MPC Cable Specification - EE-999999-0011
MPC Cable Specification - EE-999999-0011
MPC Cable Specification - EE-999999-0011
D-M-E Company
29111 Stephenson Highway
Madison Heights, MI 48071
Description:
Mold Power Cables, Using 14 AWG Conductors (3 Cables):
-14 AWG PVC Insulated Conductors (11, 17, or 25 as required), Assembled With An
Overall Polyester Wrap
Specification Details:
Cable #1 Cable #2 Cable #3
Number of 11 Conductors 17 Conductors 25 Conductors
Conductors and Size #14 AWG #14 AWG #14 AWG
(AWG)
Certification: CSA C22.2 NO. 210.2-M90 (AWM)
UL Subject #758, Style #2587
Electrical
Characteristics
Voltage Class (Volts) 600
Nominal Resistance 2.75
@ 25C (ohms/M ft)
Construction
Specifications
Type of Conductor 19 x 0.0147 dia.
Stranding (in) Concentric Bare Copper
Diameter of 0.074
Conductor (in) Concentric Bare Copper
Conductor Insulation Flame Retardant PVC 105C wet / 75C dry
Type
Specification: MOLD POWER CABLES, 14 AWG, 11/17/25 CONDUCTOR Page 2 of 4
EE-999999-0011 REV: C 07/08/13
Physical
Characteristics
Min. Bend Radius: 2.3 4.0 4.8
Permanent (in)
Min. Bend Radius: 3.4 6.1 7.3
Pull (in)
Net Cable Mass 229 347 507
(lbs/M ft)
Maximum Conductor 90
Temperature (C)
Recommended Min. -10
Installation Temp (C)
Vertical Tray Flame Passes Flame Test 4 (FT4)
Test: IEEE 1202
Conductor Positions:
ECN’S:
ECN-0670 01/07/07 E.U. Restriction Of Hazardous Materials (ROHS) note added.
ECN-E0697 07/08/13 Added alternate optional wire marking scheme.
Document number was SP-0031-M-016.
APPROVAL: