The import will read the ASCII file and and create fixture profiles based on the text. It does not import fixture profiles from
the library.
ASCII importing does not give you a perfect show. You can get the setup and the show data, but might need to make a
lot of adjustments to have a show that look the same.
It is only possible to import an ASCII show from the USB tab in the Backup Menu.
When the ASCII Show Read button is selected in the tab, then a ASCII file needs to be selected.
The Overview
After a file have been selected, then the ASCII Show Read pop-up is displayed. This pop-up is separated into different
tabs. The first one is called Overview and could look like this:
In the overview the console manufacturer and console type that made the export can been seen. It is also possible see
the show file name from the ASCII file.
In the Overview tab it can be decided where the Default Sequence should be. And if should be created and assigned to an
Executor and Executor page.
It can be decided if the submasters from the ASCII file are wanted and what page they are desired. It can be chosen from
what group number the inhibits from the ASCII file are wanted.
It is also possible to choose the first sequence number from the Effects. And if they should be assigned to Executors and
then the first Executor page.
Attribute
Before importing any data, you need to make sure the attributes from the ASCII file matches the attributes in the
grandMA.
This can be matched and changed in the Attribute tab. It could look like this:
Selecting one of the MA attribute allows this to be changed to any of the existing attributes in the MA.
Attributes that does not exist can be created in the Attributes and Encoder Grouping window.
Patch setting
Some consoles allowed an alternative DMX address. This Patch setting allows you to import the primary patch "Patch 1"
or the secondary patch "Patch 2". If you are in any doubt, then just leave this setting at "Patch 1".
Link setting
The Link setting has two options: "Go" or "Toggle". This decides whether the triggered effects gets a Go or Toggle
commend in the CMD column in the Default sequence. All Effects are sequences that are executed from the CMD column.
Remember that Effects are imported as sequences and depending on your settings in the Overview they are assigned to
Executors.
This can be done all at once by tapping the Complete button. This will load the Setup and the Show Data. This is good
if you know that it will work and there are no errors.
It is also possible to do it in two steps. If the Setup Only button is tapped, then the fixture schedule and the patch is
displayed. Then you can check that all is there and the patch is ok, simply by opening the setup.
Restriction:
If the Setup is not correct, then the Show Data will not import correctly.
After you have checked the setup, then go back to the ASCII Show Read in the Backup Menu. You might be asked for the
show file again. Please select the same file.
Now tap the Data Only button, this imports the Show Data.
Using the Setup Only and Data Only buttons also allows you to import the separate parts. For instance if you only
need the setup and patch from a show or if you already have everything patched and just need the show data. The Data
Only import is looking for the ID numbers when it imports. So if a fixture exists and is correctly patched then the data will
import.
Log files
Importing from the show file will create different log files. These files can be seen in the three remaining tabs. The log
files also exists in the "temp" folder in the consoles structure. To get to them a FTP connection is needed. Read about it in
the FTP Connection to Console and NPU topic.