Esp. Tecnica Re92750
Esp. Tecnica Re92750
Esp. Tecnica Re92750
98
RE 92 750/03.98
replaces: 12.95
Sizes 18...63
Series 1
Nominal pressure 300 bar
Peak pressure 350 bar
A10VG...HD
Index Features
A10VG 1/24
RE 92 750/03.98
Hydraulic fluid
Mineral oil (no code)
Operation
Pump in closed circuits G
Size
Displacement Vg max in cm3 18 28 45 63
Control device 18 28 45 63
Mechanical pivot control MD – – – MD
Hydraulic control, direct operated DG DG
Electrical control with proportional solenoid EP EP
Electrical two-position control with switching solenoid EZ EZ
Hydraulic control, mechanical servo HW HW
Hydraulic control, pilot pressure related HD HD
Hydraulic control, speed related DA – DA
Pressure cut-off
without pressure cut-off (no code)
with pressure cut-off (standard for version with DA-control valve) – D
DA control valve EZ DG EP HW HD DA 28 45 63
without DA control valve – 1
with DA control valve, fixed setting – 2
with DA control valve, mech. adjustable with control lever L – 3L
R – 3R
with DA control valve, fixed setting and hydraulic inch
– – – – – 4
valve built-on, control with breaking fluid
with DA control valve, mech. adjustable with control lever L – – – – – 5L
and hydraulic inch valve built-on, control with breaking fluid R – – – – – 5R
with DA control valve, fixed setting and connections for master controller – 7
with DA control valve, fixed setting and hydraulic inch
– – – – – – 8
valve built-on, control with mineral oil
with DA control valve, mech. adjustable with control lever L – – – – – – 9L
and hydraulic inch valve built-on, control with mineral oil R – – – – – – 9R
A10V G / 10 – N C
Axial piston unit
Operation
Size
Control device
Series
Index
Direction of rotation 18 28 45 63
viewed on shaft end clockwise R
anti-clockwise L
Seals 18 28 45 63
NBR, shaft seal in FPM (fluor-caoutchouc) N
Mounting flange
SAE 2-hole C
= available
– = not available
Technical Data
Fluid
We request that before starting a project detailed information about temperature range, the operating viscosity lies within the optimum
the choice of pressure fluids and application conditions are taken range (νopt) (see shaded section of the selection diagram). We
from our catalogue sheets RE 90220 (mineral oil), RE 90221 recommend that the highest possible viscosity range should be chosen
(environmentally acceptable hydraulic fluids) and RE 90223 (fire in each case.
resistance fluids, HF). Example: At an ambient temperature of X°C the operating
When using HF- or environmentally acceptable hydraulic fluids temperature is 60°C. Within the operating viscosity range (νopt; shaded
possible limitations for the technical data have to be taken into area), this corresponds to viscosity ranges VG 46 or VG 68. VG 68
consideration. If necessary please consult our technical department should be selected.
(please indicate type of the hydraulic fluid used for your application Important: The leakage oil (case drain oil) temperature is influenced
on the order sheet). The operation with HFA-, HFB- and HFC- hydraulic by pressure and pump speed and is always higher than the circuit
fluids requires additional special measures. temperature. However, at no point in the circuit may the temperature
exceed 115°C.
Operating viscosity range If it is not possible to comply with the above conditions because of
In order to obtain optimum efficiency and service life, we recommend extreme operating parameters or high ambient temperatures please
that the operating viscosity (at operating tem-perature) be selected consult us.
from within the range:
νopt = operating viscosity 16...36 mm2/s Temperature range of the radial shaft seal
The FPM shaft seal is admissible for a housing temperature range
referred to the circuit temperature (closed circuit).
from -25°C to +115°C.
Note:
Viscosity limits For applications below -25°C a NBR shaft seal is necessary
The limiting values for viscosity are as follows: (admissible temperature range: -40°C to +90°C).
