0% found this document useful (0 votes)
95 views13 pages

Troubleshoot Acos

This document provides troubleshooting information for a Curtis Instruments controller, including: - A table summarizing the status LED display formats and what they indicate. - A chart listing controller fault codes, the associated fault name and effect, possible causes, and the conditions to set and clear each fault. - Descriptions of specific faults including the fault code, name, effect, possible causes, and set/clear conditions.

Uploaded by

Álvaro S.T
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views13 pages

Troubleshoot Acos

This document provides troubleshooting information for a Curtis Instruments controller, including: - A table summarizing the status LED display formats and what they indicate. - A chart listing controller fault codes, the associated fault name and effect, possible causes, and the conditions to set and clear each fault. - Descriptions of specific faults including the fault code, name, effect, possible causes, and set/clear conditions.

Uploaded by

Álvaro S.T
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

620 Magnolia Avenue

Suite B
Ontario, CA 91761
(909) 923-1973

CURTIS Instruments
Troubleshooting Codes

2/4/2014
Diagnostics
Diagnostics information can be obtained by observing the fault codes issued by
the Status LED’s or as displayed on the Spyglass. See Table below for a summary
of LED display formats.

The 1311 programmer will display all faults that are currently set as well as a
history of the faults that have been set since the history log was last cleared. The
1311 displays the faults by name.

Summary of LED display formats


The two LEDs have four different display modes, indicating the type of
information they are providing.

Display Status
Neither LED Illuminated Controller is not powered on; or
vehicle has dead battery; or severe
damage
Yellow LED flashing Controller is operating normally.
Yellow and red LEDs both on solid Controller is in Flash program mode

Red LED on solid Watchdog failure or no software


loaded. Cycle KSI to restart, and if
necessary load software.

Red LED and yellow LED flashing Controller has detected a fault. 2-digit
alternately code flashed by yellow LED identifies
the specific fault; one or two flashes
by red LED indicate whether first or
second code digit will follow.

The pair of LEDs built into the controller (one red, one yellow) produce flash
codes displaying all the currently set faults in a repeating cycle. Each code consists
of two digits. The red LED flashes once to indicate that the first digit of the code
will follow; the yellow LED then flashes the appropriate number of times for the
first digit. The red LED flashes twice to indicate that the second digit of the code
will follow; the yellow LED flashes the appropriate number of times for the second
digit.

Example: Battery Undervoltage (code 23).

In the Fault menu of the 1311 programmer, the words Undervoltage Cutback
will be displayed; the real-time battery voltage is displayed in the Monitor menu
(“Keyswitch Voltage”).The controller’s two LEDs will display this repeating
pattern:

RED YELLOW RED YELLOW


✱ ✲✲ ✱✱ ✲✲✲
(first digit) (2) (second digit) (3)

With this software package, not all of the codes below will be displayed on the
Spyglass or enGage VII. We have only utilized faults that are pertinent to our
software package.
Troubleshooting
The troubleshooting chart below provides the following information on all the
controller faults:

• fault code
• fault name as displayed on the programmer’s LCD
• the effect of the fault
• possible causes of the fault
• fault set conditions
• fault clear conditions

Whenever a fault is encountered and no wiring or vehicle fault can be found, shut
off KSI and turn it back on to see if the fault clears. If it does not, shut off KSI and
remove the 35-pin connector. Check the connector for corrosion or damage,
clean it if necessary, and re-insert it.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT

