0% found this document useful (0 votes)
320 views1 page

Water Distribution Layout Sanitary Layout: Floor Drain Detail Detail of Water Meter

The document provides details on a plumbing system including various pipes, valves, and other components. It includes drawings showing the layout and connections between a water meter, gate valve, elbow, hose bibb, and drainage pipes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
320 views1 page

Water Distribution Layout Sanitary Layout: Floor Drain Detail Detail of Water Meter

The document provides details on a plumbing system including various pipes, valves, and other components. It includes drawings showing the layout and connections between a water meter, gate valve, elbow, hose bibb, and drainage pipes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A

ADJUSTABLE
STRAINER
UNION PATENTE 25Ø WATER METER
CAST IRON
F
25Ø GATE VALVE UNION PATENTE BODY DRAIN

D
90Ø ELBOW REDUCER BUSHING

15Ø HOSE BIBB


C
R.C. SLAB
CB

300
F/ S

508-101.6
ds
lav ds 25Ø CWL 25Ø CWL
KS WC CB
lav FD WRAPPED W/ BURLAP
KS WC & COATED W/ COALTAR P-TRAP WITH
IF BURRIED CLEAN-OUT PLUG
UNDERGROUND FOR
CORROSSION PROTECTION
A
vstr 25Ø CWL FROM 25Ø CWL FROM
MAIN WATER LINE MAIN WATER LINE
SECTION
ds
CB

DETAIL OF WATER METER FLOOR DRAIN DETAIL


N T S N T S

FLOOR DRAIN
"UNILEX" BRAND CLAMPING COLLAR WATER PROOFING
MODEL U 623 MEMBRANE SPLASH
FINISHED FLOOR INTO CLAMPING COLLAR
F ds ADJUSTABLE FLOOR SLAB
CB COUNTER SUNK HEAD
HEIGHT
WITH SCREW PLUG STRAINER
AND COVER EXPANSION
FLOOR SLAB SCREW THREAD SHIELD 50ØVENT
CLEAN OUT COVER
SEPTIC TANK MILD STEEL GRATING COVER SEALING
HANGER ROD
COMPOUND
L-25X25X6 FRAME
CIP P-TRAP
NOT LESS THAN
CLEAN OUT
CLAMP/PIPE
GV HANGER
2XDIA. OF PIPE
TAPPED TO MAIN NOTE:
M DRAINAGE LINE NO PIPE HANGER @. GROUND INSTALLATIONS.

CV
TAPPED TO MAIN
WATER LINE FLOOR CLEAN OUT DETAIL
N T S
10Ø HOR. & VERT. BARS @ 200MM. O.C.

WATER DISTRIBUTION LAYOUT SANITARY LAYOUT PVC DRAINING PIPE (VERIFY DIAMETER)

SCALE 1:100 MTS 4-10Ø BOTTOM BARS BW


SCALE 1:100 MTS
CATCH BASIN DETAILS
SCALE 1:100MTS

2.70

1.90 0.80
S
0.63 0.63 0.63 0.20 0.40 0.20 2.70
VARIES
F 1.90 0.80
WC C.O MANHOLE C.O MANHOLE
LAV
vs
tr 0.63 0.63 0.63 0.20 0.40 0.20

0.41 AIRGAP
10 mm Ø VERT. BARS

0.49 AIRGAP
F
CdB
s
INLET @ 0.60 M. O. C.
FD
lav WC

0.435
KS

MANHOLE MANHOLE
ds 10 mm Ø HOR. BARS @
CB

1.80
LEACHING EVERY 3 LAYER CHB
DIGESTIVE CHAMBER C.O

2.00
ds

CB CHAMBER 10 mm Ø CONTINOUS BARS &

0.63
1.50
F
TRANSVERESE BARS @ 0.30
NK
TA M.O.C

1.41
F ds P TIC
CB SE
5" THK CHB

GV

0.435
M C.O
CV TAPPED TO MAIN
TAPPED TO MAIN DRAINAGE LINE
WATER LINE
0.20

0.08
INLET PLAN

ISOMETRIC VIEW
ISOMETRIC VIEW
WATER DISTRIBUTION LAYOUT SANITARY LAYOUT SECTION
SCALE 1:100 MTS
SCALE 1:100 MTS

SEPTIC TANK DETAIL


SCALE NTS

PROJECT R.A. 545 ART. 2 SEC. 25 (4) SHEET CONTENTS MARK REVISIONS DATE SHEET NO.
ALL DESIGNS, DRAWINGS, SPECIFICATIONS AND COPIES THEREOF, PREPARED AND FURNISHED
BY THE ARCHITECT IN CONNECTION WITH THIS PROJECT, ARE INSTRUMENTS OF
PROFESSIONAL SERVICE. AS INSTRUMENTS OF PROFESSIONAL SERVICE THEY ARE THE WATER LINE LAYOUT
PROPOSED HIGH CEILING BUNGALOW PROPERTY OF THE ARCHITECT WHETHER THE WORK FOR WHICH THEY ARE MADE MAYBE
SANITARY LAYOUT
EXECUTED OR NOT, AND ARE NOT TO BE REPRODUCED OR USED ON OTHER WORK EXECPT

P-1
BY WRITTEN AGREEMENT WITH THE ARCHITECT WATER LINE ISOMETRIC LAYOUT
SANITARY ISOMETRIC LAYOUT
REG. NO. T.I.N. LOCATION DRAWN BY: CHECKED BY: SEPTIC TANK DETAIL
ENGR. ALLEN ROBERT WAGAN
Blk 19, Lot 17 EverGreen County Brgy Mamplasan, Binan Laguna DETAIL OF WATER METER
CATCH BASIN DETAILS
P.T.R. DATE: PLACE: OWNER DESIGNED BY: DATE: FLOOR DRAIN DETAIL
MR. MARLON DEQUITO FLOOR CLEAN OUT DETAIL