A1.24a Reflected Ceiling Plan West Level 4 Rev.4
A1.24a Reflected Ceiling Plan West Level 4 Rev.4
A1.24a Reflected Ceiling Plan West Level 4 Rev.4
1 / A1.24B
METAL REINFORCEMENT AT CEILING MOUNTED
EQUIPMENT, AND COORDINATE WITH EQUIPMENT SUSPENDED GWB CEILING
MANUFACTURER. PROVIDE ADDITIONAL METAL SUPPORT (GWB)
COMPONENTS NOT INDICATED ON THE STRUCTURAL
DRAWINGS AS REQUIRED TO SUPPORT ALL ITEMS IN
ACCORDANCE WITH THE MANUFACTURER'S 2'-0" x 2'-0" ACOUSTICAL PANEL CEILING
SEE SHEET
RECOMMENDATIONS. (APC-1)
8'-0"
2'-0"
1'-0"
12'-5 1/4" 12'-5 1/4" 12'-10 1/2" 12'-10 1/2" 9) ALL DIMENSIONS AND INSTALLED SYSTEMS SHALL BE
GWB 10 GWB GWB GWB 1 CHECKED AND VERIFIED BY THE CONTRACTOR AT THE PIPE GRID
10'-0" 10'-0" 9'-4 7/8" SITE. (PIPE)
5'-0"
SEE 6 / A4.05
10'-0"
18'-0"
ACB
EQ EQ
CL
NELMS INSTITUTE ELECTRICAL, TELECOM, RESTROOMS AND OTHER AREAS ACOUSTIC FELT BLADES
WD-3 WD-3
HQ LOUNGE NOT REGULARLY OCCUPIED ARE OMITTED FROM (AB-2)
4050 4055 ARCHITECTURAL DRAWINGS. REFER TO ELECTRICAL
2'-0"
4'-0"
ALIGN 4050E 10' - 0" HEIGHT ABOVE FIN FL LEVEL
(DASHED) LINE OF 11'-8" 11'-8"
OPENING BELOW 2 13) NOT ALL ACCESS DOORS ARE SHOWN, REFER TO XXX FINISH MATERIAL
GWB GWB MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
10'-0" OFFICE ACCESS DOOR REQUIREMENTS.
10'-0"
APC-1
APC-1 4005 SIM 2'-0" 2'-0"
EQ
8 SIM SIM EXPOSED EXPOSED CEILING
10'-0" CIRCULATION 8 3 14) REFER TO SPECIFICATIONS FOR BASIS OF DESIGN FOR
7 A7.43 UNPAINTED PAINTED / UNPAINTED
OFFICE CL APC-2 C499A CEILING TYPES AND SUSPENSION SYSTEMS.
A4.01 3 A7.03 A4.06
4004
EQ
A4.03 15) REFER TO A7.50 FOR INFORMATION ABOUT ROLLER
SLOPED SLOPED SOFFIT, HEIGHT VARIES
SHADES.
SLOPED CL XXX FINISH MATERIAL
EQ EQ LIGHT, SED
GWB 10'-0" TYPE X TYPE "A" SEE: 1 / A7.43
2" 16) FOR DESIGNATION AWP-3 IN CEILING PLANS, PROVIDE
APC-1 BC05 TYPE "B" SEE: 4 / A7.43
2 TYPE B ACOUSTIC WALL PANELS AT ALL INTERIOR PARTITION
STAIR 3-4
30'-0"
A7.01 LIGHT, SED HEADER WALLS FROM 10' AFF TO UNDERSIDE OF CONCRETE DECK
10'-0" S498B ABOVE. REFER TO INTERIOR ELEVATIONS.
