Factsheet TA B TECO

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Cast Resin

Busbar Trunking System


Al: 400A to 6569A
Cu: 400A to 6569A

IP68

The First & Only Busbar Trunking


KEMA
System Test & Assembly Line In Singapore BS 6387
IEC 60331-21
IEC 60068 / IEC 60529

SYSTEM OVERVIEW
1
11
2
4 3
1. Flangle End
2. Flexible Link or
at
n er
3. Edgewise Elbow Ge
4. Straight Length
5. Main Switchboard
6. Joint 5

10 7

9
7. Switchboard/Distribution Board
8. Horizontal Elbow
8 9. Tap-Off Unit (Plug-in Unit)
10. Spring Hanger
11. End Cap

PRODUCT FEATURES

Waterproof The water proof test of Busbar Fireproof The fire proof test of Busbar meets the
(with junction) meets the standard standard of BS 6387 950℃ for 3 hours
of IEC 60529 reaching IP68. IEC 60331-21 950℃ for 3 hours
CNS 14286 840℃ for 30 minutes.

CERTIFICATIONS
Product quality and capability have been assured and certified by international

renowned testing authorities including Dekra, KEMA, and has been approved to

be environmental friendly.

Tai Sin Power Distribution Pte Ltd www.taisin.com.sg [email protected] (+65) 6672 9292
Busbar Trunking System
The First & Only Busbar Trunking
System Test & Assembly Line In Singapore

PRODUCT SPECIFICATIONS

LA 72mm 88mm
N E N E N E

Total Total
ln(A) ln(A) ln(A) ln(A)
TYPE B x H mm Weight TYPE B x H mm Weight
norm 35/40°C norm 35/40°C
kg/m kg/m

H
H

H
COPPER ALUMINIUM
$1% ĭ: $1%* ĭ:( RST RST RST
567 ĭ: 1567 ĭ:
567* ĭ:( B B
Single Lines Single Lines
Single Lines Double Lines
LA02EC 104 x 60 400 400 13.8 104 x 80 400 500 15.3
LA04EC 104 x 80 630 630 20.3 630 630 15.8
• Conductor:
800 800 23.3 LA08EA 104 x 120 800 810 23.3
LA08EC 104 x 120 1000 1000 33.5 1000 1000 24.4
1P3W represents single phase, three wires
1250 1250 35.7 LA12EA 104 x 160 1250 1375 31.1
3P3W represents three phases, three wires

LA12EC 104 x 160 1600 1600 50.2 LA16EA 104 x 200 1600 1700 41.3
3P4W represents three phases, four wires.

LA16EC 104 x 200 2000 2000 64.4 E represents grounding phase 100% of rated current.
Double Lines 200% N and aluminum grounding conductor optional
2221 71.5
LA20EC 104 x 240 2500 2500 79.0 LA12DA 404 X 160 2000 2380 48.8 • Distance between the two elements among double lines
2500 2660 65.4 remains 300mm center to center.
Double Lines
LA16DA 404 x 200 3150 3250 82.6 • Applicable to DC requirement.
LA08DC 404 x 120 2500 2500 78.6
LA12DC 404 x 160 3150 3200 111.0
LA16DC 404 x 200 4000 4000 128.8
4202 143.0

LB 120mm PP
N E N N E N N E N

Total Total
ln(A) ln(A) ln(A) ln(A)
TYPE B x H mm Weight TYPE B x H mm Weight
norm 35/40°C norm 35/40°C
H

H
kg/m kg/m

COPPER ALUMINIUM ANBBNA


ĭ:
ANBG
ĭ:(
RST TSR RST TSR RST TSR
B B
ĭ: RSTGTSR
ĭ:(
Single Lines Single Lines
Single Lines Double Lines
LB08EC 168 X 120 2000 2000 55.1 LB12EA 168 x 160 2000 2100 53.5
LB12EC 168 X 160 2500 2500 86.5 LB16EA 168 x 200 2500 2540 63.6
• Conductor:
LB16EC 168 x 200 3150 3200 111.5
Double Lines 1P3W represents single phase, three wires
3443 122.0
3P3W represents three phases, three wires
LB08DA 468 x 120 3150 3200 79.0
Double Lines 3P4W represents three phases, four wires.
LB12DA 468 x 160 4000 4250 101.1
50%E represents grounding phase 50% of rated current.
LB08DC 468 x 120 4000 4000 110.2 LB16DA 468 x 200 5000 5400 135.0
200% N and aluminum grounding conductor optional
LB12DC 468 x 160 5000 5000 173.0
LB16DC 468 x 200 6300 6300 223.0 • Distance between the two elements among double lines
6569 244.0 remains 300mm center to center.
• Applicable to DC requirement.

ABOUT US

Tai Sin was incorporated in 1980, we specialise in power distribution products and solutions. Our business has
expanded to busbar trunking system and branch cable systems for use in areas of power distribution network for
commercial, residential, industrial and infrastructure projects.

CABLES & WIRES BUSBAR TRUNKING SYSTEMS BRANCH CABLE SYSTEMS

Tai Sin Power Distribution Pte Ltd www.taisin.com.sg [email protected] (+65) 6672 9292

You might also like