The document provides technical data and information on a fire-rated spray polyurethane foam insulation system. It details approvals, standards, applications, product descriptions, properties, and technical data of the two-part foam system. The foam is a Class 1 fire-rated, closed-cell foam that expands and adheres to surfaces, providing insulation, air sealing and soundproofing.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views

TechData - PU

The document provides technical data and information on a fire-rated spray polyurethane foam insulation system. It details approvals, standards, applications, product descriptions, properties, and technical data of the two-part foam system. The foam is a Class 1 fire-rated, closed-cell foam that expands and adheres to surfaces, providing insulation, air sealing and soundproofing.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

 

Rev  12/15    
TECHNICAL  DATA  SHEET  
   
E-­‐84  Fire-­‐Rated  SPF  CLASS  1  SPRAY  FOAM  SYSTEM  (Fast  Rise  Polyurethane  Foam)  
Applies  to  Product  ID#  TF600FR  and  TF200FR  Portable  Spray  Foam  Insulation  Systems  By    Commercial  Thermal  Solutions,  Inc.    
Approvals  and  Standards    
ASTM  E-­‐84  Class  1  Approval    
CCMC  #13484-­‐L  
ICC  Report  #ESR-­‐3183  
ODP  (Ozone-­‐Depletion  Potential):  Contains  non-­‐ozone-­‐depleting,  non-­‐flammable  HFC  Propellant.    
Tiger  Foam  conforms  to  international  guidelines  for  protection  of  the  ozone  layer  and  with  respect  to  the  Montreal  Protocol  of  
1987  and  other  environmental  guidelines.    
VOC  Content:  Contains  no  VOC's,  according  to  currently  accepted  definitions.    
Applications    
Spray  foam  onto  any  dry,  clean  surface  in  any  direction;  even  to  the  underside  of  a  floor  or  roof  deck.  This  product  will  adhere  
to  practically  any  substrate  except  Teflon®,  oily  surfaces,  greases,  polypropylene,  polyethylene,  silicone,  seals,  mold  release  
agents  &  similar  materials.  It  is  especially  critical  where  flame-­‐retardant  specifications  require  E-­‐84  Class  1  foam.  Protect  
surfaces  not  to  be  foamed.  Always  read  all  safety  data  sheets  and  operating  instructions  including  use  of  proper  personal  
protective  equipment  prior  to  use.  Based  on  the  manufacturer’s  Human  Health  Risk  Assessment,  we  recommend  a  minimum  of  
one  hour  for  safe  re-­‐occupancy  time  for  homeowner’s.  Please  consult  Commercial  Thermal  Solutions  Product  Management  
Department  for  details  (800-­‐664-­‐0063).  
Product  Description    
Tiger  Foam  E-­‐84  Class  1  Fire-­‐Rated  foam  insulation  is  a  multipurpose,  two-­‐part,  closed-­‐cell  polyurethane  formula  specifically  
manufactured  for  fire  retardancy.  The  packaging,  delivery  system,  and  components  were  designed  to  be  user-­‐  and  
environmentally  friendly.  These  systems  are  both  portable  and  disposable.  They  are  completely  self-­‐contained  to  provide  
flexibility  in  end  use  performance.  Tiger  Foam  E84  Fire-­‐Rated  SPF  Class  1  Spray  Foam  can  assist  in  attaining  LEED  and/  or  
ENERGY  STAR®  Certification.  Details  at  our  website:  www.tigerfoam.com  
Properties    
Two-­‐part  foam  systems  will  begin  to  expand  immediately  upon  chemical  reaction  of  the  "A"  component  (a  polymeric  
isocyanate)  and  "B"  component  (a  polyol  blended  with  proprietary  additive  ratios)  chemicals  to  a  volume  that  is  3-­‐5  times  the  
dispensed  volume,  depending  on  ambient  conditions.  The  foam  will  cure  to  semi-­‐rigid,  closed-­‐cell  foam.  Optimum  application  
temperature  of  the  chemicals  in  the  tanks  is  75°  F  (24°  C)  to  85°  F  (34°  C)  and  may  be  sprayed  onto  colder  or  warmer  substrates,  
with  slight  effects  on  the  foam's  characteristics.  Cured  foam  is  resistant  to  heat  and  cold  -­‐200°  F  to  +240°  F  (-­‐129°  C  to  +116°  C).  
It  is  also  resistant  to  negative  effects  of  aging.  It  is  not  resistant  to  UV  light  and  must  be  painted,  coated,  or  covered  if  exposed  
to  direct  sunlight  after  application.    
Cured  polyurethane  foam  is  chemically  inert  and  non-­‐reactive  in  approved  applications,  and  will  not  harm  electrical  wire  
insulations,  Romex®,  rubber,  PVC,  polyethylene  (i.e.,  PEX)  or  other  plastic.  It  is  approved  for  use  around  wires,  plumbing  
penetrations,  etc.,  and  contains  no  formaldehyde.  Tiger  Foam  creates  a  tight  seal  that  insulates  and  protects  against  dust,  air  
infiltration,  pests,  and  sound.    
Special  Features    
Cleanable  tips  (use  Acetone)    
Metered  spray  gun    
Tiger  Foam  systems  do  not  require  outside  electrical  or  mechanical  power  source.    
 
 
 
 
 
 
 
 
Technical  Data  (Metric  data  shown  in  parentheses)    
FIRE  RATING:  ASTM  E-­‐84  (Tested  according  to  ASTM  E-­‐84  at  a  maximum  thickness  of  2  inches  and  not  to  exceed  this  
thickness  as  recognized  by  ICC-­‐ES  Evaluation  Report  #ESR-­‐3183)  
Tested  @  2”       Flame  Spread  =  20  
Smoke  Developed  =  400  
 
FIRE  RATING  
CAN/ULC  S102       Flame  Spread  =  9  
Tested  at  2”  beads       Smoke  Developed  =  43  
Caulking  &  Sealant  
R-­‐Value  (Metric  RSI  in  parentheses):    Aged  -­‐  6  per  inch  (RSI=1.05/inch)  
Density:    
ASTM  D-­‐1622  (In  place  Density)   2.12  lb/ft³  (34  kg/m³)  
ASTM  D-­‐1622  (Free  Rise)     1.75  lbs/ft³  (28  kg/m³)    
K-­‐Factor  (per  inch):  ASTM  C-­‐518  -­‐  aged  90  days  @  140°  F    
0.166 BTU·inch / ft²·h·°F (0.023 W/m·K)

Air  Barrier  Properties:  ASTM  E-­‐283    


@  1.57  psf  (75  Pa)       <0.0025  cfm/ft²  (<0.0125  L/s/m²)  
@  6.24  psf  (300  Pa)        <0.01  cfm/  ft²  (<0.05  L/s/m²)    
Perm  Rating:  ASTM  E-­‐96  method  A    
@  1"  (2.54  cm)  =         1.67  (100  ng/(m²·∙Pa·∙s))    
@  2”  (5.04  cm)  =         1.44  (82  ng/(m²·∙Pa·∙s))  
@  3"  (7.62  cm)  =       1.00  (  57  ng/(m2·∙Pa·∙s))  
Fungi  Resistance:  ASTM  G21       No  Growth  
Tensile  Strength:  ASTM  D1623    
29  psi  (200  kPa)    
Compressive  Strength:  ASTMD-­‐1621    
Parallel  @  10%  -­‐           26 psi (179 kPa)
Perpendicular  @  10%  -­‐         16  psi  (110  kPa)    
Closed  Cell  Content  -­‐  ASTM  D-­‐2856       Greater  than  90%    
 
