Flowserve Flowpro V724
Flowserve Flowpro V724
Product features
Body shape for optimum
flow characteristics Contoured
Plug
Disk
Plug
Perfo-
rated
Contou-
red Plug,
Perfo-
rated
Piston
Plug with
RLS
two-step
RLS
two-step
RLS
three-step
Mixing
Plug
Contoured
Plug
Plug top and Plug, contou- Series 1 Series 2 Series 2
bottom top and red seat Distributing
guided bottom Plug
• favourable flow dynamics when cor- guided
rectly selected
• solid top or top and bottom guided
plug
Covers
2
flowserve.com
FlowPro - High Performance Valve
TM
100
Disk Perfo- Contou- Perfo- RLS RLS RLS Contoured Disk Perfo- Contou- Perfo- Piston RLS RLS RLS Mixing
Plug rated red Plug, rated two-step two-step three-step Plug Plug rated red Plug, rated Plug with two-step two-step three-step Plug
Plug top and Plug, Series 1 Series 2 Series 2 Plug top and Plug, contou- Series 1 Series 2 Series 2
bottom top and bottom top and red seat Distributing
guided bottom guided bottom Plug
guided guided
HER
SC
3
Body with Flange Connection
Certificate Nominal Size DN
Body Material
without with 25 40 50 80 100 150 200 250 300
1.0619
1.4581 Material certificate Material certificate acc. to
4
flowserve.com
FlowTop - High Performance Valve TM
Body Material W.Nr.: 1.5419, G 20 Mo 5 Body Material W.Nr.: 1.7357, G 17 CrMo 5-5
PN safe load operating pressure in bar at °C PN safe load operating pressure in bar at °C
(bar) -100 -60 -10 50 100 200 250 300 350 400 450 500 530 (bar) -100 -60 -10 50 100 200 250 300 350 400 450 500 530
63 63 63 63 60,2 56,0 47,6 44,8 42,0 40,6 63 63 63 63 63 61,6 57,4 53,2 50,4 47,6 38,4 21,8
100 100 100 100 95,6 88,9 75,6 71,1 66,7 64,4 100 100 100 100 100 97,8 91,1 84,4 80,0 75,6 60,9 34,7
160 160 160 160 135,0 126,0 117,0 110,0 107,0 103,0 160 160 160 160 160 156,0 146,0 135,0 128,0 121,0 97,0 56,0
Body Material W.Nr.: 1.6220, G 20 Mn 5 Body Material W.Nr.: 1.4308, GX 5 CrNi 19-10
PN safe load operating pressure in bar at °C PN safe load operating pressure in bar at °C
(bar) -200 -100 -60 -10 50 100 200 250 300 350 400 450 500 (bar) -200 -100 -60 -10 50 100 200 250 300 350 400 450 500
63 47,3 63 63 42,0 37,8 36,8 35,7 63 63 63 63 63 49,0 43,4 35,6 33,0 30,8
100 75,0 100 100 66,7 60,0 58,3 56,7 100 100 100 100 100 77,8 68,9 56,4 52,4 48,9
160 120,0 160 160 106,7 96,0 93,3 90,7 160 160 160 160 160 128,0 114,0 89,0 84,0 78,0
Bonnet 1) pressure balancing not possible by three-way valves, Silentpack, MultiStream, Disk Plug and Disk Plug with Contoured Seat !
-Bonnet
Standard- Bellows seal- HT Extension- LT Extension- Insulating- Heavy duty-
Use: Use: Use: Use: Use: Use:
Nominal general toxic, smell strong, in case of possible for reducing the for reducing the by rotary electric
Pressure Balancing Body Material Size fleeting, costly me- overhating of pack- danger of icing of danger of icing of actuators and linear
dia or vacuum ing and/or linear ac- the packing box the packing box thrust units
tuator
-10 °C to +250 °C -60 °C to +400 °C >250 °C to +450 °C -60 °C to +250 °C -200 °C to +250 °C -10 °C to +530 °C
Unbalanced, 1.0619
shaft guided
1.4581
25
1.5419
to
1.7357
300
1.6220
1.4308
V-Ring balanced 1), 1.0619
suitable for 80
Trim Material 1.4571 1.4581
to
-60 °C up to +250 °C 1.5419
300
1.6220
Piston-Ring balanced 1), 1.0619 50
s. f. Trim Material 1.4122 to
+250 °C up to +450 °C 1.5419 300
Packing Box
-Bonnet
Type of Packing
Standard- Bellows seal- HT Extension- LT Extension- Insulating- Heavy duty-
standard
Pure Grafite-Rings
loaded
Plug
Design Guide of Plug Flow
Plug Type Characteristic Top guided Top and bot-
tom guided Flow Action Flow Action
Seat 4 - 250 tends to tends to
(only Four-Flange)
standard partial full hardened tenifer open valve close valve
stellited stellited treated Seat 34 - 250
5
Parabolic Plug
Characteristic: modified-equal percentage
Material / Design
Kvs Port Guide Stroke Incorporable seat diameter depends on nominal size DN
of 1.4571 1.4122 1.4922
Size Plug (mm)
(m3/h)
stan- partial full soft stan- harde- stan-
dard stellited stellited seated dard ned dard 25 40 50 80 100 150 200 250 300
0,16 4 1
0,25 4 1
0,40 4 1
0,63 6 1
1,6 8 1
2,5 10 1
20
4,0 12 1
6,3 16 1
10 20 1
16 25 1
25 34 1/2*
40 42 1/2
40 42 1/2
63 53 1/2
40
100 67 1/2
160 84 1/2
160 84 1/2
200 100 1/2
355 125 1/2
80
450 150 1/2
710 200 1/2
1000 250 1/2
Parabolic Plug
Characteristic: linear
Material / Design
Kvs Port Guide Stroke Incorporable seat diameter depends on nominal size DN
of 1.4571 1.4122 1.4922
(m3/h) Size
Plug (mm) stan- partial full soft stan- harde- stan-
dard stellited stellited seated dard ned dard 25 40 50 80 100 150 200 250 300
4,0 12 1
6,3 16 1
10 20 1
20
16 25 1
25 34 1/2*
40 42 1/2
40 42 1/2
63 53 1/2
40
100 67 1/2
160 84 1/2
160 84 1/2
200 100 1/2
355 125 1/2
80
450 150 1/2
710 200 1/2
1000 250 1/2
* 1 Top guided
2 Top and bottom guided with four-flange body only
6
flowserve.com
FlowPro TM
- High Performance Valve
Perforated Plug
Characteristic: equal percentage
Material / Design
Kvs Port Guide Stroke Incorporable seat diameter depends on nominal size DN
of 1.4571 1.4122 1.4922
(m3/h) Size Plug (mm)
tenifer stan- harde- stan- harde-