νmin = 5 mm2/s, When ordering, please state in clear text: with NBR shaft seal
short term at a max. permissible temp. of tmax = 115°C.
Installation position
Please note that the max. fluid temperature is also not exceeded in
certain areas (for instance bearing area). Optional. The housing must be filled prior to commissioning, and
must remain full whenever it is operating.
νmax = 1600 mm2/s,
For extensive information on the installation position, please read
short term on cold start (tmin = -40°C).
our data sheet RE 90270.
At temperatures of -25°C up to -40°C special measures are required.
Please contact us for further information.
Operating pressure range - inlet
Variable pump (with external supply, E)
Selection diagram
boost pressure pSp: control device DA, DG _________________ 25 bar
2500-40° -20° 0° 20° 40° 60° 80° 100°
1600 1600 control device HD, HW, EP, EZ (n = 2000 rpm) ___ 18 bar
1000
600
400 Auxiliary pump
suction pressure ps min: ν ≤ 30 mm2/s _______________ ≥ 0,8 bar abs.
V 68
VG
V 32
V 46
V
200
G
G
G
G
10
22
100
60
40
,,,,,,,,,,,, Operating pressure range - outlet
viscosity ν in mm2/s
36
,,,,,,,,,,,,
,,,,,,,,,,,, νopt. Variable pump (pressure at ports A or B)
20 ,,,,,,,,,,,,
,,,,,,,,,,,, 16
nominal pressure pN ___________________________ 300 bar
10 peak pressure pmax ____________________________ 350 bar
Auxiliary pump
5 5
-40° -25° -10° 0° 10° 30° 50° 70° 90° 115° peak pressure pH max size 18 ________________ 25 bar
temperature t in °C
peak pressure pH max sizes 28, 45, 63 ________________ 40 bar
tmin = -40°C tmax = +115°C
fluid temperature range (pressure data to DIN 24312)
Notes on the selection of the hydraulic fluid
Case drain pressure
In order to select the correct fluid, it is necessary to know the operating
temperature in the circuit (closed loop) in relation to the ambient Permissible case drain pressure at ports T1 or T2
temperature. pL _______________________________________ 4 bar abs.
The hydraulic fluid should be selected so that within the operating short term (at start) __________________________ 6 bar abs.
Technical Data
Table of values (theoretical values, not considering ηmh and ηv; values rounded)
Size 18 28 45 63
Displacement variable pump Vg max cm3 18 28 46 63
auxiliary pump VgH cm3 5,5 6,1 8,4 14,9
Speed maximum nmax rpm 5000 4250 3800 3500
minimum nmin rpm 500 500 500 500
Flow at nmax variable pump qV max L/min 90 119 175 221
Power at nmax variable pump ∆p = 300 bar Pmax kW 45 59 87 110
Torque at Vg max variable pump ∆p = 300 bar Tmax Nm 86 134 219 301
(without aux. pump)
∆p = 100 bar T Nm 28,6 44,5 73 100
Moment of inertia (about drive axis) J kgm2 0,00093 0,0017 0,0033
Weight (standard model, without through drive) m kg (approx.) 14 (18) 1) 25 27 39
1) 14 kg: MD control, 18 kg: HD control
Calculation of size
Vg • n • ηv
Flow qV = in L/min Vg = displacement per revolution in cm3
1000 T = torque in Nm
∆p = pressure differential in bar
Vg • ∆p 1,59 • Vg • ∆p n = speed in rpm
Torque T = = in Nm
20 • π • ηmh 100 • ηmh ηv = volumetric efficiency
ηmh = mechanical-hydraulic efficiency
2 π •T • n T•n qV • ∆p ηt = overall efficiency (ηt = ηv • ηmh)
Power P = = = in kW
60 000 9549 600 • ηt
Filtration
Before finalising your design, please request a certified drawing.
