RAG3080

The RAG3080 is an instantaneous auxiliary relay with eight changeover contacts and a transparent cover. It has various mounting options and is designed for applications in industries like power, rail, and manufacturing. The relay meets demanding international standards and has a mechanical life of 107 operations. It is available in different voltage ranges with options for things like high breaking capacity or seismic characteristics.

Uploaded by

andcrisdanmat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views2 pages

RAG3080

The RAG3080 is an instantaneous auxiliary relay with eight changeover contacts and a transparent cover. It has various mounting options and is designed for applications in industries like power, rail, and manufacturing. The relay meets demanding international standards and has a mechanical life of 107 operations. It is available in different voltage ranges with options for things like high breaking capacity or seismic characteristics.

Uploaded by

andcrisdanmat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CEE Relays Ltd

87C Whitby Road, Slough, SL1 3DR (Registered Office)

Tel: (01753) 576477 Fax: (01753) 825661


Web: www.ceerelays.co.uk

Instantaneous Auxiliary Relays (RAG3080)


The RAG3080 is an auxiliary relay with eight changeover contacts and a transparent cover. Different types of sockets, suitable for different methods of mounting, are
available, as shown on the second page of this datasheet. Other instantaneous relays (the RAG1020, RAG2040 and RAG4160) are also available.

New options have been included in the RAG series of relays. Its design, durability and quality guarantee its application in high dependency applications such as power
stations, substations, railway, and continuous process industries (petrochemical, rolling mills, cement and chemical industries). Relays in the RAG series of relays have
been designed and manufactured in accordance with the most demanding test standards (IEC, EN, IEEE) and bear the CE mark. Their making/breaking capacities, high
permanent current and overvoltage capacity allow direct action on HV and MV switchgear.

Range and Model Selection


RAG3080 Voltage OP X X X X X
(AC/DC)
Type
Standard
High speed trip relay (<10ms; Vdc only) R
Very high speed trip relay (<6.5ms; Vdc only) XR
Diode in parallel with the coil (Vdc only) DI
Seismic characteristics SY
Seismic characteristics and diode in parallel with the coil SYDI
(only Vdc)

Options
No 0
High breaking capacity (magnetic arc blow out)
Yes 1
No 0
Front LED
Yes 1
No 0
Contact position mechanical indicator
Yes 1
No 0
Relay trip flag
Yes 1
No 0
Push-to-test button To push the contacts 1
Fix the contacts 2

Characteristics
• Mechanical life: 107 operations • Contacts:
• Pick-up time: <20 ms Permanent current: 10 A
• Drop-out time: <15 ms/Vdc, <50 ms/Vac, Instant. current: 80A/200ms; 150A/10ms
<40 ms (DI and all relays with a front LED) Making capacity: 40A/0.5s/110Vdc
• Operating temperature: -10°C to +55°C Breaking capacity: see curves.
• Storage temperature: -30°C to +70°C Umax, opened contact: 250Vdc/400Vac
• Operating humidity: 93%/40°C • Standard voltages (UN):
24,48,72,96,110,125,220Vdc/Vac;50/60Hz

Type Voltage range Consumptions


Permanent Peak: up to 96Vdc Peak: over 96Vdc
Standard & DI +10%/-20% 6W; 11VA
R & XR +10%/-20% 1.5W 0.8A/20ms 2.5A/20ms 0.3A/20ms 0.8A/20ms
SY & SYDI +25%/-30% 6W; 11VA

Vibration and Shock Test (SY Models)


In Operation In Transit
IEC 60068-2-6 1g / 5Hz – 150Hz 2g / 5Hz - 150Hz
IEC 60068-2-6 5g / 11ms 15g / 11ms
IEC 60068-2-6 10g / 16ms

Registered in England No. 1977107


Instantaneous Auxiliary Relays (RAG3080)

Construction Standards
• Electrical test IEC60255-5 • Inflammability tests UL94: V0
Dielectric test 2kV/50Hz/1 min Plastic materials
Surge withstand 5 kV/1.2/50µs • Protection degree relay IEC60529, EN60529: IP40
Insulation >2,000MΩ/500Vdc • Climatic tests IEC60068-2
Thermal shock -25°C +70°C

EMC Tests
EN 60255-22-1 •High frequency burst disturbance test: EN 61000-4-6 •Conducted disturbances induced by radio
1MHz, 400 imp/s, 2 s frequency fields.
Common mode: 2.5 kV • Dif. mode:1kV 0.15-80MHz, 10V, 80% AM (1kHz)
EN 61000-4-4 •Electrical Fast transient burst: EN 61000-4-2 •Electrostatic discharges:
4kV, 2.5kHz, 1min•2kV, 5kHz, 1min Contact: ±15kV • Air mode: ±15kV
EN 61000-4-5 •Surge: 1.2/50µs.(voltage) EN 61000-4-8 •Power frequency magnetic field:
8/20µs.(current) 100A/m 1min•1000 A/m 1s.
Common mode: 2kV • Differential mode: 1kV EN 55011 •Radio disturbance. Cover:
EN 61000-4-3 •Radiated electromagnetic field: Test level: Class A 30-230MHz, 40dB(µV/m) (quasi peak)-10m
80-1000MHz, 10V/m, 80% AM (1kHz) 230-1000MHz, 47dB(µV/m) (quasi peak)-10m
EN 61000-4-3 •Digital telephones radiated Power supply:
electromagnetic field: 0.15-0.5 MHz, 79dB(µV)(peak)/66dB med. value
900 ±5MHz, 10V/m, 50% (200Hz) 0.5-5 MHz, 73dB(µV) (peak)/60dB med. value
1.89GHz ±10MHz, 10V/m, 50% (200Hz) 5-30 MHz, 73dB(µV) (peak)/60dB med. value

Sockets
Screw Double Faston
Front connection PAV3 IP10 PAV3-2C IP10
Rear connection PAR3 OP N/A

Weights
RAG3080 – 500g
PAV3 IP10 and PAV3-2C IP10 – 225g
PAR3 OP – 180g.