20) Chemistry-in-Power-Plant
20) Chemistry-in-Power-Plant
20) Chemistry-in-Power-Plant
PLANT
⚫ PRODUCTION OF : -
--- D.M. WATER FOR BOILER MAKE-UP.
--- FILTER WATER FOR SOFTENING PLANT, D.M.
PLANT, DRINKING WATER AND A.C. COOLING
SYSTEM.
⚫ MONITORING OF STEAM/ WATER PARAMETERS
⚫ H.P./L.P. DOSING.
⚫ TESTING OF COAL.
⚫ TESTING OF LUB OIL.
D.M. BOILER
U/G STORAGE PLANT MAKEUP
TANK
SOFTENING C.W.
PLANT MAKEUP
DRINKING COOLING
WATER WATER
WEAK STRONG
ACF ACID ACID
CATION CATION DEGASSER
⚫ pH - 7.0 ± 0.2
⚫ CONDUCTIVITY < 0.1 mho
⚫ TDS - NIL
⚫ SiO2 < 20 ppb
LP BFP
H.P. DOSING
HP BFP
8 December 15, 2021
WATER STEAM CYCLE
(THERMAL PROJECT)
HYDRAZINE AMMONIA
DOSING DOSING
CEP
PARAMETERS MONITORED
– pH
– Silica
– Conductivity
– After Cation Conductivity
– Dissolved Oxygen
– Sodium
– Copper
– Iron
⚫ FEED WATER
– ACC <0.2 uS/cm
– pH 8.8-9.2
– Total Iron+Copper <0.02 ppm
– Silica <0.02 ppm
– Dissolved Oxygen <7 ppb
⚫ CONDENSATE WATER
– ACC <0.2 uS/cm
– pH 8.8-9.2
⚫ BOILER WATER
– Conductivity <30 uS/cm
– pH 9.2-9.6
⚫ STEAM
– ACC <0.2 uS/cm
– pH 8.8-9.2
– Total Iron+Copper <0.02 ppm
– Silica <0.02 ppm
– Sodium <10 ppb
100
10-1
10-2
10-3
10-4
10-5
10-6
10-7
PRESSURE ( BAR)
16 December 15, 2021
SOURCES OF IMPURITIES IN STEAM
- Limits 2 to 5 PPM