treated dard ned dard ned 25 40 50 80 100 150 200 250 300
2,5 20 1
4,0 20 1
6,3 20 1
20
10 25 1
20 34 1
25 42 1
28 42 1
50 53 1/2
40
71 67 1/2
100 84 1/2
160 84 1/2
200 100 1/2
280 125 1/2
80
400 150 1/2
500 200 1/2
710 250 1/2
Perforated Plug
Characteristic: linear
Material / Design
Kvs Port Guide Stroke Incorporable seat diameter depends on nominal size DN
of 1.4571 1.4122 1.4922
(m /h)
3
Size Plug (mm)
tenifer stan- harde- stan- harde-
treated dard ned dard ned 25 40 50 80 100 150 200 250 300
2,5 20 1
4,0 20 1
6,3 20 1
20
10 25 1
20 34 1
25 42 1
28 42 1
50 53 1/2
40
90 67 1/2
125 84 1/2
160 84 1/2
200 100 1/2
315 125 1/2
80
500 150 1/2
630 200 1/2
900 250 1/2
7
Disk Plug
Characteristic: on / off
Material / Design
Kvs Port Guide Stroke Incorporable seat diameter depends on nominal size DN
of 1.4571 1.4122 1.4922
(m3/h) Size Plug (mm)
standard standard standard 25 40 50 80 100 150 200 250 300
10 20 1
25 34 1 20
40 42 1
100 67 1
40
160 84 1
400 125 1
500 150 1
80
1000 200 1
1400 250 1
Material / Design
Kvs Port Guide Stroke Incorporable seat diameter depends on nominal size DN
of 1.4571 1.4122
(m3/h) Size Plug (mm)
full stellited hardened 25 40 50 80 100 150 200 250 300
2,5 16 1
6,3 20 1
10 25 1 20
16 34 1
25 42 1
40 53 1
63 67 1 40
100 84 1
160 100 1
200 125 1 80
355 150 1
Material / Design
Kvs Port Guide Stroke Incorporable seat diameter depends on nominal size DN
of 1.4571 1.4122
(m /h)
3
Size Plug (mm)
tenifer
treated standard hardened 40 50 80 100 150 200
25 34 2
20
40 42 2
100 67 2
40
160 84 2
355 125 2
80
450 150 2
8
flowserve.com
FlowPro TM
- High Performance Valve
3.6
1.4
Bonnet Gasket 1.2 Pure Graphite on Support Plate from 1.4571
Stud Bolt 1.3 G GA V
3.2
Hex Nut 1.4 G GA V
1.5 Extension Sleeve 1.5 G GA V
Screwed Seat 2.1 1.4571/1.4122 1.4922 1.4571
3.5
Contoured Plug 2.2 1.4571/1.4122 1.4922 1.4571
3.1 Spring Pin 2.3 A2
Stem 2.4 1.4571 1.4922 1.4571
Profil Ring 2.5 Pure Grafite
Bonnet 3.1 1.0460 1.5415 1.7335 1.4571
1.2 Bottom Ring 3.2 1.4571
Packing Box 3.3 PTFE-Rings or Pure Grafite Rings
Gland Flange 3.4 1.0460 1.5415 1.4571
2.4 Stud Bolt 3.5 A 2 - 70
Hex Nut 3.6 A 2 - 70
Insert 4.1 1.0460 1.5415 1.7335 1.4571
2.2
2.1
2.5
1.3
1.1
1.3
1.2
4.1
1.5
1.4
9
Single Seat Valve suitable for linear
Thrust Units and electrical rotary Actuators
5.10 + 5.11
5.9
5.7
5.8
Designation Part Materials
3.6
Body 1.1 1.0619 1.5419 1.7357 1.4581
3.4
Bonnet Gasket 1.2 Pure Graphite on Support Plate from 1.4571
3.3 Stud Bolt 1.3 G GA V
Hex Nut 1.4 G GA V
3.2 5.2
Extension Sleeve 1.5 G GA V
5.3 Screwed Seat 2.1 1.4122 1.4122 1.4922 1.4571
5.1 5.5 + 5.6 Contoured Plug 2.2 1.4122 1.4122 1.4922 1.4571
100
2.5
Special Materials on request !