The finer the filtration the better the achieved purity grade of the
pressure fluid and the longer the life of the axial piston unit. Circuit diagram (pressure filtration)
To ensure the functioning of the axial piston unit a minimum purity
grade of:
9 to NAS 1638
6 to SAE
18/15 to ISO/DIS 4406 is necessary.
In this case we recommend, depending on system and application
filter element β20 ≥ 100
for the A10VG. With the rising differential pressure at the filter element
the β-value must not decrease.
At very high temperatures of the hydraulic fluid (90°C to max. 115°C)
at least cleanless class
Size 28, 45 Size 63
8 to NAS 1638 D1
5 to SAE
17/14 to ISO/DIS 4406 is necessary.
D4
If above mentioned grades cannot be maintained please consult
D3
D3
supplier.
G(Fa)
D2
Through flow resistance at the filter element:
D5
D2
at ν = 30 mm2/s, n = nmax ___________________ ∆p ≤ 0,1 bar
at ν = 1000 mm2/s, n = 1000 rpm ____________ ∆p ≤ 0,3 bar
G(Fa)
Pressure at port S of the auxiliary pump:
at ν = 30 mm2/s ___________________________ p ≥ 0,8 bar
at cold start _______________________________ p ≥ 0,5 bar Size D1 D2 D3 D4 D5 Fe, Fa, G1)
28 164,9 169,9 65,5 23 80,5 M18x1,5
Variation: Filtration in the pressure line of the auxil.pump, 45 178,6 180,6 71,5 23 83,5 M18x1,5
ports for external boost circuit filter, D 63 189,8 19,5 82,5 – – M18x1,5
Filter inlet ________________________________ port Fe
1
) For sizes 28 and 45 port G is used as the "Filter outlet Fa". Pressure
Filter outlet (size 63) __________________________ port Fa
filtration is for sizes 28 and 45 not possible in conjunction with a DA
(size 28, 45) _____________________ port G(Fa)
control valve (see ordering code on page 3).
Filter type: Filter with bypass are not recommended, when applying
with bypass please consult supplier.
Variation: external supply, E
Recommendation: with contamination indicator
This variation is to be applied with models without integral auxiliary
Resistance to flow at the filter element: pump (N00 or K..).
at ν = 30 mm2/s ___________________________ ∆p ≤ 1 bar
Boost pressure is via:
at cold start _____________________________ ∆pmax = 3 bar
size 18 _____________________________________ port S
(valid for entire speed range nmin – nmax)
size 28, 45 (without DA control valve) _______________ port G
Please note: size 28, 45 (with DA control valve) _________________ port Fe
- at size 28, 45 variation is not possible with DA control valve size 63 _____________________________________ port Fa
- for type with DG control (with control pressure not from the supply Port S is plugged on sizes 28, 45 and 63.
circuit) the following filter type has to be used:
Filter arrangement: separately
filter with bypass and with contamination indicator To ensure functioning the above mentioned purity grade for the boost
pressure fluids at connection G has to be ensured.
Setting diagram The pressure cut-off corresponds to a pressure regulation which, after
pmax
≥10 bar
reaching the set pressure, adjusts the pump volume of the pump to
Vg = 0.
This valve prevents the operation of the high pressure relief valves
∆p drive design
pressure
boost pressure
qV 1 qV max the entire working pressure range. However, it must be set 20-30
Example (design without pressure cut-off): bar lower than the setting of the high pressure safety relief valves
(see diagram).
operating pressure pA,B – boost pressure psp = differential pressure ∆pHD
300 bar – 20 bar = 280 bar Please state the setting value of the pressure cut-off in clear text
pmax when ordering.