12 Controller Overcurrent 1. External short of phase U,V, or W Set: Phase current exceeded the current
ShutdownMotor; motor connections. measurement limit.
ShutdownMainContactor; 2. Motor parameters are mis-tuned. Clear: Cycle KSI.
ShutdownEMBrake; 3. Controller defective.
ShutdownThrottle; 4. Speed encoder noise problems.
FullBrake.
13 Current Sensor Fault 1. Leakage to vehicle frame from phase Set: Controller current sensors have
ShutdownMotor; U, V, or W (short in motor stator). invalid offset reading.
ShutdownMainContactor; 2. Controller defective. Clear: Cycle KSI.
ShutdownEMBrake;
ShutdownThrottle;
FullBrake.
14 Precharge Failed 1. See Monitor menu » Battery: Set: Precharge failed to charge the capacitor
ShutdownMotor; Capacitor Voltage. bank to the KSI voltage.
ShutdownMainContactor; 2. External load on capacitor bank (B+ Clear: Cycle Interlock input or use VCL
ShutdownEMBrake; connection terminal) that prevents function Enable_Precharge().
ShutdownThrottle; the capacitor bank from charging.
FullBrake.
15 Controller Severe Undertemp 1. See Monitor menu » Controller: Set: Heatsink temperature below -40°C.
ShutdownMotor; Temperature. Clear: Bring heatsink temperature
ShutdownMainContactor; 2. Controller is operating in an extreme above -40°C, and cycle interlock or KSI.
ShutdownEMBrake; environment.
ShutdownThrottle;
FullBrake.
16 Controller Severe Overtemp 1. See Monitor menu » Controller: Set: Heatsink temperature above +95°C.
ShutdownMotor; Temperature. Clear: Bring heatsink temperature
ShutdownMainContactor; 2. Controller is operating in an extreme below +95°C, and cycle interlock or KSI.
ShutdownEMBrake; environment.
ShutdownThrottle; 3. Excessive load on vehicle.
FullBrake.
17 Severe B+ Undervoltage 1.
1. See Monitor
Battery Menu menu » Battery:
parameters are Set:Capacitor
Set: When belowbankBrownout Voltage for
voltage dropped
Reduced drive torque. Keyswitch Voltage.
misadjusted. 2 seconds
below (see Table
the Severe D-1).
Undervoltage limit
2. Non-controller
2. Non-controller system
system drain
drainon
onbattery. (see page 58) with FET bridge
Clear: Bring KSI voltage above enabled.
3. battery/KSI
Battery resistance too high.
circuit wiring. Clear:
Brownout
BringVoltage.
capacitor voltage above
4. Battery disconnected while driving. Severe Undervoltage limit.
3.
5. KSISeedisconnected while driving.
Monitor menu » Battery:
Blown
4. Capacitor
KSI Voltage.
fuse.
6. Blown B+ fuse or main contactor
did not close.
17 Severe KSI Undervoltage 1.1. See
See Monitor
Monitor menu » Battery:
menu » Battery: Set:
Set:KSI voltage
When belowdropped
Brownout below 8.4 Vfor
Voltage
No Action. Keyswitch
Keyswitch Voltage.
Voltage. (Brownout occurs at 8.0 V.)
2 seconds (see Table D-1).
2. Non-controller system drain on Clear:
Clear:Bring
BringKSI
KSIvoltage
voltageabove
above8.4 V.
2. Non-controller system drain on
low power circuit
Brownout Voltage. voltage.
battery/KSI circuit wiring.
3. Resistance in low power circuit too high.
3.
4. Low KSI disconnected
power circuit while
powerdriving.
source
4. disconnected
Blown KSI fuse.
while driving.
5. Blown fuse.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT
18 Severe B+ Overvoltage 1. See Monitor menu » Battery: Set: Capacitor bank voltage exceeded
ShutdownMotor; Capacitor Voltage. the Severe Overvoltage limit (see page 58)
ShutdownMainContactor; 2. Battery menu parameters are with FET bridge enabled.
ShutdownEMBrake; misadjusted. Clear: Bring capacitor voltage below
ShutdownThrottle; 3. Battery resistance too high for given Severe Overvoltage limit, and then
FullBrake. regen current. cycle KSI.
4. Battery disconnected while regen
braking.
22 Controller Overtemp Cutback 1. See Monitor menu » Controller: Set: Heatsink temperature exceeded 85°C.
Reduced drive and brake Temperature. Clear: Bring heatsink temperature below
torque. 2. Controller is performance-limited 85°C.
at this temperature.
3. Controller is operating in an extreme
environment.
4. Excessive load on vehicle.
5. Improper mounting of controller.
23 B+ Undervoltage Cutback 1. Normal operation. Fault shows that Set: Capacitor bank voltage dropped below
Reduced drive torque. the batteries need recharging. the Undervoltage limit (see page 58) with
Controller is performance limited the FET bridge enabled.
at this voltage. Clear: Bring capacitor voltage above the
2. Battery parameters are misadjusted. Undervoltage limit.
3. Non-controller system drain on battery.
4. Battery resistance too high.
