5 to be mounted on the rear or side of the target equipment.
MARKERS Designed for use with two M3 countersunk screws.
(Note)
(2 pcs. each per set for rear mounting and side mounting)
PLC
HUMAN
MACHINE
INTERFACES
Allows beam axis alignment and the safety light curtain to be
ENERGY mounted on the device in confined spaces. Designed for use
MANAGEMENT
SOLUTIONS
Side mounting bracket MS-SF4BC-6 with one M5 hexagon-socket head bolt.
(4 pcs. per set for the emitter and receiver)
FA
COMPONENTS
MACHINE Supports the middle of the safety light curtain when installing it
VISION
SYSTEMS Intermediate supporting with side mounting brackets. Allows beam axis alignment and
bracket for use with side the safety light curtain to be mounted on the device in confined
UV
CURING mounting bracket
MS-SF4BC-7 spaces. Designed for use with one M5 hexagon-socket head
SYSTEMS (Note) bolt.
(2 pcs. per set)
Note: The numbers of sets required by SF4B-H□C(A-J05)(40 or more beam axes) and SF4B-A□C(A-J05) (20 or more beam axes) are as follows:
SF4B-H40C(A-J05), SF4B-H48C(A-J05), SF4B-H56C(A-J05), SF4B-A20C(A-J05), SF4B-A24C(A-J05), SF4B-A28C(A-J05): 1 set
SF4B-H64C(A-J05), SF4B-H72C(A-J05), SF4B-H80C(A-J05), SF4B-H88C(A-J05), SF4B-H96C(A-J05), SF4B-A32C(A-J05), SF4B-A36C(A-J05),
Selection SF4B-A40C(A-J05), SF4B-A44C(A-J05), SF4B-A48C(A-J05): 2 sets
Guide
Safety Light
Curtains
Safety
Control Units
Safety
Components
SF4D
SF4B/
SF4B-G
SF4B-C
SF4C
BSF4-AH80
SF2B
SF2C
Definition of
Sensing Heights
SF4B-C SERIES
Compact Safety Light Curtain Type 4
550
LASER
Standard mounting bracket and Rear utility mounting bracket and Side utility mounting bracket and SENSORS
intermediate supporting bracket for intermediate supporting bracket for intermediate supporting bracket for PHOTO-
standard mounting bracket utility mounting bracket utility mounting bracket ELECTRIC
SENSORS
MICRO
PHOTO-
In case of side In case of side Space-saving Standard Space-saving Standard ELECTRIC
SENSORS
mounting mounting mounting (Note) mounting mounting (Note) mounting
AREA
SENSORS
Standard Side utility
mounting Rear utility mounting
mounting SAFETY LIGHT
bracket bracket CURTAINS /
MS-SF4BC-1 bracket MS-SF4BC-3 SAFETY
MS-SF4BC-2 COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
Intermediate Intermediate PROXIMITY
Intermediate supporting SENSORS
supporting bracket supporting
bracket for bracket for
for standard utility mounting PARTICULAR
mounting bracket utility USE
mounting bracket SENSORS
MS-SF4BC-5 bracket MS-SF4BC-4
MS-SF4BC-4 SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
STATIC
• MS-SF4BC-1 • MS-SF4BC-2 • MS-SF4BC-3 CONTROL
DEVICES
Four brackets (two each R and L type) per set Four brackets (two each R and L type) per set Four brackets (two each R and L type) per set
Eight M3 (length: 5 mm 0.197 in) hexagon-socket Eight M3 (length: 6 mm 0.236 in) hexagon-socket Eight M3 (length: 6 mm 0.236 in) hexagon-socket
LASER
head bolts and four M5 flat washers are attached. head bolts and four M5 flat washers are attached. head bolts and four M5 flat washers are attached. MARKERS
• MS-SF4BC-5 • MS-SF4BC-4 • MS-SF4BC-4
Two pcs. for rear mounting, two pcs. for side mounting Two brackets per set Two brackets per set
PLC
M5 flat washers, two pcs. assembled M3 (length: 6 mm M5 flat washers, two pcs. assembled M3 (length: 6 mm
0.236 in) hexagon-socket head bolts for rear mounting, 0.236 in) hexagon-socket head bolts for rear mounting,
two pcs. attachments for side mounting two pcs. attachments for side mounting HUMAN
MACHINE
INTERFACES
Note: For space-saving mounting, use an M5 Note: For space-saving mounting, use an M5
hexagon head bolt. hexagon head bolt. ENERGY
MANAGEMENT
SOLUTIONS
FA
Side mounting bracket and COMPONENTS
intermediate supporting bracket for MACHINE
use with side mounting bracket VISION
SYSTEMS
UV
Space-saving Standard CURING
SYSTEMS
mounting mounting
Side
mounting
bracket
MS-SF4BC-6
Selection
Guide
Safety Light
Curtains
Safety
Intermediate Control Units
supporting Safety
bracket for Components
use with side
mounting
bracket
MS-SF4BC-7 SF4D
SF4B/
SF4B-G
SF4B-C
SF4C
BSF4-AH80
Side
mounting SF2B
bracket
MS-SF4BC-6 SF2C
Definition of
• MS-SF4BC-6 Sensing Heights
Four brackets (two each R and L type) per set
Eight M3 (length: 6 mm 0.236 in) hexagon-socket
head bolts and four M5 flat washers are attached.
• MS-SF4BC-7
Two brackets per set
Two pcs. M5 flat washers, two pcs. assembled
M3 (length: 6 mm 0.236 in) hexagon-socket
head bolts for side mounting
SF4B-C SERIES
551 Compact Safety Light Curtain Type 4
FIBER
SENSORS
ORDER GUIDE
LASER 4 5 Mating cables
SENSORS
PHOTO-
ELECTRIC
SENSORS
Type Appearance Model No. Description
MICRO
PHOTO-
Length: 3 m 9.843 ft
With connector on
ELECTRIC SFB-CC3-MU Cable with connector on one end for pigtailed type (with
SENSORS Net weight: 430 g approx. (2 cables) muting function)
AREA Two cables per set for emitter and receiver
SENSORS Length: 7 m 22.966 ft
4 SFB-CC7-MU
Net weight: 1,000 g approx. (2 cables)
Cable color: Gray for emitter,
one end
PRESSURE /
FLOW
Length: 3 m 9.843 ft
With connectors on both ends
SENSORS
For emitter
SFB-CCJ3E-MU
INDUCTIVE
Net weight: 190 g approx. (1 cable)
PROXIMITY Cable with connectors on both ends for pigtailed type
SENSORS
SFB-CCJ10E-MU Length: 10 m 32.808 ft (with muting function)
PARTICULAR Net weight: 660 g approx. (1 cable) Cable color: Gray for emitter,
USE
SENSORS
5 Gray with black line for receiver
Length: 3 m 9.843 ft
For receiver
MEASURE-
MENT Designation Model No. Description
SENSORS
STATIC Min. sensing object for regular checking (ø25 mm ø0.984 in),
CONTROL
DEVICES
Test rod ø25 SF4B-TR25 for hand protection type (min. sensing object ø25 mm ø0.984 in)
LASER
MARKERS
OPTIONS
PLC
FA Use a discrete wire cable to connect to the safety light curtain. Muting function
COMPONENTS
can be used. Compatible with up to Control Category 4.
Slim type
When connecting pigtailed type (with muting function) SF4B-□CA-J05, be sure to
MACHINE
VISION
control SF-C13 order a mating cable separately.
SYSTEMS unit
• Mating cable: SFB-CC□-MU
UV • Extension cable: SFB-CCJ□-MU
CURING
SYSTEMS
Handy-controller
Pigtailed type (with muting function)
Selection
Guide
Designation Appearance Model No.
Safety Light
Curtains
Safety
Control Units
Safety
Components Fix
ed
Floa bla
ting nki
Aux blan ng
Lig iliary king
ht
con emoutput Co
Handy-
trol iss de
ion Mo
Pr nitor
ote
FU Co ct
SFB-HC
NC py
TIO
N
controller 8- 8-
CA
NC
EL
core core
SF4D
EN
TE
R
SF4B/
FUNCTION
SF4B-C included Adapter cable (Accessory) Adapter cable (Accessory) Extension cable
SF4C Handy-controller
Cable set for
BSF4-AH80 cable type SFC-WNC1
SF2B connection Cable type
SF2C
12-core → 8-core
Definition of
Sensing Heights Cable set
+V 0V Adapter cable (Accessory)
Synchronization -
Not used
Synchronization + 8-core 8-core
Control FUNCTION
circuit
CANCEL ENTER
Terminal block
Handy-controller
SF4B-C SERIES
Compact Safety Light Curtain Type 4
552
OPTIONS FIBER
SENSORS
LASER
Metal protection case SENSORS
12 MS-SF4BCH-12 AREA
SENSORS
16 8 MS-SF4BCH-16 SAFETY LIGHT
CURTAINS /
20 MS-SF4BCH-20 SAFETY
COMPONENTS
24 12 MS-SF4BCH-24 PRESSURE /
FLOW
28 MS-SF4BCH-28 SENSORS
32 16 MS-SF4BCH-32 INDUCTIVE
PROXIMITY
36 MS-SF4BCH-36 SENSORS
40 20 MS-SF4BCH-40 PARTICULAR
USE
48 24 MS-SF4BCH-48 SENSORS
56 28 MS-SF4BCH-56 SENSOR
OPTIONS
64 32 MS-SF4BCH-64
72 36 MS-SF4BCH-72 SIMPLE
WIRE-SAVING
UNITS
80 40 MS-SF4BCH-80
88 44 MS-SF4BCH-88 WIRE-SAVING
SYSTEMS
96 48 MS-SF4BCH-96
MEASURE-
Note: In the case of using a metal protection case MS-SF4BCH-□ (optional), make sure to assemble it MENT
SENSORS
with a standard mounting bracket MS-SF4BC-1 (optional).
STATIC
CONTROL
DEVICES
Others
LASER
MARKERS
Designation Model No. Description
PLC
Min. sensing object for regular checking (ø45 mm ø1.772 in),
Test rod ø45 SF4B-TR45 for arm / foot protection type (min. sensing object ø45 mm HUMAN
MACHINE
ø1.772 in) INTERFACES
ENERGY
MANAGEMENT
●Recommended safety relay SOLUTIONS
SF4D
SF4B/
SF4B-G
Safety control unit SF4B-C
SF4C
Creating safety circuits is easier than ever.
SF-C21
BSF4-AH80
SF2B
SF2C
FIBER
SENSORS
SPECIFICATIONS
LASER
SENSORS Safety light curtain individual specifications
PHOTO- SF4B-H□C(A-J05)
ELECTRIC
SENSORS Type Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)
MICRO
Pigtailed type SF4B-H12CA-J05 SF4B-H16CA-J05 SF4B-H20CA-J05 SF4B-H24CA-J05 SF4B-H28CA-J05 SF4B-H32CA-J05 SF4B-H36CA-J05
Model No.
PHOTO-
ELECTRIC
SENSORS Item Cable type SF4B-H12C SF4B-H16C SF4B-H20C SF4B-H24C SF4B-H28C SF4B-H32C SF4B-H36C
AREA Number of beam channels 12 16 20 24 28 32 36
SENSORS
263.4 mm 343.4 mm 423.4 mm 503.4 mm 583.4 mm 663.4 mm 743.4 mm
SAFETY LIGHT Protective height
CURTAINS / 10.37 in 13.52 in 16.669 in 19.819 in 22.969 in 26.118 in 29.268 in
SAFETY
COMPONENTS Cable type
Current consumption
FLOW
SENSORS indicator turns OFF
type
SIMPLE
WIRE-SAVING Type Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)
UNITS
Pigtailed type SF4B-H40CA-J05 SF4B-H48CA-J05 SF4B-H56CA-J05 SF4B-H64CA-J05 SF4B-H72CA-J05 SF4B-H80CA-J05 SF4B-H88CA-J05
Model No.
WIRE-SAVING
SYSTEMS Item Cable type SF4B-H40C SF4B-H48C SF4B-H56C SF4B-H64C SF4B-H72C SF4B-H80C SF4B-H88C
Number of beam channels 40 48 56 64 72 80 88
MEASURE-
MENT 823.4 mm 983.4 mm 1,143.4 mm 1,303.4 mm 1,463.4 mm 1,623.4 mm 1,783.4 mm
SENSORS Protective height
32.417 in 38.717 in 45.016 in 51.315 in 57.614 in 63.913 in 70.212 in
STATIC
Cable type
Current consumption
CONTROL
DEVICES Emitter: 80 mA or less Emitter: 85 mA or less Emitter: 95 mA or less Emitter: 100 mA or less
When large multi-purpose Receiver: 100 mA or less Receiver: 120 mA or less Receiver: 130 mA or less Receiver: 140 mA or less
Pigtailed
When large multi-purpose Emitter: 90 mA or less Emitter: 95 mA or less Emitter: 105 mA or less Emitter: 110 mA or less
indicator lights up Receiver: 110 mA or less Receiver: 130 mA or less Receiver: 140 mA or less Receiver: 155 mA or less
PLC PFHD 3.5 × 10−9 3.9 × 10−9 4.4 × 10−9 4.8 × 10−9 5.3 × 10−9 5.7 × 10−9 6.2 × 10−9
HUMAN
MTTFD 100 years or more
MACHINE Pigtailed type 910 g approx. 1,100 g approx. 1,300 g approx. 1,400 g approx. 1,600 g approx. 1,700 g approx. 1,800 g approx.
INTERFACES Net weight
(Total of emitter and receiver) Cable type 1,300 g approx. 1,400 g approx. 1,600 g approx. 1,700 g approx. 2,000 g approx. 2,000 g approx. 2,100 g approx.
ENERGY
MANAGEMENT
SOLUTIONS
FA SF4B-A□C(A-J05)
COMPONENTS
Min. sensing object ø25 mm ø0.984 in Min. sensing object ø45 mm ø1.772 in
MACHINE Type
VISION (20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch)
SYSTEMS
Pigtailed type SF4B-H96CA-J05 SF4B-A8CA-J05 SF4B-A12CA-J05 SF4B-A16CA-J05 SF4B-A20CA-J05
Model No.
UV
CURING Item Cable type SF4B-H96C SF4B-A8C SF4B-A12C SF4B-A16C SF4B-A20C
SYSTEMS
Number of beam channels 96 8 12 16 20
1,943.4 mm 343.4 mm 503.4 mm 663.4 mm 823.4 mm
Protective height
76.512 in 13.52 in 19.819 in 26.118 in 32.417 in
Cable type
Current consumption
Selection
Guide indicator turns OFF
Safety Light
type
Curtains When large multi-purpose Emitter: 115 mA or less Emitter: 70 mA or less Emitter: 75 mA or less
Safety indicator lights up Receiver: 155 mA or less Receiver: 80 mA or less Receiver: 85 mA or less
Control Units PFHD 6.6 × 10−9 1.7 × 10−9 1.9 × 10−9 2.2 × 10−9 2.4 × 10−9
Safety
Components MTTFD 100 years or more 100 years or more
Net weight Pigtailed type 1,900 g approx. 430 g approx. 590 g approx. 750 g approx. 910 g approx.
(Total of emitter and receiver) Cable type 2,200 g approx. 770 g approx. 930 g approx. 1,100 g approx. 1,300 g approx.
SF4D
SF4B/
SF4B-G Type Min. sensing object ø45 mm ø1.772 in (40 mm 1.575 in beam pitch)
SF4B-C Pigtailed type SF4B-A24CA-J05 SF4B-A28CA-J05 SF4B-A32CA-J05 SF4B-A36CA-J05 SF4B-A40CA-J05 SF4B-A44CA-J05 SF4B-A48CA-J05
Model No.
SF4C Item Cable type SF4B-A24C SF4B-A28C SF4B-A32C SF4B-A36C SF4B-A40C SF4B-A44C SF4B-A48C
BSF4-AH80 Number of beam channels 24 28 32 36 40 44 48
983.4 mm 1,143.4 mm 1,303.4 mm 1,463.4 mm 1,623.4 mm 1,783.4 mm 1,943.4 mm
SF2B Protective height
38.717 in 45.016 in 51.315 in 57.614 in 63.913 in 70.212 in 76.512 in
SF2C Cable type
Current consumption
SPECIFICATIONS FIBER
SENSORS
(20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch) (20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch) MICRO
PHOTO-
ELECTRIC
Item Model No. SF4B-H□CA-J05 SF4B-A□CA-J05 SF4B-H□C SF4B-A□C SENSORS
International standard IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Applicable standards
AREA
Japan JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3) SENSORS
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), SAFETY LIGHT
Europe (EU) (Note 2) CURTAINS /
EN 55011, EN 50178, EN 61000-6-2 SAFETY
COMPONENTS
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,
North America (Note 3) PRESSURE /
OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 FLOW
SENSORS
South Korea (S-Mark) S1-G-35-2005, S2-W-11-2003
CE marking directive compliance Machine Directive, EMC Directive, RoHS Directive INDUCTIVE
PROXIMITY
Operating range (Note 4) 0.3 to 7 m 0.984 to 22.966 ft SENSORS
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +60 °C –3 to +140 °F SF4C
Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH
BSF4-AH80
Ambient illuminance Incandescent light: 3,500 ℓx or less at the light-receiving face
Dielectric strength voltage / 1,000 V AC for one min. between all supply terminals connected together and enclosure / 20 MΩ or more, with 500 V DC SF2B
Insulation resistance megger between all supply terminals connected together and enclosure
SF2C
Vibration resistance / 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each / 300 m/s2 acceleration
Definition of
Shock resistance (30 G approx.) in X, Y and Z directions for three times each Sensing Heights
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
3) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized
safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
4) The operating range is the possible setting distance between the emitter and the receiver.
5) In case the blanking function is valid, the operation mode is changed.
6) During muting, control output will not turn off even if the beams are interrupted.
7) When the blanking function is enabled, the operating mode will change.
8) The manual reset and automatic reset are possible to be switched depending on the wiring status.
9) In case of using optional function, the handy-controller SFB-HC (optional) is required.
10) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
SF4B-C SERIES
555 Compact Safety Light Curtain Type 4
FIBER
SENSORS
SPECIFICATIONS
LASER
SENSORS Safety light curtain common specifications
PHOTO- Pigtailed type (with muting function) Cable type
ELECTRIC
SENSORS
Type Min. sensing object Min. sensing object Min. sensing object Min. sensing object
MICRO ø25 mm ø0.984 in ø45 mm ø1.772 in ø25 mm ø0.984 in ø45 mm ø1.772 in
PHOTO-
ELECTRIC (20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch) (20 mm 0.787 in beam pitch) (40 mm 1.575 in beam pitch)
SENSORS
Item Model No. SF4B-H□CA-J05 SF4B-A□CA-J05 SF4B-H□C SF4B-A□C
AREA
SENSORS Emitting element Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
SAFETY LIGHT Material Enclosure: Polycarbonate
CURTAINS /
SAFETY 0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC 0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC
COMPONENTS Cable
cable with connector, 0.5 m 1.640 ft long cable, 5 m 16.404 ft long
PRESSURE /
FLOW Extension up to total 50 m 164.042 ft is possible for both Extension up to total 50 m 164.042 ft is possible for 0.2 mm2
SENSORS Cable extension
emitter and receiver optional mating cables or more, cable (Note)
INDUCTIVE Accessories SF4B-TR25 (Test rod): 1 pc. SF4B-TR25 (Test rod): 1 pc.
PROXIMITY
SENSORS
Note: When the synchronization + wire (orange) and synchronization - wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or
PARTICULAR more shielded twisted pair cable.
USE
SENSORS
SENSOR
OPTIONS Handy-controller
SIMPLE
WIRE-SAVING Model No.
UNITS SFB-HC
Item
WIRE-SAVING
SYSTEMS Supply voltage 24 V DC ±10 % Ripple P-P10 % or less (common to safety light curtain power supply)
Current consumption 65 mA or less
MEASURE-
MENT Communication method RS-485 two-way communications (Specific procedure)
SENSORS
Digital display 4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.)
STATIC
CONTROL Function indicator Green LED × 9 (set function is displayed.)
DEVICES
Fixed blanking (Factory setting: Disabled) / Floating blanking (Factory setting: Disabled)
LASER / Auxiliary output changing (Factory setting: Negative Logic of OSSD) / Light emitting amount control (Factory
MARKERS
setting: Disabled)
/ Muting setting changing [Factory setting: All beam channels enabled, A = B, Setting of the muting lamp diagnosis
PLC function enabled (Ver. 2 or later), Muting sensor output operation setting N.O. / N.C.
Functions
(Ver. 2.1 or later)]
HUMAN / Interlock setting changing (Factory setting: start / restart)
MACHINE
INTERFACES / External device monitoring setting change (Factory setting: Enabled, 300 ms)
/ Override setting changing 60 sec. (Ver. 2.1 or later) / Setting detail monitoring /
ENERGY
MANAGEMENT / Protecting (Factory setting: Disabled) (Factory password setting: 0000) / Initialization / Copy
SOLUTIONS
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
FA Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH
COMPONENTS
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
MACHINE Insulation resistance 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
VISION
SYSTEMS Cable 8-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables)
UV Weight Net weight: 200 g approx.
CURING
SYSTEMS Accessory Adapter cable: 2 cables
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
Selection
Guide
Safety Light
Curtains
Safety
Control Units
Safety
Components
SF4D
SF4B/
SF4B-G
SF4B-C
SF4C
BSF4-AH80
SF2B
SF2C
Definition of
Sensing Heights
SF4B-C SERIES
Compact Safety Light Curtain Type 4
556
SPECIFICATIONS FIBER
SENSORS
LASER
Control unit SENSORS
Connectable safety light curtains Safety light curtains manufactured by Panasonic Industrial Devices SUNX MICRO
PHOTO-
ELECTRIC
EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), SENSORS
Applicable standards ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4),
ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) AREA
SENSORS
CE marking directive compliance Machinery Directive, Low Voltage Directive, EMC Directive, RoHS Directive SAFETY LIGHT
Control category ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards CURTAINS /
SAFETY
Supply voltage 24 V DC ±10 % Ripple P-P 10 % or less COMPONENTS
PRESSURE /
Current consumption 100 mA or less (without safety light curtain) FLOW
SENSORS
Fuse (rating) Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
INDUCTIVE
Safety output NO contact × 3 (13-14, 23-24, 33-34) PROXIMITY
SENSORS
Utilization category AC-15, DC-13 (IEC 60947-5-1)
Rated operation voltage (Ue) / 30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection) PARTICULAR
USE
Rated operation current (le) Min. applicable load: 10 mA (at 24 V DC) (Note 2) SENSORS
Contact material / contacts AgSnO, self cleaning, positively driven SENSOR
Contact resistance 100 mΩ or less (initial value) OPTIONS
ENERGY
Safety output [OUT] Green LED (lights up when enabling contacts are closed) MANAGEMENT
SOLUTIONS
Interlock (INTER_LOCK) Yellow LED (lights up when enabling contacts are opened)
Fault (FAULT) Yellow LED (blinks when fault occurs) FA
COMPONENTS
External relay monitor function Incorporated
MACHINE
Trailing edge function Incorporated VISION
SYSTEMS
Incorporated (Cable connection allows selection of plus/minus ground)
Polarity selection function
Minus ground: Correspond to PNP output safety light curtain UV
(Note 4) CURING
Plus ground: Correspond to NPN output safety light curtain SYSTEMS
Pollution degree 2
Protection Enclosure: IP40, Terminal: IP20
Environmental
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
resistance
3) Relay switching lifetime will vary depending on factors such as the type of load, the switching 4
current (A)
SF4B-C
frequency, and ambient conditions. 3
4) Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus SF4C
ground. 2
BSF4-AH80
1
SF2B
0 35 40 45 50 55
32 95 104 113 122 131 SF2C
Ambient Definition of
temperature (°C °F) Sensing Heights
SF4B-C SERIES
557 Compact Safety Light Curtain Type 4
・
FIBER
SENSORS
I/O CIRCUIT AND WIRING DIAGRAMS
LASER
SENSORS SF4B-□CA-J05 Pigtailed type (with muting function)
PHOTO-
ELECTRIC I/O circuit diagrams
SENSORS
MICRO <In case of using I/O circuit for PNP output> <In case of using I/O circuit for NPN output>
PHOTO-
ELECTRIC
SENSORS Terminal No. of pigtailed type Terminal No. of pigtailed type
Emitter Emitter
AREA Lead wire color of mating cable Lead wire color of mating cable
SENSORS
(Brown) +V (Brown) +V
SAFETY LIGHT
CURTAINS / (Yellow) Override input (Shield) Output polarity setting wire
SAFETY Load
COMPONENTS 0.22 μF 470 Ω (Red) Muting auxiliary output
*S1
PRESSURE /
FLOW Load Load
0.22 μF 470 Ω (Pink) Emission halt input /
SENSORS *S1
Reset input
INDUCTIVE 0.22 μF 470 Ω (Pale purple) Interlock setting input
PROXIMITY *S1 (Yellow-green / Black) Auxiliary output
SENSORS
(Red) Muting auxiliary output
PARTICULAR (Gray / Black) Large multi-purpose *S1
Sensor circuit
+
Sensor circuit
USE + 24 V DC 24 V DC
SENSORS indicator input (Emitter side)
±10 % – ±10 %
–
(Yellow-green / Black) Auxiliary output
SENSOR
OPTIONS
(Gray) NC *S1
(Gray / Black) Large multi-purpose *S1
SIMPLE indicator input (Emitter side)
WIRE-SAVING 0.22 μF 470 Ω (Pale purple) Interlock setting input
UNITS
Load
WIRE-SAVING 0.22 μF 470 Ω (Pink) Emission halt input /
(Gray) NC *S1
SYSTEMS Reset input
(Shield) Output polarity setting wire 0.22 μF 470 Ω (Yellow) Override input
MEASURE- *S1
MENT (Blue) 0 V
SENSORS (Blue) 0 V
VISION *S1
SYSTEMS (White) Control output 2 (OSSD 2)
Sensor circuit
Emitter
Switch S1
HUMAN
• Emission halt input / Reset input MACHINE
INTERFACES
For automatic reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note)
Open: Emission halt ENERGY
MANAGEMENT
For manual reset Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note) SOLUTIONS
Open: Emission (Yellow-green) External device monitor input
• Muting input A / B, Override input FA
COMPONENTS
Vs to Vs – 2.5 V (sink current 5 mA or less): Valid (Note), Open: Invalid
MACHINE
Note: Vs is the applying supply voltage. VISION
SYSTEMS
<In case of using I/O circuit for NPN output>
UV
Lead wire color of mating cable CURING
SYSTEMS
(Gray) NC The diagram at left shows the configuration when using NPN
(Gray / Black) Large multi-purpose indicator input (Emitter side) output, interlock function “disabled (automatic reset)”
(Pale purple) Interlock setting input and external device monitoring function “enabled”.
Gray
cable (Brown) +V
(Yellow-green / Black) Auxiliary output In case of setting the interlock function to “enabled (manual reset)”
Load Selection
(Shield) Output polarity setting wire • When the interlock function is set to “Enable (manual Guide
Receiver
Emitter
・
FIBER
SENSORS
I/O CIRCUIT AND WIRING DIAGRAMS
LASER
SENSORS SF4B-□C Cable type
PHOTO-
ELECTRIC I/O circuit diagrams
SENSORS
MICRO <In case of using I/O circuit for PNP output> <In case of using I/O circuit for NPN output>
PHOTO-
ELECTRIC
SENSORS Emitter Lead wire color Emitter Lead wire color
AREA
SENSORS (Brown) +V (Brown) +V
SAFETY LIGHT (Pale purple) Interlock setting input (Shield) Output polarity setting wire
CURTAINS /
SAFETY 0.22 μF 470 Ω
COMPONENTS (Pink) Emission halt input / Reset input *S1 Load
PRESSURE /
FLOW 0.22 μF 470 Ω (Yellow-green / Black) Auxiliary output
SENSORS
*S1
+
Sensor circuit
Sensor circuit
+ 24 V DC 24 V DC
INDUCTIVE (Yellow-green / Black) Auxiliary output ±10 % – ±10 %
PROXIMITY –
SENSORS *S1
(Pale purple) Interlock setting input
PARTICULAR
USE Load 0.22 μF 470 Ω *S1
SENSORS (Shield) Output polarity setting wire (Pink) Emission halt input / Reset input
K2
PLC
HUMAN
MACHINE
INTERFACES (White) Control output 2 (OSSD 2) (White) Control output 2 (OSSD 2)
ENERGY K1
MANAGEMENT
SOLUTIONS
K2
(Shield) Output polarity setting wire
FA (Yellow-green) External device monitor input K1 K2
COMPONENTS
(Blue) 0 V 0.22 μF 470 Ω (Blue) 0 V
MACHINE K1, K2: External device
VISION K1, K2: External device
SYSTEMS (Forced guided relay or magnetic contactor)
Internal circuit Users’ circuit (Forced guided relay or magnetic contactor)
Internal circuit Users’ circuit
UV
CURING
SYSTEMS *S1 *S1
Switch S1 Switch S1
• Emission halt input / Reset input • Emission halt input / Reset input
For manual reset For manual reset
Vs to Vs – 2.5 V (sink current 5 mA or less): Emission halt (Note) 0 to +1.5 V (source current 5 mA or less): Emission halt
Selection Open: Emission Open: Emission
Guide
Safety Light
For automatic reset For automatic reset
Curtains Vs to Vs – 2.5 V (sink current 5 mA or less): Emission (Note) 0 to +1.5 V (source current 5 mA or less): Emission
Safety Open: Emission halt Open: Emission halt
Control Units
Safety • Interlock setting input • Interlock setting input
Components Vs to Vs – 2.5 V (sink current 5 mA or less): Valid (Note) 0 to +1.5 V (source current 5 mA or less): Valid, Open: Invalid
Open: Invalid
SF4C
BSF4-AH80
SF2B
SF2C
Definition of
Sensing Heights
SF4B-C SERIES
Compact Safety Light Curtain Type 4
560
・
I/O CIRCUIT AND WIRING DIAGRAMS FIBER
SENSORS
LASER
SF4B-□C Cable type SENSORS
AREA
The diagram at left shows the configuration when using PNP SENSORS
Lead wire color output, interlock function “enabled (manual reset)” and external SAFETY LIGHT
device monitoring function “enabled”. CURTAINS /
SAFETY
(Brown) +V COMPONENTS
Receiver
Emitter
Emitter
SF2C
*S1
(Yellow-green / Black) Auxiliary output Definition of
Switch S1 Sensing Heights
• Emission halt input / Reset input Receiver
For manual reset
0 to +1.5 V (source current 5 mA or less): Emission halt
Open: Emission
For automatic reset
0 to +1.5 V (source current 5 mA or less): Emission
Open: Emission halt
• Interlock setting input (Yellow-green) External device monitor input
0 to +1.5 V (source current 5 mA or less): Valid, Open: Invalid
SF4B-C SERIES
561 Compact Safety Light Curtain Type 4
・
FIBER
SENSORS
I/O CIRCUIT AND WIRING DIAGRAMS
LASER
SENSORS SF-C13
PHOTO-
ELECTRIC SF4B-□C wiring diagrams (Control Category 4)
SENSORS
MICRO For PNP output (minus ground) For NPN output (plus ground)
PHOTO-
ELECTRIC
SENSORS • Connect the safety light curtain control outputs OSSD 1 • Connect the safety light curtain control outputs OSSD 1
AREA and OSSD 2 to S1 and S2 respectively. and OSSD 2 to S4 and S2 respectively and ground the +
SENSORS side.
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS Emitter Receiver Emitter Receiver
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY Cable color:
SENSORS Cable color:
Cable color: Gray Gray with black line Cable color: Gray Gray with black line
PARTICULAR
USE
SENSORS Synchronization+
Synchronization+ +V (Brown)
+V (Brown) (Orange) (Orange)
+24 V DC +24 V DC
SENSOR Synchronization- Synchronization-
OPTIONS (Orange / Black) (Orange / Black)
Emission
SIMPLE Output polarity halt input / Auxiliary output Interlock setting Output polarity Emission Auxiliary output Interlock setting
input (Pale purple) setting wire halt input / Yellow-green input (Pale purple) Output
WIRE-SAVING setting wire Reset input Yellow-green Output polarity
UNITS (Shield) (Pink) / Black Open +V (Brown) (Shield) Reset input / Black Open
polarity (Pink) +V (Brown) setting wire
setting wire 0 V (Blue) Load (Shield)
WIRE-SAVING 0 V (Blue) Load 0 V (Blue) (Shield)
SYSTEMS 0 V (Blue)
External device monitor input (Yellow-green) External device monitor input (Yellow-green)
MEASURE-
MENT OSSD 1 (Black) OSSD 2 (White)
SENSORS
OSSD 2 (White) OSSD 1 (Black)
STATIC
CONTROL L1 L1
DEVICES
RESET
LASER (Note 1, 2) (Note 1) (Note 1) FUSE1 FUSE2
MARKERS
FUSE1 FUSE2
A1 S1 S2 S3 S4 X1 X2 X3 13 23 33 41 A1 S1 S2 S3 S4 X1 X2 X3 13 23 33 41
F.G.
PLC RESET
F F K1 (Note 1, 2)
K1
HUMAN Ui SF-C13 control circuit
MACHINE Ui SF-C13 control circuit
INTERFACES
K2 K2
ENERGY OUT INTER_LOCK FAULT
MANAGEMENT OUT INTER_LOCK FAULT
SOLUTIONS L1L2L3 L1L2L3
A2 AUX 14 24 34 42 KB A2 AUX 14 24 34 42 KB
FA KB KA 0V KB KA
COMPONENTS 0V F.G. KA KA
N N
MACHINE KA, KB: External device M KA, KB: External device M
VISION (Forced guided relay or magnetic contactor) 3 (Forced guided relay or magnetic contactor) 3
SYSTEMS
UV Notes: 1) The above diagram is when using manual reset. If automatic reset Notes: 1) The above diagram is when using manual reset. If automatic reset
CURING is used, disconnect the lead from X2 and connect it to X3. In this is used, disconnect the lead from X2 and connect it to X3. In this
SYSTEMS
case, a reset (RESET) button is not needed. case, a reset (RESET) button is not needed.
2) Use a momentary-type switch as the reset (RESET) button. 2) Use a momentary-type switch as the reset (RESET) button.
PHOTO-
Refer to the applicable regulations for the Install the safety light curtain by considering ELECTRIC
SENSORS
region where this device is to be used when the effect of nearby reflective surfaces, and
MICRO
setting up the device. In addition, make sure take countermeasures such as painting, PHOTO-
ELECTRIC
that all necessary measures are taken to masking, or changing the material of the SENSORS
prevent possible dangerous operating errors reflective surface, etc. Failure to do so may AREA
SENSORS
resulting from earth faults. cause the safety light curtain not to detect,
resulting in serious body injury or death. SAFETY LIGHT
CURTAINS /
• Make sure to carry out the wiring in the power supply off SAFETY
COMPONENTS
condition. • Install this device at a distance of at least A (m) (given
PRESSURE /
• Verify that the supply voltage variation is within the rating. below) away from reflective surfaces such as metal FLOW
SENSORS
• If power is supplied from a commercial switching walls, floors, ceilings, workpiece, covers, panels or glass INDUCTIVE
regulator, ensure that the frame ground (F.G.) terminal of surfaces. PROXIMITY
SENSORS
the power supply is connected to an actual ground. PARTICULAR
• In case noise generating equipment (switching regulator, Side view Top view USE
SENSORS
inverter motor, etc.) is used in the vicinity of this
Reflective ceiling Reflective surface
sensor, connect the frame ground (F.G.) terminal of the SENSOR
OPTIONS
equipment to an actual ground. Emitter
A
Receiver
A SIMPLE
• Do not run the wires together with high-voltage lines or Emitter θ
θ
Receiver WIRE-SAVING
UNITS
power lines or put them in the same raceway. This can Sensing range
cause malfunction due to induction. L WIRE-SAVING
SYSTEMS
Sensing range
L MEASURE-
A
Others MENT
SENSORS
Reflective floor
• This device has been developed / produced for industrial STATIC
CONTROL
use only. 0.5 DEVICES
1.640
• Do not use during the initial transient time (2 sec.) after Distance LASER
direct contact with water, oil, grease, or organic solvents, distance L 0.2
HUMAN
MACHINE
such as, thinner, etc. 0.3 to 3 m 0.656 INTERFACES
Do not install in this area
• Take care that the safety light curtain is not directly 0.984 to 0.16 m 0.525 ft 0.1
ENERGY
MANAGEMENT
exposed to fluorescent light from a rapid-starter lamp or a 9.843 ft 0.328 SOLUTIONS
high frequency lighting device, as it may affect the sensing 3 to 7 m L/2 × tan2θ =
FA
9.843 to L/2 × 0.105 (m)
performance. 22.966 ft 0.344 (ft) (θ = 3°)
0 1
3.281
3 5
9.843 16.404 22.966
7 9
29.528
COMPONENTS
mode”, an appropriate control circuit must L > 3 m 9.843 ft) as required by IEC 61496-2, ANSI/UL 61496-2. UV
CURING
be configured between this device and the However, install this device away from reflective surfaces considering SYSTEMS
machinery. For details, be sure to refer to the an effective aperture angle of ±3° to take care of beam misalignment,
standards or regulations applicable in each etc. during installation.
region or country.
Handy-controller
Selection
Guide
• This catalog is a guide to select a suitable product. Be This device enables to set each function Safety Light
sure to read instruction manual prior to its use. using the handy-controller SFB-HC (optional).
Curtains
Safety
• Both emitter and receiver are adjusted before Among the functions, the contents related to Control Units
shipment, please apply both emitter and receiver with the safety distance such as the size of the Safety
Components
the same serial No. The serial No. is indicated on the minimum sensing object and response time
plates of both emitter and receiver. (Indicated under are varied depending on the setting condition.
model No.) When setting each function, re-calculate the SF4D
SF2C
• Refer to the instruction manual of the handy-controller Definition of
for details of the function settings for using handy- Sensing Heights
controller SFB-HC (optional).
SF4B-C SERIES
563 Compact Safety Light Curtain Type 4
・
FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・
LASER
SENSORS SF4B-□CA-J05 SF4B-□C MS-SF4BC-1
Safety light curtain
PHOTO-
ELECTRIC Assembly dimensions 27.4
2 2
27.4
SENSORS 1.079 1.079
0.079 0.079
MICRO The figure depicts rear mounting using the standard mounting bracket MS-SF4BC-1
19.6 (optional) and the intermediate
19.6 supporting bracket for
PHOTO- 0.772
ELECTRIC standard mounting bracket MS-SF4BC-5 (optional).
MS-SF4BC-5
0.772
SENSORS
20 0.787 6 × M3 mounting hole 20 0.787
AREA Protective height
SENSORS MS-SF4BC-1 for countersunk screw
33 33
SAFETY LIGHT 5 27.4 1.299 27.4 1.299 5
CURTAINS / 2 120 2 120 0.197
B 0.197 1.079 D A A 1.079 D
4.724 C
SAFETY 0.079 0.079 C 4.724
COMPONENTS 19.6 19.6
2 0.079 2 0.079
PRESSURE / 0.772 108 0.772 108
FLOW MS-SF4BC-5 4.252 4.252
SENSORS
INDUCTIVE
20 0.787 6 × M3 mounting holeF Protective height
20 0.787
3.2
F
PROXIMITY for countersunk screw (3.2 0.126)
0.126
SENSORS 33 33
5 1.299 1.299 5
E 120 120
PARTICULAR B 0.197 D
4.724 C
A (46.6 1.835) H A C 4.724 D H (46.6 1.835) 2 0.197 B E
USE Beam pitch 0.079 5.4
SENSORS 2 0.079 5.4 0.213 (2 0.079) G 2 0.079
G 0.213
108 108
SENSOR
4.252 4.252
OPTIONS
F 5.4 0.213 ø5 ø0.197 Gray cable 5.4 0.213 F
(3.2 0.126) 2 0.079 10.7 0.421 ø5 ø0.197 3.2 0.465 10.7 2
SIMPLE 10 0.394 11.8 0.465 11.8
0.126 10 0.394 0.421 0.079
WIRE-SAVING 29.9 Gray cable 29.9
UNITS 1.177 21.6 0.850 (with black line) 21.6 0.850 1.177
E H H E
(46.6 1.835) (46.6 1.835) 2
Beam pitch 0.079 5.4
WIRE-SAVING 5.4 0.213 (2 0.079) G G 0.213
SYSTEMS
MEASURE-
MENT
SENSORS 5.4 0.213 ø5 ø0.197 Gray cable 5.4 0.213
2 0.079 10.7 0.421 ø5 ø0.197 10.7 2
10 0.394 11.8 0.465 11.8 0.465 10 0.394
0.421 0.079
STATIC 29.9 Gray cable 29.9
CONTROL 1.177 21.6 0.850 (with black line) 21.6 0.850 1.177
DEVICES
PLC
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
HUMAN
MACHINE (45 1.772)
INTERFACES
ø15.6 ø0.614
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
D
MACHINE Model
(45 1.772)No. A B C E F
VISION SF4B-H□C(A-J05) SF4B-A□C(A-J05)
SYSTEMS
ø15.6 ø0.614
294.4 279 263.4
UV SF4B-H12C(A-J05) 11.591 10.984 10.370
220
8.661 — — —
CURING
SYSTEMS
374.4 359 343.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 14.740 14.134 13.520
300
11.811 280
11.024 — —
Model No. G H
SF4B-H□C(A-J05) 21.7 0.854 20 0.787
LASER
SF4B-□CA-J05 SF4B-□C MS-SF4BC-1
Safety light curtain SENSORS
MEASURE-
MENT
10.7 0.421 10 0.394 ø5 ø0.197 10 SENSORS
11.8 0.465 ø5 ø0.197 Gray cable 11.8 0.465 0.394 10.7 0.421
29.9 Gray cable 29.9
21.6 0.850 (with black line) 21.6 0.850 STATIC
1.177 1.177 CONTROL
DEVICES
Emitter Receiver
LASER
MARKERS
PLC
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
HUMAN
(45 1.772) MACHINE
INTERFACES
ø15.6 ø0.614 ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
D
Model
(45 1.772) No. A B C J K MACHINE
SF4B-H□C(A-J05) SF4B-A□C(A-J05) VISION
ø15.6 ø0.614 SYSTEMS
294.4 279 263.4
SF4B-H12C(A-J05) 11.591 10.984 10.370
220
8.661 — — — UV
CURING
SYSTEMS
374.4 359 343.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 14.740 14.134 13.520
300
11.811 280
11.024 — —
Model No. G H
SF4B-H□C(A-J05) 21.7 0.854 20 0.787
・
FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・
LASER
SENSORS SF4B-□CA-J05 SF4B-□C Safety light curtain
PHOTO-
ELECTRIC Assembly dimensions
SENSORS
MICRO The figure depicts rear mounting using the rear utility mounting bracket MS-SF4BC-2 (optional) and the intermediate supporting bracket for
PHOTO-
ELECTRIC utility mounting bracket MS-SF4BC-4 (optional).
SENSORS
AREA
SENSORS
19.6 (4.2 0.165) (4.2 0.165) 19.6 19.6 (4.2 0.165) (4.2 0.165)
SAFETY LIGHT (4.2 0.165) (4.2 0.165)
CURTAINS / 19.6 (4.2 0.165) 0.772 MS-SF4BC-2 19.6 19.6 0.772 0.772 (4.2 0.165) 19.6
SAFETY 0.772 MS-SF4BC-2 0.772 0.772 0.772
COMPONENTS 32.2 32.2
PRESSURE / 32.2 32.2 1.268 1.268
10.8 10.8
FLOW 1.268 0.425 1.268 0.425
SENSORS 10.8 10.8
0.425
5.4 0.213 0.425 5.4 0.213
INDUCTIVE 5.4 0.213 Protective 5.4 0.213
PROXIMITY Protective height
SENSORS height
L D 120 M M 120 D L
PARTICULAR B 120 M 120 4.724 4.724
USE B 4 D
L 0.417
10.6 M D L
SENSORS 4.724 4.724 B
4 10.6 0.417 0.157 MS-SF4BC-4 108 108 10.6 0.417
0.157 MS-SF4BC-4 108 4.252 108 4.252
10.6 0.417 4
SENSOR 4.252
OPTIONS 4.252 0.157
P P
SIMPLE P
WIRE-SAVING
UNITS
N (47.1 1.854) H H (47.1 1.854)
H H Beam pitch
WIRE-SAVING N (47.1 1.854) (47.1 1.854) N
SYSTEMS 5.4 0.213 Beam pitch
Q Q 5.4 0.213
5.4 0.213 Q Q 5.4 0.213
MEASURE-
MENT
SENSORS ø5 ø0.197 Gray cable ø5 ø0.197 Gray cable
STATIC 8 0.315 10 0.394 ø5 ø0.197 Gray cable ø5 ø0.197 Gray14cable (with black line) 10 0.394
8 0.315 10 0.394 14 0.551 0.551 10 0.394 8 0.315
CONTROL 23.8 (with black line) 23.8
DEVICES 14 0.551 14 0.551
23.8 0.937 23.8 0.937
0.937 0.937
LASER
MARKERS Emitter Receiver
PLC
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
HUMAN
MACHINE (45 1.772)
INTERFACES (45 1.772)
ENERGY ø15.6 ø0.614
MANAGEMENT ø15.6 ø0.614
SOLUTIONS
FA
COMPONENTS
D
MACHINE Model No. B L M N P
VISION SF4B-H□C(A-J05) SF4B-A□C(A-J05)
SYSTEMS
279 316.4 264.4
UV SF4B-H12C(A-J05) 10.984
220
8.661 —
12.457 10.409
— —
CURING
SYSTEMS
359 396.4 344.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 14.134
300
11.811 280
11.024
15.606 13.559
— —
Model No. H Q
SF4B-H□C(A-J05) 20 0.787 22.2 0.874
LASER
SF4B-□CA-J05 SF4B-□C Safety light curtain SENSORS
S Q Q WIRE-SAVING
5.4 0.213 (47.1 1.854) H Beam pitch H (47.1 1.854) 5.4 0.213
SYSTEMS
14 0.551 Q 14 0.551 Q
8 0.315 10 0.394 ø5 ø0.197 Gray cable 10 0.394 8 0.315 MEASURE-
MENT
ø5 ø0.197 Gray cable SENSORS
23.8 (with black line) 23.8
0.937 8 0.315 10 0.394 14 0.551 ø5 ø0.197 Gray cable 14 0.551 0.937 10STATIC
0.394
ø5 ø0.197 Gray cable CONTROL
23.8 23
Emitter
0.937 Receiver
(with black line) DEVICES
0.9
LASER
MARKERS
PLC
<Connector of
(45the pigtailed type (with muting function) SF4B-□CA-J05>
1.772)
HUMAN
ø15.6 ø0.614 (45 1.772) MACHINE
INTERFACES
FA
COMPONENTS
D
Model No. M R S T U MACHINE
SF4B-H□C(A-J05) SF4B-A□C(A-J05) VISION
SYSTEMS
264.4 245.8 270.4
SF4B-H12C(A-J05) 220
8.661 —
10.409 9.677
— —
10.646 UV
CURING
SYSTEMS
344.4 325.8 350.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 300
11.811 280
11.024
13.559 12.827
— —
13.795
424.4 405.8 430.4
SF4B-H20C(A-J05) 380
14.961 —
16.709 17.748
— —
16.945
504.4 485.8 510.4
SF4B-H24C(A-J05) SF4B-A12C(A-J05) 460
18.110 440
17.323
19.858 19.126
— —
20.094 Selection
Guide
584.4 565.8 590.4 Safety Light
SF4B-H28C(A-J05) 540
21.260 —
23.008 22.276
— —
23.244 Curtains
Safety
664.4 645.8 670.4 Control Units
SF4B-H32C(A-J05) SF4B-A16C(A-J05) 620
24.409 600
23.622
26.157 25.425
— —
26.394 Safety
Components
744.4 725.8 750.4
SF4B-H36C(A-J05) 700
27.559 —
29.307 28.575
— —
29.543
824.4 805.8 382.9 830.4 SF4D
SF4B-H40C(A-J05) SF4B-A20C(A-J05) 780
30.709 760
29.921
32.457 31.724 15.075
—
32.693
SF4B/
984.4 965.8 462.9 990.4 SF4B-G
SF4B-H48C(A-J05) SF4B-A24C(A-J05) 940
37.008 920
36.220
38.756 38.024 18.224
—
38.992 SF4B-C
1,144.4 1,125.8 542.9 1,150.4
SF4B-H56C(A-J05) SF4B-A28C(A-J05) 1,100 43.307 1,080 42.520
45.055 44.323 21.374
—
45.291 SF4C
1,304.4 1,285.8 402.9 841.9 1,310.4 BSF4-AH80
SF4B-H64C(A-J05) SF4B-A32C(A-J05) 1,260 49.606 1,240 48.819
51.354 50.622 15.862 33.146 51.590
SF2B
1,464.4 1,445.8 455.9 948.9 1,470.4
SF4B-H72C(A-J05) SF4B-A36C(A-J05) 1,420 55.906 1,400 55.118
57.654 56.921 17.949 37.358 57.890 SF2C
1,624.4 1,605.8 508.9 1,055.9 1,630.4 Definition of
SF4B-H80C(A-J05) SF4B-A40C(A-J05) 1,580 62.205 1,560 61.417
63.953 63.220 20.035 41.571 64.189 Sensing Heights
1,784.4 1,765.8 561.9 1,162.9 1,790.4
SF4B-H88C(A-J05) SF4B-A44C(A-J05) 1,740 68.504 1,720 67.716
70.252 69.520 22.122 45.783 70.488
1,944.4 1,925.8 614.9 1,269.9 1,950.4
SF4B-H96C(A-J05) SF4B-A48C(A-J05) 1,900 74.803 1,880 74.016
76.551 75.819 24.209 49.996 76.787
Model No. H Q
SF4B-H□C(A-J05) 20 0.787 22.2 0.874
・
FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・
LASER
SENSORS SF4B-□CA-J05 SF4B-□C Safety light curtain
PHOTO-
ELECTRIC Assembly dimensions
SENSORS ・
MICRO The figure depicts side mounting using
・
the side utility mounting bracket MS-SF4BC-3 (optional) and the intermediate supporting bracket for
PHOTO-
ELECTRIC utility mounting bracket MS-SF4BC-4 (optional).
SENSORS
AREA
SENSORS MS-SF4BC-3 MS-SF4BC-3
SAFETY LIGHT (1.3 0.051) (1.3 0.051) (12.9 0.508) (1.3 0.051)
(12.9 0.508) (1.3
CURTAINS /
SAFETY
COMPONENTS 19.6 0.772 19.6 0.772 19.6 0.772 19.6 0.772
PRESSURE /
31.5 1.240 31.5 1.240
34.3 1.350 34.3 1.350 34.3 1.350 34.3 1.350
FLOW
SENSORS 2.3 0.091 2.3 0.091 31.5 1.240 31.5 1.240
12.9 12.9
INDUCTIVE MS-SF4BC-4 MS-SF4BC-4 Protective Protective 0.508 2.3 0.091 2.3 0.091
PROXIMITY height 0.508
height
SENSORS
5 0.197 5 0.197
PARTICULAR
B B D 120 D 120 L M 120 L M 120 B
USE 4.724 M L 4.724 M L 4.724 4.724
SENSORS D D
108 108 108
4.252 108
SENSOR 4.252 4.252 5.4 4.252 5.4
OPTIONS 5.4 0.213 5.4 0.213 0.213 5 0.213 5
P 0.197 0.197
P P
SIMPLE 12.9 12.9
WIRE-SAVING 0.508 Beam
0.508pitch Beam pitch
UNITS
12.9 12.9
27.4 1.079 27.4 1.079H
0.508 0.508 H H (47.1 1.854) 27.4
H 1.079 (47.1 1.854) 27.4 1.079
WIRE-SAVING N N N N
SYSTEMS 5.4 0.213 Q (47.1 1.854) 5.4 0.213 Q (47.1 1.854) Q 5.4 0.213 Q 5.4 0.213
MEASURE-
MENT
SENSORS
ø5 ø0.197 Gray cable ø5 ø0.197 Gray cable ø5 ø0.197 Gray cable
10 0.394 22.7 0.894 ø5 ø0.197 Gray (with
cableblack line) 22.7
STATIC 8.7 0.343 10 0.394 8.7 0.343 22.7 0.894 (with0.894 8.7 0.343
black line) 22.710 0.394 8.7 0.343
0.894 10 0.
CONTROL
DEVICES 28.7 28.7 28.7 28.7
1.130 1.130 1.130 1.130
LASER Emitter Receiver
MARKERS
PLC
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
HUMAN
MACHINE (45 1.772) (45 1.772)
INTERFACES
FA
COMPONENTS
D
MACHINE Model No. B L M N P
VISION SF4B-H□C(A-J05) SF4B-A□C(A-J05)
SYSTEMS
279 316.4 264.4
UV SF4B-H12C(A-J05) 10.984
220
8.661 —
12.457 10.409
— —
CURING
SYSTEMS
359 396.4 344.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 14.134
300
11.811 280
11.024
15.606 13.559
— —
Model No. H Q
SF4B-H□C(A-J05) 20 0.787 22.2 0.874
LASER
SF4B-□CA-J05 SF4B-□C Safety light curtain SENSORS
PLC
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
(45 1.772)
HUMAN
ø15.6
(45ø0.614
1.772) MACHINE
INTERFACES
ø15.6 ø0.614
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
D
Model No. M R S T U MACHINE
SF4B-H□C(A-J05) SF4B-A□C(A-J05) VISION
SYSTEMS
264.4 245.8 270.4
SF4B-H12C(A-J05) 220
8.661 —
10.409 9.677
— —
10.646
UV
CURING
SYSTEMS
344.4 325.8 350.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 300
11.811 280
11.024
13.559 12.827
— —
13.795
424.4 405.8 430.4
SF4B-H20C(A-J05) 380
14.961 —
16.709 17.748
— —
16.945
504.4 485.8 510.4
SF4B-H24C(A-J05) SF4B-A12C(A-J05) 460
18.110 440
17.323
19.858 19.126
— —
20.094 Selection
Guide
584.4 565.8 590.4 Safety Light
SF4B-H28C(A-J05) 540
21.260 —
23.008 22.276
— —
23.244 Curtains
Safety
664.4 645.8 670.4 Control Units
SF4B-H32C(A-J05) SF4B-A16C(A-J05) 620
24.409 600
23.622
26.157 25.425
— —
26.394 Safety
Components
744.4 725.8 750.4
SF4B-H36C(A-J05) 700
27.559 —
29.307 28.575
— —
29.543
824.4 805.8 382.9 830.4 SF4D
SF4B-H40C(A-J05) SF4B-A20C(A-J05) 780
30.709 760
29.921
32.457 31.724 15.075
—
32.693
SF4B/
984.4 965.8 462.9 990.4 SF4B-G
SF4B-H48C(A-J05) SF4B-A24C(A-J05) 940
37.008 920
36.220
38.756 38.024 18.224
—
38.992 SF4B-C
1,144.4 1,125.8 542.9 1,150.4
SF4B-H56C(A-J05) SF4B-A28C(A-J05) 1,100 43.307 1,080 42.520
45.055 44.323 21.374
—
45.291 SF4C
1,304.4 1,285.8 402.9 841.9 1,310.4 BSF4-AH80
SF4B-H64C(A-J05) SF4B-A32C(A-J05) 1,260 49.606 1,240 48.819
51.354 50.622 15.862 33.146 51.590
SF2B
1,464.4 1,445.8 455.9 948.9 1,470.4
SF4B-H72C(A-J05) SF4B-A36C(A-J05) 1,420 55.906 1,400 55.118
57.654 56.921 17.949 37.358 57.890 SF2C
1,624.4 1,605.8 508.9 1,055.9 1,630.4 Definition of
SF4B-H80C(A-J05) SF4B-A40C(A-J05) 1,580 62.205 1,560 61.417
63.953 63.220 20.035 41.571 64.189 Sensing Heights
1,784.4 1,765.8 561.9 1,162.9 1,790.4
SF4B-H88C(A-J05) SF4B-A44C(A-J05) 1,740 68.504 1,720 67.716
70.252 69.520 22.122 45.783 70.488
1,944.4 1,925.8 614.9 1,269.9 1,950.4
SF4B-H96C(A-J05) SF4B-A48C(A-J05) 1,900 74.803 1,880 74.016
76.551 75.819 24.209 49.996 76.787
Model No. H Q
SF4B-H□C(A-J05) 20 0.787 22.2 0.874
・
FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・
LASER
SENSORS SF4B-□CA-J05 SF4B-□C Safety light curtain
PHOTO-
ELECTRIC Assembly dimensions
SENSORS
MICRO The figure depicts side mounting using the side mounting bracket MS-SF4BC-6 (optional) and the intermediate supporting bracket for side
PHOTO-
ELECTRIC mounting bracket MS-SF4BC-7 (optional).
SENSORS
(24 0.945) MS-SF4BC-6 (24 0.945)
AREA
SENSORS MS-SF4BC-3
FA
COMPONENTS
D
MACHINE Model No. B M N P V
VISION SF4B-H□C(A-J05) SF4B-A□C(A-J05)
SYSTEMS
279 264.4 308.4
UV SF4B-H12C(A-J05) 10.984
220
8.661 —
10.409
— —
12.142
CURING
SYSTEMS
359 344.4 388.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 14.134
300
11.811 280
11.024
13.559
— —
15.291
439 424.4 468.4
SF4B-H20C(A-J05) 17.283
380
14.961 —
16.709
— —
18.441
519 504.4 548.4
Selection SF4B-H24C(A-J05) SF4B-A12C(A-J05) 20.433
460
18.110 440
17.323
19.858
— —
21.591
Guide
Safety Light 599 584.4 628.4
Curtains SF4B-H28C(A-J05) 23.583
540
21.260 —
23.008
— —
24.740
Safety
Control Units 679 664.4 708.4
SF4B-H32C(A-J05) SF4B-A16C(A-J05) 26.732
620
24.409 600
23.622
26.157
— —
27.890
Safety
Components
759 744.4 788.4
SF4B-H36C(A-J05) 29.882
700
27.559 —
29.307
— —
31.039
839 824.4 399.5 868.4
SF4D SF4B-H40C(A-J05) SF4B-A20C(A-J05) 33.031
780
30.709 760
29.921
32.457 15.728
—
34.189
SF4B/
SF4B-G 999 984.4 479.5 1,028.4
SF4B-H48C(A-J05) SF4B-A24C(A-J05) 39.331
940
37.008 920
36.220
38.756 18.878
—
40.488
SF4B-C
1,159 1,144.4 559.5 1,188.4
SF4C SF4B-H56C(A-J05) SF4B-A28C(A-J05) 45.630
1,100 43.307 1,080 42.520
45.055 22.028
—
46.787
BSF4-AH80 1,319 1,304.4 419.5 858.5 1,348.4
SF4B-H64C(A-J05) SF4B-A32C(A-J05) 51.929
1,260 49.606 1,240 48.819
51.354 16.516 33.799 53.087
SF2B
1,479 1,464.4 472.5 965.5 1,508.4
SF4B-H72C(A-J05) SF4B-A36C(A-J05) 58.228
1,420 55.906 1,400 55.118
57.654 18.602 38.012 59.386
SF2C
Definition of 1,639 1,624.4 525.5 1,072.5 1,668.4
Sensing Heights
SF4B-H80C(A-J05) SF4B-A40C(A-J05) 64.528
1,580 62.205 1,560 61.417
63.953 20.689 42.224 65.685
1,799 1,784.4 578.5 1,179.5 1,828.4
SF4B-H88C(A-J05) SF4B-A44C(A-J05) 70.827
1,740 68.504 1,720 67.716
70.252 22.776 46.437 71.984
1,959 1,944.4 631.5 1,286.5 1,988.4
SF4B-H96C(A-J05) SF4B-A48C(A-J05) 77.126
1,900 74.803 1,880 74.016
76.551 24.862 50.650 78.283
Model No. H Q
SF4B-H□C(A-J05) 20 0.787 22.2 0.874
LASER
SF4B-□CA-J05 SF4B-□C Safety light curtain SENSORS
PLC
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
HUMAN
(45 1.772) MACHINE
INTERFACES
ø15.6 ø0.614
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
D
Model No. M R S T U MACHINE
SF4B-H□C(A-J05) SF4B-A□C(A-J05) VISION
SYSTEMS
264.4 245.8 270.4
SF4B-H12C(A-J05) 220
8.661 —
10.409 9.677
— —
10.646
UV
CURING
SYSTEMS
344.4 325.8 350.4
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 300
11.811 280
11.024
13.559 12.827
— —
13.795
424.4 405.8 430.4
SF4B-H20C(A-J05) 380
14.961 —
16.709 17.748
— —
16.945
504.4 485.8 510.4
SF4B-H24C(A-J05) SF4B-A12C(A-J05) 460
18.110 440
17.323
19.858 19.126
— —
20.094 Selection
Guide
584.4 565.8 590.4 Safety Light
SF4B-H28C(A-J05) 540
21.260 —
23.008 22.276
— —
23.244 Curtains
Safety
664.4 645.8 670.4 Control Units
SF4B-H32C(A-J05) SF4B-A16C(A-J05) 620
24.409 600
23.622
26.157 25.425
— —
26.394 Safety
Components
744.4 725.8 750.4
SF4B-H36C(A-J05) 700
27.559 —
29.307 28.575
— —
29.543
824.4 805.8 382.9 830.4 SF4D
SF4B-H40C(A-J05) SF4B-A20C(A-J05) 780
30.709 760
29.921
32.457 31.724 15.075
—
32.693
SF4B/
984.4 965.8 462.9 990.4 SF4B-G
SF4B-H48C(A-J05) SF4B-A24C(A-J05) 940
37.008 920
36.220
38.756 38.024 18.224
—
38.992 SF4B-C
1,144.4 1,125.8 542.9 1,150.4
SF4B-H56C(A-J05) SF4B-A28C(A-J05) 1,100 43.307 1,080 42.520
45.055 44.323 21.374
—
45.291 SF4C
1,304.4 1,285.8 402.9 841.9 1,310.4 BSF4-AH80
SF4B-H64C(A-J05) SF4B-A32C(A-J05) 1,260 49.606 1,240 48.819
51.354 50.622 15.862 33.146 51.590
SF2B
1,464.4 1,445.8 455.9 948.9 1,470.4
SF4B-H72C(A-J05) SF4B-A36C(A-J05) 1,420 55.906 1,400 55.118
57.654 56.921 17.949 37.358 57.890 SF2C
1,624.4 1,605.8 508.9 1,055.9 1,630.4 Definition of
SF4B-H80C(A-J05) SF4B-A40C(A-J05) 1,580 62.205 1,560 61.417
63.953 63.220 20.035 41.571 64.189 Sensing Heights
1,784.4 1,765.8 561.9 1,162.9 1,790.4
SF4B-H88C(A-J05) SF4B-A44C(A-J05) 1,740 68.504 1,720 67.716
70.252 69.520 22.122 45.783 70.488
1,944.4 1,925.8 614.9 1,269.9 1,950.4
SF4B-H96C(A-J05) SF4B-A48C(A-J05) 1,900 74.803 1,880 74.016
76.551 75.819 24.209 49.996 76.787
Model No. H Q
SF4B-H□C(A-J05) 20 0.787 22.2 0.874
・
FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・
LASER
SENSORS SF4B-□CA-J05 SF4B-□C Safety light curtain
PHOTO-
ELECTRIC Assembly dimensions
SENSORS ・
MICRO The figure depicts mounting using the metal protection case MS-SF4BCH-□ (optional) and the standard mounting bracket (optional).
PHOTO- 11.8 0.465 2 0.079 10 0.394 11.7 0.461 11.7 0.461 10 0.394 2 0.079 11.8 0.465
ELECTRIC
SENSORS
11.8 0.465 2 0.079 10 0.394 11.7 0.461 11.7 0.461 10 0.394 2 0.079 11.8 0.465
AREA 5.4 5.4 5.4
5.4 0.213
SENSORS 0.213 0.213 0.213
MS-SF4BC-1
5.4 5.4 5.4
SAFETY LIGHT 5.4 0.213
CURTAINS / 0.213 0.213 0.213
MS-SF4BC-1
SAFETY
COMPONENTS
PRESSURE /
FLOW Protective
SENSORS height
Protective
INDUCTIVE height
PROXIMITY 120 120
SENSORS D 4.724 C B A B B A B C 4.724 D
PARTICULAR 120 120
USE D 4.724 C B108A B B A B C 4.724
MS-SF4BCH-□ D 108
SENSORS 4.252 4.252
108 MS-SF4BCH-□ 108
SENSOR 4.252 4.252
OPTIONS
SIMPLE
WIRE-SAVING 46.6 H Beam pitch H 46.6
UNITS 1.835 1.835
H G Beam pitch H 46.6 G
46.6
WIRE-SAVING 1.835
SYSTEMS 1.835
G G
MEASURE-
ø5 ø0.197 Gray cable ø5 ø0.197
MENT 12.8 16.7 16.7 Gray cable (12.8 0.504)
SENSORS 0.504
ø5 ø0.197 Gray cable 0.657 ø5 ø0.1970.657 (with black line)
24 31 31 24
12.8 16.7 16.7
1.220 Gray cable 1.220 (12.8 0.504)
STATIC 0.945 0.945
CONTROL 0.504 25.6311.008 0.657 0.657 32 1.260 (with black line) 32 1.260 25.6 1.008
24 31 24
DEVICES 1.220 1.220
0.945 0.945
25.6 1.008 32 1.260 32 1.260 25.6 1.008
LASER
MARKERS
Emitter Receiver
PLC
Note: In the case of using a metal protection case MS-SF4BCH-□ (optional), make sure to assemble it with a standard mounting bracket MS-SF4BC-1 (optional).