≥20 bar
safety margin set value high press. (HD) valve setting Circuit diagram
differential pressure ∆pHD
pressure cut-off
operating pressure pA, B
with pSp
pressure cut-off
pSp
boost pressure
qV 1 qV max
Please note:
- valve setting is done at through flow quantity qV 1 = 6 - 10 L/min
- simplification: the bypass function is not shown in the hydraulic
schemes
The pump swivels out to an oil flow between 0 and Vg max by means The positioning cylinder of the pump and therefore the swivel angle
of pressure load at the positioning chamber through control pressure is varied in proportion to the difference in pilot pressure applied to
at the ports X1 or X2. Each port determinate one direction of flow the two control ports (Y1 and Y2). The pump displacement is therefore
(see table below). steplessly variable. One pilot line is assigned to each direction of
The oil flow value which results from a defined control pressure is flow.
pSt in bar
under these conditions dependent from the speed and the operating 18
pressure. 16
14
12 size 45
10
pilot pressure 0 bar displacement Vg = 0 8
max. perm. control pressure: 40 bar 6
4
2
0
V g 1,0 0,8 0,6 0,4 0,2
2
0 0,2 0,4 0,6 0,8 1,0 V
g
–
V g max 4 V g max
6
8
10
12
14
16
18
- pSt in bar
HD control size 18 28 45 63
Start of control (Vg 0) pSt bar 6 6 6 6
End of control (Vg max) pSt bar 15,7 16 16,7 16,7
pSt : pilot pressure at ports Y1, Y2
Control pressure X1 X2 X1 X2
Direction of flow A to B B to A B to A A to B
anti-
Operating pressure MB MA MA MB
anti-
clockwise Pilot pressure Y1 Y2 Y1 Y2 clockwise
HD control
Control pressure X1 X2 X1 X2
clockwise Direction of flow A to B B to A B to A A to B clockwise
Operating pressure MB MA MA MB
The positioning cylinder of the pump and therefore the swivel angle Variation: zero position switch, L
is varied in proportion to the movement of the control lever. The At zero position of the control lever the switch contact is closed. In
pump control is steplessly variable. case of start-on of the control lever from the center position the
Each direction of flow is assigned to one direction of lever movement. contact is interrupted.
The zero position switch assures a safety function for drives which
β in o
40 necessiate the zero position under certain conditions (for example
start of the diesel engine).
30
30
40
− β in o
Control pressure X1 X2 X1 X2
clockwise
Direction of flow A to B B to A B to A A to B
clockwise
Operating pressure MB MA MA MB
zero position switch
In relation to the drive speed, control pressure is applied to the DA control valve, fixed setting, (DA..2)
positioning cylinder of the pump by means of the DA control valve Control pressure is generated in relation to drive speed. When
via a 4/3 way directional valve. Pump displacement is steplessly va- ordering, please state in clear text: Start of control (set at factory)
riable in each direction of flow. Each direction of flow is assigned to
one of the two solenoids on the directional valve.
Increasing drive speed generates a higher control pressure through
the DA valve.
Increasing control pressure increases the pump displacement.
Dependent upon the pump operating curve, pressure in the high
pressure lines causes the pump to swivel back towards a smaller
displacement.
Increasing operating pressure gives reduced displacement.
A constant torque input to the pump is achieved by this combination
of de-stroking of the pump as the operating pressure increases and
A2
in response to the “pull-down” of the prime mover (leading to a
reduced control pressure).
The least possible pull down leads to optimum usage of the drive
power. This is achieved by “partial inching”. In this form of the control,
A3 Size 28 45 63
the DA valve is mechanically coupled to the accelerator pedal. This
means that on reaching a certain speed (movement of the accelerator A1 154 157 154,5
pedal), the control curve is offset parallel to the engine speed curve.
A2 15,5 23 24,5
A1
Any additional power requirements, e.g. the service hydraulics, may
lead to engine pull down occuring. This leads to a reduction in control A3 164,9 178,6 186,3
pressure and therefore pump displacement. The power thus released
is then available to supply that demanded. Automatic power division
and full utilisation of power available is thus achieved for both the DA control valve, mechanically adjustable with control
vehicle transmission and the service hydraulics. lever (DA..3)
In an automative transmission, the DA control valve is used in Control pressure is generated in relation to drive speed. When ordering,
conjunction with the directly controlled hydraulic “DA control”. please state in clear text: Start of control (set at factory).
