Smart-UPS

On-Line 230 V
Unity output power factor single-phase,
double-conversion online UPS
with advanced management features

apc.com
2 apc.com
apc.com 3

A versatile UPS developed


for unstable power
conditions worldwide

Smart-UPS On-Line provides high-density, double-conversion, online power protection for servers,
TM

voice/data networks, medical labs, and light industrial applications. The Smart-UPS On-Line is capable
of supporting loads from 1 kVA – 10 kVA in a rack/tower convertible chassis. The 6 kVA, 8 kVA, and 10 kVA
models feature unity output power factor enabling them to support power-hungry blade servers or heavily
loaded equipment racks. When business-critical systems require runtime in hours, not minutes, Smart-UPS
On-Line can be configured with multiple battery packs to meet aggressive runtime demands.

The included PowerChute Network Shutdown management software provides unattended graceful
TM

shutdown of network operating systems. Models 5 kVA to 10 kVA include an integrated network
management card for remote management. The entire Smart-UPS On-Line family provides value to
customers with demanding power conditions, including a very wide input voltage window, extremely tight
output voltage regulation, frequency regulation, internal bypass, and input power factor correction.
apc.com 4

Smart-UPS On-Line
Industry-leading power factor maximizing UPS density.
Rackmount and tower SRT 1 kVA – 10 kVA

Standard features
Best-in-class power density
More real power in watts, 0.9 pf on 2.2 kVA – 5 kVA,
Unity on 1-1.5 kVA unites and 6 kVA – 10 kVA units.

High-efficiency “green mode”


Achieves 98 percent efficiency, which saves
utility and cooling costs without compromising
performance or reliability.

Graphical LCD display with multicolor backlight


Intuitive interface provides detailed and accurate
information with ability to configure locally.

Intelligent battery management


Temperature-compensated charging extends life
and advanced algorithms recommend replacement
date. The UPS can inform user which batteries need
to be replaced and auto detect when additional
battery packs are added.

Built-in energy meter


Measures energy use and displays UPS
efficiency in various modes of operation for easy
energy tracking.

Operate without battery


Ability to immediately protect equipment when
power returns after a complete discharge of
the battery.

Three-year warranty on electronics


Additional year of warranty protection
for electronics provides peace of mind.

SRT6KXLI shown
5 apc.com
6 apc.com
apc.com 7

Smart-UPS On-Line
Proven performance with the world’s largest installed base
of single-phase, double-conversion products.
Rackmount and tower SRT 1 kVA – 10 kVA

Additional features
Embedded network management card with
environmental monitoring (5 kVA – 10 kVA models)
Remote monitoring and control of the UPS and
the environment via Ethernet connection while
freeing up the SmartSlot so customers can add
TM

accessories for additional communication options.

Switched outlet group(s)


Ability to control a group of output load receptacles
independent from the main UPS. Enables:

• Rebooting hung device without cycling


the entire UPS
• Sequenced turn ON/OFF
• Shedding of noncritical loads based on a variety
of parameters (battery time, runtime remaining,
and overload)
• Scheduled time OFF to conserve energy

Emergency power off


Remote UPS shutoff in the event of a fire or other
emergency. The UPS can accept normally open
(NO) or normally closed (NC) contacts.

Communication ports
Serial, USB, Ethernet, and SmartSlot for network
accessory cards.

Communication protocols
Modbus serial, USB PowerSummary, HTTP, SNMP,
and Telnet.

1:1, 3:1 input hard-wire options


Product can be wired for 3-PH or 1-PH input
(230 V, 8 kVA, and 10 kVA models only).

Dual input
Enables second input source to be connected to
UPS bypass (230 V, 8 kVA, and 10 kVA models only).

SRT6KXLI shown
apc.com 8

Smart-UPS On-Line display


Intuitive, easy-to-use LCD provides clear and accurate
information in multiple languages.

Standard features
LCD display screen
Accurately provides real-time status updates in
your choice of basic or advanced menus.