Tack  Free/Expansion  Time:  30-­‐60  seconds    
Cuttable:  2-­‐5  minutes    
Sandable:  1  hour    
Paintable:  5  minutes    
Fully  Cured:  1  hour    
Theoretical  Yield:    
TF600FR  =  600  board  feet  expanded  1"  =  50  cu.  ft.  (1.42  m³)    
TF200FR  =  200  board  feet  expanded  1"  =  16  cu.  ft.  (.45  m³)  
*Yields  are  based  on  theoretical  calculations,  for  comparative  purposes,  and  will  vary  depending  on  ambient  conditions  and  
particular  application.  For  calculating  actual  yield,  it  is  recommended  to  reduce  this  theoretical  yield  by  10-­‐12%  to  allow  for  
these  variations.  
Tank  Specifications:    
DOT—39  Approved  Cylinder    
TF600FR:  58  lbs  per  tank,  116  lbs  per  kit  
Box  Dimensions:  
H:  18"  (45.7  cm)    
W:  13"  (33  cm)    
L:  13”  (33  cm)  
TF200FR:  21  lbs  per  tank,  42  lbs  per  kit    
Box  Dimensions:  
H:  16”  (40.6  cm)    
W:  9”  (22.9  cm)    
L:  16”  (40.6  cm)  
*Filled  tank  weights  are  approximate  for  estimation  purposes  only.  Actual  gross  weight  is  formulation  specific  and  may  be  
slightly  higher  or  lower.    
Product  Storage:  Store  in  dry  area  below  120°  F  (49°).  Optimal  storage  temperature  is  60°  F  -­‐  80°  F  (15°  C  to  26°  C).  Do  not  
expose  to  open  flame  or  temperatures  above  120°  F  (49°  C).  Excessive  heat  or  cold  can  cause  premature  aging  of  components  
resulting  in  a  shorter  shelf  life.  Tiger  Foam  is  reusable  as  long  as  it  is  stored  in  a  warm  place,  nozzle  tip  is  changed,  and  product  
is  shaken  before  using.    
Cold  Weather:  For  best  results,  the  foam  chemical  temperature  must  be  between  75°F-­‐85°F  (24°-­‐29°C).  Warm  kits  for  a  
minimum  of  1  day  at  room  temperature.  In  extreme  cold  conditions  during  shipment  or  storage  are  encountered,  warm  tanks  
for  several  days  at  room  temperature  and  shake  well,  prior  to  warming  chemical  for  spray  application.  
 
Warning:  Use  only  in  well-­‐ventilated  area  with  certified  respiratory  protection.  Wear  gloves,  eye  protection,  and  protective  
clothing  during  application.  Read  all  instructions  and  safety  information  (MSDS)  prior  to  use.  The  product  contains  NO  
FORMALDEHYDE.  Cured  foam  is  non-­‐toxic.    
KEEP  OUT  OF  REACH  OF  CHILDREN    
Always  read  all  operating,  application,  and  safety  instructions  before  using  any  products  from  Tiger  Foam.  Use  in  conformance  
with  all  local,  state,  and  federal  regulations  and  safety  requirements.  Failure  to  strictly  adhere  to  any  recommended  procedures  
and  reasonable  safety  precautions  shall  release  Tiger  Foam  from  all  liability  with  respect  to  the  materials  or  use  thereof.    
Note:  Physical  properties  shown  are  typical  and  serve  only  as  a  guide  for  engineering  design.    
Results  are  obtained  from  specimens  under  ideal  laboratory  conditions  and  may  vary  upon  use,  temperature,  and  ambient  
conditions.  Right  to  change  physical  properties  as  a  result  of  technical  progress  is  reserved.  This  information  supersedes  all  
previously  published  data.  Yields  shown  are  based  on  theoretical  calculations  and  will  vary  depending  on  ambient  conditions  
and  particular  application.  Read  all  product  directions  and  safety  information  before  use.  Consult  local  building  codes  for  
specific  requirements  regarding  the  use  of  cellular  plastics  or  urethane  products  in  construction.    
Limited  Warranty:  The  Manufacturer  warrants  only  that  the  product  shall  meet  its  specifications:  this  warranty  is  in  lieu  of   all  
written  or  unwritten,  expressed,  or  implied  warranties  and  the  Manufacturer  expressly  disclaims  any  warranty  of  
merchantability,  or  fitness  for  a  particular  purpose.  The  buyer  assumes  all  risks  whatsoever  as  to  the  use  of  the  material.  
Buyer's  exclusive  remedy  as  to  any  breach  of  warranty,  negligence,  or  other  claim  shall  be  limited  to  the  replacement  of  the  
material.  Failure  to  strictly  adhere  to  any  recommended  procedures  shall  release  the  Manufacturer  from  all  liability  with  
respect  to  the  materials  or  use  thereof.  User  of  this  product  must  determine  suitability  for  any  particular  purpose,  including,  
but  not  limited  to,  structural  requirements,  performance  specifications,  and  application  requirements.  

You might also like