OFFICE AWP-3 ACOUSTIC WALL PANEL
APC-2 WEARABLES & EXPOSED 18" GLASS DRAFT
4003 IMPLANTS LAB PAINTED 12'-4" STOP, ALL SIDES 17) PLACING OF ACCESS DOORS IN HARD SURFACE
4001 APC-4 OF OPENING CEILINGS OR WALLS, UNLESS SHOWN ON THE
SLOPED 2 ARCHITECTURAL DRAWINGS, SHALL NOT BE ACCEPTED, RECESSED OR SURFACE
2
GWB 10'-0" A4.41 OPEN TO ABV UNLESS APPROVED IN WRITING BY THE ARCHITECT. MOUNTED DOWNLIGHT
APC-1 A7.42
TYPE B TYP. LOCATE AND INSTALL ALL WORK AS REQUIRED TO
SIM SIM SIM SIM EXPOSED 3 PRECLUDE THE NEED FOR ACCESS THROUGH HARD
1 6 5 4 5 5 LAY-IN FIXTURE
OFFICE PAINTED A7.03 SURFACE WALLS AND CEILINGS. COORDINATION OF THIS
A7.01 A7.03 A7.03 A4.05 A7.03 A7.03 REQUIREMENT SHALL BE THE RESPONSIBILITY OF THE
4002 ROLL DOWN CONSTRUCTION MANAGER.
SMOKE CURTAINS, SUSPENDED FIXTURE
TYP. OF 4 BAYS 3 18) AT STAIR 1 AND STAIR 2, STEEL PAN STAIR SYSTEM TO
BE FACTORY PRIMED AND FIELD PAINTED.
5 SUSPENDED LINEAR FIXTURE
SIM 8
A4.05 7 12 5 8 1 4 19) FOR CEILING PAINTING DETAILS, REFER TO
10'-0"
9'-6" 9'-6" A4.02 CIRCULATION
1 A4.03 A4.03 A4.00 A4.04 A4.03 SPECIFICATIONS, AND SCHEDULE ON SHEET A9.21.
MOTORIZED WD-2 WD-2 C499D RECESSED LINEAR FIXTURE
A7.00
ROLLER SHADES
SEE: 1 / A7.50.
4 SUSPENDED SMALL ROUND FIXTURE
WC
4012
CIRCULATION 10'-0"
FS
GWB SUSPENDED LARGE ROUND FIXTURE
STAIR 1 ELEV 2 C499C 9'-0" SHAFT WORK ROOM
S498A E497B LOUNGE
CONF RM APC-5 SH-2 4015
9'-8"
4006 4010 WD-1
ELEC
10'-0" SPRINKLER HEAD
EL495A 9'-8"
CIRCULATION
17'-0"
ELEV 1 WD-1 GWB
EXPOSED E497C 10'-0" 9'-8" 10'-0" EXPOSED C499E
FS
ELEV 3 9'-8" GWB WD-1 GWB NURSING
PAINTED 10'-0" UNPAINTED S CEILING MOUNTED SENSOR
E497A GWB WD-1 4011 9'-8"
WD-1
9'-0"
APC-1 SP CEILING MOUNTED SPEAKER
FS 5
2'-0" 2'-5"
CL CL CL
SLOPED OFFICE STOR
10'-0"
ALIGN
4101 EQ EQ EQ EQ PROJECTOR
GWB 4102 APC-1
TYPE B CL
FS CEILING MOUNTED FIRE ALARM DEVICE
CYBER PHYSICAL
10'-0" ELECTRONICS STRUCTURAL
SYSTEMS EQ EQ EQ EQ SMART SYSTEMS
APC-1 TEST & HEALTH
RESILIENCE & LAB MOTORIZED ROLLER SHADE
SLOPED MEASUREMENT MONITORING LAB
ENERGY
LAB 4120 SEE: 20 / A7.50
GWB
EQ CL EQ MANAGEMENT LAB 4114 10'-0"
TYPE B
4100 10'-0" 10'-0"
4109 10'-0" APC-2
GWB APC-2 APC-2
33'-0"
8
A4.01 OFFICE 10'-0"
4103 APC-1
EQ
TYPE B
SM CONF RM
4104 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" OFFICE 10'-0" 10'-0"
10'-0"
APC-2 4105 APC-1 APC-1 4106 4107 APC-1 APC-1 4108 4110 APC-1 APC-1 4111 4112 APC-1 APC-1 4113 4115 APC-1 APC-1 4116 4117 APC-1 APC-1 4118 4119 APC-1 4123 APC-1
16
A4.02
6
FS
3 2
SLOPED A4.01 SLOPED SLOPED SLOPED SLOPED SLOPED SLOPED
A4.01
GWB GWB GWB GWB GWB GWB GWB
TYPE A TYPE A TYPE A TYPE A TYPE A TYPE A TYPE A
MOTORIZED
ROLLER SHADES
11 SEE: 7 / A7.50.
1 / A1.24B