UPS status (scrolling)

• Output voltage
• Input voltage
• Output frequency
• Runtime
• Load
• Battery health

Control

• UPS and outlet group settings


• Bypass control

Configuration

• Output voltage, frequency


• Language, brightness, contrast
• Alarm volume
• IP address

Test and diagnostics

• Initiate battery and runtime calibration tests

About

• UPS serial number, battery part number


• Battery install and suggested replacement dates

Backlit screens:
Amber: Indication of condition that Red: Indication of UPS alarm that
requires attention requires immediate attention
apc.com 9

Product accessories
Management cards Backplate kit
• AP9640: UPS Network Management Card • SRT001: APC Smart-UPS SRT 5 kVA output HW kit
• AP9641: UPS Network Management Card with • SRT012: APC Smart-UPS SRT 2.2/3 kVA
Environmental Monitoring input/output HW kit
• AP9643: UPS Network Management Card with
Transformers
Environmental Monitoring and Modbus Support
• AP9810: APC dry contact I/O accessory • SRT5KTF: APC Smart-UPS RT 3/5/6 kVA isolation
• AP9624: UPS interface expander and step-down transformer
Management card
• AP9613: Dry contact I/O SmartSlot card • SRT10KRMTF: APC Smart-UPS RT 8 / 10 kVA
isolation and step-down transformer
Battery packs
Service bypass panels
• SRT48BP: APC Smart-UPS SRT 48 V 1 kVA and
1.5 kVA battery pack • SBP1500RMI: APC service bypass panel 230 V;
• SRT48RMBP: APC Smart-UPS SRT 48 V 1 kVA 10 A; BBM; IEC-320 C14 input; IEC-320 C14 / C13
and 1.5 kVA battery back output
• SRT72BP: APC Smart-UPS SRT 72 V 2.2 kVA • SBP3000RMI: APC service bypass panel 230 V;
Battery pack 16 A; BBM; IEC-320 C20 input; IEC-320 C20 /C19
battery pack
• SRT72RMBP: APC Smart-UPS SRT 72 V 2.2 kVA output
RM battery pack • SBP3000RMHW: APC service bypass panel 230
• SRT96BP: APC Smart-UPS SRT 96 V 3 kVA V; 16 A; BBM; hardwire input; IEC-320 C20 /C19
battery pack output
• SRT96RMBP: APC Smart-UPS SRT 96 V 3 kVA • SBP6KRMI2U: APC service bypass panel 230 V;
RM battery pack 50 A; MBB; hardwire input; (4) IEC-320 C19 output
• SRT192BP: APC Smart-UPS SRT 192 V 5 kVA • SBP10KRMI4U: APC service bypass panel 230 V;
and 6 kVA battery pack 100 A; MBB; hardwire input; IEC-320 output (8)
• SRT192RMBP: APC Smart-UPS SRT 192 V 5 kVA C13 (2) C19
and 6 kVA RM battery pack Other
• SRT192BP2: APC Smart-UPS SRT 192 V 8 kVA
SURT013: SURT Equipment Cart
and 10 kVA battery pack
• SRT192RMBP2: APC Smart-UPS SRT 192 V Replacement Battery Cartridge
8 kVA and 10 kVA RM battery pack APCRBC140: RBC for SRT 5 kVA - 10 kVA UPS
• SRT002: APC Smart-UPS SRT 5 M extension cable APCRBC141: RBC for SRT 2.2 kVA UPS
for 192 VDC External Battery Packs 5/6 kVA UPS APCRBC152: RBC for SRT 3 kVA UPS
• SRT003: APC Smart-UPS SRT 5 M extension cable APCRBC155 RBC for SRT 1-1.5 kVA UPS
for 192 VDC External Battery Packs 8/10 kVA UPS
• SRT009: APC Smart-UPS SRT 5 M extension cable
for 72 VDC external battery pack 2.2 kVA UPS
• SRT010: APC Smart-UPS SRT 5 M extension cable
for 96 VDC external battery pack 3 kVA UPS

Rail kits
• SRTRK2: APC Smart-UPS SRT 19 inch rail kit
for Smart-UPS SRT 5/6/8/10 kVA UPS
• SRTRK3: APC 2-post mounting rail kit for
Smart-UPS SRT 2.2/3/5/6/8/10 kVA UPS
• SRTRK4: APC Smart-UPS SRT 19 in rail kit for
Rail kits
Smart-UPS SRT 1/1.5/2.2/3 kVA UPS
apc.com 10

Smart-UPS On-Line runtime


Runtime estimates at half and full load (minutes)

SRT3000XLI (RM) (RM-NC)


UPS SRT1000XLI (RM) (RM-NC) SRT1500XLI (RM) (RM-NC) SRT2200XLI (RM) (RM-NC)
SRT3000XLW-IEC (RM)
half/full loads (500 W/1,000 W) (750 W/1,500 W) (990 W/1,980 W)
(1,350 W/2,700 W)

Internal 21.5/8.4 14.6/4.0 11.6/3.9 11.8/4.0

(1) Battery pack 90.0/40.0 63.0/27.0 45.7/20.2 46.4/20.5

(2) Battery packs 134.0/63.0 95.1/45.0 82.1/37.6 83.3/38.1

(3) Battery packs 194.0/92.0 138.7/66.3 119.9/55.6 121.6/56.3

(4) Battery packs 257.0/122.0 183.4/88.2 158.6/74.1 160.9/75.1

SRT5KXLI (RM)
UPS SRT6KXLI (RM) SRT8KXLI (RM) SRT10KXLI(RM)
SRT5KRMXLW-HW
half/full loads (3,000 W/6,000 W) (4,000 W/8,000 W) (5,000 W/10,000 W)
(2,250 W/4,500 W)

Internal 11.8/4 8.7/2.5 14.5/5.2 11.5/3.8

(1) Battery pack 46.2/20.5 36/15.5 34.5/14.7 28/11.6

(2) Battery packs 83/38 65.2/29.4 55.43/24.63 45.3/19.8

(3) Battery packs 121/56.4 95.5/43.8 77/34.84 63.1/28.2

(4) Battery packs 160.4/75.1 126.6/58.6 99.1/45.33 81.3/36.8


apc.com 11

Smart-UPS On-Line SRT


1000 VA and SRT 1500 VA technical specifications

SRT1000XLI SRT1500XLI
SRT1000RMXLI SRT1500RMXLI
Product feature
SRT1000RMXLI-NC SRT1500RMXLI-NC
(Pre-installed NMC, AP9641) (Pre-installed NMC, AP9641)

Output

Power rating 1000 VA/ 1000W 1500 VA/ 1500 W

Nominal output voltage 230 V (220 V, 240 V user selectable)

Output frequency 50/60 Hz ± 3 Hz (auto sense) 50/60 Hz ± 0.1 Hz (user selectable)

Topology Double-conversion online

Online efficiency at full load (typical) 91% 92%

Green mode efficiency at full load (typical) 94% 96%

Output connections (switched groups) (6) IEC 320 C13

Input

Nominal input voltage 220, 230, 240 V

Input voltage range full load (half load) 176 – 275 V (100 – 275 V)

Input frequency 40 – 70 Hz

Input connection IEC-60320 C14

Batteries and runtime

Battery type Sealed, maintenance-free, valve-regulated lead-acid battery

Replacement battery (quantity) APCRBC155

External battery pack (tower/rack mount) SRT48BP/SRT48RMBP

Communication and management

Interface ports Serial (RJ45), USB (Type A) and SmartSlot

Control panel Multi-function LCD status and control console. Audible and visible alarms prioritized by severity.

Emergency power off (EPO) Yes (NO/NC connections)

Physical

Rack height 85 mm, 2U

Maximum width (RM) 432 mm

Maximum depth (RM) 505 mm

Net weight 22.0 kg

Conformance

CE, CE Mark, VDE, RCM, and EAC, IEC/EN 62040-1, CE, CE Mark, VDE, RCM, and EAC, IEC/EN 62040-
Regulatory
IEC/EN 62040-2 1, IEC/EN 62040-2

Warranty Three years for electronics/two years for battery


apc.com 12

Smart-UPS On-Line SRT


2200 VA and SRT 3000 VA technical specifications

SRT2200XLI SRT3000XLI
SRT2200RMXLI SRT3000RMXLI SRT3000XLW-IEC
Product feature
SRT2200RMXLI-NC SRT3000RMXLI-NC SRT3000RMXLW-IEC
(Pre-installed NMC, AP9641) (Pre-installed NMC, AP9641)

Output

Power rating 2200 VA/1980 W 3000 VA/2700 W

230 V (208 V, 220 V, 240 V


Nominal output voltage 230 V (220 V, 240 V user selectable)
user selectable)

Output frequency 50/60 Hz ± 3 Hz (auto sense) 50/60 Hz ± 0.1 Hz (user selectable)

Topology Double-conversion online

Online efficiency at full load (typical) 92%

Green mode efficiency at full load (typical) 96% 97%

Output connections (switched groups) (8) IEC 320 C13, (2) IEC 320 C19 (4) IEC320 C13, (2) IEC320 C19

Input

230 V (208 V, 220 V, 240 V


Nominal input voltage 230 V
user selectable)

Input voltage range full load (half load) 160 – 275 V (100 – 275 V)

Input frequency 40 – 70 Hz

Input connection IEC-60320 C20, Schuko CEE 7/EU1-16P, British BS1363A

Batteries and runtime

Battery type Sealed, maintenance-free, valve-regulated lead-acid battery

Typical backup time at ½ load (min) 11.6 min 11.8 min

Typical backup time at full load (min) 3.9 min 4.0 min

Replacement battery (quantity) APCRBC141 (1) APCRBC152 (1)

External battery pack (tower/rack mount) SRT72BP/SRT72RMBP SRT96BP/SRT96RMBP

Communication and management

Interface ports Serial (RJ45), USB (Type A) and SmartSlot

Control panel High-resolution graphical LCD display

Emergency power off (EPO) Yes (NO/NC connections)

Physical

Rack height 85 mm, 2U

Maximum width (RM) 432 mm 432 mm

Maximum depth (RM) 585 mm 636 mm

Net weight 25 Kg 31 kg

Conformance

CE, VDE, RCM, and EAC, IEC/EN CE, VDE, RCM, and EAC, IEC/EN 62040-1, IEC/EN 62040-2, UL-1778,
Regulatory
62040-1, IEC/EN 62040-2 FCC Part 15 Class A, CSA

Warranty Three years for electronics/two years for battery


apc.com 13

Smart-UPS On-Line SRT


5 kVA – 10 kVA technical specifications

SRT5KXLI SRT6KXLI SRT8KXLI SRT10KXLI


Product feature SRT5KRMXLW-HW
SRT5KRMXLI SRT6KRMXLI SRT8KRMXLI SRT10KRMXLI

Output

Power rating 5,000 VA/4,500 W 6,000 VA/6,000 W 8,000 VA/8,000 W 10,000 VA/10,000 W

230 V (220 V, 240 V, 208 V user


Nominal output voltage 230 V (220 V, 240 V user selectable)
selectable)

Output frequency 50/60 Hz ± 3 Hz (auto sense) 50/60 Hz ± 0.1 Hz (user selectable)

Topology Double-conversion online

Online efficiency at full load (typical) 94%

Green mode efficiency at full load (typical) 98%

Hardwire three-wire (6) IEC 320 C13 (6) IEC320 C13, (4) IEC320 C19,
Output connections
(1 PH + N + G) or (2 PH + G) (4) IEC 320 C19 hardwire three-wire (1 PH + N + G)

Input

Nominal input voltage 208 V, 220 V, 230 V, 240 V 220 V, 230 V, 240 V 220 V/380 V, 230 V/400 V, 240 V/ 415 V

Input voltage range full load (half load) 160 – 275 V (100 – 275 V) 160/277 – 275/476 V (100/173-275/476 V)

Input frequency 40 – 70 Hz

Hardwire three-wire Hardwire three-wire Hardwire three-wire (1 Ph+N+G),


Input connection
(1 Ph+N+G) or (2 PH + G) (1 Ph+N+G) Hardwire five-wire (3 Ph+N+G)

Batteries and runtime

Battery type Sealed, maintenance-free, valve-regulated lead-acid battery

Typical backup time at 1/2 load (min.) 11.8 min. 8.7 min. 14.5 min. 11.5 min.

Typical backup time at full load (min.) 4 min. 2.5 min. 5.2 min. 3.8 min.

Replacement battery (quantity) APCRBC140 (1) APCRBC140 (2)

External battery pack (tower/rack mo


SRT192BP/SRT192RMBP SRT192BP2/SRT192RMBP2
unt)

Communication and management

Embedded network management with environmental monitoring, which includes an RJ-45 with status LEDs (10/100/1000
Interface ports
Base-T), USB ports, Serial port, Universal IO port, console port

Control panel High-resolution graphical LCD display

Emergency power off (EPO) Yes (normally open, NO/ normally closed, NC connections)

Physical

Rack height 3U 4U 6U 6U

Maximum height (RM) 130 mm 174 mm 263 mm 263 mm

Maximum width (RM) 432 mm 432 mm 432 mm 432 mm

Maximum depth (RM) 719 mm 719 mm 715 mm 715 mm

Net weight 54.5 kg 60 kg 112 kg 112 kg

Conformance

UL-1778, FCC Part 15 Class A,


Regulatory CSA, CE, VDE, RCM, and EAC, CE, VDE, RCM, and EAC, IEC/EN 62040-1, IEC/EN 62040-2
IEC/EN 62040-1, IEC/EN 62040-2

Warranty Three years for electronics/two years for battery


Schneider Electric

132 Fairgrounds Road


West Kingston, RI 02892
Phone: 401-789-5735

www.apc.com

March 2022

©2022 Schneider Electric. All Rights Reserved. Schneider Electric | Life Is On is a trademark and the property of
Schneider Electric SE, its subsidiaries, and affiliated companies. This document has been
998-1243569_GMA-US_B printed on recycled paper

You might also like