However, pumps with HD, HW, EP or DG controls can also be equipped Control pressure may be reduced (independently of drive speed) as
with a DA control valve. In this way, the automatic transmission required by operation of the control lever (inch function).
function (speed related high pressure/flow increase with load limiting Max. adm. operating torque at the control lever: ___ Tmax= 4 Nm
control) may be overridden. Max. angle of lever operation 70°. The position of the lever is optional.
The maximum flow will then be determined by the setting of the
relevant control module fitted.
anti-
clockwise
A3
Size 28 45 63
A1 176 176 185
clockwise
A1
A2 15,5 23 24,5
In relation to the preselected current, control pressure is applied to By energizing either solenoid a or b the swashplate and thus the
the positioning cylinder of the pump via two proportional solenoids displacement is switchable from Vg = 0 to Vg max .
on control device EP. The displacement of the pump is thus steplessly Each direction of flow is assigned to a solenoid.
variable. One solenoid is assigned to each direction of flow.
solenoid de-energized pump set to Vg = 0
Operating curve EP2 solenoid energized pump set to Vg max
I in mA
800
700
EZ1 switching solenoid 12 V, 26 W
600
EZ2 switching solenoid 24 V, 26W
500
400 size 45
300
200
100
0
V g 1,0 0,8 0,6 0,4 0,2 0 0,2 0,4 0,6 0,8 1,0 V
g
–
V g max 200 V g max
300
400
500
600
700
800
– I in mA
Control pressure X1 X2 X1 X2
proportional solenoid a Direction of flow A to B B to A B to A A to B switching solenoid a
anti- anti-
clockwise Operating pressure MB MA MA MB clockwise
Solenoid b a b a
EZ control
Control pressure X1 X2 X1 X2
clockwise clockwise
Direction of flow A to B B to A B to A A to B
Operating pressure MB MA MA MB switching solenoid b
proportional solenoid b
The swashplate angle is varied directly by the rotary movement of The mechanical stroke limiter is an additional function that
the pivot. The pump displacement is steplessly variable. Each direction independently from the relevant control unit makes it possible to
of flow is assigned to one direction of rotation of the pivot. infinitely reduce the maximum displacement of the pump.
β in o The stroke of the adjustment cylinder is limited by two adjustment
20 screws which, thereby also limit the pump swivel angle.
15
10
V g 1,0 0,8 0,6 0,4 0,2 0 0,2 0,4 0,6 0,8 1,0 V
g
–
V g max 5 V g max
10
15
20
− β in o
Size 18 28 45 63
M1
M1 99 101,6 124
M2 42,1 35 35,5 43
M1
Control pressure X2 X1 X2 X1
clockwise Direction of flow B to A A to B A to B B to A
Operating pressure MA MB MB MA
mechanical centering
adjustment
HD-valve
boost pressure
valve
HD-valve
83
max max
Electrical two-position control with switching solenoid, EZ Mechanical pivot control, spring centering to neutral, MDN
G (Fa)
G (Fa)
71
boost pressure
valve
HD-valve:
without bypass
with bypass
View Z
Fe M10; 17 deep
65
M10; 17 deep
90.7
Electrical control with proportional solenoid, EP Hydraulic control, speed related, DA
(dimensions of the DA control valve see page 10)
178,4
93,6
154,4
153
G
Note:
Location and size of port G (M10x1; 8 deep)
for the version fitted with a DA control valve.
G
7
Note:
Location and size of port G (M10x1; 8 deep)
for the version fitted with a pressure cut-off.
G (Fa)
G (Fa)
HD-valve:
without bypass
with bypass
View Z
M10; 17 deep
Fe
68
M10; 17 deep
11
G
Note:
Location and size of port G (M12x1,5; 12 deep)
for the version fitted with a DA control valve.
