DS VSU12 4 5 en
DS VSU12 4 5 en
DS VSU12 4 5 en
Dimensioned drawing
Part No. 501 11731
20 … 40mm
10 - 30 V
DC
Electrical connection
We reserve the right to make changes • VSU_12_gb.fm
IP 65
Accessories:
(available separately)
z M12 connectors (KD …)
z Ready-made cables (KB …)
5-pin: KB-095-5000-5A
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 VSU 12/4.4(.5) - 03
[email protected] • www.leuze.com DB 18 UP.1 - 03
VSU 12
Specifications Tables
Sensor data DB 18 UP VSU 12/4.4.../4.5
Operating range (recommended) 25mm
Operating range limit 20 … 40mm
Converter frequency 200kHz ± 2%
Sound cone approx. 12°
Timing
Web speed max. 1000m/min
min.≥ 6mm/s
(with 30mm splice width)
Recovery-time constant (LED A flashes path clear/
briefly) inserted medium < 5s
Delay before start-up ≤ 100ms
Pulse stretching 0 … 200ms, adjustable
Electrical data
Operating voltage UB 10 … 30VDC
(incl. residual ripple)
Residual ripple ≤ 15% of UB
Bias current ≤ 75mA
Outputs
Tape PNP transistor output
Function forced tripping of transistor
when splice detected
Level under limit PNP transistor output
Function forced tripping of transistor
when material not detectable
VSU 12/4.5
Web material (paper tear) PNP transistor output Diagrams
Function forced tripping of transistor
Splice width in dependence of web speed
when material present between
the sensors 70
Signal voltage high/low ≥ (UB -2V)/≤ 2V
60
Output current max. 200mA per output
Order guide
Designation Part No.
Sensor pair DB 18 UP.1-25, 2500 501 08998
Technical description
General
The ultrasonic system for splice detection consists of a VSU 12/4… evaluation amplifier and a DB 18 UP ultrasonic sensor pair.
It mainly detects splices on paper, plastic or metal web used on roll machines.
Mounting
Transmitter and receiver (DB 18 UP) have the same construction and are to be mounted at an angle of 65° (± 2°) relative to the
sheet.
The distance between transmitter and receiver should be 25mm (± 5mm).
Exact alignment (± 1°) must be ensured. Alignment which is not in line with the axis results in a reduction of the working range.
The material to be scanned must be located approx. 8 … 10mm above the transmitter.
The pitch of the sensors should be parallel to the tape or, as the case may be, splices.
Function
The evaluation unit can be operated in two different modes.
The changeover from "paper" to "foil" can also be performed via PIN 5 "Paper/Foil". Low-level on connection 5 means "paper",
high-level (≥ 8V) on connection 5 means "foil". The parameter switch S1 must be in position 0 "paper" in order to use this feature
(state on delivery).
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 VSU 12/4.4(.5) - 03
[email protected] • www.leuze.com DB 18 UP.1 - 03
VSU 12
Display
(see Specifications)
A Red LED
Adjustment
B Green LED
(see Specifications)
C Yellow LED
D Green LED
P1 Potentiometer
0 … 200ms pulse stretching
P2 Potentiometer
sensitivity adjustment
S1 Foil/Paper switch
0 = paper
1 = foil
A Receiver
B Holder
C Transmitter
D Paper or foil web
E Direction of travel
F Splice