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
<Connector of the pigtailed type (with muting function) SF4B-□CA-J05>
(45 1.772)
FA
COMPONENTS
(45 1.772) ø15.6 ø0.614
MACHINE
VISION ø15.6 ø0.614
SYSTEMS
UV
CURING
SYSTEMS D
Model No. A B C
SF4B-H□C(A-J05) SF4B-A□C(A-J05)
SF4B-H12C(A-J05) 294.4 11.591 279 10.984 263.4 10.370 220 8.661 —
SF4B-H16C(A-J05) SF4B-A8C(A-J05) 374.4 14.740 359 14.134 343.4 13.520 300 11.811 280
11.024
Selection
Guide
SF4B-H20C(A-J05) 454.4 17.890 439 17.283 423.4 16.669 380
14.961 —
Safety Light
Curtains
Safety
SF4B-H24C(A-J05) SF4B-A12C(A-J05) 534.4 21.039 519 20.433 503.4 19.819 460
18.110 440
17.323
Control Units
Safety
SF4B-H28C(A-J05) 614.4 24.189 599 23.583 583.4 22.969 540
21.260 —
Components
SF4B-H32C(A-J05) SF4B-A16C(A-J05) 694.4 27.339 679 26.732 663.4 26.118 620
24.409 600
25.984
SF4C SF4B-H56C(A-J05) SF4B-A28C(A-J05) 1,174.4 46.236 1,159 45.630 1,143.4 45.016 1,100 43.307 1,080 42.520
BSF4-AH80 SF4B-H64C(A-J05) SF4B-A32C(A-J05) 1,334.4 52.534 1,319 51.929 1,303.4 51.315 1,260 49.606 1,240 48.819
SF2B SF4B-H72C(A-J05) SF4B-A36C(A-J05) 1,494.4 58.835 1,479 58.228 1,463.4 57.614 1,420 55.906 1,400 55.118
SF2C SF4B-H80C(A-J05) SF4B-A40C(A-J05) 1,654.4 65.134 1,639 64.528 1,623.4 63.913 1,580 62.205 1,560 61.417
Definition of
Sensing Heights SF4B-H88C(A-J05) SF4B-A44C(A-J05) 1,814.4 71.433 1,799 70.827 1,783.4 70.213 1,740 68.504 1,720 67.717
SF4B-H96C(A-J05) SF4B-A48C(A-J05) 1,974.4 77.732 1,959 77.126 1,943.4 76.512 1,900 74.803 1,880 74.016
Model No. G H
SF4B-H□C(A-J05) 21.7 0.854 20 0.787
LASER
MS-SF4BC-1 Standard mounting bracket (optional) SENSORS
AREA
SENSORS
10.8 2 0.079 2 0.079 10.8
0.425 0.425 SAFETY LIGHT
2 × M3 mounting hole CURTAINS /
(for main body mounting) 9.3 9.3 SAFETY
0.366 0.366 COMPONENTS
45° ° 45
45° 5.4 0.213 5.4 0.213 45 ° PRESSURE /
FLOW
R7.2 R0.283 R7.2 R0.283 SENSORS
2 × M3 mounting hole
(for main body mounting) INDUCTIVE
29.4 10 0.394 10 0.394 29.4 PROXIMITY
1.157 1.157 SENSORS
15.7 15.7 PARTICULAR
11.5 0.618 0.618 11.5 USE
6.5 0.453 10.7 0.421 10.7 0.421 0.453 6.5 SENSORS
0.256 0.256
5 5 SENSOR
0.197 Material: Stainless steel (SUS) 0.197 OPTIONS
11.8 Four brackets (two each R and L type) per set 11.8
0.465 Eight M3 (length: 5 mm 0.197 in) hexagon-socket head 0.465 SIMPLE
21.6 0.850 21.6 0.850 WIRE-SAVING
bolts and four M5 flat washers are attached. UNITS
WIRE-SAVING
SYSTEMS
HUMAN
8 12 12 8 MACHINE
INTERFACES
0.315 0.472 2 × M3 mounting hole 0.472 0.315
R7.2 R0.283 (for main body mounting) R7.2 R0.283 ENERGY
7° 7° (Note) 10 10 7° 7° (Note) MANAGEMENT
0.394 0.394 SOLUTIONS
FA
COMPONENTS
20.4 20.4
36.4 0.803 0.803 36.4 2 × M3 mounting hole MACHINE
1.433 1.433 (for main body mounting) VISION
SYSTEMS
22.7 22.7
17 0.894 0.894 17 UV
0.669 0.669 CURING
11 11 SYSTEMS
0.433 0.433
5.5 5.5
0.217 4 4 0.217
0.157 Material: Stainless steel (SUS) 0.157
14 14
0.551 Four brackets (two each R and L type) per set 0.551
23.8 Note: The adjustment range of the safety Eight M3 (length: 6 mm 0.236 in) hexagon-socket head 23.8 Selection
0.937 light curtain angle is up to ±7 degrees. bolts and four M5 flat washers are attached. 0.937 Guide
Safety Light
Curtains
Safety
Control Units
MS-SF4BC-3 Side utility mounting bracket (optional) Safety
Components
t 2 t 0.079 t 2 t 0.079
SF4D
SF4B/
SF4B-G
28 28
1.102 1.102 SF4B-C
SF4C
BSF4-AH80
32.5 1.280 32.5 1.280
SF2B
2 × M3 mounting hole 2 × M3 mounting hole SF2C
(for main body mounting) 9.3 9.3 R7.2
R7.2 0.366 0.366 (for main body mounting)
R0.283 7° 7° (Note) 7° 7° (Note) R0.283 Definition of
5.4 0.213 5.4 0.213 Sensing Heights
8.7 0.343 8.7 0.343
13.7 13.7
0.539 19.4 28.7 0.539
0.764 1.130 10 19.4
10 0.764
0.394 0.394
28.7
1.130
・
FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・
LASER
SENSORS MS-SF4BC-4 Intermediate supporting bracket for utility mounting bracket (optional)
PHOTO-
ELECTRIC <For rear mounting> <For side mounting>
SENSORS
MICRO 30.6 1.205 0.5 0.020 30 1.181
PHOTO- 20.6 0.811
ELECTRIC 20 0.787
SENSORS 6 5.4 0.213
0.236
AREA
SENSORS
33.5
SAFETY LIGHT 1.319
CURTAINS /
26
5.4 0.213 1.024
SAFETY 38.5
COMPONENTS 1.516 18.5
26 0.728
PRESSURE / 1.024 13.5
FLOW
18.5 0.531 11
SENSORS 0.433
0.728
INDUCTIVE 13.5 4
PROXIMITY 0.531 11 0.157
SENSORS 0.433 10.5
0.413
PARTICULAR
1 0.039 20.5 0.807
USE
SENSORS 27.5 1.083
24.6
0.969
33
1.299
Selection
Guide
Safety Light
Curtains 30.4 1.197
Safety 22.4 0.882
Control Units 22.8 0.898
Safety 18.7 0.736
Components 14.8
0.583 13.7
0.539
9.8 2 × M3 mounting hole for countersunk screw 13.4
0.386 0.528 6 × M3 mounting hole for countersunk screw
SF4D 8.7
0.343
SF4B/
SF4B-G
30
SF4B-C
20 1.181
0.787
SF4C
BSF4-AH80
5 0.197
20
SF2B 0.787
40 20 60
SF2C 1.575 0.787 2.362
Definition of
Sensing Heights
25
0.984
15
0.591
LASER
MS-SF4BC-6 Side mounting bracket (optional) SENSORS
PHOTO-
t 2 t 0.079 t 2 t 0.079 ELECTRIC
SENSORS
MICRO
PHOTO-
24 24 ELECTRIC
0.945 0.945 SENSORS
AREA
SENSORS
22.3 0.878 3
22.3 0.878 SAFETY LIGHT
(26 1.024) (26 1.024) CURTAINS /
M3 mounting hole M3 mounting hole SAFETY
(for main body (for main body COMPONENTS
R7.2 R7.2
9 mounting) (Note) R0.283 R0.283 (Note) mounting) 9 PRESSURE /
0.354 0.354 FLOW
7° 7° 7° 7° SENSORS
10 13.7 13.7 10
0.394 0.394 INDUCTIVE
20 0.539 0.539 20 PROXIMITY
19.4 19.4 SENSORS
0.787 0.764 0.764 0.787
45.4 25.4 25.4 45.4 PARTICULAR
46.4 1.787 1.000 1.000 1.787 46.4 USE
1.827 4 4 1.827 SENSORS
0.157 0.157
66.4 66.4 SENSOR
2.614 2.614 OPTIONS
20 20
0.78715 15 0.787
0.591 32 32 0.591 SIMPLE
1.260 1.260 WIRE-SAVING
10 10 UNITS
0.394 0.394
WIRE-SAVING
SYSTEMS
Note: The adjustment range of the safety light curtain angle is up to ±7 degrees. PLC
HUMAN
MACHINE
INTERFACES
MS-SF4BC-7 Intermediate supporting bracket for side mounting bracket (optional) ENERGY
MANAGEMENT
SOLUTIONS
31.5 1.240
FA
(28.5 1.122) COMPONENTS
MACHINE
t 1.5 t 0.059 VISION
SYSTEMS
32.2
t2 20.2 1.268
12.5 0.795 UV
0.492 t 0.079 20.6 CURING
0.811 SYSTEMS
8.1 9 0.354
0.319
15.5
0.610 3.6 0.142
・
FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・
LASER
SENSORS MS-SF4BCH-□ Metal protection case (optional)
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
W
AREA W
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
% & ' % $
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Material: Stainless steel (SUS304)
PLC
HUMAN
MACHINE
INTERFACES
Model No. A B C D
ENERGY MS-SF4BCH-12 294.4 11.591 279 10.984 264.4 10.409 140.4 5.528
MANAGEMENT
SOLUTIONS
MS-SF4BCH-16 374.4 14.740 359 14.134 344.4 13.559 220.4 8.677
FA
COMPONENTS MS-SF4BCH-20 454.4 17.890 439 17.283 424.4 16.709 300.4 11.827
MACHINE MS-SF4BCH-24 534.4 21.039 519 20.433 504.4 19.858 380.4 14.976
VISION
SYSTEMS
MS-SF4BCH-28 614.4 24.189 599 23.583 584.4 23.008 460.4 18.126
UV
CURING MS-SF4BCH-32 694.4 27.339 679 26.732 664.4 26.157 540.4 21.276
SYSTEMS
MS-SF4BCH-36 774.4 30.488 759 29.882 744.4 29.307 620.4 24.425
SF4C
BSF4-AH80
SF2B
SF2C
Definition of
Sensing Heights
SF4B-C SERIES
Compact Safety Light Curtain Type 4
576
・
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website.・ FIBER
SENSORS
LASER
SFB-CC□-MU Mating cable with connector on one end (optional) SFB-CCJ□-MU Mating cable with connectors on both ends (optional) SENSORS
PHOTO-
(1.772
45
) L (1.772
45
) L (1.772
45
) ELECTRIC
SENSORS
MICRO
PHOTO-
ø15.6 ø15.6 ø15.6 ELECTRIC
ø0.614 ø0.614 ø0.614 SENSORS
ø6 ø6 AREA
ø0.236 ø0.236 SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
SF-C13 Control unit (optional) SFB-HC Handy-controller (optional) UNITS
WIRE-SAVING
SYSTEMS
65 2.559
30 MEASURE-
6.75 1.181 MENT
0.266 6 0.236 SENSORS
4 0.157 5 0.197 25.4 STATIC
1.000 CONTROL
35 34.5 30.118
× 5 = 15
× 0.197 = 0.591 23 ø6 ø0.236 cables, DEVICES
1.378 1.358 0.906 0.5 m 1.640 ft long
67.3 LASER
2.650 MARKERS
130
5.118 91.6 PLC
3.606
HUMAN
MACHINE
INTERFACES
140
10 5.512 ENERGY
0.394 80 3.150 13 0.512 5 0.197 MANAGEMENT
6.5 SOLUTIONS
13.5 0.256 80.8 3.181 22.5
0.531 0.886 FA
Suitable for 35 mm 1.378 in width DIN rail COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Safety Light
Curtains
Safety
Control Units
Safety
Components
SF4D
SF4B/
SF4B-G
SF4B-C
SF4C
BSF4-AH80
SF2B
SF2C
Definition of
Sensing Heights