Note:
Location and size of port G (M12x1,5; 12 deep)
for the version fitted with a pressure cut-off.
mechanical centering
adjustment
HD-valve
with bypass
64,5 without bypass
Z
54,5
138,5
(Fa)
boost pressure valve
HD-valve
without bypass
with bypass
View Z
M10; 17 deep
M10; 17 deep
96
96
Note:
Location and size of port G (M14x1,5; 12 deep)
for the version fitted with a DA control valve.
G
96
96
Note:
Location and size of port G (M14x1,5; 12 deep)
for the version fitted with a pressure cut-off.
ø82,55
106,4
45 234,4 9
63 242,2 9
Without auxiliary pump, without through drive, (N00) With auxiliary pump, without through drive, (F00)
(see unit dimensions pages 14 - 21)
Size A1
18 169,4
28 201,7
45 216,8
63 224,5
Size 18 28 45 63
Corner torque (when Vg max, ∆p = 300 bar) 1) Tmax Nm 86 134 219 301
Max. perm. through drive rotation torque TD perm. Nm 112 220 314 439
Max. permissible input torque 2)
Combination Pumps
Combination pumps offer the facility of independent circuits without the need to fit splitter boxes.
When ordering combination pumps the model descriptions have to be connected by a "+" sign:
order example: Code 1st pump (front pump) + Code 2nd pump (rear pump)
A10VG 45HW1/10R–PTC10F042S + A10VG 45HW1/10R–PSC10F002S
The series connection of two single pumps of the same size is permissible without additional supports where the dynamic acceleration does
not exceed 10 g (= 98,1m/s2).
63 SAE C, 2-hole 181 18 127 18 S (SAE 1 1/4") T (SAE 1 3/8") F07/K07 S (SAE 1 1/4")
Type Ident-No. In order to assure that rotating parts (coupling hub) and fixed parts
(housing, safety rings) do not contact each other the installation
A10VG18MD/10R-NSC16F003S 2005230
situations are described in this leaflet have to be observed. The
A10VG18MD/10R-NSC16F013S 2010550 installation situation depend upon the sizes and the spline.
A10VG18EP11/10R-NSC16F005S 2025955
A10VG18EP11/10R-NSC16F015S 2025956 Sizes 18...45 (with free turning):
A10VG18HW1/10R-NSC16F005S 2025957 Please observe diameter of the free turning.
A10VG18HW1/10R-NSC16F015S 2025958
Size 63 (without free turning):
The outer diameter of the coupling hub must be smaller than the
A10VG28EP11/10R-NSC10F005S 2020156 inner diameter of the circlip at the zone of the drive shaft collar
A10VG28EP11/10R-NSC10F015S 2020155 (measure x2 - x4).
A10VG28EP11/10R-NSC10F045S 2020157
A10VG28HW1/10R-NSC10F005S 2020195
A10VG28HW1/10R-NSC10F015S 2020194 Size ød1 ød2 min ød3 ød4 ød5 x1 x2 x3 x4
A10VG28HW1/10R-NSC10F045S 2020196 18 30 36,1 49± 101,6 65 5,9+0,2 9,5-0,5 7 8+0,9
-0,6
A10VG45EP1M1/10R-NSC10F005S 2017642
A10VG45EP1M1/10R-NSC10F015S 2017641 SAE spline x2
A10VG45EP1M1/10R-NSC10F045S 2017643 (to ANSI B92.1a-1976)
x3
A10VG45HWM1/10R-NSC10F005S 2017720 x1
A10VG45HWM1/10R-NSC10F015S 2017718 coupling hub
A10VG45HWM1/10R-NSC10F045S 2017721
A10VG45DA1DM2/10R-NSC10F005S 2017813
A10VG45DA1DM2/10R-NSC10F015S 2017812
A10VG45DA1DM2/10R-NSC10F045S 2017814
x4