1.3
1.1
1.3
1.2
4.1
10
flowserve.com
FlowPro TM
- High Performance Valve
≈H 5
≈H 3
≈H 2
≈H 1
≈H 1
DN 100 DN 100
PN 160 PN 160 DN 100 DN 100 DN 100
PN 160 PN 160 PN 160
≈h
BL
Nominal Size DN
Designations
25 40 50 80 100 150 200 250 300
Stroke 20 40 80
BL Face to Face Dimensions 230 260 300 380 430 550 650 775 900
≈h 120 135 165 195 240 315 405 480 535
≈ H1 Standard Bonnet 160 195 215 220 255 330 410 485 535
≈ H2 Extension Bonnet 160 195 215 390 425 505 580 655 705
≈ H3 Bellows seal Bonnet 325 360 360 550 550 905 905 905 905
≈ H5 Insulating Bonnet 650 650 650 650 650 670 800 800 800
≈ Weight in kg Standard Bonnet 19,5 30 44 84 133
Three-Flange Body
Extension Bonnet 19,5 30 44 86 136
Bellows seal Bonnet 26,0 38 50 98 144
Insulating Bonnet 26,0 38 50 98 144
≈ Weight in kg Standard Bonnet 23,5 34 48 91 161 320 600 981 1333
Four-Flange Body
Extension Bonnet 23,5 34 48 93 164 323 603 984 1336
Bellows seal Bonnet 30,0 42 55 105 172 340 620 1001 1353
Insulating Bonnet 30,0 42 55 105 172 340 620 1001 1353
Flanges Drilled and Dimensioned acc. to EN 1092-1, Form B2, Form F, Form D resp. DIN 2501, Form E, R, N, L
Welded Ends comply with DIN 3239 Section 1, Table 1
100 100
0 0
≈H
≈H
DN 100 DN 100
PN 160 PN 160
≈h
BL
Valve with BL
Standard Bonnet
Valve with
Standard Bonnet
Nominal Size DN
Designations
25 40 50 80 100 150 200 250 300
Stroke 20 40 80
BL Face to Face Dimensions 230 260 300 380 430 550 650 775 900
≈h 120 135 165 195 240 315 405 480 535
≈H Standard Bonnet (heavy duty) 332 371 388 560 510 813 895 925 980
≈ Weight in kg - Three-Flange Body 30 40 54 105 169
≈ Weight in kg - Four-Flange Body 34 44 59 112 197 405 688 1077 1432
Flanges Drilled and Dimensioned acc. to EN 1092-1, Form B2, Form F, Form D resp. DIN 2501, Form E, R, N, L
Welded Ends comply with DIN 3239 Section 1, Table1
11
Valve with Angle Body
≈H 4
≈H 3
≈H 2
≈H 1
Nominal Size DN
Designations
25 40 50 80 100 150 200
Stroke 20 40 80
E Angle Dimension 115 130 150 190 215 275 325
≈H1 Standard Bonnet 140 165 180 180 200 250 300
≈H2 Extension Bonnet 140 165 180 350 370 420 470
≈H3 Bellows seal Bonnet 305 340 340 510 510 820 820
≈H3 Insulating Bonnet 630 630 630 630 630 630 690
≈ Weight in kg Standard Bonnet 15 27 38 65 92 215 375
Extension Bonnet 15 27 38 67 95 218 378
Bellows seal Bonnet 22 34 43 79 103 235 380
Insulating Bonnet 22 34 43 79 103 235 380
Flanges Drilled and Dimensioned acc. to EN 1092-1, Form B2, Form F, Form D resp. DIN 2501, Form E, R, N, L
Welded Ends comply with DIN 3239 Section 1, Table 1
100
0
≈H
DN 100
PN 160
E
Valve with
Standard Bonnet
Nominal Size DN
Designations
25 40 50 80 100 150 200
Stroke 20 40 80
E Angle Dimension 115 130 150 190 215 275 325
≈H Standard Bonnet (heavy duty) 311 342 353 519 455 430 785
≈ Weight in kg 26 36 47 86 128 300 463
Flanges Drilled and Dimensioned acc. to EN 1092-1, Form B2, Form F, Form D resp. DIN 2501, Form E, R, N, L
Welded Ends comply with DIN 3239 Section 1, Table 1
12
flowserve.com
FlowPro TM
