MPC Cable Specification - EE-999999-0011

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Specification: MOLD POWER CABLES, 14 AWG, 11/17/25 CONDUCTOR Page 1 of 4

EE-999999-0011 REV: C 07/08/13

D-M-E Company
29111 Stephenson Highway
Madison Heights, MI 48071

Description:
Mold Power Cables, Using 14 AWG Conductors (3 Cables):

-11 Conductors (Cable #1)


-17 Conductors (Cable #2)
-25 Conductors (Cable #3)

Each Power Cable Consists Of The Following:

-14 AWG PVC Insulated Conductors (11, 17, or 25 as required), Assembled With An
Overall Polyester Wrap

-Overall Flame Retardant & Oil Resistant Grey PVC Jacket.

-All Materials Are To Be Compliant To The E.U. “Restriction Of Hazardous Substances”


Directive. (ROHS)

Specification Details:
Cable #1 Cable #2 Cable #3
Number of 11 Conductors 17 Conductors 25 Conductors
Conductors and Size #14 AWG #14 AWG #14 AWG
(AWG)
Certification: CSA C22.2 NO. 210.2-M90 (AWM)
UL Subject #758, Style #2587

Electrical
Characteristics
Voltage Class (Volts) 600
Nominal Resistance 2.75
@ 25C (ohms/M ft)

Construction
Specifications
Type of Conductor 19 x 0.0147 dia.
Stranding (in) Concentric Bare Copper
Diameter of 0.074
Conductor (in) Concentric Bare Copper
Conductor Insulation Flame Retardant PVC 105C wet / 75C dry
Type
Specification: MOLD POWER CABLES, 14 AWG, 11/17/25 CONDUCTOR Page 2 of 4
EE-999999-0011 REV: C 07/08/13

Average Insulation 0.020


Thickness (in)
Diameter of Insulated 0.114
Conductor (in)
Overall Separator (in) Clear Mylar Tape
Thickness of Overall 0.001
Separator (in)
Outer Jacket Material 90-40C Oil Resistant Flame Retardant PVC, Grey with ripcord
Type
Average Jacket 0.045 0.050 0.060
Thickness (in)
Outer Diameter (OD) 0.377 0.674 0.808
over Outer Jacket (in)
MAXIMUM Outer 0.593 0.726 0.870
Diameter (OD) of
Cable (in)
Conductor 14 AWG/11C, 600V, 14 AWG/17C, 600V, 14 AWG/25C, 600V,
Identification 90C, FT4/IEEE 1202, 90C, FT4/IEEE 1202, 90C, FT4/IEEE 1202,
, , ,

Physical
Characteristics
Min. Bend Radius: 2.3 4.0 4.8
Permanent (in)
Min. Bend Radius: 3.4 6.1 7.3
Pull (in)
Net Cable Mass 229 347 507
(lbs/M ft)
Maximum Conductor 90
Temperature (C)
Recommended Min. -10
Installation Temp (C)
Vertical Tray Flame Passes Flame Test 4 (FT4)
Test: IEEE 1202

Wire Identification / Marking Options


1. Colored Wire Insulation
Wire Color Definitions: (Main Color / Major Stripe / Minor Stripe)
Conductor Cable #1 Wire Colors Cable #2 Wire Colors Cable #3 Wire Colors
Number (11 Conductor) (17 Conductor) (25 Conductor)
1 Green / Black Green / Black Blue / Black
2 Orange / Black Orange / Black Black / White
3 Black Blue / Black Red / White
4 White Black / White Orange / Black
5 Red Red / White Blue / Red
6 Green Green / White Orange / Red
7 Orange Black Green
8 Blue White Orange
9 White / Black Red Green / Black
10 Red / Black Green Green / White
Specification: MOLD POWER CABLES, 14 AWG, 11/17/25 CONDUCTOR Page 3 of 4
EE-999999-0011 REV: C 07/08/13

11 Blue / Black Orange Green / Black / White


12 Blue Red / Black / White
13 White / Black Black / White / Red
14 Red / Black Orange / Green
15 White / Red Red / Green
16 Black / Red White / Red
17 Blue / White Black / Red
18 Blue / White
19 Black
20 White
21 Red
22 Blue
23 White / Black
24 Red / Black
25 White / Black / Red
2. Printed Text On Wire Insulation
Printed Black Wires, Plus 1 Unprinted Green Wire
Conductor Cable #1 Wire Printing Cable #2 Wire Printing Cable #3 Wire Printing
Number (11 Conductor) (17 Conductor) (25 Conductor)
1 #1 #1 #1
2 #2 #2 #2
3 #3 #3 #3
4 #4 #4 #4
5 #5 #5 #5
6 #6 #6 #6
7 #7 #7 #7
8 #8 #8 #8
9 #9 #9 #9
10 #10 #10 #10
11 Unprinted: #11 #11
*Green / Yellow*
12 #12 #12
13 #13 #13
14 #14 #14
15 #15 #15
16 #16 #16
17 Unprinted: #17
*Green / Yellow*
18 #18
19 #19
20 #20
21 #21
22 #22
23 #23
24 #24
25 Unprinted:
*Green / Yellow*
Specification: MOLD POWER CABLES, 14 AWG, 11/17/25 CONDUCTOR Page 4 of 4
EE-999999-0011 REV: C 07/08/13

Conductor Positions:

11 Conductor 17 Conductor 25 Conductor

ECN’S:
ECN-0670 01/07/07 E.U. Restriction Of Hazardous Materials (ROHS) note added.
ECN-E0697 07/08/13 Added alternate optional wire marking scheme.
Document number was SP-0031-M-016.

APPROVAL:

CHECKED BY: _____T. JOHNSTON________________ DATE ____07/08/13_______

APPROVED BY: _____C. KOVACIC________________ DATE _____07/08/13_______