5. Battery disconnected while driving.
6. See Monitor menu » Battery:
Capacitor Voltage.
7. Blown B+ fuse or main contactor
did not close.
24 B+ Overvoltage Cutback 1. Normal operation. Fault shows that Set: Capacitor bank voltage exceeded the
Reduced brake torque. regen braking currents elevated the Overvoltage limit (see page 58) with the
Note: This fault is declared battery voltage during regen braking. FET bridge enabled.
only when the controller is Controller is performance limited Clear: Bring capacitor voltage below the
running in regen. at this voltage. Overvoltage limit.
2. Battery parameters are misadjusted.
3. Battery resistance too high for given
regen current.
4. Battery disconnected while regen braking.
5. See Monitor menu » Battery:
Capacitor Voltage.
25 +5V Supply Failure 1. External load impedance on the Set: +5V supply (pin 26) outside the
None, unless a fault action +5V supply (pin 26) is too low. +5V±10% range.
is programmed in VCL. 2. See Monitor menu » outputs: Clear: Bring voltage within range.
5 Volts and Ext Supply Current.
26 Digital Out 6 Open/Short 1. External load impedance on Digital Set: Digital Output 6 (pin 19) current
Digital Output 6 driver Output 6 driver (pin 19) is too low. exceeded 1 Amp.
will not turn on. Clear: Remedy the overcurrent cause
and use the VCL function Set_DigOut()
to turn the driver on again.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT
27 Digital Out 7 Open/Short 1. External load impedance on Digital Set: Digital Output 7 (pin 20) current
Digital Output 7 driver Output 7 driver (pin 20) is too low. exceeded 1 Amp.
will not turn on. Clear: Remedy the overcurrent cause
and use the VCL function Set_DigOut()
to turn the driver on again.
28 Motor Temp Hot Cutback 1. Motor temperature is at or above Set: Motor temperature is at or above the
Reduced drive torque. the programmed Temperature Hot Temperature Hot parameter setting.
setting, and the current is being Clear: Bring the motor temperature
cut back. within range.
2. Motor Temperature Control Menu
parameters are mis-tuned.
3. See Monitor menu » Motor:
Temperature and » Inputs: Analog2.
4. If the application doesn’t use a motor
thermistor, Temp Compensation
and Temp Cutback should be
programmed Off.
29 Motor Temp Sensor Fault 1. Motor thermistor is not connected Set: Motor thermistor input (pin 8) is at
MaxSpeed reduced (LOS, properly. the voltage rail (0 or 10V).
Limited Operating Strategy), 2. If the application doesn’t use a motor Clear: Bring the motor thermistor input
and motor temperature thermistor, Motor Temp Sensor voltage within range.
cutback disabled. Enable should be programmed Off.
3. See Monitor menu » Motor:
Temperature and » Inputs: Analog2.
31 Coil1 Driver Open/Short 1. Open or short on driver load. Set: Driver 1 (pin 6) is either open or
ShutdownDriver1. 2. Dirty connector pins. shorted. This fault can be set only when
3. Bad crimps or faulty wiring. Main Enable = Off.
Clear: Correct open or short, and cycle driver.
31 Main Open/Short 1. Open or short on driver load. Set: Main contactor driver (pin 6) is
ShutdownMotor; 2. Dirty connector pins. either open or shorted. This fault can be
ShutdownMainContactor; 3. Bad crimps or faulty wiring. set only when Main Enable = On.
ShutdownEMBrake; Clear: Correct open or short, and cycle driver
ShutdownThrottle;
FullBrake.
32 Coil2 Driver Open/Short 1. Open or short on driver load. Set: Driver 2 (pin 5) is either open or
ShutdownDriver2. 2. Dirty connector pins. shorted. This fault can be set only when
3. Bad crimps or faulty wiring. EM Brake Type = 0.
Clear: Correct open or short, and cycle driver.
32 EMBrake Open/Short 1. Open or short on driver load. Set: Electromagnetic brake driver (pin 5)
ShutdownEMBrake; 2. Dirty connector pins. is either open or shorted. This fault can
ShutdownThrottle; 3. Bad crimps or faulty wiring. be set only when EM Brake Type > 0.
FullBrake. Clear: Correct open or short, and cycle driver.
33 Coil3 Driver Open/Short 1. Open or short on driver load. Set: Driver 3 (pin 4) is either open or
ShutdownDriver3. 2. Dirty connector pins. shorted.
3. Bad crimps or faulty wiring. Clear: Correct open or short, and cycle driver.
34 Coil4 Driver Open/Short 1. Open or short on driver load. Set: Driver 4 (pin 3) is either open or
ShutdownDriver4. 2. Dirty connector pins. shorted.
3. Bad crimps or faulty wiring. Clear: Correct open or short, and cycle driver.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITION
EFFECT OF FAULT

35 PD Open/Short 1. Open or short on driver load. Set: Proportional driver (pin 2) is either
ShutdownPD. 2. Dirty connector pins. open or shorted.
3. Bad crimps or faulty wiring. Clear: Correct open or short, and cycle driver.
36 Encoder Fault 1. Motor encoder failure. Set: Motor encoder phase failure detected.
ShutdownEMBrake; 2. Bad crimps or faulty wiring. Clear: Cycle KSI.
Throttle_Command 3. See Monitor menu » Motor:
is not processed Motor RPM.
37 Motor Open 1. Motor phase is open. Set: Motor phase U, V, or W detected
ShutdownMotor; 2. Bad crimps or faulty wiring. open.
ShutdownMainContactor; Clear: Cycle KSI.
ShutdownEMBrake;
ShutdownThrottle;
FullBrake.
38 Main Contactor Welded 1. Main contactor tips are welded Set: Just prior to the main contactor
ShutdownMotor; closed. closing, the capacitor bank voltage (B+
ShutdownMainContactor; 2. Motor phase U or V is disconnected connection terminal) was loaded for a
ShutdownEMBrake; or open. short time and the voltage did not
ShutdownThrottle; 3. An alternate voltage path (such as an discharge.
FullBrake. external precharge resistor) is Clear: Cycle KSI
providing a current to the capacitor
bank (B+ connection terminal).
39 Main Contactor Did Not Close 1. Main contactor did not close. Set: With the main contactor commanded
ShutdownMotor; 2. Main contactor tips are oxidized, closed, the capacitor bank voltage (B+
ShutdownMainContactor; burned, or not making good contact. connection terminal) did not charge to B+.
ShutdownEMBrake; 3. External load on capacitor bank Clear: Cycle KSI.
ShutdownThrottle; (B+ connection terminal) that pre-
FullBrake. vents capacitor bank from charging.
4. Blown B+ fuse.
41 Throttle Wiper High 1. See Monitor menu » Inputs: Set: Throttle pot wiper (pin 16) voltage
ShutdownThrottle. Throttle Pot. is higher than the high fault threshold
2. Throttle pot wiper voltage too high. (can be changed with the VCL function
Setup_Pot_Faults()).
Clear: Bring throttle pot wiper voltage
below the fault threshold.
42 Throttle Wiper Low 1. See Monitor menu » Inputs: Set: Throttle pot wiper (pin 16) voltage
ShutdownThrottle. Throttle Pot. is lower than the low fault threshold
2. Throttle pot wiper voltage too low. (can be changed with the VCL function
Setup_Pot_Faults()).
Clear: Bring throttle pot wiper voltage
above the fault threshold.
43 Pot2 Wiper High 1. See Monitor menu » Inputs: Set: Pot2 wiper (pin 17) voltage
FullBrake. Pot2 Raw. is higher than the high fault threshold
2. Pot2 wiper voltage too high. (can be changed with the VCL function
Setup_Pot_Faults()).
Clear: Bring Pot2 wiper voltage below
the fault threshold.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT
44 Pot2 Wiper Low 1. See Monitor menu » Inputs: Set: Pot2 wiper (pin 17) voltage
FullBrake. Pot2 Raw. is lower than the low fault threshold
2. Pot2 wiper voltage too low. (can be changed with the VCL function
Setup_Pot_Faults()).
Clear: Bring Pot2 wiper voltage
above the fault threshold.
45 Pot Low OverCurrent 1. See Monitor menu » Outputs: Set: Pot low (pin 18) current exceeds 10mA.
ShutdownThrottle; Pot Low. Clear: Clear pot low overcurrent condition
FullBrake. 2. Combined pot resistance connected and cycle KSI.
to pot low is too low.
46 EEPROM Failure 1. Failure to write to EEPROM Set: Controller operating system tried to

ShutdownMotor; memory. This can be caused by write to EEPROM memory and failed.
ShutdownMainContactor;
EEPROM memory writes initiated Clear: Download the correct software (OS)
ShutdownEMBrake;
by VCL, by the CANbus, by and matching parameter default settings
ShutdownThrottle;
adjusting parameters with the into the controller and cycle KSI.
ShutdownInterlock;

ShutdownDriver1; programmer, or by loading new

ShutdownDriver2; software into the controller.
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake.
47 HPD/Sequencing Fault 1. KSI, interlock, direction, and throttle Set: HPD (High Pedal Disable) or
ShutdownThrottle. inputs applied in incorrect sequence. sequencing fault caused by incorrect
2. Faulty wiring, crimps, or switches at sequence of KSI, interlock, direction, and
KSI, interlock, direction, or throttle throttle inputs.
inputs. Clear: Reapply inputs in correct sequence.
3. See Monitor menu » Inputs.
 47 Emer Rev HPD 1. Emergency Reverse operation has Set: At the conclusion of Emergency
ShutdownThrottle; concluded, but the throttle, forward Reverse, the fault was set because various
ShutdownEMBrake. and reverse inputs, and interlock inputs were not returned to neutral.
have not been returned to neutral. Clear: If EMR_Interlock = On, clear the
interlock, throttle, and direction inputs.
  If EMR_Interlock = Off, clear the
throttle and direction inputs.
 49 Parameter Change Fault 1. This is a safety fault caused by a Set: Adjustment of a parameter setting
ShutdownMotor; change in certain parameter that requires cycling of KSI.
ShutdownMainContactor; settings so that the vehicle will not Clear: Cycle KSI.
ShutdownEMBrake; operate until KSI is cycled.
ShutdownThrottle; For example, if a user changes the
FullBrake. Throttle Type this fault will appear
and require cycling KSI before the
vehicle can operate.
  51–67 OEM Faults 1. These faults can be defined by the Set: See OEM documentation.
(See OEM documentation.) OEM and are implemented in the Clear: See OEM documentation.
application-specific VCL code. See
OEM documentation.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT

68 VCL Run Time Error 1. VCL code encountered a runtime Set: Runtime VCL code error condition.
ShutdownMotor; VCL error. Clear: Edit VCL application software to

ShutdownMainContactor; 2. See Monitor menu » Controller: fix this error condition; flash the new
ShutdownEMBrake;
VCL Error Module and VCL Error. compiled software and matching
ShutdownThrottle;
This error can then be compared to parameter defaults; cycle KSI.
ShutdownInterlock;
the runtime VCL module ID and
ShutdownDriver1;

ShutdownDriver2; error code definitions found in the

ShutdownDriver3; specific OS system information file.
ShutdownDriver4;
ShutdownPD;
FullBrake.

69 External Supply Out of Range 1. External load on the 5V and 12V Set: The external supply current (combined
None, unless a fault action supplies draws either too much or current used by the 5V supply [pin 26]
is programmed in VCL. too little current. and 12V supply [pin 25]) is either greater
2. Fault Checking Menu parameters than the upper current threshold or lower
Ext Supply Max and Ext Supply Min than the lower current threshold. The two
are mis-tuned. thresholds are defined by the External
3. See Monitor menu » Outputs: Supply Max and External Supply Min
Ext Supply Current. parameter settings (page 53).
Clear: Bring the external supply current
within range.
71 OS General 1. Internal controller fault. Set: Internal controller fault detected.

ShutdownMotor; Clear: Cycle KSI.
ShutdownMainContactor;

ShutdownEMBrake;

ShutdownThrottle;

ShutdownInterlock;

ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;

ShutdownDriver4;
ShutdownPD;
FullBrake.

72 PDO Timeout 1. Time between CAN PDO messages Set: Time between CAN PDO messages
ShutdownThrottle; received exceeded the PDO received exceeded the PDO Timeout
CAN NMT State set Timeout Period. Period.
to Pre-operational. Clear: Cycle KSI or receive CAN NMT
message.
73 Stall Detected 1. Stalled motor. Set: No motor encoder movement detected.
ShutdownEMBrake; 2. Motor encoder failure. Clear: Either cycle KSI, or
Throttle_Command 3. Bad crimps or faulty wiring. detect valid motor encoder signals while
is not processed; 4. Problems with power supply for operating in LOS mode and return
Control Mode changed to the motor encoder. Throttle Command = 0 and
LOS (Limited Operating 5. See Monitor menu » Motor: Motor RPM = 0.
Strategy). Motor RPM.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT
74 Fault On Other Traction Dual Drive fault: see Dual Drive manual.
Controller
75 Dual Severe Fault Dual Drive fault: see Dual Drive manual.
77 Supervisor Fault 1. The Supervisor has detected a Set: Mismatched redundant readings;

ShutdownMotor; mismatch in redundant readings. damaged Supervisor; illegal switch inputs.
ShutdownMainContactor;
2. Internal damage to Supervisor Clear: Check for noise or voltage drift in

ShutdownEMBrake; microprocessor. all switch inputs; check connections;
ShutdownThrottle;
3. Switch inputs allowed to be within cycle KSI.
ShutdownInterlock;
upper and lower thresholds for
ShutdownDriver1;

ShutdownDriver2; over 100 milliseconds.
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake.
78 Supervisor Incompatible 1. The main OS is not compatible Set: Incompatible software.
ShutdownMotor;
with the Supervisor OS. Clear: Load properly matched OS code
ShutdownMainContactor;
or update the Supervisor code; cycle KSI.
ShutdownEMBrake;

ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake.
82 Bad Calibrations 1. Internal controller fault. Set: Internal controller fault detection.
ShutdownMotor; Clear: Cycle KSI.
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake.
83 Driver Supply 1. Internal controller fault in the voltage Set: Internal controller fault detection.
ShutdownMotor; supply for the driver circuits. Clear: Cycle KSI.
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT

87 Motor Characterization Fault


1. Motor characterization failed during Set: Motor characterization failed during
ShutdownMotor;
characterization process. See Monitor the motor characterization process.
ShutdownMainContactor;
menu » Controller: Motor Clear: Correct fault; cycle KSI.
ShutdownEMBrake;
Characterization Error for cause:
ShutdownThrottle;
0=none
FullBrake.
1=encoder signal seen, but step size
not determined; set Encoder Step
Size manually
2=motor temp sensor fault
3=motor temp hot cutback fault
4= controller overtemp cutback fault
5=controller undertemp cutback fault
6=undervoltage cutback fault
7=severe overvoltage fault
8=encoder signal not seen, or one or
both channels missing
9=motor parameters out of character-
ization range.
88 Encoder Pulse Count Fault 1. Encoder Steps parameter does not Set: Motor lost IFO control and accelerated

ShutdownMotor; match the actual motor encoder. without throttle command.

ShutdownMainContactor; Clear: Ensure the Encoder Steps parameter
ShutdownEMBrake; matches the actual encoder; cycle KSI.
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake.
89 Motor Type Fault 1. The Motor_Type parameter value Set: Motor_Type parameter is set to an
ShutdownMotor; is out of range. illegal value.
ShutdownMainContactor; Clear: Set Motor_Type to correct value
ShutdownEMBrake; and cycle KSI.
ShutdownThrottle;
FullBrake.
91 VCL/OS Mismatch 1. The VCL software in the controller Set: VCL and OS software do not match;

ShutdownMotor; does not match the OS software in when KSI cycles, a check is made to verify
ShutdownMainContactor;
the controller. that they match and a fault is issued when
ShutdownEMBrake;
they do not.
ShutdownThrottle;
Clear: Download the correct VCL and OS
ShutdownInterlock;
software into the controller.
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake.
PROGRAMMER LCD DISPLAY
CODE POSSIBLE CAUSE SET/CLEAR CONDITIONS
EFFECT OF FAULT

92 EM Brake Failed to Set 1. Vehicle movement sensed after the Set: After the EM Brake was commanded
ShutdownEMBrake; EM Brake has been commanded to set and time has elapsed to allow the
ShutdownThrottle. to set. brake to fully engage, vehicle movement
Position Hold is engaged 2. EM Brake will not hold the motor has been sensed.
when Interlock=On. from rotating. Clear: Activate the throttle.
93 Encoder LOS (Limited 1. Limited Operating Strategy (LOS) Set: Encoder Fault (Code 36) or Stall
Operating Strategy) control mode has been activated, as Detect Fault (Code 73) was activated,
Enter LOS control mode. a result of either an Encoder Fault and Brake or Interlock has been applied
(Code 36) or a Stall Detect Fault to activate LOS control mode, allowing
(Code 73). limited motor control.
2. Motor encoder failure. Clear: Cycle KSI or, if LOS mode was acti-
3. Bad crimps or faulty wiring. vated by the Stall Fault, clear by ensuring
4. Vehicle is stalled. encoder senses proper operation, Motor
RPM = 0, and Throttle Command = 0.
94 EMR Rev Timeout 1. Emergency Reverse was activated Set: Emergency Reverse was activated and
ShutdownEMBrake; and concluded because the EMR ran until the EMR Timeout timer expired.
ShutdownThrottle. Timeout timer has expired. Clear: Turn the emergency reverse input
2. The emergency reverse input is Off.
stuck On.
98 Illegal Model Number 1. Model_Number variable contains Set: Illegal Model_Number variable; when
ShutdownMotor; illegal value. KSI cycles, a check is made to confirm
ShutdownMainContactor; 2. Software and hardware do not match. a legal Model_Number, and a fault is
ShutdownEMBrake; 3. Controller defective. issued if one is not found.
ShutdownThrottle; Clear: Download appropriate software
FullBrake; for your controller model.
99 Dualmotor Parameter Mismatch Dual Drive fault: see Dual Drive manual.