Column & Footing
Column & Footing
1 Column Mark C6
staad output
Beam no. 3070, 2453, 2909, 2742, 986, 160
Node no. 6
2 Design Load
critical load combination 6
Vertical 1179.66 KN
Mz 34.81 KN
Mx 0 KNm
6 Analysis
length of column 2 m
7 Design
d'/D 0.08
Pu/fckbD 0.3276833333
Mu/fck b D2 0.0161157407
8 as per SP 16 , chart 46
P/fck 0.02
Lateral Ties
Diameter (1/4 th of largest dia. Of bar & < 6mm) 5 mm
say 8 mm
pitch
7 Lenth of footing Lf
Lf
(D-b)/2+((D-b)^2/4+Af)1/2=(Af)1/2 since b=D
Lf = 0.842785 m
= 842.7845 mm
Width of footingBf=Af/Lf 0.8427845 m
= 842.7845 mm
Size of footing
L 867.7845005 2000 mm 2.00 m
B 867.7845005 1600 mm 1.60 m
Area of footing 3200000 3.2000 m2
sectional modulus Zx = 1.0667 m3
Zy= 0.8533333 m3
8 Upward reaction w = P/Af
= 248.31 KN/m2
= -92.9375 KN/m2
9 Projection of footing for bending at X Perpen To Lf
Cx= (Lf-D)/2= 650 mm
= 0.7 m
10 Projection of footing for bendingatY parll To Lf
Cy= (Bf-b)/2= 650 = 0.65 m
11 a)B.M. at column face llar to X-axis,
Mux=wu B X1^2/2= 52.45601563 KN.m /m
Ay1=Lxdymin+(dy1-dymin)(Lf+Ly1)/2
= 1088025
Pty=100Asty/(Lxd)= 0.13242376
Ax1=B x dxmin+(dx1-dxmin)(B+Lx1)/2
= 910025
Pty=100Asty/(Lxd)= 0.105939
Shear strenth of concrete
Tuc=(0.85(√0.8Fck)(√(1+5β)-1)/(6β)
β=0.8Fck/(6.89pt) = 21.9202
1
Tuc = 0.246019 N/mm2
Vuc=Tuc*Ay1 = 223.8838362 KN
Vu=Wu x L(cy - dy)
= 122.1698 KN
safe
safe
16 Required Ast
soil ht.
mm
mm
mm
mm
mm
mm
mm
Design
L
of Reinforced Concrete Isolated pad foundation
Footing Pressure,
Pmax = P/A + My/Zy + Mz/Zz
Pmax 248.31 kN/m2
Pmin = P/A - My/Zy - Mz/Zz
Pmin -92.9375 kN/m2
Eccentricity:
Y 1.455311 mt
X 0.54 mt
L 2.00 mt
L
2/3 L 1.333333 mt
Y
Flexure design: X
Shear Chk.
One way Shear : At distance d from face of column.
h d c
Vu 152.7122 kN
Vuc 295.9318 kN Safe
Y
a
c
g
b