- High Performance Valve
Three-Way Valve
≈H 5
≈H 3
≈H 2
≈H 1
BL
Nominal Size DN
Designations
40 50 80 100 150 200
Stroke 20 40 80
BL Face to Face Dimensions 260 300 380 430 550 650
≈h 240 250 310 350 450 550
≈ H1 Standard Bonnet 195 215 220 255 330 410
≈ H2 Extension Bonnet 195 215 390 425 505 580
≈ H3 Bellows seal Bonnet 360 360 550 550 905 905
≈ H5 Insulating Bonnet 650 650 650 650 670 800
≈ Weight in kg Standard Bonnet 40 56 105 176 348 654
Extension Bonnet 40 56 105 178 351 656
Bellows seal Bonnet 48 64 118 193 385 674
Insulating Bonnet 48 64 118 193 385 674
Flanges Drilled and Dimensioned acc. to EN 1092-1, Form B2, Form F, Form D resp. DIN 2501, Form E, R, N, L
Three-Way Valve
100
0
≈H
DN 100
PN 100
≈h
BL
Valve with
Standard Bonnet
Nominal Size DN
Designations
40 50 80 100 150 200
Stroke 20 40 80
BL Face to Face Dimensions 260 300 380 430 550 650
≈h 240 250 310 350 450 550
≈H Standard Bonnet (heavy duty) 371 388 560 510 813 895
≈ Weight in kg 50 67 126 212 433 742
Flanges Drilled and Dimensioned acc. to EN 1092-1, Form B2, Form F, Form D resp. DIN 2501, Form E, R, N, L
13
Pneumatic linear Actuator
with NAMUR-Yoke
øA
≈H PD 252 - PD 700
Designation Area 250 500 700
Stroke 20 mm 20 mm 40 mm 20 mm 40 mm
øA mm 265 352 352 405 405
≈H mm 330 420 450 545 545
≈ Weight kg 16 31 40 46 46
øA
≈H PD 3002
≈H PD 1502
14
flowserve.com
FlowPro TM
- High Performance Valve
≈H
Designation Actuator ED 1,2 ED 4,5 ED 8 ED 12 ED 20 ED 25
Stroke 20 mm 20/40 mm 20 / 40 / 80 mm 80 mm
øA mm 145 145 184 184 216 216
≈H mm 505 535 570 570 660 660
≈ Weight kg 6,5 7,5 13 13 19 19
Manual Operation øA
≈H
15
SPM - Code Typ
V724 DEVNA
DN
50
PN
160
Body/Cert.
1.0619/OOAO
Plug
PONP1GG
Seat kvs
42 40
Trim
1.4571
Actuator
Form of Connection
Port Size 4 - 250
Flange acc. to Form B2 M
EN 1092-1 Form D Q
Form F Y Flow tends top open Valve G
Flow tends to close Valve I
Flange acc. to Form E E
DIN 2526 Form N N
Form R R Characteristic
Form L L
modified - equal percentage G
Welded Ends acc. to linear L
DIN 3239 S on / off A
modified - equal percentage H
Bonnet Form with Special Rangeability
Bonnet Assembly
Seat Leakage
Standard Bonnet N
Bellows seal Bonnet F IEC Class III O
HT-Extension Bonnet R Class IV P
LT-Extension Bonnet K Class IV - S1 Q
Insulating Bonnet I Class IV - S2 R
Class V S
Class VI T
16
flowserve.com
FlowPro TM
- High Performance Valve
PD 252 ADYOZ Operation on air failure ED 8/8 ZPO 50 Positioning Speed LD 16 Linear thrust Unit “light”
Hand Wheel
17
18
flowserve.com
FlowPro TM
- High Performance Valve
19
Flowserve (Austria) GmbH
Control Valves - Villach Operation
Kasernengasse 6
9500 Villach
Austria
www.flowserve.com
www.flowserve-villach.com
SAEEBRV724-01 01.10
Your contact:
TM
indicates a trade mark of Flowserve.
Infomation given in this product specification sheet is made in good faith and based upon specific testing but does not, however, constitute a guarantee.
Modifications without notice in line with technical progress.
PSS 108292 05/07 V724 en